Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDSM-22-007418
A RECEIVED JUN 22 2022 itr*- SHEET METAL PERMIT i Commonwealth of Massachusetts B E - e,„ ei .' Town of Yarmouth Building Department 1146 Route 28, South Yarmouth, MA 02664-4492 Date: 0 7 2 / (Z, 2 Permit#: ftS111-a a-Lt74I - Estimated Job Cost: $ Z ci�-.= Permit Fee: $ Plans Submitted: NO Plans Reviewed: YES/ NO Business License# C - 3 S� Application License# ,s—(7,6 Business Information Property Owner/Job Location Information Name: AIL 2, 1-(VA c Name: {l-'r,4 4 S &2e—' _ Street: 8 w f /`i/l f ., Street: ( Z 540 t,,,a z/'S t,-' City/Town: A/ 0 NN/j (p()I City/Town: 5.o J'- �, yAlL,-(0 Telephone: c J-300 -7(o(Z Telephone: 5-ocf_ 3,6 7 r,S 3 r Photo I. quired/Copy of Photo I.D. attached: 6/NO Staff Initial: -1/M- unrestricted license J-2/M-2 restricted to dwellings 3 stories or less and commercial up to 10,000 sq.ft./2 stories or less Residential: 1-2 family ulti-family Condo/Townhouses Other_ Commercial: Office Retail Industrial� Educational Institutional Other Square Footage: under 10,000 sq. ft.L 6 r 10,000 sq.ft. Number of stories: Sheet metal work to a completed: New work/' Renovation:—HVAC: Metal Watershed Roofing: Kitchen Exhaust System: Metal Chimney/Vents:_Air Balancing:_ Provide detailed description of work to be done: tn.s4-A-// . ,26 th..s,/9,) >4 - \-, I-e J Cs/ �a-rI �2,.cJ >c zc 4 - ,4, (a,j4 1F/ 6,s-cy /i f.14. INSURANCE COVERAGE: I have a current liability insuranc olicy or its equivalent which meets the requirements of M.G.L. Ch. 112 Yes No If you have checked Yes, indicate the/type of coverage by checking the appropriate box below: A liability insurance policy 1- Other type of indemnity Bond OWNER'S INSURANCE WAIVER:I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. Check One Only Owner - Agent Signatu Ow ner's Agent By chec - ,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and,/- . e to the best of my knowledge and that all sheet metal work and installation performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Inspections shall be called for prior to insulation installation. Duct inspection required prior to insulation installation: Yes , No Progress Inspections Date: Comments: Final Inspections Date: Comments: Type of license: By: Master Title: Master-Restricted IN Signature of Licensee'1` City/Town: Journeyperson Permit#: Journeyperson-Restricted License Number: Fee: $ Check at www.mass.gov/dpl Inspector Signature of Permit'(` of Permit Approval • 7 ''---- ‘;,„.,..--...;i.AM:_M......°. . c''' ,--•--••.•.L...'-..-.T .....,,..,...,: O: ,.. F:"-A-7.•. A-'..:.- a. .'...g -A O-::':.:,•;' " b.-.:?•,.-:...:.:•.S DIVISION OF OCCUPATIONAL LICE \7" u.:::....'.„.:.......R...'.:...„::'•E • BOARD OF SHEET METAL WORKERS ES THE FOLLOWING LICENSE *:MASTER-UNRESTRICTED .:..:&.:..:..,..:.:.. •,..,••,•A4I1i,."i --;c'*"' .'.;•;• .:.'.1::'.!.... .. .... .. \t: ZOCANTE Rio, G i t.., FA". RD- 2.366, '..•.-'' .. ' :.- :.!:-.,::::: 330 ELLIOTT,. .. ...;.... om.......,,,,.. ,...i-.......1: .... ---...tie,MA •-:''.:.-.:;.''' ..... ..'::,::-•-• EF(VI •-• - CENT .. - ' .:, ...?. :.'•.•--::2,;•:::':."::::.,,,•;.1:0:-i•:1-.:.•:''. 6 . . .'..., •• 0712812024.-.. •• 247474 LICENSE NUMBER EXrIRATI„, DATE SERIAL NUMBER BE3 , .. . ,' , : .,, ..'•- RI'1,1,-''7 E t 2, - k , ---e'-`,,`'"'-"I :";." -- '-''''.",,,•-•_.,!. -:: — . „4„-.L.- .,,;-.erk' • ....,0- ,,,,,-.:',Z .,,„;-'- • NONE.n - .: ,, ,f.--_-,-: ..,.._ ,.. w.,, D. .. ':-4tirl 4,.--1 'il -..i ._ ..,„..,,!,....;,.. , .,.. :--,,.-. ,,_ .. ....., ,.. *'-:-,- 2F::‘,:itY,',',1 /24518 .