Loading...
HomeMy WebLinkAboutEngineer PlanPROJECT BENCH MARK TOP OF FOUNDATION ELEV. = 100.00 (ASSUMED) TEST HOLE /1 ELEV.= 98.50 e1500 GALLON SEPTIC TANK(EXIST 0 0 f 05.00' DECK FsHED S 0 0 cac«"e°z«Rd � N�sae wQ��s SITE LOCUS Rn W 1. Contractor is responsible for Digsafe notification, Verification of Utilities and protection of oil underground utilities and pipes. z 2. The septic tank on j distri¢ution box shall be set level on 6 of 3/4 -1 1/2" stone. 3. Bockfill should be clean sand or gravel with no stones over 3" in size. - 4. This system is subject to inspection during installation by Carmen E. Shay - Environmental Services, Inc. 5. The contractor shall install this system in accordance with Title V of the Massachusetts state code, the approved plan and Local Regulations. 6. If, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in our design installation must halt & immediate notification be made to Carmen E. Shay - Environmental Services, Inc. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. O \ 8. Install Tuf-Tite gas baffles or equals on all outlet tee ends. 9. All Distribution Lines shall be 4' diameter Schedule 40 NSF PVC pipes. 10. All solid piping, tees & fittings shall be 4" diameter Schedule 40 NSF PVC pipes with water tight joints. 11. Municipal Water is Connected to ALL OF The Residence and Abutting Properties. NOTE: `I EXISTING SAS IS LOCATED IN THE SAME LOCATION AS AS NEW PROPOSED SAS EXISTING SAS TO BE REMOVED. ALL IMPACTED SOIT TO BE REMOVED EXISTING 2 BEDROOM i RANCH HOUSE YarmORt6 Health (FULL FOUNDATION) APPRO #28 (\ h N ame h \ 1 1 w \\ 1 I \ I I - LOT-#399 ------ -= ------- J-------+-------------------99 I 12,600 Square Feet +/- II I ASPHALT DRIVEWAY � I I 105.00' 1 I -------------------------------------------------------<---------- ---------- CAPT. 5TANL-AO Y 0 20 40 50 (40 FOOT RIGHT OF WAY) SCALE: 1 "=20' Date THE PROPERTY LINES ARE APPROXIMATE AND COMPILED FROM THE SURVEY PLAN BY RYDER & WILCOX. ENTITLED: "CERTIFIED PLOT PLAN-28 CAPT. STANLEY RD, S YARMOUTH, MA" FEBRUARY. 13. 2013 AND IS NOT INTENDED TO BE A SURVEY PLOT PLAN IT SHOULD BE USED FOR NO PURPOSE OTHER THAN THE SEPTIC SYSTEM INSTALLATION. EXISTING LEACH SAS TO BE PUMPED OUT AND REMOVED NOTE: ANY STRIPPED OUT SOIL CONTAINING LEACHATE FROM THE EXISTING SAS TO BE DISPOSED OF AS PER BOARD OF HEALTH SPECIFICATIONS. PLOT PLAN OPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR CHERYL KENT AT 28 CAPT. STAN LEY PARCEL ID: 67-160 PREPARED BY: CARMEN 0 E. SM Y ENVIRONMENTAL SERVICES P.O. Box 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 SCAE: 1 "=20- 1 DRAWN BY: CES I DATE: SEPT. 6, 2022 1 PROJECT#28 Capn Stanley I FILENAME: 28Capn Stanley.DWG I SHEET 1 OF w -r 2-1e' DIAM. ACCESS MAM40ES STEEL REINFORCED PRECAST CONCRETE PLAN VIEW 3-24' M10V' &,E COVERS . THE ACCESS COVERS FOR THE SEP11C TANK, DISMINTION 90X AND LEAD" COMPONENT SET DEO" AINCNB 6 GRADE SHAUBERSED TO 1MMW Y OF FINISHED GRADE. INSTALL NN-T11E GAS BAFFLES OR EQUALS IY J}-NEK -y11LT1I(-� s' -T LA1oM depth 1e-o" CROSS SECTION END —SECTION TYPICAL 1500 GALLON SEPTIC TANK . EV"t to what e. uw—R'Tar+r-- OUTLET Design Calculations Number of Bedroo�quivalent to 220 Gal./Ooy (330 Gal./Day per Title V MINIMUM) Garbage Grinder: Septic Tank : — 2 x 330 Gal./Day = 660 USE EXIST. 1,500 GAL. Septic Tank. SOIL ABSORPTION AREA: Using percolation rate of <2 min./inch SOIL ABSORPTION AREA: Using percolation rate of C2 min./inch Proposed Leaching Field Dimensions: 1 O 15' Wide by 30' Long. Bottom Area: 0.74 gal/sq. ft. x 450 sq. ft. =333 gallons Sidewall Area: NOT USED Providing: 333 ollons PERCOLATION TEST Date of Percolation Test: AUGUST 11, 2022 Test Performed By. CARMEN SHAY tesuits Witnessed By. JAY GARDNER—(YARMOUTH BOH) EXCAVATOR:SHAY ENV. SRVCS.. Percolation Rate: Less Than 2 MPI ® 36" Test Hole No. 1 DEPTH SOILS ELEV. 0 98.50 FILL 198.001 0'— 6' Loomy 10 Nt 3/2 6'— 12' h 97.50 L any see 12'-36' to 1R 5/e 95.50 Mod Sand 26 Y 7/4 36'-132' Q 87.50 Perc /1 Depth to Perc:36" to 54' Perc Rate= 2 MPI ASSUMED Groundwater Not Observed No Observed ESHWT ADJUSTED H2O Elev. = None W SWu BE AT LEAST 2 FT. PLAN SECTION 12" —1 � CONMTE Catf,R 3 - S' OUTLET KNOCKOUTS 4' — SCH. 40 Teems %75T CROSS—SECTION • • • - : • : • PLOT PLAN OF PROPOSED SEPTIC SYSTEM UPGRADE PREPARED FOR CHERYL KENT AT 28 CAPT. STAN LEY PARCEL ID: 67-160 SOUTH YARMOUTH. MA I1GiX7MAOX:l3 Y ENVIRONMENTAL SERVICES P.O. Box 1576 MASHPEE, MA 02649 TEL/FAX : 508-294-7498 I SCALE: 1"=20' I DRAWN BY: CES I DATE: SEPT. 6, 2022 1 PROJECT#28 Capin Stanley I I SHEET 2 OF 2