HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot ,/,C/S'(/ Zone of Contribution: In Out Acreage
/6 �6se 1 Commercial: Residential:Street: S� C'i
Village: •
y��",•� Floor Plan: # Bedrooms:
Owner: CCU u(1 yv ico Installer: f
Address: /b /�� � � � 'Cci vc.��'� .
SC Phone: _ 7 06 57
Phone: i'`/-7- t0a3
Builder: Engineer: G u,C J v l5 Address:
Phone: Phone: SZ, _ 3 6 t 6/
1. Re.uired#of copies received NIA YES NO
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material, above water table J
4. Foundation 2 ft above high point of roadV
-
5. Water line 10 ft from septic components Var.: Fnd: Var.: - -
6. Benchmark indicated and shown-NGVD if near wetlands
II ✓
7. Se. . •• •.'.'•. •• I i *HI II.•.. •. •- -
8. Leaching Var.:
minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I
9. Leachin• minimum 100 ft from wetlands ar.:
iii
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: I
11. Tank/leaching minimum 10 ft from •ro.ert line Var.:
12. System meets all other setback requirements Var.:
_®-13. Uses ad ustment for maximum lush groundwater Var.:
14. Leaching set 4-5 ft above ad.. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons)or 5' removal 111111211M1
16. Proposed contours are suitableIIIIIIMIII
1111.11111111111
17. System meets slope requirements- min. 1/8", 'A"preferred
18. S stem meets breakout re.uirements �-
19. Specified tee sizes are 'roper, as baffle on outlet tee PVC liner: Nall: ( -
20. Sewage is under 10,000 ,.d for parcel
21. No garbage disposal111.1111111111
22. System ade uately sized for its intended use
23:Minimum 6"stone or comp acted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade all.
25. Inspection sort on elastic chambers/leach field1111111111111111
26. Electrical permit for sum. chamber/Separate meter for duplexes M-
27. Rum. system-2"line,wee. hole,check valve, tee in dbox, sump size 28. Septic tank/sums chamber to be factory wate 'roofed
29. Vent .rovided if leaching below 3 feet,under driveway/parking _
30. Buo anc calculations for Yank/s um. chamber _
31. Engineer to ins.ect and certif
y soils: wall: commercial: MI
32. Engineer/Re:istered Sanitarian and Land Surve or stamps/signature
,;
33.H 2Oloading is sub ect to vehicular traffic, : oundwater _
34.Title V Ap.lication and permit fee, installer signature1111111011.111111111111
35. Foundation footing min. 2 feet above ad'usted ground water for new house _
36. Deed Restriction re.uired max. -_
37. Check area lots for oundwater/Label _ oundwater Assessor's Max. . d _
Plan reviewed by: -____,(LP44231-44