Loading...
HomeMy WebLinkAbout23-A085 53 Gingerbread Lane REVTOWN OF YARMOUTH �"-� r3s 1146 ROUTE 28, SOUTH YARMOUTH, MA 02664-4451 ECEJVJJ D Telephone (508) 398-2231 Ext. 1292-Fax (508) 398-0836 jUM 0 90�D KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE �Ahtvl�H;GHVVAY APPLICATION FOR OLD �11VG's CERTIFICATE OF APPROPRIATENESS Application is hereby made for issuance of a Certificate of Appropriateness under Section 6 of Chapter 470, Acts of 1973 as amended, for proposed work as described below & on plans, drawings, photographs, & other supplemental info accompanying this application. PLEASE SUBMIT 4 COpieS OF SPEC SHEET(S), ELEVATIONS, PHOTOS, & SUPPLEMENTAL INFORMATION. Check All Categories That Apply: Indicate type of Building: Commercial x Residential 1) Exterior Building Construction: New Building Addition _Alterations Reroof Garage Shed x Solar Panels Other: 2) Exterior Painting: Siding Shutters Doors _Trim Other: 3) Signs/Billboards: New Sign Change to Existing Sign 4) Miscellaneous Structures: Fence Wall Flagpole Pool Other: Please type or print legibly: Address of proposed work: 53 Gingerbread Ln Yarmouth Port MA 02675 Map/Lot # f Owner(s): Judson Phelps Phone #: (508) 362-5921 All applications must be submitted by owner or accompanied by letter from owner approving submittal of application. Mailing address: 53 Gingerbread Ln Yarmouth Port MA 02675 Year built: Email: judsonphelpsl@gmall.com Preferred notification method: X Phone X Email Agent/contractor: Empower Energy Solutions, Inc. Phone #: (203)493-2977 Mailing Address: 30 OLD KINGS HWY S # 1001 DARIEN CT 06820-4551 Email: operations@empowerenergy.co Description of Proposed Work: Preferred notification method: X Phone X Email Installation of a safe and code -compliant, grid -tied PV solar system on an existing residential roof. 22 Panels18.91 kw (dc) Signed (Owner or agent): Date: 06/02/2023 ➢ Owner/contractor/agent is aware that a permit is required from the Building Department. (Check other departments, also.) ➢ If application is approved, approval is subject to a 'I 0-day appeal period required by the Act. ➢ This certificate is good for one year from approval date or upon date of expiration of Building Permit, whichever date shall be later. ➢ All new construction will be subject to inspection by OKH. OKH-approved plans MUST be available on -site for framing 8 final inspections. Rcvd Date: & I .?3 Amount Cf C1 Cash/CK #: LM N Rcvd by: 45 Days: Date Signed: Approved Reason for Denial: Signed: Approved with Modifications Denied 1 APPLICATION #: 2 ✓ -An( GENERAL SPECIFICATION SHEET Project Address: 53 Gingerbread Ln Yarmouth Port MA 02675 FOUNDATION: Material: Exposure (Not to exceed 18"): CHIMNEY: Material/Color: GUTTERS: Material/Color: ROOF: Material: Asphalt Shingle Pitch (7112 min) Height to Ridge: Color: SIDING: Material/Style: Front: Sides/Rear: COLOR CHIPS Color: Front: Sides/Rear: TRIM: All windows & doors to be trimmed with: 1x 4 1x5 (Circle one.) Material: Color: RECEIVE[) RECEIVE[) DOORS: Qty: Material: Color: f JUN 0 9 2023 Style/Size (if not listed/shown on elevations): rAhiAOU'rh OLp KING'S HIGHWAY STORM DOORS: Qty: Material: Color: GARAGE DOORS: Qty: Mat'I: Style: Color: WINDOWS: Q !side:: Front: Left: Right: Rear: Color: Manufacturer/Series: Material: Grilles (Required): Pattern (616, 211, etc.) Grille Tvpe: True Divided Lite: Snap -In: Between Glass: Permanently Applied: Exterior Interior STORM WINDOWS: Qty: Material: Color: SHUTTERS: Mat'I: Style: Paneled Louvered Color: SKYLIGHTS: Qty: Fixed Vented Size Color: DECK: Size: Decking MatT Color: Railing Mat'I: Style: Color: WALLSIFENCES* (Max 6' height): Height: Mat'I: Style: Color: (Snow running footage & location on plot plan.) *Finished side of fence must face out from fenced in area. UTILITY METERSIHVAC UNITS: Location: Screening: LIGHTS: Qty: Style: Color: Location(s): LIGHT POSTS: Qty: Material: Color: Location(s): Additional information: 2-General zz APPLICATION* Telephone (508) 398-2231 Ext. 1292 Fax (508) 398-0836 OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 45-DAY TIMEFRAME WAIVER Application #:s- Project Address: RECEIVED .SUN 0 9 2023 r HHIviUU i ri CING'S HIGF 30 OLD KINGS HWY S # 1001 DARIEN CT 06820-4551 Application Received Date: 45 Day Decision Deadline: IIVIle, the undersigned owner, contractor, or agent, do hereby waive the 45-day timeframe for a determination on our application for a Certificate of Appropriateness/Demolition/Exemption by the Old King's Highway Historic District Committee for the following project: Date: 06/02/2023 Signed: Owner Owner Asim Hafeez Contractor/Agent I 11011A k" [0] M1111 N JA [oil] d:I OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE 2023 MEETING SCHEDULE a�j� crj TOWN OF YARMOUTH OLD KING'S HIGHWAY HISTORIC DISTRICT COMMITTEE Applicant's (Owner) Name: Property Address/Location: Hearing Date: t) ABUTTERS' LIST Judson Phelps 53 Gingerbread Ln Yarmouth Port MA 02675 Notices must be sent to the applicant and abutters (including owners of land on any public or private street or way) whose property directly abuts or is across the street from the applicant. The OKH Office will send out notices using the addresses as they appear on the most recent applicable tax list. Note: Instructions for obtaining the abutters Map and Lot numbers can be found on the Old King's Highway Department page on the Town website: www.yarmouth.ma.us Applicant Information: Abutter Information: LFIECRVED0 9 2023 G'S HIGHWAY Map Number Lot Number ��I sty �3s't Application #:3' 8.2018 3 �o TOWN OF YARMOUTH 0 1146 ROUTE 28, SOUTH YARMOUTH, MASSACHUSETTS 026644451 1211 671 1 1 CARTER RICHARD Please use this signature to certify this list of properties CARTER RACHEL directly abutting and across the street from the parcel located at: 75 FAIRBANKS AVE 53 Gingerbread Ln., Yarmouth Port, MA 02675 WELLESLEY , MA 02481 Assessorg Map 121, Loj 84 1211 831 1 1 Andy MW6hado, Director of Assessing LESSER STELLA TR June 26, 2023 THE 47 GINGERBREAD LN RLTY TR 3 WEST WOODS YARMOUTH PORT, MA 02675 1211 841 1 I PHELPS JUDSON H PHELPS BARBARA RAY ^ i RFrF-IV F+D 53 GINGERBREAD LN YARMOUTH PORT, MA 02675 JiJN 2 6 2023 1221 251 ! 1 r AHIVIOUT r. NATHANSON JULIE TR 0 L Q KINGS HIGHWAY NATHANSON FAMILY TRUST 146 EDGARTOWN RD VINEYARD HAVEN, MA 02568 N f'11 h CV N vi N N sp- W rV r� IL Ln fV A � EEE CD� ' u4 2 n n L yy55 w L5 kn y� (NV 7 y �zn O cr o�S2F RECFIVED JUN 0 9 ?