Loading...
HomeMy WebLinkAboutBLDE-23-005786 Commonwealth of Official Use Only ' Mk Massachusetts Permit No. BLDE-23-005786 BOARD OF FIRE PREVENTION REGULATIONS Occupancy and Fee Checked [Rev.1/07] APPLICATION FOR PERMIT TO PERFORM ELECTRICAL WORK All work to be performed in accordance with the Massachusetts Electrical Code (MEC),527 CMR 12.00 (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date:4/19/2023 City or Town of: YARMOUTH To the Inspector of Wires: By this application the undersigned gives notice of his or her intention to perform the electrical work described below. Location(Street&Number) 76 CAMP ST Owner or Tenant NUNZIO NAPOLITANO Telephone No. Owner's Address Is this permit in conjunction with a building permit? Yes 0 No 0 (Check Appropriate Box) Purpose of Building Utility Authorization No. Existing Service Amps Volts Overhead 0 Undgrd 0 No.of Meters New Service Amps Volts Overhead 0 Undgrd 0 No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of solar PV system(29 Panels 10.88 KW DC)(NO ESS) Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil: No.of Total Susp.(Paddle)Fans Transformers KVA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ElNo.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones No.of Switches No.of Gas Burners No.of Detection and Initiating Devices No.of Ranges No.of Air Cond. Tons Tot No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained P Totals: Detection/Alerting Devices Space/Area HeatingLocal ❑ Municipal No.of Dishwashers P KW Connection 0 Other: No.of Dryers Heating Appliances KW Security Systems:* No.of Devices or Equivalent No.of Water KW No.of No.of Ballasts Data Wiring: Heaters Signs No.of Devices or Equivalent Telecommunications Wiring: No.Hydromassage Bathtubs No.of Motors Total HP No.of Devices or Equivalent OTHER: Attach additional detail if desired,or as required by the Inspector of Wires. required bymunicipal policy.) Estimated Value of Electrical Work: (Whenq p P y' Work to start: Inspection to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE:Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent.The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ❑ BOND 0 OTHER 0 (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME: Nathan A Ashe Licensee: Nathan A Ashe Signature LIC.NO.: 21136 (If applicable,enter"exempt"in the license number line.) Bus.Tel.No.: Address: 166 Hunt Rd, Chelmsford MA 018243747 Alt.Tel.No.: *Per M.G.L.c. 147,s.57-61,security work requires Department of Public Safety"S"License: OWNER'S INSURANCE WAIVER:I am aware that the License does not have the liability insurance coverage normally required by law.But my signature below,I hereby waive this requirement.I am the(check one) 0 owner 0 owner's agent. Owner/Agent Signature Telephone No. I PERMIT FEE: $150.00 I GL ,�( � ,per Please email permit to eastmapermits@sunrun.com \ Commonwealth o jcc7Vamachaiel�a �--Official Use—Onnly p-. _ _ t �LJePartment o` }ire�ervice� Permit No. 0-27 S !6(�J i !