HomeMy WebLinkAboutReview Cheklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot 9 C)-30 Zone of Contribution: In_ Out_ Acreage
Street: Commercial: Residential:
l� 1� f,
Village: j. i 2lr ,ti ft„.
Floor Plan: # 3
JBedrooms:
Owner: Pe G,,NQr Installer: e.g 0.
Address: l,) /# 14 t . S. 'J, „,4.4. Phone:
Phone: id) yG '�' s 3
Builder:
Address: Engineer: _i( [y-t er.,N-5
Phone: Phone: - d 3037-7
1. Required#of copies received N A NO
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table 4. Foundation 2 ft above highpoint of road g H.P.: Fnd: Var.: v -----
5. Water line 10 ft from septic components Var.: -
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.: /
12. System meets all other setback requirements Var.: 1/
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole •Var.: V
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", IA"preferred '�
18. System meets breakout requirements PVC liner: Wall: 1 lell
19. S.ecified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 .d for .arcel A__
21. No 'arbaae dis.osal
22. System ade uately sized for its intended use NM
23.Minimum 6"stone or corn.acted below tank and dboxNMI
24. Manhole covers within 6"of grade, pump chamber cover to grade Mil-
25. Ins.ection sort on .lastic chambers/leach field
26. Electrical .ermit for sum. chamber/Se.arate meter for du.lexes ��-
27. Puma system-2"line,wee. hole,check valve, tee in dbox, .ump size iffillIMMIIIIIM
�__
28. Se.tic tank/.um, chamber to be factory wate 'roofed
29. Vent .rovided if leaching below 3 feet,under driveway/parking MI NU
30. Buo ancy calculations forlank/.um. chamber
31. Engineer to ins.ect and certify soils: v
32. EnGineer/Re:istered Sanitarian and Land Surveyor stam.s/signature commercial: All
111=1-
33.H-20 loading is sub-ect to vehicular traffic, Groundwater
_
34.Title V Application and .ermit fee, installer signature
35. Foundation footing min. 2 feet above adjusted Ground water for new house �_-
36. Deed Restriction re.uired max. __
37. Check area lots for groundwater/Label ground bedrooms:
Assessslas Max. . d -_
Plan reviewed by: �� _