APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK
All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/19/2023
City or Town of: YARMOUTH To the Inspector of Wires:
By this application the undersigned gives notice of his or her intention to perform the electrical work described below.
Location(Street&Number) 76 CAMP ST
Owner or Tenant NUNZIO NAPOLITANO Telephone No.
Owner's Address
Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box)
Purpose of Building Utility Authorization No.
Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work: Installation of solar PV system(29 Panels 10.88 KW DC)(NO ESS)
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil: No.of Total Susp.(Paddle)Fans Transformers KVA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ElNo.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
No.of Switches No.of Gas Burners No.of Detection and
Initiating Devices
No.of Ranges No.of Air Cond. Tons Tot No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
P Totals: Detection/Alerting Devices
Space/Area HeatingLocal ❑ Municipal No.of Dishwashers P KW Connection
0 Other:
No.of Dryers Heating Appliances KW Security Systems:*
No.of Devices or Equivalent
No.of Water KW No.of No.of Ballasts Data Wiring:
Heaters Signs No.of Devices or Equivalent
Telecommunications Wiring:
No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent
OTHER:
Attach additional detail if desired,or as required by the Inspector of Wires.
required bymunicipal policy.)
Estimated Value of Electrical Work: (Whenq p P y'
Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides
proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage
is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ❑ BOND 0 OTHER 0 (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME: Nathan A Ashe
Licensee: Nathan A Ashe Signature LIC.NO.: 21136
(If applicable,enter"exempt"in the license number line.)
Bus.Tel.No.:
Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.:
*Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License:
OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my
signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent.
Owner/Agent Signature Telephone No. I PERMIT FEE: $150.00 I
GL ,�( �
,per Please email permit to eastmapermits@sunrun.com
\ Commonwealth o jcc7Vamachaiel�a �--Official Use—Onnly
p-. _ _ t �LJePartment o` }ire�ervice� Permit No. 0-27 S !6(�J
i !-
I1- Occupancy and Fee Checked
+y ciot=�__
` BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank)
APPLICATION FOR PERMIT TO PERFORM ELECTRI ` = •
All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 C L. r.
(PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 04/13/2023 I
City or Town of: Yarmouth To the Inspector of Wiles APR 18 2023
By this application the undersigned gives notice of his or her intention to perform the electrical work sc ibed below.
Location(Street& Number)76 Camp St BYUILDINC D --
Owner or Tenant Nunzio Napolitano Telephone o. 8-4489-"i r
Owner's Address 76 Camp St Yarmouth MA 02673
Is this permit in conjunction with a building permit? Yes VI No n (Check Appropriate Box)
Purpose of Building Residential Utility Authorization No.
Existing Service 100 Amps / Volts Overhead IV Undgrd No.of Meters 1
New Service Amps / Volts Overhead n Undgrd No.of Meters
Number of Feeders and Ampacity
Location and Nature of Proposed Electrical Work:
Installation of a interconnected, roof mounted, photovoltaic solar.29 solar panels at 10.88 KwDC. NO ESS. NO STRUCTURAL.
Completion of the following table may be waived by the Inspector of Wires.
No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle F Tf Total) ans Trr anosformers KVVAA
No.of Luminaire Outlets No.of Hot Tubs Generators KVA
No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting
grnd. grnd. Battery Units
No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones
oNo.of Switches No.of Gas Burners No. Initiatingon nDete and
Devices
Totallo.of Ranges No.of Air Cond. Tons No.of Alerting Devices
No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained
p Totals: Detection/Alerting Devices
No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other
P Connection_
No.of Dryers Heating Appliances KW Security Systems:*
rY No.of Devices or Equivalent
No.of Water No.of No.of Data Wiring:
Heaters KW Signs Ballasts No.of Devices or Equivalent
No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications NofDeieor Wiring:
Y g No.of Devices Equivalent
OTHER:
Attach additional detail if desired, or as required by the Inspector of Wires.
Estimated Value of Electrical Work: $14311 (When required by municipal policy.)
Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion.
INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless
the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The
undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office.
CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:)
I certify,under the pains and penalties of perjury,that the information on this application is true and complete.
FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al
Licensee: Nathan Ashe Signature LIC.NO.:21136 A�
(If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519
Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978 793-7881
*Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No.
OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally
required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent.
Owner/Agent PERMIT FEE: $
Signature Telephone No.
Please email permit to eastmapermits@sunrun.com
SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES
PAGE# DESCRIPTION •SYSTEM SIZE:10875W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC),
PV-1.0 COVER SHEET
SE SERVICE ENTRANCE •MODULES:(29)VIKRAM SOLAR:VSMDHT.60.375.05 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION
•INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS.
PV-2,0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023.
MP MAIN PANEL •RACKING.RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,
PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023.
PV-3.1 MOUNTING DETAIL •MAIN PANEL REPLACEMENT EXISTING 100 AMP MAIN 0 SUB-PANEL PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY
PV-4,0 - ELECTRICAL WITH NEW 125 AMP MAIN PANEL WITH 100 AMP MAIN GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35.
PV-5.0 SIGNAGE BREAKER.
LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.
•INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741.
SM SUNRUN METER
•RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.
PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II
MODULES,ARE CLASS A FIRE RATED.
INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL
CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1).
[AC] AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G).
DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT.
O DC DISCONNECT(S)
•12.82 AMPS MODULE SHORT CIRCUIT CURRENT.
Cr) IQ COMBINER BOX •20.03 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)].
•PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2).
ABBREVIATIONS E 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE
A AMPERE _J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION
AC ALTERNATING CURRENT
AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY S u n ru n
AZIM AZIMUTH
COMP COMPOSITION
DC DIRECT CURRENT ATTIC VENT #180120
(El EXISTING FLUSH ATTIC VENT VICINITY MAP
ESS ENERGY STORAGE SYSTEM PVC PIPE VENT RHONELES6TANDISM eLw,TAlIMO1J,Mg 01150.7331
PHONE
F.0
EXT EXTERIOR METAL PIPE VENT ] CUSTOMER RESIDENCE:
INT INTERIOR NUNZIO NAPOLITANO
T-VENT
MSP MAIN SERVICE PANEL 76 CAMP ST,YARMOUTH,MA,
(N) NEW SATELLITE DISH . 02673
NTS NOT TO SCALE zr DoubleT.e+•
oc ON CENTER 76 Camp St,West TEL.(508)498-4489
/ by.Hihon t�.
FIRE SETBACKS Cap' Yarmouth,MA 02673, APN:YARM-000045-000021
PRE-FAB PRE-FABRICATED United States PROJECT NUMBER:
PSF POUNDS PER SQUARE FOOT HARDSCAPE
PV PHOTOVOLTAIC Hampton 11111 223R-076NAP0
SCALE:NTS :.IPt a+nn." 0 8 Surt«. c.+n,
RSO RAPID SHUTDOWN DEVICE PL— PROPERTY LINE `4 4 GT ay HouseC&Su u DESIGNER: (415)580-6920 ex3
TL TRANSFORMERLESS (( -- SOLAR MODULES
SAMEER SHAKUR
1� __ ' a ® SHEET
TYP TYPICAL
7 Hyannis REV NAME DATE COMMENTS COVER SHEET
V VOLTS
W WATTS REV:A 4/12/2023
,
LAN LANDSCAPE -SNR MOUNT e'
POR PORTRAIT '-_. SNR MOUNT&SKIRT PAGE PV-1.0
Templafe_ve 0 4.0.87
LDE 23 na s'7 e 6
SITE PLAN-SCALE=3/64"=1'-0"
?� (N)ARRAY AR-04- PL
(N)ARRAY AR-05 _s— PL
(N)ARRAY AR-01 ,
(E)RESIDENCE -- -�— pt.
0. (E)DETACHED
C //rT "I, I k
STRUCTURE
4
t "
OINV 0(AC
(N)ARRAY AR-02--
(N)ARRAY Y AR-03—
�" ••. "• • F
f 1
sunrun.
