Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YAdRMOUTH-" SEWAGE PLAN REVIEW CHECKLIST it Location: A.M. Lot 2 (D: Zone of Contribution: In OutC"---(Acreagie Commercial: Residential: Street: 27 CA/ Zio /Village: (,(/ 8V/ Floor Plan: , #Bedrooms: 3 Owner: (`]` : � ") S Installer: --'1 i& 4 Address: Phone: -77 3 Phone: Builder: Engineer: // C __ Address: Phone: -7?� X°f 7 Phone: N/A YES NO 1. Required# of copies received , ,7 2. Date of soils exam and percolation test not older than 2 years `� 3. 4-5 ft of naturally occurring pervious material, above water table 4.Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: ✓/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: L. 9. Leaching minimum 100 ft from wetlands Var.: L.---- 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: -J 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: / kid 13. Uses adjustment for maximum high groundwater Var.: ( ' ) i 2,- efe l, C 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: I , J 15. System not in top or subsoil(A,B horizons)©r 5' removal/ 16.Proposed contours are suitable L. 17. System meets slope requirements-min. 1/8", 1/4"preferred 1/e! ` 18. System meets breakout requirements PVC liner: A Q r+r Wall: .. ,./ 19. Specified tee sizes are proper, gas baffle on outlet tee f 20. Sewage is under 10,000 gpd for parcel f/ 21.No garbage disposal ,.. , 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox 24.Manhole covers within 6"of grade, pump chamber cover to grade ,/ 25. Inspection port on plastic chambers/leach field \i 26. Electrical permit for pump chamber/Separate meter for duplexes ✓ 27.Pump system-2" line,weep hole,check valve,tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet, under driveway/parking -..-7 30. Buoyancy calculations for tank/pump chamber ....-V; 31. Engineer to inspect and certify soils: wall: Ycommercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature .1 33. H-20 loading is subject to vehicular traffic, groundwater 34. Title V Application and permit fee, installer signature 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label groundwater in Assessor's Map Plan reviewed by: 6/03/03