_023 rNh[IVIUU I i5 C a 7 c9 LING COISBULTQ�i6 Scott E. Wyssling, PE Coleman D. Larsen, SE, PE Gregory T. Elvestad, PE Empower Energy Solutions 30 Old Kings Highway South #1001 Darien, CT 06820-4551 To Whom It May Concern: 76 North Meadowbrook Drive Alpine, LIT 84004 office (201) 874-3483 swyssling@wysslingconsulting.com June 1, 2023 Revised September 25, 2023 Re: Engineering Services Phelps Residence 53 Gingerbread Lane, Yarmuth Port, MA 8.910 kW System We have received information regarding solar panel installation on the roof of the above referenced structure. Our evaluation of the structure is to verify the existing capacity of the roof system and its ability to support the additional loads imposed by the proposed solar system. A. Site Assessment Information 1. Site visit documentation identifying attic information including size and spacing of framing members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information will be utilized for approval and construction of the proposed system. B. Description of Structure: Roof Framing: 2x6 dimensional lumber at 16" on center. Roof Material: Composite Asphalt Shingles Roof Slopes: 16, 18 & 39 degrees �CGGC�'{■ Attic Access: Accessible K Foundation: Permanent i SEP 2 5 20 C. Loading Criteria Used • Dead Load OLD KING'S H! HVvAY o Existing Roofing and framing = 7 psf o New Solar Panels and Racking = 3 psf o TOTAL = 10 PSF • Live Load = 20 psf (reducible) — 0 psf at locations of solar panels • Ground Snow Load = 30 psf • Wind Load based on ASCE 7-10 o Ultimate Wind Speed = 140 mph (based on Risk Category 11) o Exposure Category C Analysis performed of the existing roof structure utilizing the above loading criteria is in accordance with the 2015 International Residential Code, including provisions allowing existing structures to not require strengthening if the new loads do not exceed existing design loads by 105% for gravity elements and 110% for seismic elements. This analysis indicates that the existing framing members will support the additional panel loading without damage, if installed correctly. Page 2 of 2 D. Solar Panel Anchorage The solar panels shall be mounted in accordance with the most recent Ironridge installation manual. If during solar panel installation, the roof framing members appear unstable or deflect non - uniformly, our office should be notified before proceeding with the installation. The maximum allowable withdrawal force for a 5/16" lag screw is 229 Ibs per inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications. Based on a minimum penetration depth of 2'/z", the allowable capacity per connection is greater than the design withdrawal force (demand). Considering the variable factors for the existing roof framing and installation tolerances, the connection using one 5116" diameter lag screw with a minimum of 2'/2" embedment will be adequate and will include a sufficient factor of safety. Considering the wind speed, roof slopes, size and spacing of framing members, and condition of the roof, the panel supports shall be placed no greater than 48" on centers. Based on the above evaluation, this office certifies that with the racking and mounting specified, the existing roof system will adequately support the additional loading imposed by the solar system. This evaluation is in conformance with the 2015 IRC, current industry standards