#180120
MYLES STAN t.9,0 TAUNTON MA 027804.1
PHONE F.0
CUSTOMER RESIDENCE:
NUNZIO NAPOLITANO
76 CAMP ST,YARMOUTH,MA,
02673
/ PL
et
TRUE MAG PV AREA TEL.(508)498-4489
PITCH AZIM AZIM (SOFT) APN:YARM-000045-000021
PROJECT NUMBER:
AR-01 26° 1° 15° 219.6
a. 223R-076NAP0
AR-02 26° 181° 195° 199.E DESIGNER: (415)580-6920 ex3
P. AR-03 10° 181° 195° 59.9 SAMEER SHAKUR
AR-04 10° 91° 105° 59.9
SHEET
Pt- AR-05 12° 361° 375° 39.9 SITE PLAN
/
REV:A 4/12/2023
PAGE PV-2.O
Tampere version 4.0.87
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Name Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait
9 Detail OC Spacing Overhang OC Spacing Overhang Configuration
Span Spacing
AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 10'-9" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 2'-0" STAGGERED
COMP,SEE DETAIL SNR-DC-00436
AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-6" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 6'-0" 1 2'-4" 4'-0" 2'-0" STAGGERED
DETAIL SNR-DC-00436
AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-0" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 1'-6" STAGGERED
DETAIL SNR-DC-00436
D1-AR-01-SCALE:3/16"=1'-0"
AZIM:1° 1'-10",f— 23.-4" 1-
PITCH:26°
= _ III__ nom
--
STRUCT
ONL 4* iH OF M4SS4\
6'-11" = = - - - if VINCENT y6vf„
• S MWUMVANEZA N
10'-6" CIVIL
• • • � — — .7. �����/ONA EN���4,
IN
SIGNED 04/12/2023
11"
D2- -SCALE:116"=1'-0" D3- -SCALE:1/8"=1'-0" s u n r u n
AZIM:
181 181° AZIM:
181 181°
PITCH:26° PITCH:10°
11"-I 23,-4" -3' } 5-10" #180120
VA"- 2'-3"
t. —__,
1'.9" I eoe uv�e eruae wti e� ,rNx+ron,MA,mnn3ar
ROSE
na
3.-6" e,axo
3S i iii, 7' CUSTOMER RESIDENCE:
nal
2 � 10-0" 3'-6" 76 CAMP ST,oARMOUTH.MA,
MIN= 3'
5 I
TEL.(508)498-4469
1�' 2. _...-.y.__-__.__.1 t'$,� _ _ ..-kk 11 APN:YARM-000045-000021
PROJECT NUMBER:
{ 4'B 1T 6" h1'6" 6� 223R-076NAP0
_SEE SITE PLAN FOR NORTH ARROW DESIGNER: (415)580-6920 ex3
DESIGN CRITERIA STRUCTURAL NOTES *IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE SAMEER SHAKUR
MAX DISTRIBUTED LOAD:3 PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG
SNOW LOAD:30 PSF POTENTIAL STRUCTURAL ISSUES OBSERVED SHEET
PRIOR TO PROCEEDING W/INSTALLATION. REDUCEDLLOWITHIN THE 12"BOUNDARY INDICANTED
ED ONLY AS PLANS TO BE
LAYOUT
WIND SPEED: "ALLOWABLE ATTACHMENT SPACING INDICATED ON TO BE REDUCED BY 50%.
