SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot '"/c;//6;r7 Zone of Contribution: In Out Acreage
Street:
Commercial: Residential:_ __
Village:
Floor Plan: # Bedrooms:
Owner: Installer:
Address: Phone:
Phone:
Builder: Engineer:
Address: Phone:
Phone:
N/A YES NO
1. Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table - -
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: -
5. Water line 10 ft from septic components Var.: -
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: i 9. Leaching minimum 100 ft from wetlands
Var.:
10. Leaching
minimum 150 ft from drinking well/25 ft irrigation well Var.:
1 1. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: I
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", 'A"preferred
18. S stem meets breakout requirements
19. Specified tee sizes are proper, gas baffle on outlet tee PVC liner: Wall:
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal
22. System adequately sized for its intended use
23:Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6" of grade, pump chamber cover to grade
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber
31. Engineer to inspect and certify soils: wall: , commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
1 r 33.H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature , i
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow:
37. Check area lots for groundwater/Label groundwater in Assessor's Map gpd
Plan reviewed by: