Loading...
HomeMy WebLinkAbout2023 Sign Off Transmittal - New 3 brm Home "Y" kI,' TOWN OF YARMOUTH *-:lik; RECEIVED HEALTH DEPARTMENT PERMIT APPLICATION SIGN OFF TRANSMITTAL staEio 2023 HEALTH DEPT To be completed by Applicant:Building Site Location: (4, Olc•cr 1 'M O(1 hl 0. . W )t/AP,A00 4-k MA OX6 7" Proposed Improvement: N e W \te Cl yiA ,e__ -----> Applicant: 6\r(VeS G'`{ Tel. No.:6)Z-`p.1 - a 33 Address:Lk :5k 11)4n 5 T. Sdmm,ry►I ) e 1(A(4- OD--N -5 Date Filed: 51 ci ) -3 I **If you would like e-mail notification of sign off please provide e-mail address:3-A ftlr.S .. 1`tor_Q Pt*. ri Owner Name: Perrr 3 U'e.._ Owner Address: 5 k- , S 4 5crrnw"I I(T IAA- Owner Tel.No.: f -TA -04193 �A`t3 RESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans, to include: (1.) Site Plan showing existing buildings, water line location, and septic system location; (2.) Floor plan labeling ALL rooms within building (all existing and proposed) - Note:Floor plans not required for decks, sheds, windows, roofing; (3.) If necessary, Title 5 application signed by licensed installer with fee. REVIEWED BY: Ufa DATE: C' (- 3 PLEASE NOTE COMMENTS/CONDITIONS: nb�Cx--4 rtrn�-- o k-- / pre.4,4 *13.0' MIN. SYSTEM PROFILE PROVIDE MIN. 20" DIAM, WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE) 2" PEASTONE OR GEOTEnt LE 16.0' FILTER FABRIC OVER STONE PRECAST H-10 RISERS (TYP.) 2*0 12.42' MINIMUM .754 OF COVER OVER PRECAST NOTE: 2" MIN. WALL THICKSS REQUIRED � 711 13.5' NE---------- REQUIRED PVC L 6' MIN. SUMP PIPES LEVEL 1 ST 2' 12' MIN. INT. DIM. �1500 GAL H-1 EPTIC TAN TEE -0 -000 T D-BOX 0 0-0 0,00,0 WATERTES -000 ;?00 OMO' FOR LEVELNESS '? 14' UQ. LEVEL (ACME OR EQUAL)11 . J67' .5' ALL SYSTEM COMPONENTS SHALL BE MARKED WITH MAGNETIC TAPE OR COMPARABLE MEANS FOR FUTURE LOCATION, CONCRETE COVERS TO WITHIN 3" GRADE 2% SLOPE REQUIRED OVER SYSTEM MORTAR ALL OMPONENTS 0 BLOCKS OR CPRECAST RISERS H-1 4' ENDS 1 5' (TYP-) IMS It SET. SIbES Z' of. MW DOpoOffaQp00�0oOdpQOQOpa pia 0 0 0 0 000 10? L H-10 500 GAL. LEACHING "CHAMBER BY ACME PRECAST OR EQUAL. 