Loading...
HomeMy WebLinkAboutEngineer PlanLEGEND BENCHMARK. • ASSUMED PROPOSED CONTOUR BULKHEAD CORNER ELEVA nON = 50.00 ® PROPOSED SPOT GRADE -- 98 -- EXISTING CONTOUR + 96.52 EXISTING SPOT GRADE N 4� W— EXISTING WATER SERVICE TEST PIT Gj�CD� 50 --- _--- _/r--�tD(1ST00 GAL. 0. SEP., TANK **EXISTING LEACHING SYSTEM WITHIN FOOT PRINT OF PROPOSED SYSTEM** (SEE NOTE 10) \ 5 FT SOIL REMOVAL ' EXIST. DWELLING #26 1 -� ���.- ti H �� �o EALTH DEP7 GENERAL NOTES: 1. ALL. CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL �i�` \�,_ BOARD OF HEALTH AND THE DESIGN ENGINEER. ���� 5� 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE. TITLE V. AND ANY APPLICABLE LOCAL RULES AND REGULATIONS. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR 1 TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. I % \� �\ BR 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. \\ �; \ 49 5. ALL ELEVATIONS BASED ON ASSUMED DATUM. ' \\ '\ BR BATH 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. \ 48 KIT 8. ALL AREAS DISTURBED DURING CONSTRUCTION SHALL BE RESTORED LIV. TO A CONDITION AGREED UPON BETWEEN OWNER AND CONTRACTOR. RM 9. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. "='mouth health Department 10. EXISTING LEACHING TO BE PUMPED, CRUSHED AND REMOVED PER TITLE V. SRO V JED GARAGE 11. 48 HOUR NOTICE FOR ENGINEER CERTIFlCATION 12. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY '^ Date 13. NO PRIVATE WELLS WITHIN 100 FT. OF PROPOSED LEACHING 14. ALL PIPING TO BE 4" SCH 40 A 1/8"/FT (UNLESS SPEC. OTHERWISE) 15. THE DESIGN OF THIS SYSTEM DOES NOT ALLOW FOR THE USE OF A GARBAGE GRINDER 16. NO WETLANDS WITHIN 100 FT. OF PROPOSED LEACHING 17. UNSUITABLE SOILS TO BE REMOVED 5 FT AROUND LEACHING TO EL 47.22 FLOOR P L A N OR TOP OF "C" SAND LAYER AND REPLACE WITH CLEAN MEDIUM SAND PER TITLE 5. W. YARMOUTH GRAY RD. LOCUS MAP LOCUS INFORMATION PARCEL ID: MAP 58 PAR. 100 TITLE REF: LCC 155278 PLAN REF: LCP 33984-A PARCEL IS NOT WITHIN ZONE OF CONTRIBUTION SEPTIC SYSTEM REPAIR PLAN LOCATED AT: 26 HARDING LANE WEST YARMOUTH, MA PREPARED FOR FOLEY/CAPE COD SEPTIC JUNE 27, 2023 OF U,�, ��TSTONE D R N M Gn ���$� Q �N RRN NFL NOS" MEYER & SONS, INC. P.O. BOX 981 EAST SANDWICH, MA. 02537 PH: (508)360-3311 FAX: (774)413-9468 meyerandsonstitle5@gmail.com SHEET 1 OF 2 NOTE: TO PREVENT BREAKOUT, THE PROPOSED NOTE: MAGNETIC TAPE TO BE PLACED OVER ALL COVERS FINISH GRADE SHALL NOT BE < EL:48.17 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. SEPTIC TANK PROPOSED D-BOX PROPOSED S.A.S. T.O.F. EL=51.00 INSTALL RISERS & COVERS OVER INLET & INSTALL RISER & COVER INSTALL A 4" DIAMETER INSPECTION PORT OVER ����� OF W�SS'y OUTLET AND SET TO 6" OF FINISH GRADE SET TO 6" OF GRADE ONE CHAMBER (MIN.) AND SET TO 3" OF F.G. VENT �� ARRE cis -F.G. EL=49.70t F.G. EL=49.7t F.G. EL: 49.70t F.G. EL: 49.80(MAX.) No.1140 9" MIN COVER/ p 36" MAX COVER ; L = 4' L - 11'(MA INSTALL TWO INSPECTION PORTS (MIN.) FGIsTER� ® S=1X (MIN.) Q S=1X (MIN.) m S=1X (MI .) SANITARIN� 4"SCH40 PVC 4"SCH40 PVC 4"SCH40 PVC 10" 14 s 3.3` TO 6* 1- 1 M 3 48" 1011D INVERT cEvra INV.