- • A CERTIFICATE OF LIABILITY INSURANCE DATE(MM/DDIYYYI) 04/12/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Tina Reeves NAME: Dowling&O'Neil Insurance Agency PH do ). (800)640-1620 I jaC,No): 973 lyannough Road ADtADARYE.as: Neves(gdoins.com INSURER(S)AFFORDING COVERAGE NAIC S Hyannis MA 02601 INBBBEBA: Hartford Casualty Ins.Company 29424 INSURED INSURER B: NGM Insurance Company 14788 Air Rite HVAC Inc. INSURER C: 330 Elliott Rd. INSURER D: INSURER E: Centerville MA 02632 INSURER F: COVERAGES CERTIFICATE NUMBER: CL224406798 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. LICY EXP LTRR TYPE OF INSURANCE INSD WVD POLICY NUMBER (M WBR M/LDDIYYYY) (MY/DD/YYYY) UMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE TO RENTED 1,000,000 CLAIMS-MADE El OCCUR PREMISES(Ea occurrence) $ MED EXP(Any one person) $ 10,000 — A 08SBAAR7BPZ 04/13/2022 04/13/2023 PERSONAL&ADV INJURY $ 1'000,000 — GEN'LAGGREG R ATE LIMAPPLIES PER: GENERAL AGGREGATE $ 2'000, r� 000 POLICY 15 M pi 0 LOG PRODUCTS-COMP/OP AGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILfY (Es IINdE�DtSINGLE UMIT $ 1,000,000 — ANY AUTO BODILY INJURY(Per person) $ B i OWNED X SCHEDULED M1T8454A 04/13/2022 04/13/2023 BODILY INJURY(Per accident) $ AUTOS ONLY HIRED Ne NON-OWNED PROPERTY DAMAGE $ OS X AUTOS ONLY X AUTOS ONLY (Per accident) $ X UMBRELLA UAB OCCUR EACH OCCURRENCE $ 2,000'000 A - EXCESSUAB CLAIMS-MADE 08SBAAR7BPZ 04/13/2022 04/13/2023 AGGREGATE $ 2.000,000 DED Xl RETENTION$ 10,000 $ WORKERS COMPENSATION X1 STATUTE I I ERR- AND EMPLOYERS'LIABILITY Y/N A ANY PROPRIETOR/PARTNER/EXECUTIVE N/A O8WECAR7EUL 04/13/2022 04/13/2023 E.L.EACH ACCIDENT $ '000 OFFICER/MEMBER EXCLUDED? 500,000 (Mandatory In NH) EL.DISEASE-EA EMPLOYEE $ Byes,describe under 500,000 DESCRIPTION OF OPERATIONS below EL.DISEASE-POLICY UMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(ACORD 101,Additional Remarks Schedule,may be attached I more space is required) Insurance coverage is limited to the terms,conditions,exclusions,other limitations and endorsements.Nothing contained in the certificate of insurance shall be deemed to have altered,waived,or extended the coverage provided by the policy provisions. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN Town of Yarmouth ACCORDANCE WITH THE POLICY PROVISIONS. 1146 Route 28 AUTHORIZED REPRESENTATIVE South Yarmouth MA 02664 �'� I m 1988-2015 ACORD CORPORATION. All rights reserved. ACORD 25(2018/03) The ACORD name and logo are registered marks of ACORD , .4 wrightsof• Project Summary Job: 12 SALT WORKS Date: Jun 21,2022 Entire House By. JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA Pro"ect Information For: TOM GREW 12 SALT WORKS LN, SOUTH YARMOUTH, MA Notes: Desi• n Information Weather: Barnstable Muni Boa, MA, US Winter Design Conditions Summer Design Conditions Outside db 14 °F Outside db 81 °F Inside db 72 °F Inside db 70 °F Design TD 58 °F Design TD 11 °F Daily range L Relative humidity 50 Moisture difference 46 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 26248 Btuh Structure 18128 Btuh Ducts 9830 Btuh Ducts 7695 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36078 Btuh Use manufacturers data n Rate/swing multiplier 0.86 Infiltration Equipment sensible load 22285 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3683 Btuh Ducts 1489 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1572- 1572 Equipment latent load 5173 Btuh Volume(ft3) 12576 12576 Air changes/hour 0.50 0.26 Equipment Total Load(Sen+Lat) 27458 Btuh Equiv.AVF(cfm) 105 54 Req.total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 0 HSPF Efficiency 0 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1416 cfm Actual air flow 1416 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Ca pacity ba lance point=-32°F Backup:n/a n/a Input=0 kW, Output=0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �i,_ w � E 2022-Jun-21 15:35:44 �T _ Right-Suite®Universal 2022 22.0.03 RSU22010 Page 1 ...comtDocuments1Wrightsoft I-VAC\12 SALT WORKS.rup Cat=MJ8 Front Door faces: W . wr sof • Project Summary Job: Ju SALT WORKS . 