HomeMy WebLinkAboutEngineer PlansACCESS COVERS MUST BE WITHIN 6' OF FINISH GRADE /0/.0 RECIRCULATING FIRST 2' TO LINE BE LEVEL 6• RECIRC PUMP 3 OUTLET NORWECO SINGULAIR D-BOX MODEL 900 DN �CRUSHEDSTONE OR COMPACTED BASE PROF I L : NOT TO SCALE 700 BM. CB/OH FND £L - 99.73 9' MINIMUM. DES I vN CR I TER I A : 3 ' MAXIMUM COVER DESIGN FLOW: MIN 2' OF PEASTONE 2 BEDROOMS AT 1/0 G.P.D. PER BEDROOM EQUALS 220 G.P.O. 3/4' - 1 112' D/A. UE DOUBLE WASHED STONE NO GARBAGE GRINDER °o 4 HIGH CAPACITY INFILTRATOR SEPTIC TANK REQUIRED: 220 G.P.D X 200V - 440 GAL.(1500'GAL MIN) CHAMBERS W/3.5'1 STONE AROUND SEPTIC TANK PROVIDED: NONE AS PER PERMIT 2-l0'W X 19'I X !0'd FOR NORWF •.0 SINGULAIR SYSTEM. SOIL ABS(•' PTION SYSTEM REOUIRED: INVERT ELEVATIONS: INVERT AT BUILDING: 98.5 INVERT /N SINGULAIR UNIT: 98.0 INVERT OUT SINGULAIR UNIT: 97, a INVERT IN 0l ST. BOX: 97.5 INVERT OUT D/ST. BOX: 97.33 INVERT IN LEACH CHAMBER: 97.23 BOTTOM OF LEACH CHAMBER: 96.4 ADJUSTED GROUND WA TER : N/A OBSERVED GROUND WA TER: N/A BOTTOM OF TEST HOLE */; 89.3 C RATE ( 5 MI NII NCH 1, sTEPHEN HMS. PE. CERTIFY THAT ON NOVEYBER 1994, 1 HAVE PASSED 'HE DES 1 GN Pi ' SOIL EVALUATOR EXAMINATION APPROVED BY DEP AND THAT THE ANALYSIS FAS SOIL TEX' RAL CLASS - I PERFORMED BY ME CONSISTENT WITH THE REQUIRED TRAININO. EXPERTISE AND EFFLUENT OADING RATE - 0.74 GPD/SF EXPERIENCE DESCRIBED IN 310 CMR 15.017. 220 GPD 0.74 GPD/SF - 298 S.F. REOUI RED s10NArm, ArF 4 HIGH CAPACITY INFILTRATOR SOIL TES T P I T DA TA PROVIDED:,/3.5't STONE AROUND, A-460 S.F. CHAMBERS k 0.74 - 340 GPD INDICATES v_ INDICATES 460 S.F. PERCOLA TION OBSERVED TEST GROUNDWA TER TP • I TP #2 0' HORIZON TEXTURE COLOR 99.8 0' HORIZON TEXTURE COLOR 99.8 O ORGANIC 0 ORGANIC 5 99.4 5' 99.4 A LOAMY IOYR A LOAMY IOYR SAND 3/4 SAND 3/4 FENCE 100.3' 10' 99.0 12' 98.8 B LOAMY IOYR p LOAMY IOYR SAND 5/6 O SAND 5/8 28 ............................... 97.5 26 ............................... 97.5 C / MEDIUM IOYR C / MEDIUM IOYR `^40.1SAND 7/4 SAND 7/4 "1 40' TRACE GRAVEL TRACE GRAVEL NO WATER 1 89.3 120'1 NO WATER L89 8 DATE: MAY 1. 2002 TEST BY: STEPHEN HAAS WITNESSED BY: AMY VONHONE PERC RATE: l 2 MIN/INCH IN THE Cif LAYER TP #3 TP 04 100.0 0' 100.2 O ORGANIC O ORGANIC J 99.8 4' ............................ 99.9 A LOAMY IOYR A LOAMY IOYR SAND 3/4 SAND 3/4 10' ............................... 99.2 10' .............................. 99.4 B LOAMY IOYR p LOAMY IOYR D SAND 5/8 SAND 5/6 JO' ............................... 