HomeMy WebLinkAboutReview Checklist TOWN OF YARI<IOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot CS,
Zone of Contribution: In_ Out_ Acreage
Commercial: Residential:
Street: 5'... za,�.a� �� /`____
Village:t,�). ;;,-,.,,,,,,... // Bedrooms: 2-j
Floor Plan:
Owner: fl/c y �/E'p't.e` , a('2?f Installer: .�, '' /e -/;
Address: � �' �'`-
SS 41,-4 it a 1 y am= Phone: 5`z - 77 5-7-9'S f"
Phone: US. 36 y- �03.
Builder: n•
Engineer: Al c_‘6,fi-J Se A,2
Address:
Phone: .,�;
Phone:
1. Required#of copies received N.'A YES I NO
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ' ..-
5. Water line 10 ft from septic components Var.: I -
6. Benchmark indicated and shown-NGVD if near wetlands ( 6.---
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands
Var.: I
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: \`
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: i✓
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable L./
17. System meets slope requirements-min. 1/8", 'A"preferred /7✓
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel /
21. No garbage disposal
22. System adequately sized for its intended use Z
23. Minimum 6"stone or compacted below tank and dbox • I 1
24. Manhole covers within 6"of grade, pump chamber cover to grade I /
25. Inspection port on plastic chambers/leach field J V
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pumpsystem-2" `�
Yline,weep hole,check valve, tee in dbox, pump size ✓' -
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking I
30. Buoyancy calculations for'tank/pump chamber • k'
inspect and certifyV
31. Engineer to
, soils: ilwall: commercial: I ,/
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature E.,/
35.Foundation footing min_ 2 feet above adjusted ground water for new house ;ice
36. Deed Restriction required max. #bedrooms: max. flow:
37. Check area lots for groundwater/Label oundwater in Assessor's Ma gpd
Plan reviewed b}: -- _,2G:)3