1 � Date: Jun 21,2022 1ST FLOOR ZONE By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA Project Information For: TOM GREW 12 SALT WORKS LN, SOUTH YARMOUTH, MA Notes: Desi• n Information Weather: Barnstable Muni Boa, MA, US Winter Design Conditions Summer Design Conditions Outside db 14 °F Outside db 81 °F Inside db 72 °F Inside db 70 °F Design TD 58 °F Design TD 11 °F Daily range L Relative humidity 50 % Moisture difference 46 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14171 Btuh Structure 11628 Btuh Ducts 5307 Btuh Ducts 4936 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 19478 Btuh Use manufacturer's data n Rate/swing multiplier 0.86 Infiltration Equipment sensible load 14295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2042 Btuh Ducts 773 Btuh Central vent(0 cfm) 0 Btuh HeatingCooling Area(ft2) 816 816 Equipment latent load 2815 Btuh Volume(ft3) 6528 6528 Air changes/hour 0.48 0.25 Equipment Total Load(Sen+Lat) 17109 Btuh Equiv.AVF(cfm) 52 27 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. • •-•- -M---- RightSuite®Universal 2022 22.0.03 RSU22010 2022-Jun-21 15:35:44 itk ...com\Documents\Wrightsoft HVAC\12 SALT WORKS.rup Caic=MJ8 Front Door faces: W Page 2 .41. wrightsoft. Project Summary Job: 12 SALT WORKS Date: Jun 21,2022 2ND FLOOR ZONE By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER.MA Project Information For: TOM GREW 12 SALT WORKS LN, SOUTH YARMOUTH, MA Notes: Desi•n Information Weather: Bamstable Muni Boa, MA, US Winter Design Conditions Summer Design Conditions Outside db 14 °F Outside db 81 °F Inside db 72 °F Inside db 70 °F Design TD 58 °F Design TD 11 °F Daily range L Relative humidity 50 % Moisture difference 46 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 12077 Btuh Structure 8096 Btuh Ducts 4523 Btuh Ducts 3437 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16600 Btuh Use manufacturer's data n Rate/swing multiplier 0.86 Infiltration Equipment sensible load 9953 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1642 Btuh Ducts 716 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft2) 756 756 Equipment latent load 2358 Btuh Volume(ft3) 6048 6048 Air changes/hour 0.52 0.27 Equipment Total Load(Sen+Lat) 12310 Btuh Equiv.AVF(cfm) 52 27 Req.total capacity at 0.70 SHR 1.2 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Aft .®' wripl o}!- w _ Right-Suite®Universal 2022 22.0.03 RSU22010 2022-Jun-21 15:35:44 ...comtDocuments1Wrightsoft HVAC\12 SALT WORKS.mp Caic=MJ8 Front Door faces: W Page 3 AED Assessment Job: 12 SALT WORKS W!' 1t50 Date: Jun 21,2022 Entire House By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA Project Information For: TOM GREW 12 SALT WORKS LN,SOUTH YARMOUTH, MA Design Conditions Location: Indoor: Heating Cooling Barnstable Muni Boa, MA, US Indoor temperature(°F) 72 70 Elevation: 56 ft Design TD(°F) 58 11 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 26.0 45.5 Dry bulb(°F) 14 81 Infiltration: Daily range(°F) - 14 ( L ) Wet bulb(°F) - 71 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity 1-buiy Gazirg Load 11,000-- 10,000- 9,000- 8,000- 7,000— 6,000-- 5,000--- 4,000- 3,000- 2,000- 1,000- 0 1 I I I I I I I I 8 9 10 it 12 13 14 15 16 17 18 19 20 wuraoey It* ♦AMR" /AED 1'mN Maximum hourly glazing load exceeds average by 15.6%. House has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 0 Btuh we'i oft- 2022-Jun-2115:35:44 A1/4 Right-Suite®UUniversal 2022 22.0.03 RSU22010 Page 1 ...com\Documents\Wrightsoft HVAC\12 SALT WORKS.rup Cale=MJ8 Front Door faces: W yy AED Assessment Job: 12 SALT WORKS 1ST FLOOR ZONEDa By: Jun 21,2022 JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA Project Information For: TOM GREW 12 SALT WORKS LN, SOUTH YARMOUTH, MA Design Conditions Location: Indoor: Heating Cooling Barnstable Muni Boa, MA,US Indoor temperature(°F) 72 70 Elevation: 56 ft Design TD(°F) 58 11 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 26.0 45.5 Dry bulb(°F) 14 81 Infiltration: Dailyrange(°F) - 14 ( L ) Wet bulb(°F) - 71 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity 1-buly tr1g Load 6,000- 5.500- 5,000- 4,500- 4,000- 3,500- 3,0 2,500- 2,000- 1,500- 1,000- 500— 0 8 9 10 11 12 13 14115 18 17 18 19 20 �A•'� i AED Mril Maximum hourly glazing load exceeds average by 18.7%. Zone has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 1115 Btuh (PFG -ALP) 1N 2022-Jun-21 15:35:44 Right-Suite®Universal 2022 22.0.03 RSU22010 Page 2 ...comlDocuments\Wrightsoft HVAC112 SALT WORKS.rup Cad=MJ8 Front Door faces: W AED Assessment Job: 12 SALT WORKS wriotsoft. 