Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST • Location: A.M. Lot 2�3ffv Zone of Contribution: In Out Acreage Commercial: Residential: f /Gec5 Street: Village: Floor Plan: a Bedrooms: Owner: . _ - Installer: _. , ,, , Address: _ - Phone: ( f ,; i) Phone: Builder: Engineer: = . Address: ', „r, Phone: Phone: r� f i....) N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table ./4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: 5. Water line 10 ft from septic components Var.: J - 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands wars: :� 1 fr` / I 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: - 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: / 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above ad. water or bottom of test hole Var.: I 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Prososed contours are suitable 1111.011111111. 17. System meets slope requirements- min. 1/8", %"preferred 18. S stem meets breakout re.uirements 19. S.ecified tee sizes are 'roper, vas baffle on outlet tee PVC liner: Nall: - 20. Sewage :.,ad is under 10,000 .d for .angel , 21. Noa arbaoe dissosal 22. System ade uately sized for its intended use 23: Minimum 6"stone or comaacted below tank and dboxMil 24. Manhole covers within 6"of grade, pump chamber cover to gradeMil 1.1111111111111 25. Ins.ection sort on alastic chambers/leach field 26. Electrical .ermit for 'urn. chamber/Sesarate meter for duplexes 27. Puma system-2"line,wee. hole,check valve, tee in dbox, sump size _�_ 28. Se tic tank/pump chamber to be factory waterproofed _111111111111111111 29. Vent provided if leaching below 3 feet,under driveway/parkinaIIIIIIIIIIIIIIIII 30. Buo anc calculations for-tank/sums chamber -� 31. Engineer to ins ect and certify soils: wall: ,.„ In 32. Enrineer/Re:istered Sanitarian and Land Surveyor stam.s!signature commercial: 111111111 33. H-20 loading is sub'ect to vehicular traffic, : oundwater _®_ 34.Title V Ap.lication and aermit fee, installer signature 35. Foundation footing min. 2 feet above ad'usted around water for new house _®- 36. Deed Restriction re•uired max. ®- 37. Check area lots for groundwater/Label • ound eater in Assessor's Ma. d ®_ MIMIPlan reviewed by - ------- cool