Loading...
HomeMy WebLinkAboutEngineer PlanPermit valid for REPAIR OF SEPTIC SYSTEM ONLY, due to State and Local septic variances. Board of Health review and approval is required for any future additionslrenovations!alterations to sewage facilities and/w structures/dwelling. Yarmouth Health Department APPROVED - P N STC Dab CBDH 7.03-- r r % X r r r r r 7.06 r/ ! i CL/Z!-6.03 x/ /X4.60 4.66 o TP-1�-211 � 4.86 EXISTING CESSPOOL'�__ X, TO BE REMOVED `c n n Jn CBDH 6.13 5.06 5,61 X LOT AREA 5,827tS.F. 43.33' N 89'27'2 •-"i 4.91 eo9e of EXIS77NG DRIVEWAY 4.99 P TO REMAIN IN SAME LOCATION WITH GRADE CHANGES VINEYARD ZONING DESIGNATION R-25 FRONT YARD SETBACK = 30' SIDE YARD SETBACK = 15' REAR YARD SETBACK = 20' FEMA FLOOD DESIGNATION MAP NUMBER: 25001CO589J EFFECTIVE DATE: JULY 16, 2014 AE (EL11) DRIVEWAY PK SET 5.23 EXISTING SHED TO BE REMOVED _rF- - fenc \ \ e �e 4.74ic q 88. LAB, 4.61 x d LEGEND --7 -- EXISTING CONTOUR x 5.12 EXISTING SPOT GRADE - O.H.W- OVERHEAD WIRES -W- EXISTING WATER SERVICE -G- EXISTING GAS SERVICE 0 TEST PIT B BENCHMARK EXISTING HOUSE TO BE RAISED ABOVE BASE .� FLOOD ELEVATION EXISTING GAS & ELECTRIC CONTRACTOR SHALL CONSULT x 4. WITH U77LITY COMPANY FOR NEW CONNECTIONS x 5.27 x 5.46 1 48.68, �C 75.31W7* W_e� 5.76 5.5 516 5.38 Q ^ 5.47 ^O �+ v fy QO A 5.58 �7 ` BENCHMARK STREET E� =.5 z31 SET CFCJCKO� T. EXISTING CONDITIONS STEPHEN W. CARTWRIGHT No. 37041 ?Or/z3 '7I E� OWNER OF RECORD FARRELL, MICHAEL F & DEBORAH R 87 BROWNS BEACH ROAD BRISTOL, NH 33222 LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: -310 CMR 15.405(1)(h): LOCAL UPGRADE APPROVAL 1) A 1' reduction to the 5' separation between bottom of S.A.S. to estimated maximum seasonal high groundwater, for 4' of separation. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON NAVD88. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 1.0. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. 14. THE CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT PRIOR FOR ALL ELECTRICAL RELATED WORK. MAP ID: 25-167 PROPOSED SEPTIC SYSTEM SITE PLAN 175 PINE GROVE ROAD, SOUTH YARMOUTH, MA Prepared for: Michael Farrell, 175 Pine Grove Rd, South Yarmouth, MA 02664 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. R.A.S. associates 1 "=20' P.T.M. 253-22 12 West Crossfield Road 30 Carolyn Drive DATE CHECKED SHEET N0. Forestdole, MA 02644 Plymouth, MA 02360 (508) 477-5313 (508) 224-9035 1/3/23 P.T.M. 1 of 5 40 MIL POLY LINER TOP OF LINER EL.=6.8 BOTTOM OF LINER, EL.=4.3 m AIR RELEASE VALVES PROPOSED PUMP CH) PROPOSED SEPTIC T HYDRAULIC UNIT 4.91 x CBDH 7.0: Ury y�� ti� �W i 7.06 � X\ O PROPOSED 43.33' F./ N 89'27'25" W DRIVEWAY 5.31 of 4.99 Poverrrent PK SET 5,23 VINEYARD STREET FEMA FLOOD DESIGNATION MAP NUMBER: 25001CO589J EFFECTIVE DATE: JULY 16, 2014 AE (EL11) PROPOSED S.A.S. PERC—RITE DRIP DISPERSAL SYSTEM 17' x 27' EFFECTIVE AREA 16 LINES, 27' LONG PROPOSED RET. WALL TOP OF WALL, EL.