2ND FLOOR ZONE Date: Jun 21,2022 JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA Project Information For: TOM GREW 12 SALT WORKS LN, SOUTH YARMOUTH, MA Design Conditions Location: Indoor: Heating Cooling Barnstable Muni Boa, MA, US Indoor temperature(°F) 72 70 Elevation: 56 ft Design ID(°F) 58 11 Latitude: 42°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(grub) 26.0 45.5 Dry bulb(°F) 14 81 Infiltration: Dailyrange(°F) - 14 ( L ) Wet bulb(°F) - 71 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Italy Clazirg[sad 4,500- 4,000— 3,500-- 3,000- 2,50 2,000- 1,500- 1,000- 500— 0 8 9 1I0 III 112 1I3 1I4 1I5 1I6I 171 1I8 9 20 Ha,drkay ,1* kerp, i AED Rxut Maximum hourly glazing load exceeds average by 11.4%. Zone has adequate exposure diversity(AED), based on AED limit of 30%. AED excursion: 481 Btuh (PFG -ALP) 41111- 2022-Jun-21 15:35:44- Right-Suite®U niversal 2022 22.0.03 RSU22010 Page 3 ...com\Documents\Wrightsoft HVAC112 SALT WORKS.rup Caic=MJ8 Front Door faces: W 'Iiks wrIghttsoft Right-J® Worksheet Job: 12 SALT WORKS Entire House Date: Jun 21,2022 JIM GRIFFITS By: 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name Entire House 2ND FLOOR ZONE 2 Exposed wall 232.0 ft 116.0 ft 3 Room height 8.0 ft 8.0 ft 4 Room dimensions 5 Room area 1572.0 ft' 756.0 ft' I I I I I I Ty Construction U-value Or HTM Area (ft') Load I Area (ft') Load number (Btuh/ft'-"F) I (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S Heat I Cool I Gross N/P/S Heat Cool I 6 w12C-0sw 0.091 n 528 1.89 544 468 2470 884 272 240 1267 453 I--C 1D-c20v 0.570 n 33.06 17.17 76 0 2513 1305 32 0 1058 549 1 1 b12G05w 0.091 e 5.28 1.89 384 315 1663 595 192 168 887 317 1D-c2ov 0.570 e 33.06 59.07 48 0 1587 2835 24 0 793 1418 tux 0.390 e 22.62 10.04 21 21 475 211 0 0 0 0 W 12C-Osw 0.091 s 5.28 1.89 144 120 633 227 0 0 0 0 1-G 1D-c2ov 0.570 s 33.08 30.49 24 0 793 732 0 0 0 0 W 12GOsw 0.091 s 5.28 1.89 400 388 2048 733 272 260 1372 491 i-G 1 D c2ov 0.570 s 33.06 30.49 12 0 397 366 12 0 397 366 w 12G0sw 0.091 w 5.28 1.89 96 63 333 119 0 0 0 0 �--G 1D-c2ov 0.570 w 33.06 59.07 12 0 397 709 0 0 0 0 LLL-----DDD 11D0 0.390 w 22.62 10.04 21 21 475 211 0 0 0 0 12C-Osw 0.091 w 5.28 1.89 288 264 1393 498 192 180 950 340 1D-c2ov 0.570 w 33.06 59.07 24 0 793 1418 12 0 397 709 C 16A-30ad 0.032 - 1.86 2.22 528 528 980 1170 528 528 980 1170 C C Dart ceiling. 0.048 - 2.81 2.38 288 288 809 687 228 228 640 544 F 19A-19bscp 0.049 - 2.23 0.43 96 96 214 42 0 0 0 0 F 19A-19bstp 0.049 2.23 0.43 72 72 160 31 0 0 0 0 F 19A-19bswp 0.049 - 2.23 0.43 360 360 802 156 0 0 0 0 F 19A 19bswo 0.049 - 2.23 0.43 288 288 641 125 0 0 0 0 481 I 6) Envelope loss/gain I 195761 130521 I 8741 6838( 12 a) Infiltration 6673 676 3336 338 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 10 2300 4 920 Appliances/other 2100 0 Subtotal(lines 6 to 13) 26248 18128 12077 8096 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 26248 18128 12077 8096 15 Duct loads 37% 42% 9830 7695 37% 42% 4523 3437 Total room load I I I 361471861 25826I I I t665�1 I 116533321 163 I I Air required(cfm) Calculations aaoroved by ACCA to meet all reauirements of Manual J 8th Ed. -44i- v s l*?S- 2022-Jun-21 15:35:45 Right-Suite®U niversal 2022 22.0.03 RSU22010 Page 1 ...comtDocuments\Wrightsoft HVAC112 SALT WORKS.rup Calc=MJ8 Front Door faces: W *wrightsoft' Right-A) Worksheet Job: 12 SALT WORKS Entire House Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name 1ST FLOOR ZONE 2 Exposed wall 116.0 ft 3 Room height 8.0 ft 4 Room dimensions 5 Room area 816.0 ft' i Ty Construction U-value Or IiTM Area (ft') Load Area Load I number '(Btuh/ft'-*F I I (Btuh/ff) I or perimeter (ft) (Btuh) I or perimeter IHeat I Clo I Gross N/P/S Heat I Cool I Gross I N/P/S I Heat Cool I 6 W 12C-Osw 0.091 n 5.28 1.89 272 228 1203 431 I-�3 1 Dc2ov 0.570 n 33.06 17.17 44 0 1455 755 12C-Osw 0.091 e 5.28 1.89 192 147 776 278 1D-c20v 0.570 e 33.06 59.07 24 0 793 1418 11 11 D0 0.390 e 22.62 10.04 21 21 475 211 W 12C-Osw 0.091 s 5.28 1.89 144 120 633 227 i-C 1D-c2ov 0.570 s 33.06 30.49 24 0 793 732 W 12C-Osw 0.091 s 5.28 1.89 128 128 676 242 r---G 1 D-c2ov 0.570 s 33.06 30.49 0 0 0 0 Iii 12C-0sw 0.091 w 5.28 1.89 96 63 333 119 1 Dc2ov 0.570 w 33.06 59.07 12 0 397 709 11 D0 0.390 w 22.62 10.04 21 21 475 211 V�f 12C Osw 0.091 w 5.28 1.89 96 84 443 159 r G 1D c2ov 0.570 w 33.06 59.07 12 0 397 709 C 18A-3Oad 0.032 - 1.86 2.22 0 0 0 0 C C part ceiling. 