and practice, and is based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. A-r y yours, Scott E. Wyssli PE MA License No. 505 COA# 001629764 C RIM) SEP 2 5 2023 i Ahiviou i r. i Wyssling Consulting, PLLC 76 N Meadowbrook Drive, Alpine UT 64004 Massachusetts COA #001629764 Signed 9/25/2023 roN LING H W p ui 2 z +n Of Z iL W F V1 RECEIVED SEP 2 5 2023 YAhNIUU � w w w w a rc w w u' � z z m4 o z z ❑ o o �d / r N n ix U) W ° F P W W F uyi ¢ > z z O Z H a J a ly w W zo N NI O ■ RA D H U F- H U) W M LU JPW m z 6 %� Z to iN (D Z W O¢ !1 ` In u rn Q ~ ❑ C O 8 (~Jj J ., C aw Lu U) (D U') 'n W LU �� N Q_' U)N � � ❑: ca Q N } V co O? O co z O M1 Q to (1) 0 UJ W W c-, Q u' W cDjQ r'LO U)22' t W W �U Q Z W Q UCy U_mLU dY U) (3) w _z Juno N �❑ W J Z W •-V �j W Y 3 a NfV ¢ 7 O Cl) J 2 W Y _ Z J W W W ('J J ❑ ti d LL LL W d [I r2 W W fn W W J= Vl Q Z O m F m m w U F U r O Z 8 J 7 mj y Q f7 Z 7 W 4 z O SS J r co CJ m z° O J O z ❑ z ° ° iiiQQQ� } y z ❑ O¢ o m ❑ J O O N O W 0 O ❑� U Z Z ❑ LL Z LL❑ (7 W'❑ m O, Z o '' Z U Z N_ r m O O W f trjy N O a 6 a a W UI mpp 4 Z a W~ O U d Z J 6 2 7�❑ O W J J Q 2 Q a (n J� J q Jq 4 r�� W m n p��� Z w m r❑ r❑ H x i7 a V K O O U Z J K z r w a 7 Zs LL X. w x 4 O 4 K y m 4 LL m W w LL d MU m y w f w w❑❑ J z 0 F- Z W Q O m m } z H r a° m 4 y w w j 7 w 4 7 r J V a o z z O C7 w m W d a o¢°_° i U w W `�' ¢ z m a w o W Q LL w c� a of z O Z N J Z w Z r a F y o U' d U LL W O W❑ 0. N❑ LL W W m❑ O U❑ Z O_= r r' p a O o w r Z Z O 7 wx = w¢_ 7= 'o O rs W y z o i< w`a z ma v o c°i j U4 K w v�i o r i rc u~i w rs a= a= o c°a U3 o W 0 r W `� w 6 a ? U U❑ m K LL E a W a 2 4 m U` a LL (i J m S E {A 0 a r U Q 22 F U W (V t7 O 6 m t G > Z a ❑ Z a z 0 5of it aa$S F ❑ N tL 11❑� V �j O O �m�11 U U O V w d U W z 0 5 a lx W Z 3 2 g�g L1 ❑ S a N a LL u r cOi a , w r S ~ w in F 111 °m o rc a❑ o u W~° F$ d F L7 7 U c7 S p wa ~2 c��i r w V h$ o O a¢ n Z Z m¢ r F 7 7 o K K O m z r O0. i m Y w j us O r rc a O O g 3 F r x a w a J 5 0 N a 9 p>> J z w o p z a z o o a 4 4 m U U p p W W x U U Yl �E Z 2 Z C. d d a ✓� N Vi Jl W N>> 7} 7 }i z Q w It In m o f r w❑ u h a 3 z u p x ❑ u i a z m a a a m Ou ❑ a O w a __ f z 'i �� a a� Su m w w 'o w h� 7 a>� >' 3 2 LU W o U0 Z LL c Q U) Q. �a4 KLLI W r p 21daor- A a ? 0 Q Q F- m W a LC)j6 WjIL +Nn W 0W o a L}� O 2 s C c Uj a m J j FY F D O W %C N a WLU r � m (Z� Z .7 a ---2;-A:��- cr- J _ LU Q o ~ Q Z U m Z Q Z W z U O z O w U W o F zLLJ F- �I'► H LU co LLJ U) z O m U_ �J F- w ❑ — LU J W ❑ Z -7) Z H Z Q ❑ ❑ ❑ J 5 Z O w z � h F J a } RECEIVED S jy r E e N a` S U 0 Z SEP �} % `� 2 5 2023 N LL ❑ ° C '. �� y0i C 6DD M m �i O vuj} VAHIUl1U l r� �� �r �e"yh OLD KING 9 HIGHWAY �� m c > ° `� F M =a N ` J Y Y M OdD�19�13DNID L6 rr Q Z o Q ❑ Q Q co m waM Uj CD Z)CA IL z J _ c w co cl) LI) w o w#? 4m ° Of o a z wCA ° o LU a T zj �j nz 3'3 .0rL Iw .- 1l' W `',MM Z N _ a _ z o I w W w 0 Z = 5 rc E co o O r Qa w Z O ® d g ® o W Z h _ II 3 U N • V � LL a 5 $ Q LL Y m 5 I70 � u =~ N J e C 3um LL tw a O V) H O N � z � N V N W O U J LU Z LL �O c a? Z o ■ ■ECEIV�� J WO C1 Q a a o U 0 0 C3 1 SEP 2 5 20Z3 ° w r UJ _ °"° � 0 o��� o YAhlViUU I r, z J Z OLD KING'S HIGHWAY ¢ z � � � U U U can a <Z¢ mg� Q m Q` N a UJ Cq (D .If. ilk J Z.L�[� LLI Z5X00 Ill,i llk'k l 'I N a kill' Ltl Q w kll1' kfll �Ikl�l I. kl. Z ~ Z O m O� aw Na �o m �j z V ❑ a Z � 03 U�0 (1Z v W+ a n00 A Y �U 1Yw Z = � � �z = �i O A Z z i� U F zr1y) ! / �| \� ° c M C4 § ) /2\ � ■ ( \ff - | } / t: { o § § Ix z/ LU 00 r RECEIVEDFn m wg< SEP 7 5 202 2 2 # ) |§ C k W \\ zkhviUUTA ° . O� KINGS HIHWAY � m \\ � ° § <�} mac« LU \§/§ § � § U.