=6.0 BOTT. OF WALL, EL.=5.0f PROPOSED RAISED HOUSE PROPOSED HOUSE T.O.F.=12.0 CRAWL FL=7.5 F US F 4 �1 48.68' '7'43' 5.76 5.16 BENCHMARK MAG. NAIL SET EL.=5.23 LEGEND --7 -- EXISTING CONTOUR x 5.12 EXISTING SPOT GRADE v PROPOSED CONTOUR PROPOSED SPOT GRADE —O-H.W.- OVERHEAD WIRES —W— EXISTING WATER SERVICE EXISTING GAS SERVICE TEST PIT BENCHMARK LOT` AREA ; 5.27 �5,822�tS.F. PROPOSED ROOF DRAIN V ONE HI CAP INFILTRATOR 1 SURROUNDED W/2' STONE —A ON EACH SIDE OF HOUSE SET BOTTOM EL.=3.5 5.38 STEPHEN ^O\Y�� 5.47 '�[w Y W. CARTWRIGHT Svc 37041 All, A.No. AaAuaslg'v �f/p W D� 0� Q .4 3 aQ 5.58 Y s t S or u �se�.iivumuu�l e,_ s' a E LOCUS MAP �P\\\ OF 414jo. s2 PETER T. yG� o MCENTEE v CIVIL No. 35109 ISTE� I '7 ZONING DESIGNATION R-25 FRONT YARD SETBACK = 30' SIDE YARD SETBACK = 15' REAR YARD SETBACK = 20' NOTE: A SPECIAL PERMIT HAS BEEN OBTAINED FROM THE ZONING BOARD OF APPEALS TO RAISE THE EXISTING BUILDING ABOVE THE BASE FLOOD ELEVATION TO COMPLY WITH BUILDING CODE. MAP ID: 25-200 PROPOSED SEPTIC SYSTEM SITE PLAN 175 PINE GROVE ROAD, SOUTH YARMOUTH, MA >repared for: Michael Farrell, 175 Pine Grove Rd, South Yarmouth, MA 02664 OWNER OF RECORD Engineers: Surveyors: SCALE DRAWN JOB. NO. FARRELL, MICHAEL F & DEBORAH R Engineering Works, Inc. R.A.S. associates 1 "=20' P.T.M. 253-22 87 BROWNS BEACH ROAD 12 West Crosstield Road Forestdole, MA 02644 30 Carolyn Drive Plymouth, MA 02360 DATE CHECKED SHEET NO. BRISTOL, NH 33222 (508) 477-5313 (508) 224-9035 1/3/23 P.T.M. 2 of 5 PROPOSED SEPTIC TANK INLET MANHOLE: RISER/COVER TO 6" OF GRADE TOP OF FOUNDATION OUTLET MANHOLE: RISER, FRAME/COVER SET AT GRADE ELP OF � SECURE COVER TO PREVENT UNAUTHORIZED ACCESS F.G. EL=7.Of /-F.G.=6.8t PROVIDE W1LETl �( L m 1 Al OR ABOVE Ia s=1z INV=5.50 4"SCH40 TOP EL.=5.65 48" UOL LEVEL HU L-8' 0 S=17„ (MIN.) 4"SCH40 PVC MODIFY INTERIOR INV.=4.251 -tm ' PLUMBING IF REQ'D INV.=4.00 .... . . . .. .. CONTRACTOR SHALL V-1,11 ALL EXISTING PIPE INVERTS 11112dMBOTT. EL.=-0.29 1500 GALLON SEPTIC MONOLITHIC TANK PRIOR TO CONSTRUCTION. WIGGIN PRECAST CORP MODEL#TM1500H PROPOSED PUMP CHAMBER PROVIDE RISERS WITH FRAMES & COVERS OVER EACH ACCESS MANHOLE AND SET TO FINISH GRADE. MANHOLES BROUGHT TO GRADE SHALL BE SECURED TO PREVENT UNAUTHORIZED ACCESS. /-F.G. EL=7.0t ALARM, EL =2.8 PEAK ENABLE, EL=1.9 DRIP ENABLE, EL.=1.1 PUMP OFF, EL=0.1 1000 GALLON MONOLITHIC PUMP CHAMBER WIGGIN PRECAST CORP MODEL#PC1000MONOH F.G. EL.=7.1± HYDRAULIC UNIT (SEE SHEET 4) AIR RELEASE VALVES AND INSTALLED BY SARGENT ST., GLOUCESTER, MA NOTES: 1) ALL TANKS, COVERS AND PIPING SHALL BE WATERTIGHT. 