5/4"-1-1/2" DOUBLE WASHED STONE' (2) UNITS REQUIRED 'JvvoLr 6" CRUSHED STON OR MECHANICAL OF --STONE: 30' X 9.83' I- COMPACTION. (15.2 (21) 'C Q (_L.5% SLOPE) (--Z-X SLOPE MIN.) FOUNDATION- 17' - SEPTIC TANK - 1' - LEGEND- 99 EXISTING CONTOUR X EXIST. SPOT ELEV. -[991-- PROPOSED CONTOUR 198-41 PROPOSED SPOT EL. THI -q•' TEST HOLE 2% -e-� SLOPE OF GROUND UTILITY POLE FIRE HYDRANT N07- NOT ALL SYMOW MAY APPEAR IN DR4WM -I d�M (-2-x SLOPE) D' BOX 15' - *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM ENGINEER:______ DAN I EL E. GONSALVES, WITNESS: JAY GARDINER DATE: 9/28/22 SE #1135137 - PERC. RATE CLASS SOILS ELEV. ELEV. 0" 0$p 14.5' 14.0' A A LS LS 1 OYR 44/21 OYR 4/2 10" 12" B B LS LS 2611 1 OYR 5/6 12.3' 28# 1 OYR 5/6 11.7' PERC MS 2-5Y 7/4 C IVIS 2.5Y 7/4 3.5' 132" 2L NO GROUNDWATER ENCOUNTERED LICE #22-211 Scale: 1 20' 4 C mzum� 3.0' BOTTOM TH-2 1 NO GROUNDWATER FOUND NOTES 1. DATUM IS NAYQ 0 2. MUNICIPAL WATER IS AVAILABLE 3. MINIMUM PIPE PITCH TO BE 1/8- PER FOOT. Locus; 4. DESIGN LOADING FOR ALL PROPOSED PRECAST k' UNITS TO BE AASHO H-LQ 5. PIPE JOINTS TO BE MADE WATERTIGHT, 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE L WITH 310 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. Lewis Lewis 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. pond Day 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD P OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND LOCUS MAP VERIFYING THE LOCATION Of ALL UNDERGROUND & OVERHEAD UTILITIES PRIOR TO COMMENCEMENT OF SCALE 1"=2000'± WORK. 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL ASSESSORS MAP 23 PARCEL 81 BE REMOVED BENEATH AND 5' AROUND THE PROPOSED LEACHING FACILITY. LOCUS IS WITHIN FEMA FLOOD ZONE X (AREA OF MINIMAL FLOOD HAZARD) AS SHOWN ON COMMUNITY PANEL #25001CO588i SYSTEM DESIGN: UMIC.L; CG-ARBAGE DISPOSER ISNOT ALLOWED� ($r�bpoSED4jEBDROOM D' LLING DESIGN FL DROOMS 0 110 GPD = 33-01 GPD 5G USE A 330 G DESIGN FLOW SEPTIC TANK: 3-30 GPD (2) = 16160 USE A 1500 GAL. SEPTIC TANK LEACHING: SIDES: 9.83) 2 (.74) = 118 GPU BOTTOM 30 x 9.83 (.74) .218 GPD TOTAL: 454 S.F. d' 336 GPD USE (2) 500 GAL. LEACHING CHAMBERS (ACME OR EQUAL) WITH 2.5' STONE AT SIDES, 4' AT ENDS AND 5' BETWEEN UNITS 7 Z� '/' I - I - - 1 '0 (;q�- M A DATE OARD OF -1EALTH Yarmouth Health Department ZONING DISTRICT: R-25 DISTRICT PROPOSED MIN. LOT SIZE 25,000 S.F. 9600 S.F. MIN. LOT FRONTAGE 150' 80' MIN. FRONT SETBACK 30' 41.5' MIN. SIDE SETBACK 15, 15.3' MIN. REAR SETBACK 20' 45.2' MAX. BUILDING COVERAGE 25% 14.9% MAX. BUILDING HEIGHT 35' 28'± MERRYMOUNT LLC 40 SKEHAN ST SOMERVILLE, MA 02134 REFERENCES DOC 1476362 PLAN BOOK 18 PAGE 35 LCP 11435A RECEIVED MAY 10 2023 HEALTH DEPT TITLE 5 SITE PLAN am Date OF #6 MERRYMOUNT ROAD WEST YARMOUTH, MA PREPARED FOR S�' nDANIE',2 JAMES IGOE 