HomeMy WebLinkAboutinspection_report 12B Sylvan Way FAILTown of Yarmouth, MA
Inspection Report
Inspection: INSPECTION
Inspector: Logan Patrick
Inspection Date: Sep 08, 2023
Record: Rental Certificate #BHR-23-37617
Location: 12 SYLVAN WAY, SOUTH YARMOUTH, MA 2664
Applicant: MONISSA SOLBERG
Rental Inspection
Overall Result: Fail
Overall Remarks:
Inspection is for 12B Sylvan Way
Checklist:
1.
Number of Bedrooms
Result: Pass
Remarks:
1
2.
Maximum Occupancy: Based on septic system capacity, number of bedrooms and bedroom square footage
Result: Pass
Remarks:
2
3.
Basement
Result: Pass
4.
Electrical Panel
Result: Pass
5.
Copy of Tenant's Legal Rights have been issued to tenant.
Result: Pass
105CMR 410.00 0Minimum Standards of Fitness for Human Habitation
(State Sanitary Code: Chapter II)
Result: Pass
410.100 Kitchen Facilities
*
Result: Pass
410.110 Bathroom Facilities : Sinks, Toilets, Tubs & Showers
*
Result: Pass
410.120 Approved Toilets
*
Result: Pass
410.130 Water supply
Potable Water/Sanitary Drainage
Result: Pass
410.140 Plumbing Connections
*
Result: Pass
410.150 Hot Water
110-130 °F for faucets & 110-120 °F for bathtubs a & showers
Result: Pass
410.160 Heating Systems
*
Result: Pass
410.170 Venting
*
Result: Pass
410.180 Temperature Requirements
Owner shall proved heat in every habitable room & every room containing a toilet, shower or bathtub from September
15th through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am to 11:00 pm
Result: Pass
410.200 Provision and Metering of Electrical or Gas
*
Result: Pass
410.210 Provision of Oil
*
Result: Not Observed
410.220 Natural and Mechanical Ventilation
*
Result: Pass
410.230 Owner's Laundering Responsibilities
If owner provides bed linens, towels, pillows or mattress
Result: Not Observed
410.235 Owner's Installation, Maintenance and Repair Responsibilities
*
Result: Pass
410.240 Occupant's Installation and Maintenance Responsibilities
*
Result: Pass
410.250 Asbestos-containing Material
*
Result: Not Observed
410.260 Means of Egress
*
Result: Pass
410.270 Locks
*
Result: Pass
410.300 Electrical Supply & Illumination
*
Result: Pass
410.310 Auxiliary Emergency Lighting Systems & Exit Signs
For properties with 10 or more units
Result: Not Observed
410.320 Electrical Service
Temporary Wiring, Amperage
Result: Pass
410.330 Smoke Detector and Carbon Monoxide Alarms
*
Result: Pass
410.400 Owner/Manager Contact Information and Notice of Occupants' Legal Rights and Responsibilities
Contact information and postings inside and outside of home
Result: Pass
410.410 Building Identification
*
Result: Pass
410.420
Habitability Requirements
Result: Pass
Remarks:
Bedroom
Front 8.7' x 13.6'
410.430 Natural Light and Obstructions
*
Result: Pass
410.470 Lead-based Paint Hazards in Residence
*
Result: Not Observed
410.500 Owner Responsibility to Maintain Building & Structural Elements
*
Result: Fail
Remarks:
See report for 12A
410.510 Occupant 's Responsibility Regarding Building and Structural Elements
*
Result: Pass
410.520 Protective Railings and Walls
*
Result: Pass
410.530 Weather-tight elements
*
Result: Fail
Remarks:
See 12A Report Section 410.500
410.540 Installation of Screens
*
Result: Pass
410.550 Elimination of Pests
Owners & Occupants are responsible for the control & elimination of pests
Result: Pass
410.560 Refuse
*
Result: Pass
410.570 Maintenance of Areas in a Sanitary and Safe Condition
*
Result: Fail
Remarks:
See 12A Report - all occupants have access to yard/shed
410.630 Conditions Deemed to Endanger or Materially Impair Health and Safety
One or more of the violations cited on this report may materially impair the health or safety and/or well-being of any
person(s) occupying the premises
Result: Not Observed
This inspection report is signed and certified under the pains and penalties of perjury.
Inspector's signature and date
Result: Pass
Remarks:
Logan Patrick 09/08/2013