- I1- Occupancy and Fee Checked +y ciot=�__ ` BOARD OF FIRE PREVENTION REGULATIONS [Rev. 1/07] (leave blank) APPLICATION FOR PERMIT TO PERFORM ELECTRI ` = • All work to be performed in accordance with the Massachusetts Electrical Code(MEC),527 C L. r. (PLEASE PRINT IN INK OR TYPE ALL INFORMATION) Date: 04/13/2023 I City or Town of: Yarmouth To the Inspector of Wiles APR 18 2023 By this application the undersigned gives notice of his or her intention to perform the electrical work sc ibed below. Location(Street& Number)76 Camp St BYUILDINC D -- Owner or Tenant Nunzio Napolitano Telephone o. 8-4489-"i r Owner's Address 76 Camp St Yarmouth MA 02673 Is this permit in conjunction with a building permit? Yes VI No n (Check Appropriate Box) Purpose of Building Residential Utility Authorization No. Existing Service 100 Amps / Volts Overhead IV Undgrd No.of Meters 1 New Service Amps / Volts Overhead n Undgrd No.of Meters Number of Feeders and Ampacity Location and Nature of Proposed Electrical Work: Installation of a interconnected, roof mounted, photovoltaic solar.29 solar panels at 10.88 KwDC. NO ESS. NO STRUCTURAL. Completion of the following table may be waived by the Inspector of Wires. No.of Recessed Luminaires No.of Ceil.-Susp.(Paddle F Tf Total) ans Trr anosformers KVVAA No.of Luminaire Outlets No.of Hot Tubs Generators KVA No.of Luminaires Swimming Pool Above ❑ In- ❑ No.of Emergency Lighting grnd. grnd. Battery Units No.of Receptacle Outlets No.of Oil Burners FIRE ALARMS No.of Zones oNo.of Switches No.of Gas Burners No. Initiatingon nDete and Devices Totallo.of Ranges No.of Air Cond. Tons No.of Alerting Devices No.of Waste Disposers Heat Pump Number Tons KW No.of Self-Contained p Totals: Detection/Alerting Devices No.of Dishwashers Space/Area HeatingKW Local❑ Municipal ❑ Other P Connection_ No.of Dryers Heating Appliances KW Security Systems:* rY No.of Devices or Equivalent No.of Water No.of No.of Data Wiring: Heaters KW Signs Ballasts No.of Devices or Equivalent No.H dromassa a Bathtubs No.of Motors Total HP Telecommunications NofDeieor Wiring: Y g No.of Devices Equivalent OTHER: Attach additional detail if desired, or as required by the Inspector of Wires. Estimated Value of Electrical Work: $14311 (When required by municipal policy.) Work to Start:ASAP Inspections to be requested in accordance with MEC Rule 10,and upon completion. INSURANCE COVERAGE: Unless waived by the owner,no permit for the performance of electrical work may issue unless the licensee provides proof of