2) DRIPLINES SHALL BE INSTALLED OVER PREPARED SAND BASE. STRIPOUT 3) SAS MUST NOT BE DRIVEN OVER AND NO HEAVY EQUIPMENT SHALL REMOVE "A" HORIZON TO SUITABLE BE USED OVER THE SAS DURING INSTALLATION. SOILS WITHIN THE S.A.S. FOOTPRINT. FILL WITH TITLE 5 SAND TO DRIPLINE 4) THE FUNCTIONING AND OPERATION OF THIS SEPTIC SYSTEM OR ITS COMPONENTS EL.=6.7 (SEE ALSO, NOTE 11). IS NOT GUARANTEED DURING, OR FOLLOWING, EXTREME WEATHER CONDITIONS INCLUDING, BUT NOT LIMITED TO, FLOODING OR WAVE ACTION. REPAIR OR REPLACEMENT OF THE SEPTIC SYSTEM OR ITS COMPONENTS MAY BE REQUIRED AFTER SUCH CONDITIONS. 5) HOMEOWNER SHALL BE RESPONSIBLE FOR CLEANING THE EFFLUENT FILTER ANNUALLY, OR AS NEEDED, TO PREVENT SEWAGE BACK UP. 6) PUMP AND ALL DRIP DISPERSAL SYSTEM COMPONENTS SHALL BE INSTALLED AND THE START UP OPERATION CERTIFIED BY OAKSON INC. SEPTIC SYSTEM PROFILE N.T.S. SOIL LOG DATE: MARCH 30, 2022 DATE: OCTOBER 20, 2022 SOIL EVALUATOR: DARREN MEYER CSE SOIL EVALUATOR: PETER McENTEE DESIGN CRITERIA SE-1542 ELEV. TP-1 DEPTH ELEV. TP-2 DEPTH NUMBER OF BEDROOMS: 3 BEDROOM EXISTING HOME 4.5 A 0" 4.9 A 0" SOIL TYPE: CLASS I MED. SAND MED. SAND DESIGN PERCOLATION RATE: <2 MIN./IN. 37 1OYR 4/1 10" 41 1OYR 4/2 10" DAILY FLOW: 330 G.P.D. B MED. SAND B MED. SAND DESIGN FLOW: 330 G.P.D. IOYR 5/8 1OYR 5/8 GARBAGE GRINDER: NO 2.7 26" 2.7 REDOX 26" C1 z C1 PROPOSED S.A.S.: PERC-RITE DRIP DISPERSAL SYSTEM UNDER MASSACHUSETTS DEP GENERAL USE APPROVAL MED. MED. SAND AN MED. SAND MED.7.5YAN 5/8 LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF .74 GPD/SF 1.5 STG. GW _ 36" r 1.9 STG. GW = 36" LEACHING AREA PROVIDED: 17' x 27' = 459 SF 0.8 44" 0.9 48" C2 C2 DRIP LINE LENGTH REQUIRED=(330 GPD)/(0.74 GPD/SF)/(2 SF/LF) = 222.4 LF MED. SAND MED. SAND (GENERAL APPROVAL) 400 LF (MIN. REQ'D), 432 LF PROVIDED 2.5Y 6/4 2.5Y 5/3 PROPOSED SEPTIC TANK: 1500 GALLON H-20 MONOLITHIC TANK PROPOSED PUMP CHAMBER: 1000 GALLON H-20 MONOLITHIC TANK -2 5 STANDING G.W. 84" 036" (EL.=1.5) -0.1 60" PUMP CHAMBER STORAGE CAPACITY PERC RATE 2 MIN/IN. ("C" HORIZON) STANDING G.W. 036" (EL.=1.5) 330 GALLON MINIMUM REQUIREMENT ESTIMATED HIGH GROUNDWATER, EL.=2.7 (REDOX) STORAGE VOLUME = (PC INVERT(IN) - PEAK ENABLE) x 250 GAL/FT STORAGE VOLUME = (4.00 - 2.04) x 250 GAL/FT = 490.0 GALLONS NOTE: ESTIMATED HIGH GROUNDWATER WAS OBSERVED AT 173 PINE GROVE ROAD TO BE ESTIMATED AT EL.=2.5 (REDOX) BY JC ENGINEERING, PLAN DATE 11/11/14 4" LOAM PLACED OVER SAND 2" OF SAND PLACED OVER DRIPUNE '.G. EL=7.2(MIN) DRIPUNES 12 IN. O.C.= 400 LF.(MINIMUM) ' (SEE DETAILS - SHEET 4) 16 LINES AT 27' 4V.=6.70 INV.=6.7D 4' MINIMUM DOSING SEPARATION TO GROUNDWATER SUGGESTED MUM DOSING WITH THE FOLLOWING PARAMETERS. 24 CYCLES/DAY AT 2.75 GPM/CYCLE FOR 5 MIN/CYCLE 24 x 2.75 x 5 = 330 GPD EST. HIGH G.W., SOIL ABSORPTION SYSTEM (PROFILE) F.G. EL=7.0 F.G. EL=7.2(MIN.)