97.5 32' ............................... 97.5 C / MEDIUM IOYR C / MEDIUM IOYR SAND 7/4 SAND 714 42' TRACE GRAVEL 44' TRACE GRAVEL / SM. CB/OH FND y ` EL • 100.75 GENERAL NOTES: I. THIS PLAN IS FOR THE DESIGN AND CONSTRUCTION, OF THE SEWAGE D I SPOSAL SYSTEM ONLY. 2. VERTICAL DATUM IS ASSUMED. FOR BENCH MARKS. SET, SEE SITE.PLAN. J. ALL CONSTRUCTION METHODS AND MATERIALS AND MAINTENANCE OF THE SEPTIC SYSTEM SHALL CONFORM TO MASS. D.E.P. TITLE 5 AND LOCAL BOARD OF HEALTH REGULATIONS. 4• ALL SEPTIC SYSTEM COMPONENTS LOCATED UNDER AREAS SUBJECT TO VEHICULAR TRAFFIC OR GREATER THAN 3' IN DEPTH SHALL BE CAPABLE OF WITH- STANDING H-20 WHEEL LOADS. 5' ALL SEWER PIPE SHALL BE SCHEDULE 40 OR APPROVED EQUAL. 6• D-BOX SHALL BE REINFORCED PRECAST CONCRETE AND WATERTIGHT. D-BOX SHALL BE WATER TESTED TO CHECK FOR LEVEL WHEN THERE IS MORE THAN ENE OUTLET. 7. THIS LOT FALLS ENTIRELY WITHIN A ZONE lI AND IS SUBJECT TO NITROGEN LOADING LIMITS AS PER. .. TI TLE 5. (440 GPD / 40, 000 S. F. I 8. A TWO BEDROOM DWELLING IS PROPOSED ON THIS LOT USING A NORWECO SINGULAIR MODEL 900 DN TO COMP- ENSATE FOR THE LACK OF LAND AREA. 9. THE NORWECO SINGULAIR UNIT IS TO BE INSTALLED. OPERATED. MONITORED AND MAINTAINED AS PER THE MANUFACTURERS SPEC / F I CA T / ONS AND THE RENEWAL OF PILOTING APPROVAL LETTER FROM DEP, l0. BEFORE CONSTRUCTION CALL 'DIG -SAFE'. 1-888-DIG-SAFE AND THE LOCAL WATER DEPT. FOR LOCA TION OF UNDERGROUND UTILITIES. 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEED RESTRICTIONS OR ZONING REGULATIONS. IT SHALL REMAIN THE CL I ENTS RESPONSIBILITY TO OBTAIN ALL PERMITS. SPECIAL PERMITS. VARIANCES ETC. FOR :THIS PROJECT. 12. IT SHALL REMAIN'THE CLIENT'S RESPONSIBILITY, TO HAVE THE PROPOSED BUILDING FOUNDATION DESIGNED TO ACCOUNT FOR THE EXISTING GRADE AND SOIL CONDITIONS AT THE LOCATION OF THE PROPOSED BUILDING. Eq rd 120 NO WATER 90.0 120'1 NO WATER L 90 2 OCT 2 8 2o02 DATE: rucY lo. 2002 TEST BY: STEPHEN HAAS HEALTH D EPT. PERC RATE: f 2 MIN/INCH IN THE CI LAYER h Health Department` +, S % E P L A IV O F- L A /V D 'PROVED r 64 M -L. VILLE ROAD. "AP 100, PARCEL I Date .Y SOU T1 YA R"OU T/1 / i , . - R R E P.4 RE O R. �..� .... .. ! 4 YEL L O W PERCH C / R�_'i E . "A SHPEE . "A 02649 ' SCAL E : / 20 _lUli 0.1 2002 REVISED: JUL Y. 10. 2002 t/•�` ������������""""""�� REVISED: OCTOBER 7• 2002 'EAGLE S U FR V E Y I N G I N C 923 Route 6A Y o r mo u t h p o r t MA. 02675 ( 508 ) 362-8 1 32 (508) 432-5333 0 10 20 40 LOCUS MAP