^ �C6W CO \\u a �§oa 2ƒGf\ - - � U ) t z §) ® W_ ®�§§ (§ _ m d LLI k § i k CO \ ) 2) § cR ° i k § : � R W ,?3-�a5 RECEIVEv SEP 2 5 2023 i AhIVIVU l t I oo r aaaaaw Uzi z z w � Uzi w z w � y U Q d tu m rn w aLLJ xd 5 a I m � z Z w _ a x �s a° o�10 �g 1. uo FA F _ f I I I I I I I I I I I I I I I I I I I I 1 1 I I I I I 5S2 I I I I _ I I� liI I, I� in II I I; I J �I S@ I� I f--- 1F I I I I I I I I I I 4 I r I w I 0 N I Z ' I o I I 11 m F -]III dSW 43 WIIOS tlOQL Q I Y � Y Q� J O Z U (� LLI W J > W W 0 U N W LL a O EwQ w a- co r` Q J W QN m _ L? LLI U ~ CD W C4 K co :=V3<q w y� d Un ? Y J c N w G U w Q }} p U � 4 W W win ZCup �l O N Q J Oq pz Z 2 Q a tz D �a w0 (� Z LO z> O Za �Q I uj �x Z= ' W LU 00 4x �W ¢ Q 0 � W U mw i2a z0 N w w (7 U' w Zw O0 W � o 0 N O/ a 0 rn o) u) yi K Y o f� 0 0 rn U DO � 0 4 � rn ~ o u rn U a LU Z 00 w� 4 r U . w v ❑ W ,g y IL a <a DNCwd O 2O w� HD Ln _ UD ❑ IL ~2 �WOw O OF j ZU}UWY p> w Q O 2 W m Q E U a Y W = a Q� OOUm z�6�°<Mz z v)- � N w w ro U ocD Y c LR N Zo O C � i0 CO C r Woo U 9 7 Q ❑ p r m U N o cn ❑ LUL 0 w� aT N v (J Q UOid n z Y a0a- ao w Qa0 rn� m x O V Z = Y m N LLZZ O p Oc LL O U-0 OUP mco w E zcn077 Uv°'r ° ❑ 7 F.. N oO sc �a U - � LL 0 N CD ZW2 LU C co d oz C m o-° O m i r C) O rn Jcu Z W pp O Z tL m m m w EL 00 W M m` 7 Z W Z Y O J H Q d N V N m ~ 03 03 C N OU m W o m [O A o_ C c� CO�m� �oY U avi JQZ ��a ❑� u Z LU 0 M LO u W $ LO O O O p o Q ` Q Kf u [u ! a a v 0 0 LLJ p H a z a o W Z (' U U Z Ld Z = Z LLJ O Q 0 LO O b D� 0 cry o Lq CD O 0) M LO CO Ud W z o r LO Go 0 0 co rn L Y W O � 0 LL —00 LU ca M N o Z �(D L17 U LLl O z 0' SEP 2 5 20' Y Wh iviou I ri KINGS HIGH W U } K Z) � � M w O a F O o a 0, Z U Z cc Z Q U) Q � z O U W cn T < + _ J a V a o Z oo�z Zrl)z°� W p Z Z U Z) Qnow 6 n af T _ a Q Z LO a) V O O co co 00 � o _ cp LO O aC Q) Q [0 Lj Z m � rO 7(0 Lr) rn o rn U wo z� N C) O 0 (D 0W N0 00 LL 00 0 0 (� Ln rn O L0 C�0 X W o z r Y CO Z1 2 2 W H } w 0 U UD Z LL w O V5 ii 0 � Li � ❑ Q J 2 c) d � � n < Z aN Q ❑ m <m�N wF- aZ�^ w oo = m € Q o a Ln >- U m O= u u S2 M c� J r O w J ❑ US o a Q ww w O C7 w 0 Q , 73~, N Ci y � r � ^ r 7 N r O N d fn Q CL O L-. = O Er c cU 'L c NLo ti " Nv lO OIL C') N �0 E o n R 6 N A N W y .. N U Or O c0 N❑ O Q C Nr Z+S L 2 U E $ a -UyXw 3°N � � � �{Z RECEIV 'O2O ID .Q f (� 4 Q1 C r T n y a m .0, � o W Q 76 rn SEP2521 a .to o�Z " N .6 ,0 N9 O H O Z Z+TT!! {n oo o2 'Eo 0a o6 YARIviou j,°'a; OLD KINGS HIGHWAY M E N y w y N Z N C!i N c c j ? y 7 p w W — y `O a L c d ¢ � n a O Z U} Z Q is H 0 Q w F (n N U) y< o h U) 0 Q V O `� ❑o Z r zLL N �[ F M W try Z O • Oa. to OpOj ci 60 W CO CC C �� 07 CDC ��NOw ❑Q m 0 LJ •p F- ? O X 0 Jn 2 .` =�_m Q zd Lzo rw �r Cn 0 06 ti ��a�0cn ~ •• NM A Lo �v1U fWy071 0 l Z (o0 W ' O� W wo rn� co �rn U) Z� Y W p W • W O w� Z Z a v w Z O J �p wo J M O co NQN LL U o(I mlq� 0 V O s < co M N Q m 2 O U h C 7 11J IL � H CV ��Lu1 0:5 C QQ () aUj zCD 7Zy p� aZ�t�j yC m Uaw 0 a M� �QOFwf�6 ���¢p �a'( O N Z m LLto ao2Fmu� LL U U o m �J(7o� wO�zzm N d W' woof �� L) < L��z co m OD a 0 p a J0Z) irk ! 