0.048 - 2.81 2.38 60 60 169 143 F 19A-19bscp 0.049 - 2.23 0.43 96 96 214 42 f 19A-l9bstp 0.049 - 2.23 0.43 72 72 160 31 F 19A-19bswp- 0.049 - 2.23 0.43 360 360 802 156 F 19A-19bswo 0.049 - 2.23 0.43 288 288 641 125 6 I Envelope loss/gain I I I 10835 781C1 I 12 a) Infiltration 3336 338 b) Room ventilation 0 0 13 Internal gains: Occupants© 230 6 1380 Appliances/other 2100 Subtotal(lines 6 to 13) 14171 11628 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 14171 11628 15 Duct loads 37% 42% 5307 4936 I I Total Airrequired room load(cfm) I I I 19478 1665E0481 I I I Calculations approved by ACCA to meet all reouirements of Manual J 8th Ed. w' _. 2022-Jun-21 15:35:45 -_. Right-Suite®U niversal 2022 22.0.03 RSU22010 Page 2 ...com\Documents\Wrightsoft HVAC\12 SALT WORKS.rup Calc=MJ8 Front Door faces: W -4 wrIghtsoft Right-J® Worksheet Job: 12 SALT WORKS 1ST FLOOR ZONE Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR.BREWSTER,MA 1 Room name 1ST FLOOR ZONE BED 1 2 Exposed wall 116.0 ft 24.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions , 144.0 ft'12 0 x 12.0 ft 5 Room area 816.0 ft I r I I Ty Construction U-value Or I-TM Area (ft') Load I Area (ft') Load number (Btuh/ft'-'F I (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool 1 Gross I WP/S Heat I Cool I 6 W 12C-Osw 0.091 n 5.28 1.89 272 228 1203 431 98 84 4431 159 L--G 1 D.c2ov 0.570 n 33.06 17.17 44 0 1455 755 12 0 397 206 . V/ 12C-Osw 0.091 a 5.28 1.89 192 147 776 278 0 0 0 0 -G 1D-c20v 0.570 a 33.06 59.07 24 0 793 1418 0 0 0 0 11 -D 1100 0.390 e 22.62 10.04 21 21 475 211 0 0 0 0 W[- 12�w 0.091 s 5.28 1.89 144 120 633 227 0 0 0 0 -G 1D-c2ov 0.570 s 33.06 30.49 24 0 793 732 0 0 0 0 V)f 12C Osw 0.091 s 5.28 1.89 128 128 676 242 0 0 0 0 I_--C, 1 D.c20v 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 V 12C-Osw 0.091 w 528 1.89 96 63 333 119 0 0 0 0 1 Dc2ov 0.570 w 33.06 59.07 12 0 397 709 00 0 0 1100 0.390 w 22.62 10.04 21 21 475 211 0 0 0 0 1260sw 0.091 w 5.28 1.89 96 84 443 159 96 84 443 159 1D-c20v 0.570 w 33.08 59.07 12 0 397 709 12 0 397 709 C 16A-30ad 0.032 0.00 0.00 0 0 0 0 0 0 0 0 C C part ceiling. 0.048 - 2.81 2.38 60 60 169 143 0 0 0 0 F 19A-19bscp 0.049 - 2.23 0.43 96 96 214 42 0 0 0 0 f 19A-19bstp 0.049 - 2.23 0.43 72 72 160 31 0 0 0 0 F 19A-19bswp 0.049 - 223 0.43 360 360 802 156 144 144 321 62 F 19A-19bswo 0.049 - 2.23 0.43 288 288 641 125 0 0 0 0 111 312 6 c)AED excursion I 10835I 7810� I 2001 I 1607I Envelope loss/gain 12 a) Infiltration 3336 338 690 70 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 6 1380 2 460 Appliances/Other 2100 0 Subtotal(lines 6 to 13) 14171 11628 2691 2137 Less external load 0 0 0 0 Less transfer 00 0 0 0 00 0 Redistribution 14 Subtotal 14171 11628 2691 2137 15 Duct loads 37% 42% 5307 4936 37% 42% 1008 907 Total room load (cfm) I I I 19478 16�I I I 36194951 3044 I I Air 1671 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. wf 2022-Jun-21 15:35:45 .------ ---� Right-Suite®Universa1202222.0.03 RSU22010 Page3 ...com\Documents\Wrightsoft HVAC\12 SALT WORKS.rup Cale=MJ8 Front Door faces: W wrlghtsolf Right-J® Worksheet Job: 12 SALT WORKS 1ST FLOOR ZONE Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name BATH KITCHEN 2 Exposed wall 6.0 ft 30.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 12.0 ft 18.0 x 12.0 ft 5 Room area 72.0 ft' 216.0 ft' i Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load I I I number (Btuh/ft'-*F ) (Btuh/ft') I or perimeter (ft) (Btuh) I or perimeter (ft) (Btuh) I I Heat I Cool I Gross I N/P/S Heat Cool Gross N/P/S Heat I Cool 6 W 12C-Osw 0.091 n 5.28 1.89 48 40 211 76 0 0 0 0 I-f 1D-c2ov 0.570 n 33.06 17.17 8 0 264 137 0 0 0 0 . W 12C-Osw 0.091 e 5.28 1.89 0 0 0 0 0 0 0 0 1D-c20v 0.570 e 33.06 59.07 0 0 0 0 0 0 0 0 11 11 D0 0.390 a 22.62 10.04 0 0 0 0 0 0 0 0 Vy 12C-Osw 0.091 s 5.28 1.89 0 0 0 0 144 120 633 227 I--C 1D-c2ov 0.570 s 33.06 30.49 0 0 0 0 24 0 793 732 12C-0sw 0.091 s 5.28 1.89 0 0 0 0 0 0 0 0 1 Dc2ov 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 W 12C-0sw 0.091 w 5.28 1.89 0 0 0 0 96 63 333 119 )---G 1D-c20v 0.570 w 33.06 59.07 0 0 0 0 12 0 397 709 rr DD 1100 0.390 w 22.62 10.04 0 0 0 0 21 21 475 211 W 12C-0sw 0.091 w 5.28 1.89 0 0 0 0 0 0 0 0 V--G 1 D-c2ov 0.570 w 33.06 59.07 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 C C part ceiling. 