HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Zone of Contribution: In Out_ Acreage
Commercial: Residential:_______Street: r+j • //yc; i j Cr9„,..Q I / 1cj
Village:
Floor Plan: # Bedrooms:4
Owner: -r),„mr15, 64.4rvv;y` Installer: ( 44. LZ,c: sir )rill
Address: i-y �, f
Phone: l 5'�►S ��Za,-�.�� .�.cl Phone: �,;�, � 7S- ���
f }�i- dL - n377 .
Builder: Engineer: , •
Address: " u k s
Phone: Phone: S Z, _ �/ 7 S3 r
NIA YES NO
1. Re.uired#of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table - - -
4. Foundation 2 ft above high .oint of road .7 _-.
5. Water line 10 ft from septic components Var.: Fnd: Var.: -
6. Benchmark indicated and shown-NGVD if near wetlands -
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands
ar.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.:
1 12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.:
14. Leaching set 4-5 ft above ad.. water or bottom of test hole Var.: I
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements- min. 1/8", %"preferred
_18. System meets breakout requirements PVC liner: Wall: I
v 19. S.ecified tee sizes are .ro.er, as baffle on outlet tee
20. Sewage is under 10,000 ..d for .arcel _
21. No oarbaoe dis.osal 22. System ade uately sized for its intended use
23:Minimum 6"stone or com.acted below tank and dboxNMI
24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Ins.ection sort on .lastic chambers/leach field _1111111.11111111
26. Electrical •errnit for sums chamber/Se.arate meter for duplexes _IMO-
27. Rum. system-2"line,wee• hole,check valve, tee in dbox, sump size
28. Se.tic tank/sums chamber to be factory wate 'roofed
_�_
29. Vent .rovided if leachin below 3 feet,under driveway/parkingMil
_
30. Buo anc calculations for tank/sum. chamber
31. Engineer to ins.ect and certify soils: wall: commercial:32. Engineer/Re_istered Sanitarian and Land Surveyor stam.s/signature
33.H-20 loading is sub.ect to vehicular traffic, : oundwater11.11111111.1111111111
_--
34.Title V Ap.lication and s errnit fee, installer si• s ature
35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction re•uired max.
37. Check area lots for groundwater/Label • oundwater er Asse,ors Ma. d -
•
Plan reviewed by:
- - co:o,