0o� g �� � m ❑ ��zX403 m r N {n m � r a L6 0) * [� TI p V7 C U D y 7~rpJ� 2W0.g CV CD O F Qa UCLa r� q W o W o �o Z Z a U o g C> O ¢o to � I� 04 ~LLI C7 O 00 - ^ N O F rn o +n (6 a% C (o O O N a ga � ■ O } J � 0) C U ICJ Val lA d �. �UU Y d U N z w QF-❑ Cy) � O Y pWo m'�06 — 0 V U) LLI �>-L way Z zSQ� �z� 0 0 U C) Ne Z r0 O 0 00 ❑ aOm N U 2 c O c U m 0 w Z •i3 rn O JO ❑ a7 6) lCJ N.C3 O s U o O !A C O T 0 WO O ~ Lf1 IL CD ¢ d ■ co o L a r-M Lo N z w a W zal- Ww 00 Zo it 7jr-I lv;�5— powered dY THE IDEAL SOLUTION FOR: Rooftop arrays residential buildings Engineered in Germany BREAKING THE 20% EFFICIENCY BARRIER Q.ANTUM DUO Z Technology with zero gap cell layout boosts module efficiency up to 21.1%. THE MOSTTHOROUGH TESTING PROGRAMME IN THE INDUSTRY _ Q CELLS is the first solar module manufacturer to pass the most comprehen- sive quality programme in the industry: The new "Quality Controlled PV" of the independent certification institute TOV Rheinland. INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent law -light and temperature behaviour. ENDURING HIGH PERFORMANCE ` Long-term yield security with Anti LID Technology, Hot -Spot Protect and Traceable Quality Tra.Q1. EXTREME WEATHER RATING jt High-tech aluminium alloy frame, certified for 7/ high snow (b400 Pa) and wind loads (4000 Pa). 20 A RELIABLE INVESTMENT [t� �� Inclusive 25-year product warranty and 25-year hr, linear performance warranty'. See data sheet on rear for further information, OCELLS MECHANICAL SPECIFICATION Format 1879 mm x 1C45mm x 32mm (including frame) Weight 22.0kg Front Cover 3-2ram thermally pre -stressed glass with anti -reflection technology Sack Cover Composite film Frame Black anodised aluminium Cell 6 x 22 monocrystalline Q.ANTUM solar half cells Junction box 53-101 mm x 32-60 mm x 15-18 mm Protection class IP67, with bypass diodes Cable 4 mmz Solar cable; (+) >1250 mm, (-) >-1250 mm Connector Slsubli MC4; IP68 ioremm zRs.smm + xzzsom.,, + a•crwargpau�4amn �q rraa. C3 wa '- d+ B-deexpe �du + ++�waarlo[rnrxl + ELECTRICAL CHARACTERISTICS POWER CLASS 385 390 395 400 405 410 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIONS, STC' (POWER TOLERANCE +5 W 1-0 W) Power at MPP' E Short Circuit Current' Open Circuit VollageL Current at MPP PM [W] ISC [A] V_ IV] I- [A] 385 11.04 45A9 10.59 390 11.07 45.23 1065 395 11.10 45.27 1071 400 11.14 45.30 1077 405 11.17 45.34 10.83 410 11.20 45.37 10.89 Voltage at MPP V_ IV] 36.36 36,62 36,88 3713 3739 3764 Efficiency' 9 (%] z19.6 z19.9 >20.1 >20.4 z20.6 20.9 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT' Power at MPP P_ [W] 288.8 292.6 296.3 300.1 303.8 307.6 E Short Circuit Current 11C [Al 890 8.92 8.95 8.97 9.00 9.03 E Open Circuit Voltage V_ IV] 42.62 42-65 4269 4272 42.76 42.79 c i Current at MPP I- [A] 8.35 8.41 8.46 8.61 8.57 8.62 Voltage at MPP VMrr IV] 34.59 34.81 35.03 35.25 35.46 35.68 'Measurement tolerances P. t3%; Is,,: Va ±5%at STC 1000W/m2, 25±2'C, AM 1.5 according to IEC 60904-3 -1800 Wjm{ NMOT, spectrum AM 1.5 Q CELLS PERFORMANCE WARRANTY PERFORMANCE AT LOW IRRADIANCE z w _dam Atleast 98%of nominal power dur--------; _-_�_; _�--1-----i ��� �1�1uJ■ {� of nominal power up to 10 years. At - N u, Ing first year. Thereafter max. 0.5% _ a E1F f� r _-------------- degradation degradation per year. At least 93.5% u zoo r r wa __2 least 86%of nominal power up to w i i i a2 - SEP 2 5 25 rears. F w--r-----�-----------I-----3 .. 