liability insurance including"completed operation"coverage or its substantial equivalent. The undersigned certifies that such coverage is in force,and has exhibited proof of same to the permit issuing office. CHECK ONE: INSURANCE ® BOND ❑ OTHER ❑ (Specify:) I certify,under the pains and penalties of perjury,that the information on this application is true and complete. FIRM NAME:Sunrun Installation Services Inc. LIC.NO.: 4316 Al Licensee: Nathan Ashe Signature LIC.NO.:21136 A� (If applicable,enter "exempt"in the license number line.) Bus.Tel.No.:978 594-3519 Address: 695 Myles Standish Blvd. Taunton, MA 02780 Alt.Tel.No.: 978 793-7881 *Per M.G.L.c. 147,s. 57-61,security work requires Department of Public Safety"S"License: Lic.No. OWNER'S INSURANCE WAIVER: I am aware that the Licensee does not have the liability insurance coverage normally required by law. By my signature below,I hereby waive this requirement. I am the(check one)❑owner ❑owner's agent. Owner/Agent PERMIT FEE: $ Signature Telephone No. Please email permit to eastmapermits@sunrun.com SHEET INDEX LEGEND SCOPE OF WORK GENERAL NOTES PAGE# DESCRIPTION •SYSTEM SIZE:10875W DC,7600W AC •ALL WORK SHALL COMPLY WITH MA 9TH ED.CMR 780(2015 IRC/IBC/IEBC), PV-1.0 COVER SHEET SE SERVICE ENTRANCE •MODULES:(29)VIKRAM SOLAR:VSMDHT.60.375.05 MUNICIPAL CODE,AND ALL MANUFACTURERS'LISTINGS AND INSTALLATION •INVERTERS:(1)SOLAREDGE TECHNOLOGIES: INSTRUCTIONS. PV-2,0 SITE PLAN SE7600H-USSN •PHOTOVOLTAIC SYSTEM WILL COMPLY WITH NEC 2023. MP MAIN PANEL •RACKING.RL UNIVERSAL,SPEEDSEAL TRACK ON COMP, PV-3.0 LAYOUT SEE DETAIL SNR-DC-00436 •ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH NEC 2023. PV-3.1 MOUNTING DETAIL •MAIN PANEL REPLACEMENT EXISTING 100 AMP MAIN 0 SUB-PANEL PANEL WITH 100 AMP MAIN BREAKER TO BE REPLACED •PHOTOVOLTAIC SYSTEM IS UNGROUNDED.NO CONDUCTORS ARE SOLIDLY PV-4,0 - ELECTRICAL WITH NEW 125 AMP MAIN PANEL WITH 100 AMP MAIN GROUNDED IN THE INVERTER.SYSTEM COMPLIES WITH 690.35. PV-5.0 SIGNAGE BREAKER. LC PV LOAD CENTER •MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. •INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741. SM SUNRUN METER •RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. PM PRODUCTION METER •SNAPNRACK RACKING SYSTEMS,IN COMBINATION WITH TYPE I,OR TYPE II MODULES,ARE CLASS A FIRE RATED. INV INVERTER(S) •RAPID SHUTDOWN REQUIREMENTS MET WHEN INVERTERS AND ALL CONDUCTORS ARE WITHIN ARRAY BOUNDARIES PER NEC 690.12(1). [AC] AC DISCONNECT(S) •CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31(G). DC •ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. O DC DISCONNECT(S) •12.82 AMPS MODULE SHORT CIRCUIT CURRENT. Cr) IQ COMBINER BOX •20.03 AMPS DERATED SHORT CIRCUIT CURRENT[690.8(A)&690.8(B)]. •PV INSTALLATION