140 MPH 3-SEC GUST. "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE
S.S.LAG SCREW ATTACHMENT SPACING INDICATED ON PLANS. REV:A 4/12/2023
5/16":2.5"MIN.EMBEDMENT PAGE PV-3.0
rempare_vmson_a.0.87
ROOF INFO FRAMING INFO ATTACHMENT INFORMATION
Max OC Max Landscape Max Landscape Max Portrait Max Portrait
Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration
AR-04 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-2" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 1'-6" STAGGERED
DETAIL SNR-DC-00436
AR-05 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE DETAIL '-4" 2'-1" 1'-7" STAGGERED
SNR-DC-00436
D4-AR-04-SCALE:1/8"=1'-0"
AZIM:91° —3'—,-2'-9"-
PITCH:10° 5'-10"
STRUCT ,,,
_ _ ONL
r* c0ytR OF M,,SS9
F�� VINCENT ',
_ 2 _ _ r. g MWUMVANEZA y
CIVIL
• • • 41 ��' 10NAlEHC''
1'
SIGNED 04/12/2023
Jr 5'-10" 11'-6" — —5'-11" #
D5-AR-05-SCALE:1/8"=1'-0"
A21M:361° 8"-{ 5'-10" 2'-2"t- s u n r u n
PITCH:12°
V-10"
#180120
# ES STgNDISH B .TNUMPV.MA 0])90.I3J1
505 MALES
l W
NE
FAX e 6'-11"
CUSTOMER RESIDENCE:
NUNZIO NAPOLITANO
76 CAMP ST,YARMOUTH,MA,
„ Ell. ____ 02673
3'-3" TEL.(508)498-4489
APN:YARM-000045-000021
PROJECT NUMBER:
SEE SITE PLAN FOR NORTH ARROW 12'IIM
223R-076NAPO
t - DESIGNER: (415)580-6920 ex3
DESIGN CRITERIA STRUCTURAL NOTES •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE SAMEER SHAKUR
MAX DISTRIBUTED LOAD:3 PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG
SNOW LOAD:30 PSF POTENTIAL STRUCTURAL ISSUES OBSERVED REDUCED WITHIN THE 12"BOUNDARY REGION ONLY AS FOLLOWS: SHEET
WIND SPEED: PRIOR TO PROCEEDING W/INSTALLATION. -ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. MOUNTING DETAIL
140 MPH 3-SEC GUST. ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE
S.S.LAG SCREW ATTACHMENT SPACING INDICATED ON PLANS. REV:A 4/12/2023
5/16":2.5"MIN.EMBEDMENT
PAGE PV-3.1
remp.re_ve n 4.0.87
120/240 VAC
SINGLE PHASE
SERVICE NOTE:TOTAL PV BACKFEED=40A
METER#: USED FOR INTERCONNECTION
< ® EVERSOURCE 1952234 CALCULATIONS
UTILITY
GRID I
SUPPLY SIDE TAP
c_-'0
C I NEW 100A (N)LOCKABLE
BLADE TYPE (N)MA SMART
MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES:
1 DISCONNECT METERUE SE7800H-USSN
7600 WATT INVERTER JUNCTION BOX PV MODULES
�\ (y� (� 9 OR EQUIVALENT 9 VIKRAM SOLAR:VSMDHT.60.375.05
NEW 125A 9 9
�- MAIN PANEL O f — ---r— + / P)MODULES
< o�.o. M N I OPTIMIZERS WIRED IN:
FACILITY (1)SERIES OF(15)OPTIMIZERS
40A FUSES --I I (1)SERIES OF(14)OPTIMIZERS
LOADS LDoDn SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT
D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS
3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440
120/240VAC CONNECTS TO TOP LUGS-
(UNE AT TOP LOAD AT BOTTOM)
CONDUIT SCHEDULE
# CONDUIT CONDUCTOR NEUTRAL GROUND
1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER
2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/fHWN-2 s u n r u n
3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2
#180120
WSS MYLES STANDISH BLVD,TAUNTON.MA.02780.7331
PHONE 0
FAX 0
CUSTOMER RESIDENCE:
MODULE CHARACTERISTICS NUNZIO NAPOLITANO
VIKRAM SOLAR:VSMDHT.60.375.05: 375 W S440 OPTIMIZER CHARACTERISTICS: 76 CAMP ST,YARMOUTH,MA,
OPEN CIRCUIT VOLTAGE: 41.1 V MIN INPUT VOLTAGE: 8 VDC 02673
MAX POWER VOLTAGE: 34.9 V MAX INPUT VOLTAGE: 60 VDC
SHORT CIRCUIT CURRENT: 12.82 A MAX INPUT ISC: 14.5 ADC TEL.(508)498.4489
MAX OUTPUT CURRENT: 15 ADC APN:YARM-000045-000021
PROJECT NUMBER:
SYSTEM CHARACTERISTICS-INVERTER 1 223R-076NAPO
SYSTEM SIZE: 10875 W
SYSTEM OPEN CIRCUIT VOLTAGE: 15 V DESIGNER: (415)580-6920 ex3
SYSTEM OPERATING VOLTAGE: 400 V SAMEER SHAKUR
MAX ALLOWABLE DC VOLTAGE: 480 V
SYSTEM OPERATING CURRENT: 27.19 A SHEET
SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL
REV:A 4/12/2023
PAGE PV-4.0
T mpers_e rsion 4.0.87
AWARNING INVERTER 1 NOTES AND SPECIFICATIONS:
.
•SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE
ELECTRICAL SHOCK HAZARD OVOLTAIC DC NNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR
-"-- -- -- IF REQUESTED BY THE LOCAL AHJ.
480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE
TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS.
SIDES MAY BE ENERGIZED IN - •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING
THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN.
INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT
PER CODE(S):NEC 2023:690.7(D) INVOLVED.
LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY
INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED.
AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS.
PER CODE(S):NEC 2023:690.13(B),
705.20(7),706.15(C)
AWARNING WARNING: PHOTOVOLTAIC
DUAL POWER SUPPLY LIE, POWER SOURCE
SOURCES:UTILITY GRID LABEL LOCATION:
AND PV SOLAR ELECTRIC INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT,
AT EACH TURN,ABOVE AND BELOW PENETRATIONS, -
SYSTEM ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS.
PER CODE(S):NEC 2023:690.31(D)(2)
LABEL LOCATION:
UTIUTY SERVICE METER AND MAIN CAUTION :SERVICE PANEL.PER CODE(S):NEC 2023:705.30(C)
WARNING RAPIDSHUTDOWNSWITCH MULTIPLE SOURCES OF POWER
POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM
DO NOT RELOCATE THIS I /\
OVERCURRENT DEVICE N/ 1N1
, LABEL LOCATION: \_
LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN
ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(D)(2),IFC s u n r u n
OCPD(IF APPLICABLE). 2018:1204.5.3
PER CODE(S):NEC 2023:705.12(6)(2) ❑ -
4„ ,
i
A WARNING SOLAR PV SYSTEM EQUIPPED #180120
THIS EQUIPMENT FED BY — 1 fiBS MYLES STANDISH BLVD,TAUNTON,MA,m7Bo-7331
MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN Axa
RATING OF ALL OVERCURRENT
DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE:
SUPPLY OVERCURRENT DEVICE NUNZIO NAPOLITANO
SHALL NOT EXCEED AMPACITY OF / I } —SOLAR PANELS ON ROOF 76 CAMP ST,YARMOUTH,MA,
BUSBAR L 02673
LABEL LOCATION: 3 TURN RAPID SHUTDOWN INVERTER (EXT)
PV LOAD CENTER(IF APPUCABLE)AND SWITCH TO THE"OFF' ov ParE�s- MAIN TEL.(508)498-4489
ANY -PRODUCTION METER
OFBREAEL THATS LEIUZES"THE SUM POSITION TO SHUT DOWN PANEL(INT) APN:YARM-000045-000021
PER CODE(S):NEC 2023:705.12(8)(3) PV SYSTEM AND REDUCE —FUSED AC DISCONNECT PROJECT NUMBER:
SHOCK HAZARD INTHE -SERVICE ENTRANCE
ARRAY.INEW
223R-076NAPO
...-. .- -- DESIGNER: (415)580-8920 ex3
MAXIMUM ACOPFRATINGCURRFNT 32.O0AMPS 76 CAMP ST, YARMOUTH, MA, 02673 SAMEERSHAKUR
NOMINAL OPERATING AC VOLTAGE. 240 VAC 1 ` , SHEET
LABEL LOCATION: PER CODE(S):NEC 2023 705.10(2) SIGNAGE
LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE
AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS
INTERCONNECTION. ARE CONNECTED. REV A 4/12/2023
PER CODE(S):NEC 2023:690.54 PER CODE(S):NEC 2023:690.12(D)
PAGE PV-5.0
Template_ve n_40.87