Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLDF-23-1 BLD A
JUN 12 2023 wi BIJI '{ ' — ' 3 y _ . 141:Ci ��(°''��� x 1 `' ` iya 11 46 28, 5044 Pcpurtatuth gleft1 ' APPLICATION F R FIRE PROTECTION PERMIT Date 6/ 8 I .__ _ _ PER 11 NUMBER_ B LbF 2 3—. Projected Start Date:__7/3 J 3__ ___Date of issue In accordance with the provisions of 8 t_;i','IR and M.G.L. Chapter 148, as provided in Section This application is hereby made by_1+0 E is...crn,c......_wGl c . W, (Da.., ;ctsase' (Full name ofperson,Firm or Corporation) Address 46 ELK Ron DR fl 4L 6o re ._.BA 0a3Sf (Contact#) '-)$1 8S8 917o _Email ,f cc.,cl1).z.l ig_crr;C ce Ve e t c,,. em-r Owner of property 6 n c . D a Lto - Cu ZritS r I c Job Location_.?I. E'451. 3'_Sail ;^'q _ (Street&City,or Town) '" For permission;to(state clearly purpose for which permit is requested) .1.r1 772II an 02 _sz _.....,.a._.t sue_-.a._a Larw, _s YSTe_ ;n, a 3O Fr, __Ash). C or%5-rrv_cri ►Z _ ..0p....?-..c,rigL..._3....,a_x. -77 ,4t.5$4.7a-) Su;lcS;nt99 J Name of competent operatat (if applicable)._ r)an_ " a. D;G .5a_re �• Cert.oriceseNo,.� a�., �__. 6 =: �, o, t��v 1 �o0 i � By � . - _ __-- q'Stgn�.ature r a.4ppliaant Building Official: Date: C3'K'A) e FED $50.00 LAC 66 Elk Run Middleboro, MA 02346 Office: 508-697-8185 Cell: 781-858-9170 Fire Alarm System Narrative June 8, 2023 The fire alarm system for 24 Easy Street, Yarmouth, MA Building A (a 3-bay tradesman building) will be a new construction installation. The building is under 7,500 square feet and does not require a sprinkler system. Upon activation of an alarm, the fire alarm control panel (located at Building B) will automatically call an NFPA-approved central station (using a cellular dialer) who will report a fire to Yarmouth Fire Department. The fire alarm is initiated by the following: 1 pull station 2 heat detector 3 carbon monoxide detector Building occupants will be notified by siren and strobe. Sincerely, Daniel E. DiCesare D&D Electric, LLC MA Lic 21275A DF-60957:D ES-200X Series re) Fire-LITGALarms Intelligent Addressable Fire Alarm Control Panels by Honeywell Addie' ' 'abI^!�\? a m cont anel° ` General The ES-200X, ES-200XC, ES-200XI, and ES-200XP are the latest intelligent addressable Fire Alarm Control Panel (FACP)from Fire•Lite Alarms and is a direct replacement for the MS-92000DLS. The ES- g 200X support up to 198 addressable devices (99 detectors and 99 modules). With an extensive list of powerful features, the ES-200X Series programs just like Fire•Lite's other addressable products, yet fits into applications previously served only by conventional panels. The ES-200X and ES-200XC feature a pre-installed IPOTS-COM, a �x ? dual technology (POTS and IP) communicator. The POTS transmits system status(alarms,troubles, AC loss,etc.)to a Central Station via � ' j the public switched telephone network. The IP communicator's inter- net monitoring capability sends alarm signals over the Internet saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line. Optional cellular reporting is available using an HW-TG7F Series Communicators or the CLSS Pathway. ` The ES-200XP features an integrated CLSS Pathway Pro Communi 0, ' cator, a dual-SIM (AT&T! Verizon) 5G LTE-M Communicator with optional IP connection.The CLSS Pathway Pro transmits system sta- tus (alarms, troubles, AC loss, etc.) to the Central Station using LTE CAT-M1 networks,serving as a bridge between the fire system and the CLSS Cloud. The IP communicator's Internet monitoring capability ▪ Selectable strobe synchronization for System Sensor, Wheelock, sends alarm signals over the Internet, meeting requirements for and Gentex devices backup communication. As an integrated communicator, the CLSS • Notification Appliance Circuit End of Line resistor matching Pathway Pro,typically,can transmit data faster than dial capture meth- Four programmable function keys for ease of maintenance ods. •• Two programmable relays and one fixed trouble relay Remote and local programming of the control panel is possible using • Built-in Programmer the FS-Tools Upload/Download utility.Programming databases can be • Integral 80-character LCD display with backlighting uploaded/downloaded via the panel's USB port(and USB cable)or via • Real-time clock/calendar with automatic daylight savings control an ethernet connection using the IPOTS-COM communicator • History file with 1,000 event capacity (ES-200X and EX-200XC only). The USB port also allows for the • Addressable sounder base compatibility download or upload of the entire program, history file, walk-test data, • Multi-criteria detector (smoke, heat, CO) with programmable current status and system voltages by means of a USB flash drive. response The power supply and all electronics are contained on a circuit board ▪ Control module delay timer supported on a new quick install chassis and housed in a metal cabi- • Automatic detector sensitivity testing(NFPA 72 compliant) net. Available accessories include local and remote upload/download • Automatic device type-code verification software, remote annunciators, and reverse polarity/city box transmit- • Point trouble identification ter(4XTMF). • Waterflow selection per module point • Alarm verification selection per detector point Features • Maintenance alert warns when smoke detector dust accumulation is excessive • Listed to UL Standard 864, 10th edition • One-person audible or silent walktest with walktest log and printout • Pre-installed IPOTS-COM Ethernet IP and POTS (Plain Old Tele- • System alarm verification selection per detector point phone Service) Central Station Communicator (ES-200X and • PAS(Positive Alarm Sequence)and Pre-signal per point(NFPA 72 EX-200XC only) compliant) • Optional Cellular Central Station Communicators over AlarmNet® • Up to 16 ANN-BUS annunciators-8 per each ANN-Bus (ES-200X and EX-200XC only) • Remote Acknowledge,Alarm Silence, Reset and Drill via address- • Integrated CLSS Pathway Pro Communicator;dual SIM AT&TNeri- able modules or remote annunciator zon networks with LTE-CAT-M1 5G technology(EX-200XP only) • Upload/Download of program and data via USB with optional • Cloud monitoring using Honeywell's Connected Life Safety Ser- FS-Tools Programming Utility vices(CLSS)Cloud solutions software(EX-200XP only) SLC(DCL) COMMUNICATION LOOP • Automated activation of the ECC-50/100 Emergency Command • Supports LiteSpeediM and CLIP protocols Center • SLC (DCL)operates up to 10,000 ft. (3,000 m) in LiteSpeed mode • ECC-FFT Firefighter Telephone option with twisted, unshielded wire • Compatible with SWIFT®wireless devices • Auto-programming (learn mode) reduces installation time. Reports • Single addressable SLC (DCL) loop which meets NFPA Class B two devices set to the same address and Class A requirements • Four built-in, independently programmable, Class A or Class B • 198 addressable device capacity(99 addressable detectors and 99 NAC circuits modules) DF-60957:D-3/27/2023—Page 1 of 4 • Compatible with Fire•Lite's addressable devices (refer to the SLC HW-TG7FE-A/HW-TG7FE-V: CLSS-Enabled 