-\ 8,y F.G. EL-6.8 y 8' 12" 16 LINES AT 12" O.C. u 0 w FIELD WIDTH = 17' F.G. EL=6.5t EXISTING POLY UNER PROPOSED SEPTIC SYSTEM/SITE PLAN 175 PINE GROVE ROAD, SOUTH YARMOUTH. MA arepared for: Michael Farrell, 175 Pine Grove Rd, South Yarmouth, MA 0266A Engineero: Surveyoro: SCALE DRAWN JOB. NO. Engineering Works, Inc. R.A.S. associates N.T.S. P.T.M. 253-22 12 West Crossfield Road Forestdole, MA 02644 30 Carolyn Drive Plymouth, MA 02360 �TE CHECKED SHEET N0. (508) 477-5313 (508) 224-9035 13123 P.T.M. 3 Of 5 WIGGtN PRECAST CORP MODEL#TM1-5GGK-- I I I I I 1 � 1 4' NNOCICWTS 24" WL COVERS (TYP.) A 51-1/2" A J10 (TIP.) 1r-� PLAN VIEW 3- 24' COVERS 10'-2-1/2� 3 x 12 VENT IN 5'-11-1/2" ,\ 5'-3-1/2" 3' l GgNPARTMENT 1 IWNL AVNILNf (1/3 CWACM 54-1/2• �. REINFORCING RI8 UWID � 3' , 3-1/2' 9'-5-1/2" 9'-11-1/2" CROSS SECTION A -A SPECIFICATIONS 1.) CONCRETE 5,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO DEP TITLE V REGS. 310 CMR SECTION 15.226. 3.) REINFORCEMENT PER ASTM C1227-93. 4.) WEIGHT 13,966 LOS 5.) PROVIDE POLYMER COATING M sl_<<L�rl�7T�di11_��[�I�[•� 1500 GALLON MONOLITHIC SEPTIC TANK BOTTOM OF UNIT EL.= -0.29 HIGH GROUNDWATER EL.=2.7 BUOYANCY FORCE PER FOOT OF DEPTH: 10.2' x 6.1' x 1' x 62.4 lbs./cu.ft. = 3882.5 lbs. MAX. DISPLACEMENT = 2.70 - (-0.29) = 2.99' MAX. UPLIFT PRESSURE = 2.99' x 3882.5 Ibs/ft = 11,608.7 lbs. WEIGHT OF UNIT EMPTY = 13,99E lbs. 13,99E lbs > 11,609 Ilbs O.K. 1000 GALLON MONOLITHIC PUMP CHAMBER 4* KNOCKOUTS 24' OLl COMM 65 1 1 PLAN VIEW 8' INLET .. 4,I� OUTLET 72" 54-1/2" 48' 51-1/2" . REINFORCING RI8 AID 3' 3. tEVEI CROSS SECTION A -A SPECIFICATIONS 1.) CONCRETE 5,000 PSI AFTER 28 DAYS. 2.) CONSTRUCTION CONFORMS TO OEP TITLE V REGS. 310 CMR SECTION 15.228. 3.J REINFORCEMENT PER ASTM C1227-93. 4.)WeWeight10,554 5.) PROVIDE POLYMER COATING BOTTOM OF UNIT EL.= -0.64 HIGH GROUNDWATER EL.=2.7 BUOYANCY FORCE PER FOOT OF DEPTH: 8.3' x 5.5' x Vx 62.4 lbs./cu.ft. = 2848.E lbs. MAX. DISPLACEMENT = 2.70 - (-0.64) = 3.34' MAX. UPLIFT PRESSURE = 3.34' X 2848.E Ibs/ft = 9514.3 lbs. WEIGHT OF UNIT EMPTY = 10,554 lbs. 10,554 Ilbs > 4.514 lbs O.K. /2' PROPOSED SEPTIC SYSTEM/SITE PLAN 175 PINE GROVE ROAD, SOUTH YARMOUTH, MA >repared for: Michael Farrell, 175 Pine Grove Rd, South Yarmouth, MA 02664 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. R.A.S. associates N.T.S. P•T•M• 253-22 12 West Crossfield Road Forestdale, MA 02644 30 Carolyn Drive Plymouth, MA 02360 DATE CHECKED SHEET NO. (508) 477-5313 (508) 224-9035 1/3/23 P.T.M. 4 Of rJ TYPICAL SYSTEM HYDRAULIC PROFILE HOUSE NTS PUMP SEPTIC TANK/ TREATMENT UNIT INSTALLATION INSTRUCTIONS 1. Measure the distance from the bottom of the lank to 6" down from the lop of the riser. e Cut the extension pipe (by others) to the length necessary to reach this height. Cut 1/2 of the pipe down 12" to 18" away from the top of the pipe for pump discharge pipe. 12" to 18" away from the lop of the pipe for pump discharge pipe and attach to riser (see detail A). 