2 r 6z g i i i i All data within measurement later- r a antes. Full warranties in accordance ro 1-I I � `' $ with the warranty lermsof the JimiM 4M i00 100° ( Ahlviu,_ M QCELLS sales Organisation ofyour IRRADIANCEIWIWI HI - t� LL.kk �I"t'Yr�, respective country. OLD KIN I S YER s Typical module performance under tow irradiance conditions in comparison to STC conditions (25'C, 1000 W/m'). a TEMPERATUR E COEFFICI ENTS - Temperature Coefficient of I_ a [%/K] +0.04 Temperature Coefficient of V_ [%/K] -0.27 Temperature Coefficient of P_ y [%/K] -0.34 Nominal Module Operating Temperature NMOT ['Cl 43±3 ry PROPERTIES FOR SYSTEM DESIGN M Maximum System Voltage V,„ [VI 1000 PV module classification Class II Maximum Reverse Current Ip [A] 20 Fire Rating based on ANSI / UL 61730 C/TYPE 2 Max. Design Load, Push! Pull [Pa] 3600/2660 Permitted Module Temperature -40°C - +85'C Max. Test Load, Push/ Pull [Pa] 5400/4000 on Continuous Duty o 0 QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION eC Controlled PV-TUV aneinland: lr �lY -0 1�1�I � zM IEC 6121S.2016:IEC61730�20L6. /� 11%%%66V��JJ L�II�J O-O ,Q 6 Thisdatasnaelcamples A wnhoINE1,150380. [ E Horizontal 1940mm 1100mm 1220mm 751kg 28pallets 24pallets 32modules m QCPV Certification ongoing. ` packaging CeNlkwn holder: onn- _ Ha-ha QCELLS GmhH 3 Note: Installation instructions must be followed. See the installation and operating martual or contact our technical service department for further information on approved installation and use of this product. Made in Korea Hanwho Q CELLS Australle Pty Ltd Suite 1, Level 1,15 Blue Street. North Sydney. NSW 2060, Australia I TEL+61(0)2 9016 30331 FAX +61(012 9016 30321 EMAIL q-cells-australia@q-cei(s.com I WEE www.q-cells.cwm/au n Engineered in Germany OCELLS v a E Q v' t 0 0 Z o L LU pw V) �► en � cn _ o =fl N = o u +� s Ln a� u i cu = o GJ co ao LU V) V) apLALA CD o CD w w a 0 INVERTERS RECEIVED SEP 2, 5 ?023 r AhM%JU I t, OLD KINGS HIGHWAY -j V C � p n E -B o c y • L L V n N N 9 > O U V u ° 0 3 non v o g�a • • A O O m � � / /ti u' Y� n E — ago = 0 c cm o c c v j vE+o m' of E N o •I o o = Q �¢ a O u c m B 0 0 a G w n G y E y m C N O L pf 3 m 0 v 3 o Y c v o Q a nN m o > �W� ci �z o O cu R o B Q [! � ii E v f0 V Q N 0 Z c) L LU aQ N \ N >% Ncn 4_ O V L V \ N N > H C (U o 0 G3 co o N �j v` ii VI a EO N N D D }� O 7 N vi .ECFI V FD SEP 2 5 2023 11 E 2 O �} N OE - G--- d t; e E E �P 8::; z IFE 23'}�s Power Optimizer For Residential Installations S440 / S500 / S500B / S650B r�IVED YEAR SEP 2 5 ?02 iAhiviQU i rF OLD KING'S HIGHWAY Enabling PV power optimization at the module level I Specifically designed to work with SolarEdge residential inverters Detects abnormal PV connector behavior, preventing potential safety issues* Module -level voltage shutdown for installer and firefighter safety Superior efficiency (99.5%) Funaionalirysub}ea to inverter model and firmwareversia� solaredge.com We KV Mitigates all types of module mismatch loss, from manufacturing tolerance to partial shading Faster installations with simplified