1 0 JALA DANt - CNIL -,IA i A N 465D2 DATE: MAY 3, 2023 4 REV: MAY 8, 2023 (SETBACKS) off 508-362-4541 J, f rno zr,) noon DATE DANIEL A. OJALA, P.E., P.L.S. ax - - downcope.com @) Ifews topeenfe fill Inc. fte. civil engineers land surveyors Z) 939 Main Stree t ( Rte 5A) YARMOUTHPORT MA 02675 22-21' P.T. 2 x 8 LEDGER W/ ( 1 )-5/8" LEDGOKLOK BOLTS 1 G" O.C. STAGGERED, FLASH EHIND — BASEMENT 49'-G" 21- 10" 8'-0" 6'- 10" I, 4' 9" 5'-4" ,, 4'-3' 4'-9" u 3'-G"± I, 9'-3" /7), - - - - - -I A3 I I e C 3-2 x 65 I BILCO 'C' I A3 A3 BULKHEAD I v xP.T. 2 x 815 @ I G" o.c. Q N `r BASEMENT I I BASEMENT ----- WINDOW—� ---- I— WINDOW — — — — — — — — — — — — — — — — r----------- - - ---- - - - - - - - - - - - - - - - - --- - - --- -- VDKOP --- TOP OF IF ND. NEW WALL AT DOOR FU LL j BASEMENT I I I TYP. WALL CONST.- II I I I I-2XGSTUDS @ IG"o.c. (4" CONC. SLAB) I - 1 /2" PLYWOOD SHEATHING 2 x 10 FLOOR JOISTS @ I G" o.c. I I I - G" BATT INSULATION (R=2 1 ) - 1 /2" GYP. BD. - W.C, SHINGLE SIDING 8'-8" 3'-8" 7'-2" # 7 -2 I I I I - TYVEK I I I 1 1 TYPICAL H55 3 112 x 3 112 x 1 /4 4" DIA. STEEL TYPICAL BEAM POST UP/DN. LALLY COLUMNS BEAM POCKET — _ _ _ POCKET I GARAGE —1 —1 (4" CONC. 5LAB ON GRADE o PITCH 2" TO O.H. DOOR) CONT. 3- 1 3/4 x 9 1/2 LVLI I I GIRT N I I _ _ I—_� L--J,-- L-- TYPICAL 4 D 2'-0' I STEEL LALLY COLUMNS - 1 2-1 3/4" x TYPI CAL 3 G" x 3 G" x 1 2" I I I ( 9 1/2" LVL's CONC. FOOTING N TYPICAL 30" x 30" x 12" :2-- NCONC. FOOTING > BASEMENT I _ _ x WINDOW X ( m m m I I I I x x c) I I N N m m I I ATO h DOOR FND. WALL 12-1 3/4" x <v N I qk — — — — — 19 1 /2" LV L's I — — — — — — — --_—J Tj ------ CONC, ---- —-------------------� ----- APRON f I I iL----- — — — — — — --——— — — — —- J TYPICAL 10" x 20" CONCRETE FOOTINGS TYPICAL 8" CONC. W/345 BARS FOUNDATION WALL 3"-4" FROM BOTTOM w/ 244 BARS AT TOP BOTTOM AND MIDDLE AA B C 2' 2 2'-0' fOLINDATION PLAN NOTE: FOUNDATION CONTRACTOR TO PROVIDE 5/8" DIA. ANCHOR BOLTS AT 42" o.c. WITh MINIMUM EMBEDMENT OF 7" INTO CONCRETE. ALL SILL PLATES TO BE CONNECTED USING 3"x3"x 1 /4" SQUARE PLATE WASHERS. � BUILDING SECTION @GARAGE (DCOPYRIGHT 2023 BY THOMA5 A. MOORE DESIGN CO. T"Q'/' A pOOF COIN FTER5 @ I G" o.c. DID ROOF SHEATHING SHINGLES K INSULATION ,S (K=40) )ARD OTHERWISE) ✓ALL CONST. )DS @ I G" o.c. /OOD SHEATHING NSULATION (R=2 1) BD. NGLE SIDING TYPICAL 8" CONCRETE FOUNDATION WALL5 w/2-#4 BARS AT TOP * BOTTOM TYPICAL 10" x 20" CONC. FOOTINGS w/345 BARS