5G/LTE-M Dual Path Wiring Manual) Commercial Fire Alarm Communicators for AT&T and Verizon NOTIFICATION APPLIANCE CIRCUITS(NACS) HW-TG7FP-A/HW-TG7FP-A: CLSS-Enabled 5G/LTE-M Sole Path Commercial Fire Alarm Communicators for AT&T and Verizon • Four independently programmable output circuits. Circuits can be DP-ES-R:Optional dress panel for the. configured for Class A or Class B wiring TR-CE:Optional trim ring for semi-flush mounting. • Silence Inhibit and Autosilence timer options BB-2F:Optional cabinet for one or two modules. • Continuous,March Time,Temporal,or California code for main cir BB-6F: Optional cabinet for up to six modules mounted on CHS-6 cult board NACs with two-stage capability chassis. • Selectable strobe synchronization per NAC BB-26: Battery backbox, holds up to two 25 AH batteries and CHG- • 2.5 A special application,250mA regulated,total power for NACs 75 NOTE:Maximum or total 24VDC system power shared between all NAC BB-55F: Battery box, houses two 55 AH batteries circuits and the ANN-BUS is 2.7 A CHS-6:Chassis, mounts up to six multi-modules in a BB-6F cabinet. PROGRAMMING AND SOFTWARE CHG-75: Battery charger for lead-acid batteries with a rating of 25 to • Autoprogramming(learn mode)reduces installation time 75 AH. • Custom English labels (per point) may be manually entered or CHG-120F: Remote battery charging system for lead-acid batteries selected from an internal library file with a rating of 55 to 120 AH. Requires additional BB-55F for mount- • Two programmable Form-C relay outputs rig. 99 software zones NOTE:CHG-120F or CHG-75 required for batteries larger than 18AH. •• Continuous fire protection during online programming BAT Series: Batteries.see data sheet DF-52397. • Program Check automatically catches common errors not linked to PRN Series: UL listed compatible event printer. Uses tractor-fed any zone or input point paper. • OFFLINE PROGRAMMING: Create the entire program in your OPTIONAL MODULES office using FS-Tools, a Windows®-based software package, and upload/download system programming locally.Offline programming 4XTMF Reverse Polarity Transmitter Module: Provides a super- requires an ethernet connection. FS-Tools is available on vised output for local energy municipal box transmitter,alarm and trou- www.firelite.com. ble. Includes a disable switch and disable trouble LED. PWRMOD24 Power Expander Module: Optional power module. User interface Increases alarm power output to 6 amps. LED INDICATORS COMPATIBLE ANNUNCIATORS • Fire Alarm(red) • CO Alarm (yellow) ANN-80: Remote LCD annunciator mimics the information displayed • AC Power(green) Supervisory(yellow) on the FACP LCD display. Recommended wire type is un-shielded. • Trouble(yellow) • Ground fault(yellow) ANN-100: Remote LCD annunciator mimics the information displayed • Battery fault(yellow) Disabled (yellow) on the FACP LCD display. Recommended wire type is un-shielded. • Maintenance(yellow) • Communication(yellow) For use in FM applications only. • Alarm Silenced(yellow) F1-F4 Programmable Function ANN-I/O: LED Driver Module provides connections to a user supplied Keys(yellow) graphic annunciator. (See DF-52430.) ANN-LED: Annunciator Module provides three LEDs for each zone: KEYPAD Alarm, Trouble, and Supervisory. Ships with red enclosure. (See OF- • 16 key alpha-numeric pad • Acknowledge 60241.) • Alarm Silence • Drill (Manual Evacuate) ANN-RLED: Provides alarm (red) indicators for up to 30 input zones • Four(4)programmable function keys • Reset(lamp test) or addressable points. (See DF-60241.) ANN-RLY: Relay Module provides 10 programmable Form-C relays. PRODUCT LINE INFORMATION Can be mounted inside the cabinet. (See DF-52431.) ES-200X: Addressable Fire Alarm Control Panel with one SLC loop. ANN-S/PG: Serial/Parallel Printer Gateway module provides a con- Includes main circuit board with display, pre-installed communicator, nection for a serial or parallel printer. (See DF-52429.) chassis with transformer, backbox with door, plastic bag containing ADDRESSABLE DEVICES screws,cables, key,etc. ES-200XC:Addressable Fire Alarm Control Panel with one DCL loop. All feature a polling LED and rotary switches for addressing. Includes main circuit board with display, pre-installed IPOTS-COM SD365(A):Addressable low-profile photoelectric smoke detector. Lite- communicator, chassis with transformer, dress panel, backbox with Speed only. door,plastic bag containing screws,cables, key,etc. SD365(A)-IV: Addressable low-profile photoelectric smoke detector. ES-200X1: Addressable Fire Alarm Control Panel with one SLC loop. Ivory. LiteSpeed and CLIP mode. Includes main circuit board with display, chassis with transformer, SD365T(A): Addressable low-profile photoelectric smoke detector dress panel,backbox with door,plastic bag containing screws,cables, with thermal sensor. LiteSpeed only. key,etc. SD365T(A)-IV: Addressable low-profile photoelectric smoke detector ES-200XP:Addressable Fire Alarm Control Panel with one SLC loop. with thermal sensor. Ivory. LiteSpeed and CLIP mode. InclPathway Pro udes main ccommunicator,ithchassisoard wwthith dtransformer,isplay, ldrelsespanelCLSs, backbox SD365R(A): Remote test capable addressable photoelectric smoke with door,plastic bag containing screws,cables, key,etc. detector for use with DNR(W)duct detector housing. LiteSpeed only. FS-Tools: Programming software for Windows®-based PC computer. SD365R(A)-IV: Remote test capable addressable photoelectric smoke Available for download at www.firelite.com. detector for use with DNR(W)duct detector housing. Ivory. LiteSpeed IPOTS-COM: Dual technology (POTS and IP) communicator. and CLIP mode. (replacement board) (ES-200X and EX-200XC only) SD365CO: Addressable, low-profile device that provides fire, heat, HW-AV-LTE-M:Optional CLSS Pathway and carbon monoxide(CO)detection,LiteSpeed only. HW-TG7FS-A/HW-TG7FS-V: CLSS-Enabled 5G/LTE-M Commercial SD365CO-IV: Addressable,low-profile device that provides fire, heat, Fire Alarm Communicators for AT&T®and Verizon® and carbon monoxide (CO) detection. Ivory. LiteSpeed and CLIP mode. Page 2 of 4—DF-60957:D•3/27/2023 H365(A): Low-profile 135°F fixed thermal sensor. LiteSpeed only. BG-12LX: Addressable manual pull station with interface module H365(A)-IV: Low-profile 135°F fixed thermal sensor. Ivory. LiteSpeed mounted inside. and CLIP mode. I300(A): This module isolates the SLC loop from short circuit condi- H365R(A): Low-profile, intelligent, rate-of-rise thermal sensor. Lite- tions(required for Class A or Class X operation). Speed only. ISO-6(A): Six-fault isolator module. Mount one or two modules in a H365R(A)-IV: Low-profile, intelligent, rate-of-rise thermal sensor. BB-2F cabinet(optional). Mount up to six modules on a CHS-6 chas- Ivory. LiteSpeed and CLIP mode. sis in a BB-6F cabinet. H365HT(A): Low-profile intelligent 190°F/88°C fixed thermal sensor. SMB500: Used to mount all modules except the MMF-301(A) and LiteSpeed only. M301(A). H365HT(A)-IV: Low profile intelligent 190°F/88°C fixed thermal sen- MMF-300-10(A): Ten-input monitor module. Mount one or