Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location A.M. Lot p2(, Zone of Contribution: In Out Acr a e /l Commercial: Residential: 74-\ - Street: , L�J 1rr/e /G/2c, Village: Floor Plan: a Bedrooms: Owner: ( I,)(Arc; I k 1( Installer: 405 Address: ,9 plec,y4 5{-_ eN. Y Phone: '79-2`/- s36- 6`/n t Phone: 77.1._ 1'1-b- bv6o Builder: Engineer: 0S C--- 6 ro-P Address: Phone: Phone: SAY7 S55 N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material, above water table -- -- - 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: - - 5. Water ine 10 ft from septic components Var.: ( - 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic :ank minimum 10 ft from foundation, deck Var.: I 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: 10. Leaching minimum 150 ft from drinking w,velV25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 1 12. System meets all other setback requirements Var.: { 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: HHH. 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable '� 17. System.meets slope requirements-min. 1/8", '/"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specifiei tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel _ 21. No garbage disposal 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox 24. Manhole'covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrica.permit for pump chamber/Separate meter for duplexes 27. Pump sy.tem-2"line,weep hole,check valve, tee in dbox, pump size v 28. Septic tank/pump chamber to be factory waterproofed J 29. Vent provided if leaching below 3 feet,under driveway/parking ✓ 30. Buoyancy calculations for tank/pump chamber 31. Engineer to inspect and certify soils: wall: commercial: tz 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ` 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house v 36. Deed Restriction required max. #bedrooms: max. flow: gpd 37. Check area lots for groundwater/Label oundwater � ju-flssessor's Map Plan reviewed by. . Li��tL 43 - G0l0;