0.048 - 2.81 2.38 0 0 0 0 60 60 169 143 F 19A-19bscp 0.049 - 2.23 0.43 0 0 0 0 0 0 0 0 F 19A-19bstp 0.049 - 2.23 0.43 72 72 160 31 0 0 0 0 F 19A-19bswp 0.049 - 2.23 0.43 0 0 0 0 216 216 481 94 F 19A 19bswo 0.049 - 2.23 0.43 0 0 0 0 0 0 0 0 1 6 Envelope loss/gain 636 280 32811 2843 12 a) Infiltration 173 17 863 87 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 1200 Subtotal(lines 6 to 13) 809 297 4143 4131 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 809 297 4143 4131 15 Duct loads 37% 42% 303 126 37% 42% 1552 1753 695 84 II 1 Air required I 111 441 424 24I I I 5223I 53231 Total room load(cfm) I Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. w - 2022-Jun-21 15:35:45 s♦! •_�- ---r-�--�-- -� Right-Suite®Universa1202222.0.03 RSU22010 Pagel •K• ...com\Documents\Wrightsoft HVAC\12 SALT WORKS.rup Calc=MJ8 Front Door faces: W • " "wRights*f- Right-J® Worksheet Job: 12 SALT WORKS 1ST FLOOR ZONE Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name LIVING HALL/STAIRS 2 Exposed wall 34.0 ft 22.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 16.0 x 18.0 ft 16.0 x 6.0 ft 5 Room area 288.0 ft. 96.0 ft. Ty Construction r U-value Or I HTM I Area (ft.) Load I Area (ft') Load number (Btuh/ft-°F (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) IHeat I Cool I Gross I N/P/S Heat I Cool I Gross N/P/S Heat I Cool 6 Vr12C•0sw 0.091 n 5.28 1.89 128 104 549 196 0 0 0 0 L-C 1 Dc2ov 0.570 n 33.06 17.17 24 0 793 412 0 0 0 0 12C-Osw 0.091 e 5.28 1.89 144 120 633 227 48 27 143 51 1D-c20v 0.570 e 33.06 59.07 24 0 793 1418 0 0 0 0 1.1 11 11 D0 0.390 e 22.62 10.04 0 0 0 0 21 21 475 211 W 12C-0sw 0.091 s 5.28 1.89 0 0 0 0 0 0 0 0 I._.-G 1 D-c2ov 0.570 s 33.06 30.49 0 0 0 0 0 0 0 0 1/W 12C-0sw 0.091 s 5.28 1.89 0 0 0 0 128 128 676 242 l-(; 1D-c2ov 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 1/6 12C-Osw 0.091 w 5.28 1.89 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 33.06 59.07 0 0 0 0 0 0 0 0 1100 0.390 w 22.62 10.04 0 0 0 0 0 0 0 0 Vv 12C-Osw 0.091 w 5.28 1.89 0 0 0 0 0 0 0 0 L-C 1D-c2ov 0.570 w 33.06 59.07 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 0.00 0.00 0 0 0 0 0 0 0 0 C C part ceiling. 0.048 - 2.81 2.38 0 0 0 0 0 0 0 0 F 19A-19bscp 0.049 - 2.23 0.43 0 D 0 0 96 96 214 42 F 19A-19bstp 0.049 2.23 0.43 0 0 0 0 0 0 0 0 F 19A-19bswp 0.049 - 2.23 0.43 0 0 0 0 0 0 0 0 F 19A-19bswn 0.049 - 2.23 0.43 288 288 641 125 0 0 0 0 6 I c)AED excursion 204 I -47 Envelope loss/gain 3411 2582 i` 1507 498 12 a) Infiltration 978 99 633 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 4 920 0 0 Appliances/other 900 0 Subtotal(lines 6 to 13) 4388 4501 2140 562 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4388 4501 2140 562 15 Duct loads 37% 42% 1643 1911 37% 42% 801 239 Total required room load(cfm) I I I 6032 237I 6415 1 I 29411 800 Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. .",' w - 2022-Jun-2115:35:45 Aft -- Right-Suite®U niversal 2022 22.0.03 RSU22010 Page 5 ...com\DocumentstWrightsoft HVAC112 SALT WORKS.rup Caic=MJ8 Front Door faces: W *wrightsoft Right-J® Worksheet Job: 12 SALT WORKS 2ND FLOOR ZONE Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name 2ND FLOOR ZONE BEDROOM 2 2 Exposed wall 116.0 ft 43.0 ft 3 Room height 8.0 ft 8.0 ft heat/cool 4 Room dimensions 12.0 x 19.0 ft 5 Room area 756.0 ft' 228.0 ft' I Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load r number (Btuh/ft'-°F I (Btuh/ft') ( or perimeter (ft) I (Btuh) I or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S I Heat I Cool I Gross I NIP/S Heat I Cool 6 It12C-0sw 0.091 n 5.28 1.89 272 240 1267 453 96 84 443 159 L-f 1D-c2ov 0.570 n 33.06 17.17 32 0 1058 549 12 0 397 206 . V)/ 12C-Osw 0.091 a 5.28 1.89 192 168 887 317 0 0 0 0 1 �� 1D-c2ov 0.570 e 33.06 59.07 24 0 793 1418 0 0 0 0 1.1 11 D0 0.390 e 0.00 0.00 0 0 0 0 0 0 0 0 Vy 12C-Osw 0.091 s 0.00 0.00 0 0 0 0 0 0 0 0 L--G 4 D-c2ov 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 Val 12C-03w 0.091 s 5.28 1.89 272 260 1372 491 96 96 507 181 -G 1 Dc2ov 0.570 s 33.06 30.49 12 0 397 366 0 0 0 0 12C-0sw 0.091 w 0.00 0.00 0 0 0 0 0 D 0 0 1D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1100 0.390 w 0.00 0.00 0 0 0 0 0 0 0 0 V(r 12GOsw 0.091 w 5.28 1.89 192 180 950 340 152 140 739 264 L___r 1D c2ov 0.570 w 33.06 59.07 12 0 397 709 12 0 397 709 C 16A-30ad 0.032 - 1.86 2.22 528 528 980 1170 0 0 0 0 C C part ceiling. 