2. Glue the extension coupling (by others) to the extension pipe and to the Cool Guide. 3. Far re —use of existing concrete pump chambers: glue on the Cool Guide flat cap and place the Cool Guide firmly in the bottom of the tank -Attach the extension to the riser, with the extension to the riser, with the anchors as shown. 4. For use in new concrete pump chambers: Anchor the flat cap to the bottom of the tank in the proper location to hold Cool Guide and extension. The cap may or may not be glued to the device. Attach the extension with the anchors as shown. 5. Place the pipe dope on the Cool Guide adopter threads and thread them into pump discharge. ADAPTER 6. Attach cooling collar to adapter with set screw provided. COOLNG COLLAR 7. Glue pipe into Dow collar and with pump attached, lower into the guide tube. 8. Attach to discharge pipe, valves, and connect electrical as specified. 1 1/2" SCH 40 COUPLING INLE o now Tw♦ 4mMOW � PVC IMT CAP Cod Oohs Patent No. 6.262.689 A MOAT ATTACH SEE General Construction Notes "Pere —Rite" Drip Dispersol Systems 1. The system shall not be installed in wet or frozen soils. 2. Do not park, drive large equipment, or store materials on the dispersal area. No activity should occur on dispersal area other than the minimum required to install the system. 3. All Installation and construction techniques shall conform to state and local codes pertaining to on —site sewage systems and the permit for the site. 4. The Installation shall be in accordance with specifications and procedures as supplied by the Manufacturer of the equipment. 5. The contractor shall be certified to install this type of system and should hold a pre —construction meeting with the individuals responsible for the site design and inspections. The meeting should be held prior to the beginning of the site work to ensure protection of the site conditions and to ensure that the system is installed according to design. 6. If site conditions are determined to require the installation of the system to deviate from the design plans, all work shall stop Immediately and the Designer and Health Agent shall be notified. Any ongoing work shall be the sole responsibility of the contractor. 7. Drip tubing may be installed with a vibratory plow, a static plow, a narrow trencher (<6" width). by hand trenching, or by scarifying the surface and bedding the drip tubing in clean sand meeting the requirements for fill material in Title 5 at 310 CMR 15.255(3) with cover consisting of send and topsoll meeting the 6' to 12" depth requirement. The designer may Indicate for the tubing to be installed up to 24" below grade. All drip tubing Is to be Installed parallel with the contour. Vegetative cover must be replaced for installations where it is removed or buried during installation. B. All