=48.10 GAS BAFFLE PROPOSED INV.=47.89 4 ROWS OF 6 UNITS AT 4.0'/UNIT = 24.0'/ROW D-BOX INv.=48.0 DB- INV.= 47.78 SOIL ABSORPTION SYSTEM (PROFILE) 'M AM AM AREXISTING 1.500 GALLON SEPTIC TANK RESTORE EXISTING SEWER OUTLET �i- B77-7 ACKFlLL WITH nCLEANVE OPERRC SAND ' NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2) 3) REPLACE EXIST 1,5000 SEPTIC TANK W/NEW 1.50OG SEPTIC TANK IF FAILED OR DAMAGED. 4) INSTALL INLET & OUTLET TEES W/ GAS BAFFLE AS REQUIRED BREAKOUT=TOP ELEV.=48.17 ` INV. ELEV.= 47.78 BOTTOM ELEV.= 47.50 PLACE FILTER FA IC OVER UNITS PRIOR TO EJACKFILL 0 PLACE GEO-GRID UNDER CHAMBER UNITS 5' MIN. ABOVE BOTTOM OF I-- T.P. EXCAVATION OR G.W. EFFECTIVE WIDTH = 4 x 2.83' = 11.32 (5.03' PROVIDED) USE 4 ROWS OF 6 INFILTRATOR QUICK 4 PLUS ADJ. GROUNDWATER EL=42.47 _ STD LP (3.3" INVERT) UNITS -NO STONE SEPTIC SYSTEM PROFILE N.T.S. DESIGN CRITERIA **PROP IS NOT IN ZONE OF CONTRIBUTION** NUMBER OF BEDROOMS: 3 BEDROOM DESIGN - SOIL TEXTURAL CLASS: CLASS I DESIGN PERCOLATION RATE: <2 MIN/IN DAILY FLOW: 330 G.P.D. DESIGN FLOW: 330 G.P.D. GARBAGE GRINDER: NO (NOT DESIGNED FOR GARBAGE GRINDER) PROPOSED SEPTIC TANK: 330gpd x 200% = 660 gpd (USE EXIST. 1,50OG CAPACITY) LEACHING AREA REQUIRED: (330) = 445.95 S.F. .74 DISTRIBUTION BOX: (4 OUTLETS (MINIMUM)) PRIMARY S.A.S. USE 4 ROWS OF 6 - INFILTRATOR QUICK 4 STD LP (3.3" INVERTS UNITS WITH NO STONE BOTTOM AREA: (GENERAL USE APPROVAL FOR4.73 SF/LF OF CHAMBER) (CHAMBER UNITS) 24 UNITS x 4.00 LF x 4.73 SF/LF = 454.08 SF TOTAL AREA = 454.08 SF DESIGN FLOW PROVIDED: 0.74GPD/SF(454.08SF) = 336 GPD > 330 GPD I TYPICAL SECTION wT& SOIL LOGS DATE: JUNE 14, 2023 SOIL EVALUATOR: DARREN MEYER, R.S., CSE #1614 WITNESS: JAY GARDNER, YARMOUTH HEALTH Elev. TP-1 Depth 49.80 A 0" LOAMY SAND IOYR 48.80 12" B LOAMY SAND 10YR 5/8 47.22 31" C WELL MIW-89, ZONE A LEVEL 7.96. ADJUSTMENT: 1.5 FT MEDIUM E BOH ALLOWED ADJUSTMENT OF 1.0 FT. SAND 2.5Y 7/4 ADJUSTED GROUNDWATER EL 42.47 40.22 115" PERC RATE 2 MIN AN. ("C" HORIZON) GROUNDWATER OBSERVED AT 100% EL 41.47 q'd * I, Darren M. Meyer. R.S., CSE, hereby certify that 1 am currently approved by MADEP pursuant to 310 CMR 15.017 to conduct soil evaluations and that the above analysis has been performed by me consistent with the requirements of 310 CMR 15.017. 1 further certify that I have passed the Soil Evai. Exam In October, 1999. .8 SEC11ON END CAP INFILTRATOR QUICK 4 PLUS STD LP (3.3" INVERT) UNITS PROPOSED SEPTIC SYSTEM SITE PLAN 26 HARDING LANE, W. YARMOUTH, MA Prepared for: Foley/Cape Cod Septic Design and Site Plan by: SCALE DRAWN DATE: MEYER&SONS, INC. NTS D.M.M. 06/27/23 PO BOX 98! EASTSANDWICH.MA02537 CHECKED SHEET N0. 508,W-2922 D.M.M. 2 of 2