0.048 - 2.81 2.38 228 228 640 544 228 228 640 544 F 19A 19bscp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 f 19A-19bstp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-19bswp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-19bswo 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 481 105 Envelope loss/gain 8741 6838� 3123 2168 12 a) Infiltration 3336 338 1237 125 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 4 920 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 12077 8096 4359 2753 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 12077 8096 4359 2753 15 Duct loads 37% 42% 4523 3437 37% 42% 1633 1169 I TotalAirrequired room loa ( ) d I I !I 16B501 1165321 I 5235 3215I cfml Calculations aooroved by ACCA to meet all reauirements of Manual J 8th Ed. -4- w R- 2022-Jun-21 15:35:45 Right-Suite®U niversal 2022 22.0.03 RSU22010 Page 6 ...comlDocuments1Wrightsoft HVAC\12 SALT WORKS.rup Cale=MJ8 Front Door faces: W *wrIghtsoftC Right-J® Worksheet Job: 12 SALT WORKS 2ND FLOOR ZONE Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name BATH 2 BEDROOM 3 2 Exposed wall 6.0 ft 34.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 6.0 x 12.0 ft 16.0 x 18.0 ft 5 Room area 72.0 ft2 288.0 ft2 I I Ty Construction U-value Or HTM Area (ft2) Load Area (ft') Load number 1(Btuh/ft2-°F I (Btuh/ft2) I or perimeter (ft) ( (Btuh) I or perimeter (ft) (Btuh) I Heat I Cool I Gross ! N/P/S Heat I Cool I 1 Gross I N/P/S I Heat Cool 6 12C-Osw 0.091 n 5.28 1.89 48 40 211 76 128 116 612 219 . 1D-c2ov 0.570 n 33.06 17.17 8 0 264 137 12 0 397 206 . 12C-05w 0.091 e 5.28 1.89 0 0 0 0 144 120 633 227 1 D-c2ov 0.570 e 33.06 59.07 0 0 0 0 24 0 793 1418 11 11 D0 0.390 e 0.00 0.00 0 0 0 0 0 0 0 0 Vy 12C-0sw 0.091 s 0.00 0.00 0 0 0 0 0 0 0 0 I-G 1D-c2ov 0.570 s 0.00 0.00 0 0 0 0 0 0 0 0 W 12C-Osw 0.091 a 5.28 1.89 0 0 0 0 0 0 0 0 L---G 1D-c2ov 0.570 s 33.06 30.49 0 0 0 0 0 0 0 0 V. 12C-0sw 0.091 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-c2ov 0.570 w 0.00 0.00 0 0 0 0 0 0 0 0 1100 0.390 w 0.00 0.00 0 0 0 0 0 0 0 0 V�/ 12C-Osw 0.091 w 5.28 1.89 0 0 0 0 0 0 0 0 L-G 1 D-c2ov 0.570 w 33.06 59.07 0 0 0 0 0 0 0 0 C 16A-30ad 0.032 - 1.86 2.22 72 72 134 160 288 288 535 638 C C part ceiling. 0.048 2.81 2.38 0 0 0 0 0 0 0 0 F 19A-19bscp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-19bstp 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-19bswp 0,049 - 0.00 0.00 0 0 0 0 0 0 0 0 F 19A-19bswo 0.049 - 0.00 0.00 0 0 0 0 0 0 0 0 on 61 Envelope loss/l 5 102 gain 609 378 2970 2809 12 a) Infiltration 173 17 978 99 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 2 460 Appliances/other 0 0 Subtotal(lines 6 to 13) 782 395 3948 3368 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 782 395 3948 3368 15 Duct loads 37% 42% 293 168 37% 42% 1479 1430 TAiortalrequired room load(cfm) I I ( 1075 42I 563 31 I ( 5223I 4263798 I Calculations aoaroved by ACCA to meet all requirements of Manual J 8th Ed. wr*t wft" 2022-Jun-21 15:35:45 Right-Suite®Universal 2022 22.0.03 RSU22010 Page 7 ...comtDocuments\Wrightsoft HVAC112 SALT WORKS.rup Cat=MJ8 Front Door faces: W wri®htsolt- Right-J® Worksheet Job: 12 SALT WORKS 2ND FLOOR ZONE Date: Jun 21,2022 By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA 1 Room name HALL 2ND 2 Exposed wall 33.0 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 1.0 x 168.0 ft 5 Room area 168.0 ft' I I I Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuh/ft'-°F I (Btuh/ft') ( or perimeter (ft) (Btuh) I or perimeter II I Heat I Cool Gross I N/P/S Heat Cool I