two mod- sor. Ivory. LiteSpeed and CLIP mode. ules in a BB-2F cabinet(optional). Mount up to six modules on a CHS- 6 chassis in a BB-6F cabinet. D365PL:Low-flow non-relay duct-detector housing;includes SD365R. MMF-302-6(A):Six-zone interface module.Mount one or two modules Legacy Devices in a BB-2F cabinet (optional). Mount up to six modules on a CHS-6 CP355(A):Addressable low-profile ionization smoke detector. chassis in a BB-6F cabinet. SD355(A):Addressable low-profile photoelectric smoke detector. CMF-300-6(A): Six-circuit supervised control module. Mount one or SD355T(A): Addressable low-profile photoelectric smoke detector two modules in a BB-2F cabinet (optional). Mount up to six modules with thermal sensor. on a CHS-6 chassis in a BB-6F cabinet. SD355R(A): Remote test capable addressable photoelectric smoke CRF-300-6(A): Six-relay control module (Form-C relays). Mount one detector for use with DNR(W)duct detector housing. or two modules in a BB-2F cabinet(optional).Mount up to six modules SD355C0: Addressable, low-profile device that provides fire, heat, on a CHS-6 chassis in a BB-6F cabinet. and carbon monoxide(CO)detection. SWIFT Wireless Devices H355(A): Fast-response,low-profile heat detector. W-GATE(A):LiteSpeed Wireless Gateway W-SD355(A): LiteSpeed intelligent,wireless photo detector. H355R(A): Fast-response, low-profile heat detector with rate-of-rise W-H355R(A):A : LiteSpeed intelligent wireless rate of rise (135°) heat option. ( ) p 9 detector. H355HT(A): Fast-response, low-profile heat detector that activates at W-SD355T(A):intelligent wireless photo/heat detector. 190°F/88°C. AD355(A): Low-profile, intelligent, "Adapt' multi sensor detector W-H355(A): LiteSpeed intelligent wireless fixed-temperature (135°) (B350LP base included). heat detector. B200S(A)(-WH)(-IV): Programmable,addressable sounder base. W-MMF(A):LiteSpeed Intelligent wireless monitor module. W-CRF(A):LiteSpeed Intelligent wireless relay module. B200SR(A)(-WH)(-IV):Addressable sounder base. W-BG12LX(A): LiteSpeed Intelligent wireless pull station. B200S-LF(-WH)(-IV):Programmable,addressable sounder base,low WAV-RL, WAV-WL,WAV-CRL,WAV-CWL: LiteSpeed Intelligent AV frequency. bases. B200SR-LF(-WH)(-IV):Addressable sounder base,low-frequency. W-USB: Wireless USB radio/antenna dongle that plugs into the USB BEAM355: Intelligent beam smoke detector. port of a PC running SWIFT Tools. BEAM355S: Intelligent beam smoke detector with integral sensitivity SWIFT Tools: Programming and diagnostic utility for the Wireless test. Gateway and devices.Available for download from firelite.com. D355PL(A): InnovairFlex low-flow non-relay duct-detector housing; NOTE:For more information on Compatible Addressable Devices for use includes SD355R. with the ES-200X, see the following data sheets (document numbers): DNR(A): InnovairFlex low-flow non-relay duct detector housing. SD365 Series (DF-61010), H365 Series (DF-61011),AD355 (DF-52386), (Order SD355R(A)/SD365R(A)separately.) BG-12LX (DF-52013), CMF-300-6 (DF-52365), CRF-300-6 (DF-52374), CMF/CRF Series (DF-52130), CP355 (DF-52383), H355 Series (DF- DNRW: InnovairFlex low-flow non-relay duct-detector housing, with 52385), 1300 (DF-52389), ISO-6 (DF-60485), MMF-300 Series/MDF-300 NEMA-4 rating. Watertight. (Order SD355R(A)/SD365R(A) sepa- (DF-52121), MMF-300-10 (DF-52347), MMF-302-6 (DF-52356), SD355/ rately.) SD355T(DF-52384),and SLC Wiring Manual(51309). Addressable Modules NOTE:Legacy 300 Series detection devices such as the CP300/CP350, MMF-300(A): Addressable Monitor Module for one zone of normally- SD300(T)/SD350(T) and older modules such as the M300, M301, M302, open dry-contact initiating devices. Mounts in standard 4.0" (10.16 C304, and BG-10LX are not compatible with LiteSpeed polling. If the SLC cm.)box. Includes plastic cover plate and end-of-line resistor. Module contains one of these devices,polling must be set for standard CLIP proto- may be configured for either a Class B or Class A IDC. col. Please consult factory for further information on previous 300 Series devices. MDF-300(A): Dual Monitor Module. Same as MMF-300(A) except it provides two Class B-only IDCs. ADDRESSABLE DEVICE ACCESSORIES MMF-301(A): Miniature version of MMF-300(A). Excludes LED and End-of-Line Resistor Assembly(R-47K and R-3.9K):The 47k ohm Class A option.Connects with wire pigtails.May mount in device back- assembly supervises the MMF-300(A), MDF-300(A), MMF-301(A), box. and CMF-300(A) module circuits. The 3.9k ohm assembly supervises MMF-302(A):Similar to MMF-300(A).Addressable Monitor Module for the MMF-302(A) module circuit. These resistors are included with one zone of conventional two-wire detectors. Requires resettable 24 each module. VDC power. Refer to the Device Compatibility Document for listed Power Supervision Relay: Supervises the power to 4-wire smoke compatible devices and quantity limitation. detectors and notification appliances. CMF-300(A):Addressable Control Module for one Class B or Class A zone of supervised polarized Notification Appliances. Mounts directly Wiring Requirements to a 4.0" (10.16 cm.) electrical box. NAC option requires external 24 While shielded wire is not required, it is recommended that all SLC VDC to power notification appliances. (DCL)wiring be twisted-pair to minimize the effects of electrical inter- CRF-300(A): Addressable relay module containing two isolated sets ference. Refer to the panel manual for wiring details. of Form-C contacts,which operate as a DPDT switch. Mounts directly to a 4.0"(10.16 cm.)box,surface mount using the SMB500. DF-60957:D•3/27/2023—Page 3 of 4 SYSTEM SPECIFICATIONS System Capacity NFPA Standards • Intelligent Signaling Line Circuits 1 The ES-200X complies with the following NFPA 72 Fire Alarm Sys- • Addressable device capacity 198 tems requirements: • Programmable software zones 99 —LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- • Annunciators 16 sory). —AUXILIARY (Automatic, Manual and Waterflow) (requires Electrical Specifications 4XTMF). —REMOTE STATION(Automatic,Manual and Waterflow)(Where a AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, DACT is not accepted, the alarm,trouble and supervisory relays auto-sensing- no switch required. Wire size: minimum 14 AWG (2.00 may be connected to UL 864 listed transmitters. For reverse mm2)with 600 V insulation. Non-power-limited,supervised. polarity signaling of alarm and trouble,4XTMF is required.) Battery: Two 12 V 18 AH lead-acid batteries.Battery Charger Capac- —PROPRIETARY(Automatic, Manual and Waterflow). ity: 7-18 AH (ES-200X cabinet holds maximum of two 18 AH batter- —CENTRAL STATION (Automatic, Manual and Waterflow, and ies.) Sprinkler Supervised). Communication Loop: Supervised and power-limited. —OT,PSDN(Other Technologies, Packet-switched Data Network) Notification Appliance Circuits: Terminal Block provides connec- —IBC 2012,IBC 2009,IBC 2006,IBC 2003,IBC 2000(Seismic). tions for four NACs, Class B or Class A. Special Application power. —CBC 2007(Seismic) Power-limited,supervised circuitry.Maximum signaling current