Loading...
HomeMy WebLinkAboutEngineer Plan / Floor PlanSYSTEM PROFILE LEGEND - 99 - EXISTING CONTOUR X 99.1 EXIST. SPOT ELEV. -[99]- PROPOSED CONTOUR 198.41 PROPOSED SPOT EL. TH1 TEST HOLE 2YYY SLOPE OF GROUND UTILITY POLE FIRE HYDRANT NOTE: NOT ALL SYMBOLS MAY APPEAR IN DRAWING WALKOUT CRAWLSPACE WITH FLOOD VENTS . LOWEST ADJACENT GRADE 9.0 *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM NOTES PROVIDE INSPEC ORT TO GRADE ALL SYSTEM GOMPONENTS SHALL BE T10N P MARKED WITH MAGNETIC TAPE OR 4" SCH40 PERFORATED PVC DOWN TO 1. DATUM IS NAVD 88 COMPARABLE MEANS FOR FUTURE LOCATION. SAND AT BOTTOM LEACHING FIELD, PROVIDE 4" THREADED COVER AND 2. MUNICIPAL WATER IS EXIS71NG LEBARON LA910 CAST IRON ACCESS 4" VENT, PERF. ''i SLOPE REQUIRED OVER SYSTEM PORT H-20 CONSTRUCTION. „ ALARM AND CONTROL PANEL RUNS OVER 2 3. MINIMUM PIPE PITCH TO BE 1/8 PER FOOT. TO BE INSTALLED INSIDE PROVIDE CHARCOAL FILTER ACCESS COVERS TO WITHIN 6" OF FIN. GRADE BUILDING. ALARM TO BE ON DRILL LAST HOLE IN EACH AND INSECT SCREEN 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TOF = 12.1 SEPARATE CIRCUIT FROM PUMP PROVIDE QUICK DISCONNECT/BALL VALVE ',`OR PUMP LATERAL ON TOP TO VENT TO BE AASHO H-10 LALL WIRING TO CODE. AIR WHILE LATERAL FILLS FEMALE ADAPTOR & THREADED PLUG 10.0 ACCESS COVERS TO WITHIN 6" OF FIN. GRADE 10.0 2"0 THREADED END CONNECTION 5. PIPE JOINTS TO BE MADE WATERTIGHT. MINIMUM .75 OF COVER OVER PRECAST 11 0' SCH 40 PVC PRECAST H-10 RISERS (TYP.) 2.0 KILL LANIINU I3AbLMLNI AREA TO ELEVATION 9.2 MIN. 10" 1500 GAL H-10 14" 8.17' TEE SEPTIC TANK TEE ZABE1 RVER OUTLET TEE W/ExiEAISIOM 4' LIQ. LEVEL (ACME OR EQUAL) , J°O O O O O O O O O O O O O O O O O i • 0060 O O O O O O o 0 0 0 0 0 0 0 0 0 0 0 00000,0000000000000000000000000000000000t n10n0„0.�_n_n_n.n n o 0 0 0 n.n_n_n_n_0_c 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH INV. IN 7.88' 1/4" SHIELDED ORIFICES 10.17' 310 CMR 15.000 (TITLE 5.) 1000 GAL. H-10 P C / 2PRESSURE LINE99�1 " IfiV. 10.0' 610 GAL.+ SLOPE TO DRAIN BACK o0 0 0o dodo 0 Of 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO FLOAT SWITCH ALARM ON RESERVE 0 oo oo 00 oo�_ o�sz-_-oQ of BE USED FOR LOT LINE STAKING OR ANY OTHER SETTINGS: 0.25" WEEP HOLE _moo -- _ __ _ _ - -__ -- - 5' PURPOSE. PUMP ON CHECK VALVE 2" INVERTS LEVEL AT 10.0 W 5" WORKING RANGE 6 z 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. ----- MYERS SRM 4 BOTTOM LEACHING LEVEL AT EL. 9.5' 5" _ SUBMERSIBLE 4/10 HP 2" END MANIFOLD 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED PUMP OFF 12" SYSTEM (OR EQUAL) PITCH TO DRAIN BACK TO WITHOUT INSPECTION BY BOARD OF HEALTH AND 0 0 0 0 0 0 0 o O o 0 0 0 0 0 o 0 0 0 0 0 0 0 0 co 0 0 0 00 00 00 00 0 0 0 0 0 0 0 0 PUMP CHAMBER- NO LOW SPOTS. PERMISSION OBTAINED FROM BOARD OF HEALTH. 