Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot C 97„70 Zone of Contribution: In_ Out Acreage Commercial: Residential: Street: AV s- - ;� _____ Village: <,' I"`✓rr��w � Floor Plan: tt Bedrooms: p Owner: (�,,� . y;,,,,-,0 Installer: 4 ,/j. (�. Address: : i,5 •�,-fe, , -, �,, Phone: t Phone: Sv'f' /3 t k Buil Address:er: Engineer: SC e t��f,,.t02 Phone: Phone: s,6-- 3, us, 7-7 NIA YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older.than 2 years -- 3. 4-5 ft of naturally occurring pervious material, above water table _- - 4. Foundation 2 ft above high h point of road H.P.: Fnd: Var.: � _ 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: L I 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: \` 13. Uses adjustment for maximum high groundwater Var.: tom' 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: V 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable V 17. System meets slope requirements-min. 1/8", %"preferred _18. System meets breakout requirements PVC liner: Wall: • 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal 22. System adequately sized for its intended use t� 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade J 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes ✓. 27. Pump system-2"line,weep hole,check valve, tee in dbox,pump size 1.4 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking V 30. Buoyancy calculations for lank/pump chamber/ 31. Engineer to inspect and certify I 4./ fy soils: :/wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33. H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house / 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwaterfLAbel groundwater in Assessor's Map ( ✓ I Plan reviewed by: . I _ ; )(r ) co:o; /� t