per cir- cuit: 2.5 amps special application, 250mA regulated. End-of-Line Resistor: 4.7k ohm, 1/2 watt (P/N 71252 UL listed) for Class B NAC; Agency Listings and Approvals system capable of 1.9 k52 - 22 k52 ELR range. Refer to the Fire•Lite The listings and approvals below apply to the basic ES-200X control Device Compatibility Document for listed compatible devices. panel. In some cases, certain modules may not be listed by certain Two Programmable Relays and One Fixed Trouble Relay: Con- approval agencies,or listing may be in process.Consult factory for lat- tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). est listing status. Form-C relays, non-power-limited, non-supervised. ES-200X,ES-200XC,ES-200XI Cabinet Specifications • UL: S624 • FM approved Door: 19.26" (48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.72" (1.82 • CSFM:7165-0075:0500 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 cm.) • FDNY:COA#2021-TMCOAP-009618-AMD wide x 5.25"(13.34 cm.)deep.Trim Ring(TR-CE):22.00"(55.88 cm.) high x 19.65"(49.91 cm.)wide. ES-200XP • ETL: 5017286 Shipping Specifications • CSFM:7165-0075:0511 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0—49°C/32— 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at 32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's standby batteries and the electronic components may be adversely affected by extreme temperature ranges and humidity.Therefore, it is recommended that this system and its peripherals be installed in an environment with a normal room temperature of 15—27°C/60—80°F. InnovairFlexTM and LiteSpeed1M are trademarks and AlarmNeti5, Fire-Lite® Alarms, SWIFT®, and System Sensor®are registered trademarks of Honeywell International Inc. AT&T® is a registered trademark of the AT&T Properties, L.P.Verizon® is a registered trademark of Verizon Trademark Services LLC. Microsoft®and Windows®are registered trademarks of the Microsoft Corporation. ©2023 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. cs T All specifications are subject to change without notice. MINN N6 S MANEIUMIS QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:USA www,firelite.com Page 4 of 4—DF-60957:D•3/27/2023 HN Series Effective November 2016 HS Series Technical Data TD450049EN supersedes October 2014 ST Series Exceder Strobe, Horn Strobe, and Horn Notification liances Description The Wheelock Exceder Series of notification appliances feature a sleek modern design that will please building owners r with reduced total cost of ownership. Installers will benefit from x its comprehensive feature list, including the most candela options in one appliance,low current draw, no tools needed for setting changes,voltage test points, 12/24VDC operation, universal mounting base and multiple mounting options for both new and retrofit construction. I , The Wheelock Exceder Series incorporates high reliability and high efficiency optics to minimize current draw allowing fora greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single a rEE s appliance. Models with an audible feature 3 sound settings(90, 95, 99 dB).All switches to change settings,can be set without the use of a tool and are located behind the appliance to prevent tampering. ' Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock Exceder Series of wall and ceiling notification . appliances feature a Universal Mounting Base(UMB) designed ;: to simplify the installation and testing of horns,strobes,and combination horn strobes.The separate universal mounting base can be pre-wired to allow full testing of circuit wiring before the � �� , \ \� \ � appliance is installed and the surface is finished. It comes complete � t with a Contact Cover for protection against dirt, dust, paint and \\ damage to the contacts.The Contact Cover also acts as a shunting device to allow pre-wire testing for common wiring issues. . The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while it is on the UMB. When the Contact Cover is removed the circuit will show an open until the appliance is installed.The UMB allows for consistent installation and easy replacement of appliances if required.Wall models provide an optional locking screw for extra secure installation, while the ceiling models provide a captivated screw to prevent the screw from falling during installation. Elf N Powering Business Worldwide Technical Data TD450049EN HN Seriee Effective November 2016 HS Series • ST Series Features • Environmentally friendly • • Sleek modern aesthetics Low current draw • Finger slide switches • Up to 9 models now in 1 appliance draw0 • Voltage test points • 12/24VDC on a single appliance • Multiple voltages • Easy to remember model numbers • 3 Audible settings 0 Patented • 90,95,99 dB - Note:Please read these specifications and associated installation instruc- tions,before using,specifying,or installing this product.Visit Eaton.com( • Industry leading-8 candela settings on 1 device massnotification for current installation instructions. • Wall: 15/1575/30/75/95/110/135/185 • Ceiling: 15/30/60/75/95/115/150/177 General Notes • Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range. • All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. • Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F (0°C to 49°C)and maximum humidity of 93% (t 2%) UL 464(85% UL 1971). • Series Exceder horns are under UL Standard 464 for audible signal appliances (Indoor use only). Compatibility and requirements • Synchronize using the Wheelock°Sync Modules or panels with built-in Wheelock® Patented Sync Protocol • Compatible with UL"Regulated Voltage" using filtered VDC or • Universal mouting base unfiltered VRMS input voltage • Ceiling and wall • Strobes produce 1 flash per second over the"Regulated • Mounts to 5 backbox types: 1 gang, 2 gang, 4" square, Voltage" range 3.5" octal. &4"octal. (100mm for international customers) Universal mounting base Contact cover Compliance • UL 1971, UL 464, ULC, CSFM, FM • ADA/N FPA/AN SI/OS HA • RoHS Common base for wall and ceiling with 5 mounting options • Voltage test points for quick troubleshooting and easy spot checking(wall models only) V 0 2 EATON www.eaton.com - I Series Technical Data TD450049EN HS Series Effective November 2016 ST Series Table 1. Strobe Ratings per UL Standard 1971 UL Max Current® 24 VDC/24 FWR 12 VDC Regulated Voltage Model Range VAC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 ST 8.0-33.0 0.057 0.070 0.085 - 0.135 0.163 0.182 - 0.205 - - 0.253 0.110 0.140 STC 8.0-33.0 0.061 - 0.085 0.103 0.135 0.163 - 0.182 - 0.205 0.253 - 0.110 - Table 2. Horn Strobe Ratings per UL 1971 &Anechoic at 24VDC UL Max Current®at Anechoic 99 dBA 24 VDC 12 VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.082 0.095 0.102 - 0.148 0.176 0.197 - 0.242 - - 0.282 0.125 0.159 HSC 8.0-33.0 0.082 - 0.102 0.141 0.148 0.176 - 0.197 - 0.242 0.282 - 0.125 - UL Max Current®at Anechoic 95 dBA 24VDC 12VDC Regulated Voltage Model Range VDC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.073 0.083 0.087 - 0.139 0.163 0.186 - 0.23D - - 0.282 0.122 0.153 