000000000000o0o0co0o00 . OOOOOOOOc O I L 0 0 0 0 0 0 0 o cO o 0 0 0 0 o O c ACCESS FOR ROUTINE MAINTENANCE MUST BE o o O o o O O 0"0 0 0 0 0 0 0 0 3/4" TO 1 1/2" DOUBLE WASHED STONE Ui 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING PROVIDED FOR ZABEL FILTER. INSTALLER MUST 6" CRUSHED STONE OR MECHANICAL DIGSAFE (1-888-344-7233) AND VERIFYING THE FOLLOW ALL MANUFACTURER'S SPECIFICATIONS I SIDE ELEVATION VIEWOCUS MAP FOR PROPER FILTER INSTALLATION coMPacTION. (15.221 [2]) - LOCATION OF AlALL UNDERGROUND &OVERHEAD UTILITIES ( 2 SLOPE) (1X SLOPE) 19' A FOUNDATION SEPTIC TANK PUMP CHAMBER o \ BENCHMARK: BOUND DH \ =10.1, NAVD88 AROUND AREMOYLREER METERSOFALEACH G FAQ CY Q p o DOWN TO UITABLE SOIL LAYER. E, \' FEMALE ADAPTOR & THREADED PLUG WITH CL ED. SAND, TO ME o SCH 40 PVC SPECIFICATI{) OF 310 CMR .25 (3) ti (� (TYP. BOTH ENDS) �10 (0'cl,, EST FL OR T E RAISED r----------------- -0 FLOOD ESISTANT 1 U CONtTRUOTI LOW Q I ELEVATTfION RED s PROVIDE 140' F M LINER AT 5 '� 772 OFF SAS IN AR A S 0 TOP AT 1 J TH 1 �0 ./ I ELEV. 10.17'. 131�1170 AT EL 17't I 'I" WORK LIMIT _LINE 9 SILT FENCE' O Co �I DWG �; a Q \ I AD&TI-ON , PROPOSED 7 Q�9• \ �� I o VENT (SEE PROPLIE-- SHE FINAL PLACEMENT g O _ 73� • DRIE4AY cn TO BE DETERMINED �� I AFTER CONSULTATION CO N WITH HOMEOWNER 1pJ �$ �_ _ ,� ( DW a �o eta 4�o Sri ~ J V %0 a -_LOED Q M FLOOD/GENT �' 4� o (TYP) l 5i 0y" \ o �s• OP 9 2 oy 1 � Nrc> � �° 34 4, P P PGA no � • DICE ##22- > 09 x ZONE AE I ` S P� �(� 2 77 a (EL. I I) � ROOF DR \ GRRjvE 4r � � 1 Diu Iv °j 1 W f o G � x O O FLOOR PLAN (N.T.S) WORK,44MIT LIN.E�� x` LOT 29 16,674 SF± 0 0 0 1 /4" 0 HOLE AT 5' O.C. ALTERNATE BETWEEN TOP & BOTTOM OF PIPE. EXACT DIAMETER HOLES SHOULD BE SHOP DRILLED WITH A DRILL PRESS TO ENSURE UNIFORMITY. REMOVE BURRS PRIOR TO PLACING PIPE. CLEANOUT (TYR) VENT INSPECT/ON PORT (SEE DETAIL) 34' LEACHING FACILITY z_ 2" TO M PUMP PIT \• z� 2" 0 SCH40 PVC MANIFOLD a PITCH PITCH ---.005 FT/FT MIN ---------------1---- .005 FT/FT MIN. 4.(0' o W 0 n 48 LEACHING FIELD w PLAN VIEW PIPING ETAIL 2.0" 0 SCH-40 PVC LATERAL SNAP -ON l C SHIELD \ DRAIINAGE SLOTS 5.0, _ O < 114 " ORIFICE 0 5' O. C 2'0 PVG LATERAL SEE DETAIL (TYP.) ® 4' O.0 PLAN VIEW LEACHING DETAIL. (N. T. S) ORIFICE SHIELD OS200 ORENCO SYSTEMS INC PH. 1-800-348-9843 OR EQUAL. - 219 CENTRAL FED END MANIFOLD 2" PRESSURE LINE TO LEACHIMG ADJ. G.W. EL.