CONT, WITHIN 2"-3" OF BOTT. SECOND FLOOR 5UBFLOOR TOP OF PLATE N v- FIRST FLOOR 5UBFLOOK Ix OC LN� ISTftI 0 I I 1 /2" GYP. BD. ON I I x 3 STRAPPING @ I G" o.c. I MASTER MASTER BATH BEDROOM I I j 2 x 4 STUDS @ I G" o.c. W/ 1 /2" GYP. BD. BOTH SIDES I I 9 1 /2" TRUSS JOISTS @ I G" o.c. I I STEEL BEAM SEE FRAMING PLANS LIVING CN I. TYPICAL ROOF CON5T. 1-4 11 2 x 10 ROOF RAFTERS @ I G o.c. ROOF SHEATHING ~j CO - 1/2" CDX PLYWOOD ASPHALT ROOF SHINGLES w I—'' �-+ CO - - 1 5LB. FELT PAPER ___ __ - 8" SPRAY FOAM INSULATION AT ROOF RAFTERS (K=40) ►—� W - 2 x 12 RIDGE BOARD (UNLESS NOTED OTHERWISE) �� w I I � w I w ~ �..� w I TOP OF PLATE bb� mb bobbbb�jb 2 x 10 FLOOR JOISTS @ I G" o.c.�jtJU0UU00 000000 3-1 3/4" x 9 1/2" LVL GIRT 9" BATT. INSULATION (R=3C) 4" CONC. SLAB FULL BASEMENT L_ — — _J BUILDING SECTION • • • DINING/LIVING 2 x 8 CEILING JOISTS I G'\o.c. 1/2" GYP.�BD\\CN x x I x 3 5TRAI�PING a§ I G" O.C. ,BEDROOM DEDRCI 9 1 /2" TRU55 JOISTS @ I G" c.c. BEAM 9" BATT. INSULATION (R=3 1) DEN/ nFFirF DATH 2 x 4 STUDS @ I G" o.c. W/ 1 /2" GYP. BD. BOTH SIDES I I ii I I 2 x 10 FLOOR JOISTS @ I G" o.c. 3-1 3/4" x 9 1 /2" LVL GIRT \-9" BATT. INSULATION (R=30) .. FULL BASEMENT BUILDING SECTION @DEN/BATH/BDRMS SECOND FL. 5UBFLOOR — TOP OF PLATE FIRST FLOOR SUBFLOOR 5/6" DIA. ANCHOR15OLT5 @ 32" o.c. TYPICAL 8" CONC. FOUNDATION WALL w/ 244 BARS AT TOP BOTTOM AND MIDDLE DAMPPROOF ALL WALLS BELOW GRADE TYPICAL 10" x 20" CONCRETE FOOTINGS W/345 BARS 3"-4" FROM BOTTOM TYPICAL ROOF CON5T. 2 x ) 0 ROOF RAFTERS @ I G" o.c. 1/2" CDX PLYWOOD ROOF SHEATHING ASPHALT ROOF SHINGLES 1 5LB. FELT PAPER 2 x 12 RIDGE BOARD (UNLESS NOTED OTHERWISE) 8" SPRAY FOAM INSULATION AT ROOF RAFTERS (K=40) TYP. WALL CON5T. 2xGSTUDS @ IG"o.c. 1/2" PLYWOOD SHEATHING G" BATT INSULATION (R=2 1 1 /2" GYP. BD. W.C. SHINGLE 51DING 'TYVEK' 5/8" DIA. ANCHORBOLT5 TYPICAL 8" CONC. FOUNDATION WALL w/ 244 BARS AT TOP BOTTOM AND MIDDLE DAMPPROOF ALL WALLS BELOW GRADE TYPICAL 10" x 20" CONCRETE FOOTINGS W/345 BARS 3"-4" FROM BOTTOM O � � � O I 00 O 00 w O 6' N � N (� O W o O W �✓ l � T� O W� W NOTE: THE PLANS SHOWN ARE THE SOLE PROPERTY OF THE DESIGNER AND CAN NOT BE COPIED, REPRODUCED AND/OR ALTERED WITHOUT THE EXPRESS WRITTEN CONSENT OF THE DESIGNER SCALE 11411 _ I 1_011 DATE : RECEIVED 4/G/202 3 MAY 10 2021 liM'M DEPT. P ROJ . N 0 . 202 2-488 STAMP : DWG. NO. . M OF k4Si 2 MARK A. y = MCKENZIE o CIVIL No. 39068 S�ONAI STRUCTURAL 4-6-2 A 3