Gross I N/P/S 1 Heat I Cool 6 W 12C-Osw 0.091 n 5.28 1.89 0 0 01 0 I--G 1 D-c2ov 0.570 n 33.06 17.17 0 0 0 0 W 12C-0sw 0.091 a 5.28 1.89 48 48 253 91 1D-c2ov 0.570 e 33.06 59.07 0 0 0 0 11 11D0 0.390 e 0.00 0.00 0 0 0 0 vy 12C-0sw 0.091 s 0.00 0.00 0 0 0 0 I--G 1D-c2ov 0.570 s 0.00 0.00 0 0 0 0 W 12C-0sw 0.091 s 5.28 1.89 176 164 866 310 L_-{ 1 Dc2ov 0.570 s 33.06 30.49 12 0 397 366 12C-Osw 0.091 w 0.00 0.00 0 0 0 0 1D-c2ov 0.570 w 0.00 0.00 0 0 0 0 D 11 D0 0.390 w 0.00 0.00 0 0 0 0 Vy- 12C 0sw 0.091 w 5.28 1.89 40 40 211 76 1C 1 D c2ov 0.570 w 33.06 59.07 0 0 0 0 C 16A-30ad 0.032 - 1.86 2.22 168 168 312 372 C C part ceiling. 0.048 2.81 2.38 0 0 0 0 F 19A-l9bscp 0.049 - 0.00 0.00 0 0 0 0 F 19A-19bstp 0.049 - 0.00 0.00 0 0 0 0 F 19A-19bswp 0.049 - 0.00 0.00 0 0 0 0 F 19A 19bswo 0.049 - 0.00 0.00 0 0 0 0 6 c)AED excursion 2039 12691 I Envelope loss/gain 3 12 a) Infiltration 949 96 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 2988 1579 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2988 1579 15 Duct loads 37% 42% 1119 670 I Total required room load (cfm) I I I 41071 161 22501 123 I I I Air Calculations approved by ACCA to meet all reauirements of Manual J 8th Ed. 2022-Jun-21 15:35:45 AeN% Right-Suite®Universa1202222.0.03 RSU22010 Page8 corn\DocumentstWrightsoft HVAC\12 SALT WORKS.rup Calc=MJ8 Front Door faces: W /t \ SECOND FLOOR t---� ► 1 fa 118 cfm EL 11 ; cfm 42 cf 132 cfm 132 clm BA H BEDROOM BEDROOM I0- .i. • p 386 277 c m HALL 2NE 16 cfm Job#: 12 SALT WORKS JIM GRIFFITS Scale: 1 :62 Performed for: Page 1 TOM GREW 29 CAPTAIN DUNBAR Rigirt Sutee UrwersaI2022 12 SALT WORKS LN BREWSTER,MA 22.0.03 RSU22010 SOUTH YARMOUTH,MA 2022-Jun-21 15:40:35 ...rightsoft HVAC112 SALT WORKS.ru FIRST FLOOR T I 11 167 cfm 4 cfm 176 cfm 176 m B 1 El 234 m LIVING 1'1. — --14 1" 36• cfm _.-t I PGA:* -323 cfm KITCHEN 111 HALL / STAIR`. 161 cfm i 1161 cfm 115 cfm Job#: 12 SALT WORKS JIM GRIFFITS Scale: 1 :62 Performed for: Page 2 TOM GREW 29 CAPTAIN DUNBAR Right-Suite®U niversal 2022 12 SALT WORKS LN BREWSTER,MA 22.0.03 RSU22010 SOUTH YARMOUTH,MA 2022-Jun-21 15:40:35 ...rightsoft HVAC\12 SALT WORKS.rL . . wrightsoft. Duct System Summary Job: 12 SALT WORKS Date: Jun 21,2022 Entire House By: JIM GRIFFITS 29 CAPTAIN DUNBAR,BREWSTER,MA Project Information For: TOM GREW 12 SALT WORKS LN, SOUTH YARMOUTH, MA Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 1416 cfm 1416 cfm Total effective length (TEL) 553 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk BATH h 424 44 23 0 0 Ox 0 VIFx 0 0 BATH 2 h 563 42 31 0 0 Ox 0 VIFx 26.0 95.0 st6 BED 1 c 3044 145 167 0 0 Ox 0 VIFx 17.0 205.0 st2 BEDROOM 2 h 1961 118 107 0 0 Ox 0 VIFx 0 0 BEDROOM 2-A h 1961 118 107 0 0 Ox 0 VIFx 0 0 BEDROOM 3 c 2399 106 132 0 0 Ox 0 VIFx 29.0 230.0 st1 BEDROOM 3-A c 2399 106 132 0 0 Ox 0 VIFx 42.0 95.0 st5 HALL/STAIRS h 800 115 44 0 0 Ox 0 VIFx 40.0 105.0 st2 HALL 2ND h 2250 161 123 0 0 Ox 0 VIFx 37.0 275.0 st1 KITCHEN c 2942 112 161 0 0 Ox0 VIFx 11.0 205.0 st2 KITCHEN-A c 2942 112 161 0 0 Ox 0 VIFx 20.0 195.0 st2 LIVING c 3206 118 176 0 0 Ox 0 VIFx 33.0 180.0 st2 LIVING-A c 3206 118 176 0 0 Ox 0 VIFx 0 0 Supply Trunk Detail Table Trunk Htg CIg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 268 255 0 0 0 8 x 0 ShtMetl st2 Peak AVF 751 871 0 0 0 8 x 0 ShtMetl st6 Peak AVF 42 31 0 0 0 0 x 0 VinIFIx st2 st5 Peak AVF 106 132 0 0 0 0 x 0 VinIFIx st2 je, „ 2022-Jun-21 15:35:46 ai T� Rig ht-Suite®Universa12022 22.0.03 RSU22010 Page 1 ...com\Documents\Wrghtsoft HVAC112 SALT WORKS.mp Calc=MJ8 Front Door faces: W Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb5 Ox 0 374 386 227.0 0 0 0 Ox 0 VIFx rt1 rb4 Ox 0 277 246 93.0 0 0 0 Ox 0 VIFx rt1 rb3 Ox 0 234 220 241.0 0 0 0 Ox 0 VIFx rt3 rb2 Ox 0 223 323 168.0 0 0 0 Ox 0 VIFx rt3 rb1 Ox 0 307 366 99.0 0 0 0 Ox 0 VIFx rt3 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 651 632 0 0 0 8 x 0 MetIFIx rt3 Peak AVF 764 908 0 0 0 8 x 0 ShtMetl r12 rt2 Peak AVF 764 908 0 0 0 8 x 0 ShtMetl yv 2022-Jun-21 15:35:46 4 RightSuite®Universal 2022 22.0.03 RSU22010 Page 2 ...com1Documents1Wrightsoft HVAC\12 SALT WORKS.rup Calc=MJ8 Front Door faces: W