COMPLIES WITH THE NEC 2023 ARTICLE 690.12(B)(2)(2). ABBREVIATIONS E 7 INTERIOR EQUIPMENT CONTROLLED CONDUCTORS LOCATED INSIDE THE ARRAY BOUNDARY ARE A AMPERE _J SHOWN AS DASHED LIMITED TO 80 VOLTS WITHIN 30 SECOND OF A RAPID SHUTDOWN INITIATION AC ALTERNATING CURRENT AFC ARC FAULT CIRCUIT INTERUPTER CHIMNEY S u n ru n AZIM AZIMUTH COMP COMPOSITION DC DIRECT CURRENT ATTIC VENT #180120 (El EXISTING FLUSH ATTIC VENT VICINITY MAP ESS ENERGY STORAGE SYSTEM PVC PIPE VENT RHONELES6TANDISM eLw,TAlIMO1J,Mg 01150.7331 PHONE F.0 EXT EXTERIOR METAL PIPE VENT ] CUSTOMER RESIDENCE: INT INTERIOR NUNZIO NAPOLITANO T-VENT MSP MAIN SERVICE PANEL 76 CAMP ST,YARMOUTH,MA, (N) NEW SATELLITE DISH . 02673 NTS NOT TO SCALE zr DoubleT.e+• oc ON CENTER 76 Camp St,West TEL.(508)498-4489 / by.Hihon t�. FIRE SETBACKS Cap' Yarmouth,MA 02673, APN:YARM-000045-000021 PRE-FAB PRE-FABRICATED United States PROJECT NUMBER: PSF POUNDS PER SQUARE FOOT HARDSCAPE PV PHOTOVOLTAIC Hampton 11111 223R-076NAP0 SCALE:NTS :.IPt a+nn." 0 8 Surt«. c.+n, RSO RAPID SHUTDOWN DEVICE PL— PROPERTY LINE `4 4 GT ay HouseC&Su u DESIGNER: (415)580-6920 ex3 TL TRANSFORMERLESS (( -- SOLAR MODULES SAMEER SHAKUR 1� __ ' a ® SHEET TYP TYPICAL 7 Hyannis REV NAME DATE COMMENTS COVER SHEET V VOLTS W WATTS REV:A 4/12/2023 , LAN LANDSCAPE -SNR MOUNT e' POR PORTRAIT '-_. SNR MOUNT&SKIRT PAGE PV-1.0 Templafe_ve 0 4.0.87 LDE 23 na s'7 e 6 SITE PLAN-SCALE=3/64"=1'-0" ?� (N)ARRAY AR-04- PL (N)ARRAY AR-05 _s— PL (N)ARRAY AR-01 , (E)RESIDENCE -- -�— pt. 0. (E)DETACHED C //rT "I, I k STRUCTURE 4 t " OINV 0(AC (N)ARRAY AR-02-- (N)ARRAY Y AR-03— �" ••. "• • F f 1 sunrun. #180120 MYLES STAN t.9,0 TAUNTON MA 027804.1 PHONE F.0 CUSTOMER RESIDENCE: NUNZIO NAPOLITANO 76 CAMP ST,YARMOUTH,MA, 02673 / PL et TRUE MAG PV AREA TEL.(508)498-4489 PITCH AZIM AZIM (SOFT) APN:YARM-000045-000021 PROJECT NUMBER: AR-01 26° 1° 15° 219.6 a. 223R-076NAP0 AR-02 26° 181° 195° 199.E DESIGNER: (415)580-6920 ex3 P. AR-03 10° 181° 195° 59.9 SAMEER SHAKUR AR-04 10° 91° 105° 59.9 SHEET Pt- AR-05 12° 361° 375° 39.9 SITE PLAN / REV:A 4/12/2023 PAGE PV-2.O Tampere version 4.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Name Type Height TypeMax OC Max Landscape Max Landscape Max Portrait Max Portrait 9 Detail OC Spacing Overhang OC Spacing Overhang Configuration Span Spacing AR-01 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 10'-9" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON 2'-0" STAGGERED COMP,SEE DETAIL SNR-DC-00436 AR-02 COMP SHINGLE-RLU 2-Story 2X6 RAFTERS 11'-6" 24" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 6'-0" 1 2'-4" 4'-0" 2'-0" STAGGERED DETAIL SNR-DC-00436 AR-03 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-0" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 1'-6" STAGGERED DETAIL SNR-DC-00436 D1-AR-01-SCALE:3/16"=1'-0" AZIM:1° 1'-10",f— 23.