cutting of rigid PVC pipe, flexible PVC and drip tubing of size 1 h" or smaller shall be accomplished with pipe cutters approved by Manufacturer. No sawing of PVC, flexible PVC or drip tubing of size 1 H" or smaller is allowed.All rigid PVC pipe, flexible PVC and drip tubing in thhge work o area shall how the ends covered with duct fore and cleared not toprevent detarisAll PVC aplipe and debris fitunga in then ileldeshaI be Prior SCHl 4l/.l All glueall d jointsints shall shall be inspected and primed with PVC primer prior to being glued.All force mains shall be tested for leaks prior to being backfilled by pressurizing the system and observing for leakage. 9. The Hydraulic Unit is to be placed on a bed of 4"— 6" thick oft;— lyz" grovel for drainage. If standing groundwater is o problem in the vicinity of the Hydraulic Unit, a screened drain to daylight is required. CAP CHECK VALVE /'AIR RELEASE VALVE 11' 50' 1' O.C. E 1 SUPPLY TYPICAL Z124 HYDRAULIC '-RETURN ZONE DETAIL ZONE SUPPLIES ZONE 1 r I ZONE 27 COMMON RETURN TO HYDRAULIC UNIT TYPICAL PUMP TANK & HYDRAULIC UNIT DETAIL NTS O=THE DAILY DESIGN FLOW FOR THE SITE (NOTE: IF THIS VOLUME IS NOT AVAILABLE MAXIMIZE STORAGE VOLUME IN TANK BY PLACING THE ALARM FLOAT AS CLOSE TO THE OUTLET ELEVATION AS POSSIBLE THEN PLACE PEAK ENABLE FLOAT HALF WAY BETWEEN THE ALARM AND DRIP ENABLE FLOATS rMH 80 UNION AM VALVE NO WEEP vx.UNCPON BOX Hao RF Daum RIGID FOAM INSULATION LINE FLUSH RETURN TO PUMP DISCHARGE TO HU MAMMUM gold Climate Construction Standards Perc—Rita" Drip Dispersal Systems 1. "Top feed" manifolds are to be used to allow for proper manifold drainage. Top feed manifolds are to be located slightly higher than the drip tubing. 2. All attempts should be made to place the Hydraulic Unit with an open southern exposure for warming purposes. 3. The supply and return lines shall be installed below the frost line. The vertical sections of pipe that connect to the supply and return lines shall be Insulated SCH 40 PVC pipe. Insulation shall be minimum i$" thick foam (or equivalent). yz" Rigid Foam insulation may be installed under the Hyroulic unit to protect the supply and return lines in extreme conditions. Sufficient ground cover around the hydraulic unit is required for Insulation. All pipes entering and leaving the hydraulic unit shall elbow vertically down 90 degrees to a depth below the frost line prior to extending away from the unit horizontally. Additional insulation inside the hydraulic unit is encouraged. Insulation to consist of blue board, bagged Styrofoam, peanuts or equivalent. If fiberglass isulotion is used it must be sealed to prevent it from becoming saturated. 