= 4.5' PRIOR TO COMMENCEMENT OF WORK. _ �� SCALE 1 =2000 f 11. ANY UNSUITABLE MATERIAL ENCOUNTERED SHALL BE REMOVED BENEATH AND 5' AROUND THE PROPOSED ASSESSORS MAP 22 PARCEL 235.1 LEACHING FACILITY. 12. EXISTING LEACHING FACILITY SHALL BE PUMPED AND LOCUS IS WITHIN FEMA FLOOD ZONE REMOVED OR PUMPED AND FILLED WITH CLEAN SAND. AE (EL. 11) AS SHOWN ON COMMUNITY 13. INSTALLER TO VERIFY THE ELECTRICAL SYSTEM IS PANEL #25001 CO588J DATED 7/16/2014 SUITABLE FOR PUMP CONNECTION. ELECTRICAL PERMIT REQUIRED. 14. FLOOD RESISTANT FOUNDA11ON DESIGN BY OTHERS. 15. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. BUOYANCY CALLS: 16. ACCESS FOR ROUTINE MAINTENANCE MUST BE H-10 1000 GAL. PC WEIGHS 8200 LBS PROVIDED FOR ZABEL FILTER. INSTALLER MUST FOLLOW MANUFACTURER'S SPECIFICATIONS FOR PROPER FILTER 1.2' x 8.25 x 5.42 X 62.4 = 3348 LBS UP (OK) INSTALLATION. 1500 GAL.WEIGHS00 LBS 0.92' x iO.5x5.67 62.4 120 418 LBS UP (OK) SYSTEM DESIGN. TEST HOLE LOGS GARBAGE DISPOSER IS NOT ALLOWED EXISTING 3 BEDROOM DWELLING 13871 SE , ERRARI ENGINEER: CRAIG J. F# PROPOSED 4 BEDROOM DWELLING WITNESS: JASON GARDINER DESIGN FLOW: 4 BEDROOMS @ 110 GPD = 440 GPD DATE: 5/11/2022 USE A 440 GPD DESIGN FLOW PERC. RATE _ < 2 MIN/INCH SEPTIC TANK: 440 GPD (2) = 880 REQ. CLASS SOILS PUMP CHAMBER: 440 GPD (1) = 440 REQ. USE A 1500 GAL. H-10 SEPTIC TANK USE A 1000 GAL. H-10 PUMP CHAMBER ELEV. ELEV. LEACHING: 0" 10.0' p" 10.0' 440 GPD (.74) = 595 SF REQUIRED ? A �LS 16.67' X 36' = 600 SF OK /LS 600 SF X .7-, _ :t4A. GPD Off. /� n�1r1 in 9„ 1 CYR 4/6 � � v � ;, 4� 6/ �„ USE A 15' X 40' PRESSURE DOSED PIPE AND B B STONE LEACHING FIELD 20 W15 z 0 Ld 10 Q r 0 I- 5 0 25 50 75 100 CAPACITY - GPM PUMP CURVE FOR MYERS SRM4 4/10 HP PUMP RECEIVF_D So 21 Z0 HEpLrH DIEPT. Yarmouth Health Department Z"PROVED UNSUITABLE SOIL GROUNDWATER ADJ. DATA: WELL: MIW-29 ZONE: A ADJUSTMENT: 1.5' (MAY 20, 2022) �LS 20„ 1 OYR 4/6 8 3' 24" C FS 2.5Y 7/4 120" 3.0' OBS. GW 0.0' 120" OBS. GW AT 84" EL. 3.0 3.0' 0.0' I 1 I I 5 ZS I T rr-m` • L A k I m #55 BAYBERRY RD. WEST YARMOUTH, MA PREPARED FOR ALIREZA BIGDELIAZARI DATE: JUNE 6, 2022 REV: JUNE 30, 2023 (ADDITIONS) REV: AUGUST 1, 2023 (WORK LIMIT LINE) CH OF 1, Scale:1 "= 20' �i OF lyf.4 ,�fe L SS9c :-` / JANIEL s° DANIIELA. I� I OJALA cJl G 0 0 30 40 50 FEET OlAIA CIVIL ! No 40,980P No. 46502 I °F or' off 508-362-4541 ) ��� ass 2 I fax 508-362-9880 downcape.com down cape ell h7eering, loc° civil engineers LCOland surveyors 939 Main Street ( R to 5A) DATE DANIEL A. OJAI A, P.E., P.L.S. YAPMOIJT14POPT MA 17_2675 CJF 22-109 BIGDELIAZARI.DWG