-4" 1- PITCH:26° = _ III__ nom -- STRUCT ONL 4* iH OF M4SS4\ 6'-11" = = - - - if VINCENT y6vf„ • S MWUMVANEZA N 10'-6" CIVIL • • • � — — .7. �����/ONA EN���4, IN SIGNED 04/12/2023 11" D2- -SCALE:116"=1'-0" D3- -SCALE:1/8"=1'-0" s u n r u n AZIM: 181 181° AZIM: 181 181° PITCH:26° PITCH:10° 11"-I 23,-4" -3' } 5-10" #180120 VA"- 2'-3" t. —__, 1'.9" I eoe uv�e eruae wti e� ,rNx+ron,MA,mnn3ar ROSE na 3.-6" e,axo 3S i iii, 7' CUSTOMER RESIDENCE: nal 2 � 10-0" 3'-6" 76 CAMP ST,oARMOUTH.MA, MIN= 3' 5 I TEL.(508)498-4469 1�' 2. _...-.y.__-__.__.1 t'$,� _ _ ..-kk 11 APN:YARM-000045-000021 PROJECT NUMBER: { 4'B 1T 6" h1'6" 6� 223R-076NAP0 _SEE SITE PLAN FOR NORTH ARROW DESIGNER: (415)580-6920 ex3 DESIGN CRITERIA STRUCTURAL NOTES *IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE SAMEER SHAKUR MAX DISTRIBUTED LOAD:3 PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG SNOW LOAD:30 PSF POTENTIAL STRUCTURAL ISSUES OBSERVED SHEET PRIOR TO PROCEEDING W/INSTALLATION. REDUCEDLLOWITHIN THE 12"BOUNDARY INDICANTED ED ONLY AS PLANS TO BE LAYOUT WIND SPEED: "ALLOWABLE ATTACHMENT SPACING INDICATED ON TO BE REDUCED BY 50%. 140 MPH 3-SEC GUST. "ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE S.S.LAG SCREW ATTACHMENT SPACING INDICATED ON PLANS. REV:A 4/12/2023 5/16":2.5"MIN.EMBEDMENT PAGE PV-3.0 rempare_vmson_a.0.87 ROOF INFO FRAMING INFO ATTACHMENT INFORMATION Max OC Max Landscape Max Landscape Max Portrait Max Portrait Name Type Height Type Span Spacing Detail OC Spacing Overhang OC Spacing Overhang Configuration AR-04 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 11'-2" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE 5'-4" 1'-6" STAGGERED DETAIL SNR-DC-00436 AR-05 COMP SHINGLE-RLU 1-Story 2X6 RAFTERS 10'-5" 16" RL UNIVERSAL,SPEEDSEAL TRACK ON COMP,SEE DETAIL '-4" 2'-1" 1'-7" STAGGERED SNR-DC-00436 D4-AR-04-SCALE:1/8"=1'-0" AZIM:91° —3'—,-2'-9"- PITCH:10° 5'-10" STRUCT ,,, _ _ ONL r* c0ytR OF M,,SS9 F�� VINCENT ', _ 2 _ _ r. g MWUMVANEZA y CIVIL • • • 41 ��' 10NAlEHC'' 1' SIGNED 04/12/2023 Jr 5'-10" 11'-6" — —5'-11" # D5-AR-05-SCALE:1/8"=1'-0" A21M:361° 8"-{ 5'-10" 2'-2"t- s u n r u n PITCH:12° V-10" #180120 # ES STgNDISH B .TNUMPV.MA 0])90.I3J1 505 MALES l W NE FAX e 6'-11" CUSTOMER RESIDENCE: NUNZIO NAPOLITANO 76 CAMP ST,YARMOUTH,MA, „ Ell. ____ 02673 3'-3" TEL.