4. Dense vegetative cover is to be established over the supply trench, return trench and drip tubing prior to the first exposure to freezing temperatures. If vegetation cannot be established. then trenches and tubing are to be covered with a thick layer (minimum 6") of mulch, straw/ hay, etc. until such turf cover is established. Established vegetation height over the dispersal area should be a minimum 4"-6" throughout winter months. 5. Contractor shall insulate all "air release valves." Insulation to consist of blue board, bagged styofoom peanuts, or equivalent. If fiberglass insulation is used, it must be sealed to prevent it from becoming saturated release valves shall be placed below the ground surface inside a valve box but at an elevation above the highest drip line in that particular zone. 6. All loops connecting drip runs shall be slightly elevated (minimum 1"— 2") so that they drain Into the drip tubing after the pump shuts off. It is the contractor's responsibility to ensure these loops stay elevated during and after the loops are backfilled. 7. All conduit entering into the control panel shall be sealed to prevent condensation inside the Supplied By: Re —Use, and Wastewater Products t 01930-2719 978-282-1322 1/2' PVC NOTE: 1. THE AIR RELEASE VALVES 2. EACH ZONE TO HAVE iAM INSERT SHALL BE PLACED AT THE TWO AIR RELEASE VALVES. ADAPTER HIGHEST POINT ON THE RETURN LINES TO BE VC np SUPPLY AND RETURN LINE CONNECTED A COMMON DAPTER FOR EACH ZONE. RETURN LINE. VALVE BOX WITH r MIN. RIGID FOAM INSULATION INSERTED UNDER ®V COVER DRIP I FWLD FROM DRIP TUBING C�, FAIR RELEASE VALVE NOTE; ALL DRIP LOOPS ARE TO BE LOCATED 2" ABOVE THE DRIP LINE TO ALLOW FOR THE LOOPS TO DRAIN HYDRAULIC UNIT HU NITS 6' OF GRAVEL STATIC UFT TO HU (MAX) FLUSH RETURN ZONE 1 SUPPLY - ZONE 2 SUPPLY CHECK VALVE LAST I ECTION CONNECTION ZONE 1 >\TOCOMMON FIRST LATERAL RETURN CONNECTION ZONE 2 elurn YP) TT )Id NOTE; ALL RIGID AND FLEXIBLE PVC ARE TO BE LOCATED ABOVE THE DRIP LINE TO ALLOW FOR THE PIPES TO DRAIN TYPICAL MANIFOLD CONNECTION PVC Primed Treaded Connection and Glued with Teflon Tape DRIP ENABLE FLOAT ELEVATION Flex Pie rip ubin Adapter Fitting Barbed Ram PVC FIP Insert Fitting I Connecting Drip Tubing to Flexible PVC Pipe NOTE THE DRIP TUBING SHALL BE THE LOWEST POINT TO ALLOW FOR DRAINAGE FROM BOTH THE VERTICAL INSULATED SUPPLY AND RETURN PIPES AIR RELEASE PRESwRIZED DRIP TUBING rLc1 PER DESIGN FORCE uplN \\� /�\ (PER COLD CLIMATE NOTES) INSTgLLATION DEPTH ] MAIN SUPPLY PIPE THE MOSTLLLIINE RETURNPIPE BELOW FROST LINE BELOW FROST LINE PROPOSED SEPTIC SYSTEM/SITE PLAN 175 PINE GROVE ROAD. SOUTH YARMOUTH. MA Prepared for: Michael Farrell, 175 Pine Grove Rd, South Yarmouth, MA 02664 Engineers: Surveyors: SCALE DRAWN JOB. NO. Engineering Works, Inc. R.A.S. associates NTS P.T.M. 12 West Crossfield Racal 30 Carolyn Drive Forestdole, MA 02644 Plymouth, MA 02360 DATE CHECKED SHEET NO. (508) 477-5313 (508) 224-9035 1/3/23 P.T.M. 5 of 5