HSC 8.0-33.0 0.073 - 0.087 0.128 0.139 0.163 - 0.186 - 0.230 0.272 - 0.122 - UL Max Current®at Anechoic 90 dBA 24 VDC 12 VDC Regulated Voltage Model Range VOC 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 HS 8.0-33.0 0.065 0.075 0.084 - 0.136 0.157 0.184 - 0.226 - - 0.267 0.120 0.148 HSC 8.0-33.0 0.065 - 0.084 0.120 0.136 0.157 - 0.184 - 0.226 0.267 - 0.120 - ,0 UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units).For strobes the UL max current is usually at the minimum listed voltage(16 VDC for 24 UDC unitsl.For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units).For unfiltered ratings,see installation instructions. Table 3. Horn Ratings per UL Anechoic Model Legend Regulated Voltage Model Range VDC 99 dB 95 dB 90 dB HN - Horn R = Red HN 16-33.0 0.064 0.044 0.022 ST = Strobe A = Agent Lettering(strobes only) HNC 16 33.0 0.084 0.044 0.022 HS = Horn Strobe AL = Alert Lettering(strobes only) HN 8.0-17.5 0.047 0.026 0.017 C = Ceiling Mount N = No Lettering(strobes only) HNC 8.0-17.5 0.047 0.026 0.017 W - White Example 1:STRC=Strobe,Red,Ceiling Mount Table 4. Specification&Ordering Information Example 2:HSR=Horn Strobe,Red,Wall Mount 5nc w/DSM or Example 3:HSW=Horn Strobe,White,Wall Mount InYheelocic Power 12/24 Mounting Example 4:STW-AL=Strobe,White,Wall Mount,Alert Lettering Model Strobe Candela Supplies VDC'® Options Horn Strobes HSR 15/1575/30/75/95/110/135/185 X X UM BC' HSW 15/1575/30/75/95/110/135/185 X X UMB® i iT I�, ' HSRC 15/30/60/75/95/115/150/177 X X UMBD • HSWC 15/30/60/75/95/115/150/177 X X UMB® °Q� = 1. � Strobes i �� �� a STR 15/1575/30/75/95/110/135/185 X X UMB® ' -' �e .� STW 15/1575/30/75/95/110/135/185 X X UMBD 1 STRC 15/30/60/75/95/115/150/177 X STWC 15/30/60/75/95/115/150/177 X X UMBD Horn HNR . X UMB® HNW iIsai: Ets X X UMB® HNRCz:z ®O 2 X X UMB Example:HSR Example:HSWC HNWC X X UMBQ p O 12 VDC models feature 15&15/75 settings O UMB=Universal Mounting Base EATON www.eaton.com 3 Technical Data TD450049EN HN Serie, Effective November 2016 HS Series '' ST Series • Architects and Engineers Specifications The notification appliances shall be Wheelock Exceder Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service.The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling).All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel (FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design.Where multi- candela appliances are specified,the strobe intensity shall have 8 field selectable settings at 15, 15/75,30, 75,95, 110, 135, 185 candela for wall mount and 15,30,60, 75,95, 115, 150, 177 candela for ceiling mount.The selector switch for selecting the candela shall be tamper resistant.The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.,ADA compliance).Appliances wth candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three (3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang,4-inch square,3.5-inch octal,4-inch octal or 100mm European type back boxes.Two wire appliance wiring shall be capable of directly connecting to the mounting base.Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP).The mounting base shall be the same base among all horn, strobe, horn strobe,wall and ceiling models.All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24" H x 4.58"W x 2.19" D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68" x 2.63" D. Series HNC ceiling shall have a diameter of 6.68" x 1.50" D. When synchronization is required, the appliance shall be compatible with Wheelock's DSM Sync Modules,Wheelock Power Supplies or other manufacturer's panels with built-in Wheelock Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate,the strobe shall revert to a non-synchronized flash-rate and still maintain(1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with.Wheelock synchronization protocol. Wall Appliances: UL Standard 1971, UL Standard 464,California State Fire Marshal (CSFM), ULC, FM, RoHS Ceiling Appliances: UL Standard 1971, UL Standard 464, California State Fire Marshal ICSFM), ULC, FM, RoHS Note:Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Eaton standard terms and conditions. Member WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Eaton 1000 Eaton Boulevard Cleveland,OH 44122 United States Eaton.com Eaton Life safety&mass notification solutions 273 Branchport Ave. Long Branch,NJ 07740 Eaton.com/massnotification ©2016 Eaton All Rights Reserved Eaton is a registered trademark. E '�• Printed in USA Publication No.TD450049EN All other trademarks are property Powering Business Worldwide November 2016 of their respective owners. DF-61011:C H365 Series Addressable Heat Detectors Fe' .uTeALC rms by Honeywell The Fire•Lite® Alarms H365(A), H365R(A), and H365HT(A) �•�� addressable plug-in thermal detectors are designed for both perfor- mance and aesthetics and are a direct replacement for the H355 ,0 Series. A new modern, sleek, contemporary design and advanced thermal technologies make the H365(A)Series ideal for both system operation and building design. aafi ��o ec Exclusively for use with Fire•Lite's addressable fire alarm control ai panels,the H365(A)Series point ID capability allows each detector's address to be set with rotary, decimal address switches, providing athin `€E „1 u jimmomotimikinsomg exact detector location for emergency personnel to quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage. Two LEDs on each sensor „€€, Egoollue light to provide a local,visible sensor indication. I `` The H365(A) Series includes fixed temperature, rate-of-rise and high heat fixed temperature detectors that provide effective, intelli- gent property protection for a variety of applications. Detectors are available for both LiteSpeedTM and CLIP applications as designated. Features SLC LOOP: OPTIONS: • Two-wire SLC loop connection • Remote LED output connection to optional RA100Z remote LED • Unit uses base for wiring annunciator ADDRESSING: Installation • Addressable by device • Rotary,decimal addressing H365 Series plug-in intelligent thermal detectors use a detachable (Refer to the Fire•Lite panel manuals for device capacity.) base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. ARCHITECTURE: Mount detector base(all base types)on an electrical backbox which • Designed to meet UL 268 7th Edition is at least 1.5" (3.81 cm) deep. For a chart of compatible junction • Sleek,low-profile,stylish design boxes,see DF-60059. • State-of-the-art thermistor technology for fast response NOTE:Because of the inherent supervision provided by the SLC loop, • Integral communications and built-in device type identification end-of-line resistors are not required. Wiring "T-taps"or branches are permitted for Style 4(Class"B")wiring only. • Built-in tamper resistant feature When using relay or sounder bases, consult the 1300(A) installation • Built-in functional test switch activated by external magnet sheet 156-3626 for device limitations between isolator modules and iso- lator bases. OPERATION: • Fixed temperature model (H365(A)) factory preset to 135°F Applications (57°C) Use thermal detectors for