(508)498-4489 APN:YARM-000045-000021 PROJECT NUMBER: SEE SITE PLAN FOR NORTH ARROW 12'IIM 223R-076NAPO t - DESIGNER: (415)580-6920 ex3 DESIGN CRITERIA STRUCTURAL NOTES •IF ARRAY(EXCLUDING SKIRT)IS WITHIN 12"BOUNDARY REGION OF ANY ROOF PLANE SAMEER SHAKUR MAX DISTRIBUTED LOAD:3 PSF INSTALLERS SHALL NOTIFY ENGINEER OF ANY EDGES(EXCEPT VALLEYS),THEN ATTACHMENTS NEED TO BE ADDED AND OVERHANG SNOW LOAD:30 PSF POTENTIAL STRUCTURAL ISSUES OBSERVED REDUCED WITHIN THE 12"BOUNDARY REGION ONLY AS FOLLOWS: SHEET WIND SPEED: PRIOR TO PROCEEDING W/INSTALLATION. -ALLOWABLE ATTACHMENT SPACING INDICATED ON PLANS TO BE REDUCED BY 50%. MOUNTING DETAIL 140 MPH 3-SEC GUST. ••ALLOWABLE OVERHANG INDICATED ON PLANS TO BE 1/5TH OF ALLOWABLE S.S.LAG SCREW ATTACHMENT SPACING INDICATED ON PLANS. REV:A 4/12/2023 5/16":2.5"MIN.EMBEDMENT PAGE PV-3.1 remp.re_ve n 4.0.87 120/240 VAC SINGLE PHASE SERVICE NOTE:TOTAL PV BACKFEED=40A METER#: USED FOR INTERCONNECTION < ® EVERSOURCE 1952234 CALCULATIONS UTILITY GRID I SUPPLY SIDE TAP c_-'0 C I NEW 100A (N)LOCKABLE BLADE TYPE (N)MA SMART MAIN BREAKER FUSED AC UTILITY SOLAREDGE TECHNOLOGIES: 1 DISCONNECT METERUE SE7800H-USSN 7600 WATT INVERTER JUNCTION BOX PV MODULES �\ (y� (� 9 OR EQUIVALENT 9 VIKRAM SOLAR:VSMDHT.60.375.05 NEW 125A 9 9 �- MAIN PANEL O f — ---r— + / P)MODULES < o�.o. M N I OPTIMIZERS WIRED IN: FACILITY (1)SERIES OF(15)OPTIMIZERS 40A FUSES --I I (1)SERIES OF(14)OPTIMIZERS LOADS LDoDn SQUARE D 240V METER SOCKET LOAD RATED DC DISCONNECT D222NRB 100A CONTINUOUS WITH AFCI,RAPID SHUTDOWN L SOLAREDGE POWER OPTIMIZERS 3R,60A UTILITY SIDE OF CIRCUIT COMPLIANT S440 120/240VAC CONNECTS TO TOP LUGS- (UNE AT TOP LOAD AT BOTTOM) CONDUIT SCHEDULE # CONDUIT CONDUCTOR NEUTRAL GROUND 1 NONE (4)10 AWG PV WIRE NONE (1)10 AWG BARE COPPER 2 3/4"EMT OR EQUIV. (4)10 AWG THHN/THWN-2 NONE (1)10 AWG THHN/fHWN-2 s u n r u n 3 3/4"EMT OR EQUIV. (2)8 AWG THHN/THWN-2 (1)10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 4 3/4"EMT OR EQUIV. (2)6 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 #180120 WSS MYLES STANDISH BLVD,TAUNTON.MA.02780.7331 PHONE 0 FAX 0 CUSTOMER RESIDENCE: MODULE CHARACTERISTICS NUNZIO NAPOLITANO VIKRAM SOLAR:VSMDHT.60.375.05: 375 W S440 OPTIMIZER CHARACTERISTICS: 76 CAMP ST,YARMOUTH,MA, OPEN CIRCUIT VOLTAGE: 41.1 V MIN INPUT VOLTAGE: 8 VDC 02673 MAX POWER VOLTAGE: 34.9 V MAX INPUT VOLTAGE: 60 VDC SHORT CIRCUIT CURRENT: 12.82 A MAX INPUT ISC: 14.5 ADC TEL.(508)498.4489 MAX OUTPUT CURRENT: 15 ADC APN:YARM-000045-000021 PROJECT NUMBER: SYSTEM CHARACTERISTICS-INVERTER 1 223R-076NAPO SYSTEM SIZE: 10875 W SYSTEM OPEN CIRCUIT VOLTAGE: 15 V DESIGNER: (415)580-6920 ex3 SYSTEM OPERATING VOLTAGE: 400 V SAMEER SHAKUR MAX ALLOWABLE DC VOLTAGE: 480 V SYSTEM OPERATING CURRENT: 27.19 A SHEET SYSTEM SHORT CIRCUIT CURRENT: 30 A ELECTRICAL REV:A 4/12/2023 PAGE PV-4.0 T mpers_e rsion 4.0.87 AWARNING INVERTER 1 NOTES AND SPECIFICATIONS: . •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2023 ARTICLE ELECTRICAL SHOCK HAZARD OVOLTAIC DC NNECT 110.21(B),UNLESS SPECIFIC INSTRUCTIONS ARE REQUIRED BY SECTION 690,OR -"-- -- -- IF REQUESTED BY THE LOCAL AHJ. 480 VDC •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USING EFFECTIVE TERMINALS ON LINE AND LOAD WORDS,COLORS AND SYMBOLS. SIDES MAY BE ENERGIZED IN - •LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT OR WIRING THE OPEN POSITION LABEL LOCATION: METHOD AND SHALL NOT BE HAND WRITTEN. INVERTER(S),DC DISCONNECT(S). •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT PER CODE(S):NEC 2023:690.7(D) INVOLVED. LABEL LOCATION: •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011,PRODUCT SAFETY INVERTER(S),AC/DC DISCONNECT(S), SIGNS AND LABELS,UNLESS OTHERWISE SPECIFIED. AC COMBINER PANEL(IF APPLICABLE). •DO NOT COVER EXISTING MANUFACTURER LABELS. PER CODE(S):NEC 2023:690.13(B), 705.20(7),706.15(C) AWARNING WARNING: PHOTOVOLTAIC DUAL POWER SUPPLY LIE, POWER SOURCE SOURCES:UTILITY GRID LABEL LOCATION: AND PV SOLAR ELECTRIC INTERIOR AND EXTERIOR DC CONDUIT EVERY 10 FT, AT EACH TURN,ABOVE AND BELOW PENETRATIONS, - SYSTEM ON EVERY JB/PULL BOX CONTAINING DC CIRCUITS. PER CODE(S):NEC 2023:690.31(D)(2) LABEL LOCATION: UTIUTY SERVICE METER AND MAIN CAUTION :SERVICE PANEL.PER CODE(S):NEC 2023:705.30(C) WARNING RAPIDSHUTDOWNSWITCH MULTIPLE SOURCES OF POWER POWER SOURCE OUTPUT CONNECTION FOR SOLAR PV SYSTEM DO NOT RELOCATE THIS I /\ OVERCURRENT DEVICE N/ 1N1 , LABEL LOCATION: \_ LABEL LOCATION: INSTALLED WITHIN 3'OF RAPID SHUT DOWN ADJACENT TO PV BREAKER AND ESS SWITCH PER CODE(S):NEC 2023:690.12(D)(2),IFC s u n r u n OCPD(IF APPLICABLE). 2018:1204.5.3 PER CODE(S):NEC 2023:705.12(6)(2) ❑ - 4„ , i A WARNING SOLAR PV SYSTEM EQUIPPED #180120 THIS EQUIPMENT FED BY — 1 fiBS MYLES STANDISH BLVD,TAUNTON,MA,m7Bo-7331 MULTIPLE SOURCES.TOTAL WITH RAPID SHUTDOWN Axa RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN CUSTOMER RESIDENCE: SUPPLY OVERCURRENT DEVICE NUNZIO NAPOLITANO SHALL NOT EXCEED AMPACITY OF / I } —SOLAR PANELS ON ROOF 76 CAMP ST,YARMOUTH,MA, BUSBAR L 02673 LABEL LOCATION: 3 TURN RAPID SHUTDOWN INVERTER (EXT) PV LOAD CENTER(IF APPUCABLE)AND SWITCH TO THE"OFF' ov ParE�s- MAIN TEL.(508)498-4489 ANY -PRODUCTION METER OFBREAEL THATS LEIUZES"THE SUM POSITION TO SHUT DOWN PANEL(INT) APN:YARM-000045-000021 PER CODE(S):NEC 2023:705.12(8)(3) PV SYSTEM AND REDUCE —FUSED AC DISCONNECT PROJECT NUMBER: SHOCK HAZARD INTHE -SERVICE ENTRANCE ARRAY.INEW 223R-076NAPO ...-. .- -- DESIGNER: (415)580-8920 ex3 MAXIMUM ACOPFRATINGCURRFNT 32.O0AMPS 76 CAMP ST, YARMOUTH, MA, 02673 SAMEERSHAKUR NOMINAL OPERATING AC VOLTAGE. 240 VAC 1 ` , SHEET LABEL LOCATION: PER CODE(S):NEC 2023 705.10(2) SIGNAGE LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF DISCONNECTING MEANS TO WHICH THE PV SYSTEMS INTERCONNECTION. ARE CONNECTED. REV A 4/12/2023 PER CODE(S):NEC 2023:690.54 PER CODE(S):NEC 2023:690.12(D) PAGE PV-5.0 Template_ve n_40.87