Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot ,/,C/S'(/ Zone of Contribution: In Out Acreage /6 �6se 1 Commercial: Residential:Street: S� C'i Village: • y��",•� Floor Plan: # Bedrooms: Owner: CCU u(1 yv ico Installer: f Address: /b /�� � � � 'Cci vc.��'� . SC Phone: _ 7 06 57 Phone: i'`/-7- t0a3 Builder: Engineer: G u,C J v l5 Address: Phone: Phone: SZ, _ 3 6 t 6/ 1. Re.uired#of copies received NIA YES NO 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table J 4. Foundation 2 ft above high point of roadV - 5. Water line 10 ft from septic components Var.: Fnd: Var.: - - 6. Benchmark indicated and shown-NGVD if near wetlands II ✓ 7. Se. . •• •.'.'•. •• I i *HI II.•.. •. •- - 8. Leaching Var.: minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I 9. Leachin• minimum 100 ft from wetlands ar.: iii 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: I 11. Tank/leaching minimum 10 ft from •ro.ert line Var.: 12. System meets all other setback requirements Var.: _®-13. Uses ad ustment for maximum lush groundwater Var.: 14. Leaching set 4-5 ft above ad.. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal 111111211M1 16. Proposed contours are suitableIIIIIIMIII 1111.11111111111 17. System meets slope requirements- min. 1/8", 'A"preferred 18. S stem meets breakout re.uirements �- 19. Specified tee sizes are 'roper, as baffle on outlet tee PVC liner: Nall: ( - 20. Sewage is under 10,000 ,.d for parcel 21. No garbage disposal111.1111111111 22. System ade uately sized for its intended use 23:Minimum 6"stone or comp acted below tank and dbox 24. Manhole covers within 6"of grade, pump chamber cover to grade all. 25. Inspection sort on elastic chambers/leach field1111111111111111 26. Electrical permit for sum. chamber/Separate meter for duplexes M- 27. Rum. system-2"line,wee. hole,check valve, tee in dbox, sump size 28. Septic tank/sums chamber to be factory wate 'roofed 29. Vent .rovided if leaching below 3 feet,under driveway/parking _ 30. Buo anc calculations for Yank/s um. chamber _ 31. Engineer to ins.ect and certif y soils: wall: commercial: MI 32. Engineer/Re:istered Sanitarian and Land Surve or stamps/signature ,; 33.H 2Oloading is sub ect to vehicular traffic, : oundwater _ 34.Title V Ap.lication and permit fee, installer signature1111111011.111111111111 35. Foundation footing min. 2 feet above ad'usted ground water for new house _ 36. Deed Restriction re.uired max. -_ 37. Check area lots for oundwater/Label _ oundwater Assessor's Max. . d _ Plan reviewed by: -____,(LP44231-44