protection of property.For further informa- • Rate-of-rise model(H365R(A)), 15°F(8.3°C)per minute tion, refer to 156-6525, Applications Manual for System Smoke • High-temperature model (H365HT(A)) factory preset to 190°F Detectors, which provides detailed information on detector spacing, (88°C) placement,zoning,wiring,and special applications. • 360°-field viewing angle of the two visual alarm indicators, LEDs blink red in Normal condition and turn on steady red in Alarm Construction • LEDs blink every time the unit is polled These detectors are constructed of fire-resistant plastic. The H365 MECHANICALS: Series plug-in intelligent thermal detectors are designed to commer- cial standards and offer an attractive appearance. • Sealed against back pressure • SEMS screws for wiring of the separate base Operation • Designed for direct-surface or electrical-box mounting Each H365 Series detector uses one of the panel's addresses(total • Plugs into separate base for ease of installation and maintenance limit is panel dependent) on the Fire•LiteJCI Signaling Line Circuit • Separate base allows interchange of photoelectric, ionization and (SLC).It responds to regular polls from the control panel and reports thermal sensors its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an OTHER SYSTEM FEATURES: alarm. It blinks its LEDs when polled and turns the LEDs on when • Remote test feature from the panel commanded by the panel.The H365 Series offers features and per- • Walk test with address display formance that represent the latest in thermal detector technology. • Low standby current DF-61011:C•11/18/2019—Page 1 of 3 Product Line Information B200SA-IV:Same as B200S-IV, ULC listing NOTE:"-IV"suffix indicates CLIP and LiteSpeed device. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO NOTE:"A"suffix indicates Canadian version. Series detector applications H365:White, low profile intelligent 135°F fixed thermal sensor, Lite- B200SCOA-IV: Ivory Intelligent, programmable sounder base in Speed only English/French (required in Canada for ULC applications with CO H365A:Same as H365 but with ULC listing Series detector applications, ULC listing H365-IV: Ivory, low-profile intelligent 135°F fixed thermal sensor, B200S-LF-WH: White, Low Frequency Intelligent, programmable LiteSpeed and CLIP sounder base. Produces a fundamental frequency of 520 Hz +/- H365A-IV: Same as H365-IV but with ULC listing 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) H365R: White, low-profile intelligent rate-of-rise thermal sensor, LiteSpeed only B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- H365RA: Same as H365R but with ULC listing 10% with a square wave or its equivalent; designed to meet the H365R-IV: Ivory,low-profile intelligent rate-of-rise fixed thermal sen- NFPA 72 sleeping space requirement. (CSFM:7300-1653:0238) sor, LiteSpeed and CLIP B200SR-WH: White, Intelligent sounder base capable of producing H365RA-IV:Same as H365R-IV but with ULC listing sound output with ANSI Temporal 3 or continuous tone. Intended for H365HT: White, low-profile intelligent 190°F fixed thermal sensor, retrofit applications. (CSFM: 7300-1653:0213) LiteSpeed only B200SR-IV: Ivory, Intelligent sounder base capable of producing H365HTA:Same as H365H but with ULC listing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM:7300-1653:0213) H365HT-IV: Ivory, low-profile intelligent 190°F thermal sensor, Lite- B200SRA-WH:Same as B200SR-WH with,ULC listing Speed and CLIP H365HTA-IV Same as H365H-IV but with ULC listing B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- NOTE:For details on intelligent bases,see DF-60059. 10% with a square wave or its equivalent; designed to meet the B300-6:White,6"base,standard flanged low-profile mounting base NFPA 72 sleeping space requirement. Intended for retrofit appiica (CSFM: 7300-1653:0109) tions. (CSFM: 7300-1653:0238) B300-6-IV: Ivory,6" base, standard flanged low-profile mounting B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable base(CSFM: 7300 1653:0109) sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the B300A-6:Same as B300-6, ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base, tions. (CSFM: 7300-1653:0238) ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP:Bulk pack of B300-6,package contains 10 TR300:White,replacement flange for B210LP(A)base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A)base base. UL/ULC listed (CSFM:7300-1653:0109) RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box. For use with B501(A)and B300-6(A). UL/ULC listed(CSFM:7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting base. UL/ULC listed (CSFM: 7300-1653:0109) M02-09-00:Test magnet with telescoping handle B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 CK300:Color Kit(includes cover and trim ring),white, 10-pack B224RB-WH:White,relay base(CSFM: 7300-1653:0216) CK300-IV:Color Kit(includes cover and trim ring), ivory, 10-pack B224RB-IV: Ivory, relay base(CSFM:7300-1653:0216) CK300-BL: Color Kit(includes cover and trim ring), black, 10-pack B224RBA-WH:White, relay base, ULC listing B224RBA-IV: Ivory,relay base, ULC listing B224BI-WH:White,isolator detector base(CSFM:7300-1653:0216) B224BI-IV:Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH:White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200SA-WH: Same as B200S-WH,ULC listing Page 2 of 3—DF-61011:C•11/18/2019 SYSTEM SPECIFICATIONS Size:2.0"(5.3 cm)high;base determines diameter -B300-6: 6.1"(15.6 cm)diameter -B501:4"(10.2 cm)diameter For a complete list of detector bases see DF-60983 Shipping weight:3.4 oz.(95 g) Operating temperature range: • H365, H365R Series:-4°F to 100°F(-20°C to 38°C) • H365H Series:-4°F to 150°F(-20°C to 66°C) Detector spacing: UL approved for 50 ft. (15.24 m)center-to-cen- ter,FM approved for 25 x 25 ft.(7.62 x 7.62 m)spacing Relative humidity: 10%-93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of- rise detection 15°F(8.3°C)per minute,high temperature heat 190°F (88°C) Mounting:B300-6(A)flanged base,included See"Product Line Information: Intelligent Bases," if using a dif- ferent base. ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") Listings and Approvals Listings and approvals below apply to the H365 Series detectors. In some cases, certain modules may not be listed by certain approval agencies,or listing may be in process.Consult factory for latest list- ing status. • UL/ULC Listing:S2517 • FM Approved • CSFM:7272-0075:0501 LiteSpeed'M is a trademark and Fire•L ite®Alarms is a registered trademark of Honeywell International Inc. (02019 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. A This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. E R T I F I E Ek All specifications are subject to change without notice. ENGINEERING&MANUFACTUUING QUALITY SYSTEMS For more information,contact Fire-Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. .Country of Origin:Mexico www.firelite.com Page 3 of 3—DF-61011:C•11/18/2019 DF-61010:B SD365 Series e(1144 Addressable Photoelectric Smoke Detectors Flre•LITGALc rms by Honeywell \ • The Fire•Lite® Alarms SD365(A), SD365R(A), and SD365HT(A) intelli-gent plug-in smoke detectors are designed for both performance and aesthetics, and are direct replacements for the SD355 Series. A new modern, sleek, contemporary design and enhanced optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. e vvoffv��0vval* 01:4-* Exclusively for use with Fire•Lite's addressable fire alarm control panels, the SD365(A) Series point ID capability allows each detec- 1r tor's address to be set with rotary,decimal address switches,provid- IEfF,EfE € ing exact detector location for emergency personnel to quicklyF locate a fire during its early stages, potentially saving precious res- cue time while also reducing property damage. Two LEDs on each sensor light to provide a local,visible sensor indication. Ed The SD365(A) Series also offers 135°F (57°C) fixed temperature thermal sensing on the SD365T(A)and a remote test capable detec- tor on the SD365R(A) for use with DNR(A)/DNRW duct smoke detector housings. Features • Plugs into separate base for ease of installation and maintenance SLC LOOP: • Separate base allows interchange of photoelectric, ionization and • Two-wire SLC loop connection thermal sensors • Unit uses base for wiring OPTIONS: • Compatible with LiteSpeedTM and CLIP protocol systems • Optional relay, isolator,and sounder bases • Stable communication technique with noise immunity Installation ADDRESSING: SD365 Series plug-in intelligent smoke detectors use a detachable • Addressable by device base to simplify installation, service and maintenance. Installation • Rotary,decimal addressing instructions are shipped with each detector. (Refer to the Fire•Lite panel manuals for device capacity.) Mount detector base(all base types)on an electrical backbox which ARCHITECTURE: is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes,see DF-60059. • Sleek,low-profile,stylish design NOTE:Because of the inherent supervision provided by the SLC loop, • Unique single source design to respond quickly and dependably to a broad range of fires end-of-line resistors are not required. Wiring "T-taps"or branches are permitted for Style 4(Class"B")wiring only. • Integral communications and built-in device-type identification When using relay or sounder bases, consult the 1300(A) installation • Built-in tamper resistant feature sheet 156-3626 for device limitations between isolator modules and iso- lator bases. • Remote test feature from the panel • Walk test with address display(an address on 121 will blink the Construction detector LED: 12 [pause] 1(LiteSpeed systems only) These detectors are constructed of fire-resistant plastic.The SD365 • Built-in functional test switch activated by external magnet Series plug-in intelligent smoke detectors are designed to commer- • Removable cover and insect-resistant screen for simple field cial standards and offer an attractive appearance. cleaning • Expanded color options Operation OPERATION: Each SD365 Series detector uses one of the panel's addresses (total limit is panel dependent)on the Fire•Lite Signaling Line Circuit • Designed to meet UL 268 7th Edition (SLC). It responds to regular polls from the control panel and reports • Factory preset at 1.5%nominal sensitivity for panel alarm thresh- its type and the status. If it receives a test command from the panel old level (or a local magnet test), it stimulates its electronics and reports an • LED "blinks"when the unit is polled (communicating with the fire alarm. It blinks its LEDs when polled and turns the LEDs on when panel)and latches in alarm, commanded by the panel. The SD365 Series offers features and performance that represent the latest in smoke detector technology. • Low standby current MECHANICALS: Detector Sensitivity Test • Sealed against back pressure Each detector can have its sensitivity tested(required per NFPA 72, Chapter 14 on Inspection, Testing and Maintenance)when installed/ • SEMS screws for wiring of the separate base connected to an Fire•Lite addressable fire alarm control panel. The • Designed for direct-surface or electrical-box mounting results of the sensitivity test can be printed for record keeping. DF-61010:B-71/2019—Page 1 of 3 Product Line Information B200SA-WH:Same as B200S-WH, ULC listing NOTE:"-IV"suffix indicates CLIP and LiteSpeed device. B200SA-IV: Same as B200S-IV,ULC listing NOTE:"A"suffix indicates Canadian version. B200SCOA-WH: White, Intelligent, programmable sounder base in EnSD365:White,low-profile intelligent photoelectric sensor, LiteSpeed Se91es detector applications(requiredin Canada for ULC applications with CO only SD365A: Same as SD365 but with ULC listing B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with CO SD365-IV: Ivory,low-profile intelligent photoelectric sensor Series detector applications,ULC listing SD365A-IV:Same as SD365-IV but with ULC listing B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- SD365T:White,same as SD365 but includes a built-in 135°F(57°C) 10% with a square wave or its equivalent; designed to meet the fixed-temperature thermal device, LiteSpeed only NFPA 72 sleeping space requirement.(CSFM:7300-1653:0238) SD365TA: Same as SD365T but with ULC listing B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable SD365T-IV: Ivory, same as SD365T but includes a built-in 135°F sounder base. Produces a fundamental frequency of 520 Hz +/- (57°C)fixed-temperature thermal device 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM:7300-1653:0238) SD365TA-IV:Same as SD365T-IV but with ULC listing B200SR-WH: White, Intelligent sounder base capable of producing SD365R: White, low-profile intelligent photoelectric sensor, remote sound output with ANSI Temporal 3 or continuous tone. Intended for test capable,for use with DNR/DNRW, LiteSpeed only retrofit applications. (CSFM:7300-1653:0213) SD365RA: Same as SD365R but with ULC listing, for use with B200SR-IV: Ivory, Intelligent sounder base capable of producing DNRA sound output with ANSI Temporal 3 or continuous tone.Intended for SD365R-IV:Ivory,low-profile intelligent photoelectric sensor,remote retrofit applications. (CSFM:7300-1653:0213) test capable,for use with DNR/DNRW B200SRA-WH:Same as B200SR-WH with,ULC listing SD365RA-IV: Same as SD365R-IV but with ULC listing,for use with B200SRA-IV: Same as B200SR-IV in Ivory color,ULC listing DNRA B200SR-LF-WH: White, Low Frequency Intelligent, programmable INTELLIGENT BASES sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NOTE:For details on intelligent bases,see DF-60059. NFPA 72 sleeping space requirement. Intended for retrofit applica- B300-6:White,6"base,standard flanged low-profile mounting base tons. (CSFM: 7300-1653:0238) (CSFM: 7300-1653:0109) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable B300-6-IV: Ivory,6" base, standard flanged low-profile mounting sounder base. Produces a fundamental frequency of 520 Hz +/- base(CSFM:7300-1653:0109) 10% with a square wave or its equivalent; designed to meet the Same as B300-6, ULC listed NFPA 72 sleeping space requirement. Intended for retrofit applica- B300A-6: tions. (CSFM: 7300-1653:0238) B300A-6-IV: Ivory, 6" standard flanged low-profile mounting base,ULC listed MOUNTING KITS AND ACCESSORIES B300-6-BP:Bulk pack of B300-6,package contains 10 TR300:White, replacement flange for 6210LP(A)base B501-WHITE: White, 4" standard European flangeless mounting TR300-IV: Ivory, replacement flange for B210LP(A)base base. UUULC listed (CSFM:7300-1653:0109) RA100Z(A): Remote LED annunciator. 