cable management and easy assembly using a single bolt ► Flexible system design for maximum space utilization I Compatible with bifacial PV modules solar -•• ECIFI III ED I Power Optimizer For Residential Installations S440 / S500 / S500B / S650B SEP 2 5 2023 fANVIOU'i rl 5440 S500 S500B S650B UNIT Rated Input DC Power"I 6S0 W Absolute Maximum #nput Voltage (Voe) 60 125 85 Vdc MPPT Operating Range 8 - 60 12.5 -105 12.5 - 85 Vdc Maximum Short Circuit Current (Isc) of Connected PV Module 14- _ 15 99,5 Adc Maximum Efficiency % Weighted Efficiency 98.6 % Overvoltage Category II OPERTION Maximum Output Current 15 Adc Maximum Output Voltage 60 1 80 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 ± 0.1 Vdc KTANnORn [[1MP11AN[E(2) EMC FCC Part 15 Class B, IEC61000-6-2, IEC61000-6-3, CISPRII, FN-55011 Safety IEC62109-1 (class II safety), UL1741 Material UL94 V-0, UV Resistant RoHS Yes Fire Safety VDE-AR-E 2100-712:2018-12 INSTALLATION SPECIFICATIONS Maximum Allowed System Votage 1000 Vdc Dimensions (W x L x H) 129 x 155 x 30 129 x 155 x 45 mm Weight 720 790 gr Input Connector MC41;1 Input Wire Length 0.1 no Output Connector MC4 Output Wire Length {+) 23, (-) 0.10 m Operating Temperature Ran elag -40 to +85 'C Protection Rating IP68 Relative Humidity 0 -100 % (1) Rated power of the module at STC Yell not exceed the Power Optimizer Rated Input DC Power. Modules with up to +5% power tolerance are allowed. (2) For details about CE compliance, see Declaration of Conformity -CE. (3) For other connector types please contact SolarEdge, 14) Power de -rat ng is applied for ambient temperatures above +05'C for S440 and SSW, and for ambient temperatures abov^_ +7S'C fcr S500B. Refer to the Power t]c'- -ers Temperature De -Rating Technical Note for details. Minimum String Length I S440, 5500 8 9 16 18 (Power Optimizers) 55006, 5fi50B 6 8 14 Maximum String Length (Power Optimizers) 25 20 50 Maximum Continuous Power per String 5700 5625 11251) 12750 W Maximum Allowed Connected Power per String (Permitted only when the power difference between strings see", See(5) 13500 15000 W is less than 2.0004Y) Parallel Strings of Different Lengths or Orientations Yes (5) It is not allowed to mix S-series and P-series Power Optimil in new installations. f6) If the inverter's rated AC power s maximum nominal power per string, then the maximum power per siring will be able to reach up to the inverters maximum input DC power Refer to Application Note: Single String Design Guidelines. M 1�6 & } 0 '2 L J O SolaEdye Texh elogies, Ltd. All rights reSF xed. S0 A.REDGF, the SolarEdge logo, OPTIMIZED BY S0LAREDGE—itra6emarI,—i gistered vadenwks or Sd.Edge Tech—logie , Inc C E RoH S All other trademarks mentioned he,einaretrademarks of Ureic respective owners_ oaten telhn,ay142M DS-DOW41-ENG_ Subjectta rhxgewideut notice. �' CF3 d mom 'Big N H '¢ cr mm c E E 25�a w yN NX 4 m =`�s"8 W O `m I. % % U_ m—' W c E ViL N m gN $ m m a Q vx 90= m�- Si g m mm-`s s v m -� b Cn� � �O X g p�paE �Ai %t� b�V tm dr a• m m m ......... E o w M u ti c £ � 4 0 m — v m c E u E z �m Jmrr 9 8eto C ow ��� itl LLui LL cc m •� P 8m�g u_ m U ��o Cc - 2 E (A Q O O La Krain x x28 1 co LL Cl Cl x ECEVED SEP 2 5 2023 s`_asgg ag§gg�F m m � tg;a� �g�me cn 8�a2' gg� W has._ mg 23'