3-32 VDC. Mounts to a U.S. B501-BL: Black, 4" standard European flangeless mounting base. single-gang electrical box. For use with B501(A)and B300-6(A). UL/ULC listed (CSFM: 7300-1653:0109) M02-04-00:Test magnet B501-IV: Ivory color, 4" standard European flangeless mounting M02-09-00:Test magnet with telescoping handle base. UL/ULC listed (CSFM:7300-i1653:0109) CK300:Color Kit(includes cover and trim ring),white, 10-pack B501-WHITE-BP: Bulk pack of B501-WHITE contains 10 CK300-IV: Color Kit(includes cover and trim ring), ivory, 10-pack B224RB-WH:White,relay base(CSFM:7300-1653:0216) CK300-BL: Color Kit(includes cover and trim ring),black, 10-pack B224RB-IV:Ivory, relay base(CSFM:7300-1653:0216) B224RBA-WH:White,relay base, ULC listing B224RBA-IV:Ivory,relay base,ULC listing B224B1-WH:White,isolator detector base(CSFM:7300-1653:0216) B224B1-IV:Ivory isolator detector base(CSFM:7300-1653:0216) B224BIA-WH:White, isolator detector base, ULC listing B224BIA-IV: Ivory isolator detector base, ULC listing B200S-WH:White,Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4,continuous tone,marching tone,and custom tone. Uses FlashScan protocol. (CSFM:7300-1653:0213) Page 2 of 3—DF-61010:B•71/2019 SYSTEM SPECIFICATIONS Sensitivity: Listings and Approvals • UL Applications:0.5%to 4.0%per foot obscuration. Listings and approvals below apply to the SD365 Series detectors. • ULC Applications:0.5%to 3.5%per foot obscuration In some cases, certain modules may not be listed by certain Size:2.0"(5.3 cm)high;base determines diameter approval agencies, or listing may be in process.Consult factory for latest listing status. —B300-6: 6.1"(15.6 cm)diameter —B501:4"(10.2 cm)diameter • UUULC Listing:S1059 • For a complete list of detector bases see DF-60983 FM Approved • CSFM:7272-0075:0502 Shipping weight:3.4 oz.(95 g) Operating temperature range: • SD365:32°F to 122°F(0°C to 50°C) • SD365T Series:32°F to 100°F(0°C to 38°C) • SD365R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C to 70°C) UUULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), suitable for installation in ducts Relative humidity: 10%—93%non-condensing Thermal ratings:fixed-temperature set point 135°F(57°C),rate-of- rise detection 15°F(8.3°C)per minute,high temperature heat 190°F (88°C) ELECTRICAL SPECIFICATIONS Voltage range: 15-32 volts DC peak Standby current(max.avg.):200pA @ 24 VDC(one communica- tion every 5 seconds with LED enabled) Max current:4.5 mA @ 24 VDC("ON") DETECTOR SPACING AND APPLICATIONS Fire•Lite recommends spacing detectors in compliance with NFPA 72. In low airflow applications with smooth ceiling, space detectors 30 feet(9.1m). For specific information regarding detector spacing, placement, and special applications refer to NFPA 72. A System Smoke Detector Application Guide, document A05-1003, is avail- able at www.systemsensor.com. LiteSpeedTA4 is a trademark, and Fire•Lite®Alarms and System Sensor® are registered trademarks of Honeywell International Inc. ®2019 by Honeywell international Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. C E R T I F 1 .§31 All specifications are subject to change without notice. • EElM LN6&MMfUNC RU QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. Country of Origin:Mexico www.firelite.com Page 3 of 3—DF-61010:B•71/2019 DF-52013:D•E-100 BG-1 2LX FIre•LITsALarms Addressable Manual Pull Station by Honeywell General The Fire•Lite BG-12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface (mounted inside) for Fire•Lite's addressable fire alarm control panels (FACPs) Because the BG-12LX is addressable, the control panel can display the exact location of the activated manual station.This leads fire personnel quickly to the location of the alarm. Features PUSH IN • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. � • Captive screw terminals wire-ready for easy connection to ' FIretr Af SLC loop(accepts up to 12 AWG/3.25 mm2 wire). by Honeywell r • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. • Meets ADAAG controls and operating mechanisms guide- LL lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. usually needed for semi-flush mounting with 4" (10.16 cm) or • Attractive shape and textured finish, double-gang boxes(not with single-gang boxes). • Key reset. • Includes Braille text on station handle. Operation • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched, the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station. To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —159 with Breakaway Tab removed for MS-9600 Series, 1 — • Shipping Weight:9.6 oz.(272.15 g) 99 and MS-92000DLS, 1 —50 for MS-9050UD). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot • For use indoors in a dry location be restored to normal except by use of a key.An operated sta- tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The BG-12LX will mount semi-flush into a single-gang,double- ing instructions provided on the cover. The word FIRE shall gang,or standard 4"(10.16 cm)square electrical outlet box,or appear on the front of the stations in white letters, 1.00 inches will surface mount to the model SB-10 or SB-I/O surface back- (2.54 cm) or larger. Stations shall be suitable for surface box. If the BG-12LX is being semi flush mounted, then the mounting on matching backbox SB-10 or SB-I/O;or semi-flush optional trim ring (BG12TR) may be used. The BG12TR is mounting on a standard single gang, double gang, or 4"(10.16 cm) square electrical box, and shall be installed DF-52013:D•4/13/2012—Page 1 of 2 • • within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the • state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information BG-12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian appli- cations.) SB-10:Surface backbox;metal. SB-I/O:Surface backbox;plastic. BG12TR:Optional trim ring. 17003: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UUULC Listed: S711 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E. • CSFM:7150-0075:0184. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6.314,772; 6,632,108. FireLite®Alarms®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ` This document is not intended to be used for installation purposes. 'SO 9001 We try to keep our product information up-to-date and accurate. E R T I F I E We cannot cover all specific applications or anticipate all requirements. I j EN&lNEERI A&MAN&FRGNRIN& All specifications are subject to change without notice. Made in the U.S.A. QUALITY SYSTEMS For more information,contact Fire•Lite Alarms.Phone:(800)627-3473,FAX:(877)699-4105. www.firelite.com Page 2 of 2—OF-52013:D•4/1 312 01 2