HomeMy WebLinkAboutEngineer PlanASSESSORS MAP4,
PARCEI:��---�-
REFERENCE:�� Y;�PCA (�C�
LPT-tt- ID
MA
_
7,0
_ - -- TEST HOLE LOGS 1) The installation shall comply wM the State Emiironm#041 Code Title V and Town of
f7 Board of Health -Rely
1� SAIL EVALUATOR- 2) T'he septic em as proposed on this plan shah not be i�tallt3d until a licensed. town
■-- ""t '�"'"'-"� Installer receives approval and an installation permit *om the applicable town.
1w," Lf 1 aoto -'>" i Atf1y4 31 Prior to installation, the installer shall verify the location of utilities, sewer inverts,
,
PERCOLAnON RATE: -�
T.H.#i ELEV.
sewer lines and existing septic components prior to insUllation.
4) All gravity server piping is to be 4 Inch schedule 40 PVC at 118" per foot. The first 2
'Z v►�liti , i4
- — feet out of the distribution box shaN be level. AU piping connections to be glued.
S) This septic design plan is not to be utilized for property line determination or for any
T.H.#2 ELEV. _ other purpose other than the proposed septic system installation.
.-I'Permit valid for REPAIR OF SEPTIC SYSTEM 6) All Tide V components are to meet Title V specifications.
-ONLY, due to State and Local septic variances.
Board of Health review and approval is required for T) Parking shall be prohibited over Title V components unless components are H2O
any future additions/renovations/alterations. to loaded.
sewage facilities and/or structures/dwelling.
Yarmouth Health Department 8) nie tE Ring leaching or cesspools shall be pumped and filled with material per Title V
ROVED abandonment procedures. Leaching and cesspool(s) and contaminated soils within
the proposed SAS shall be removed and replaced with clean sand per TMe V
)-A specifications,
Name Date 9) Septic components are to be 10' from a water service line. Sewer lines crossing a
water line shall be sleeved with an appropriately sized schedule 40 PVC with ends
grouted. The water service line or the septic line can be sleeved with the sleeve beirm
a distance of 1W on both sides of grossing the lire.
*to1 e' , 10) If a garbage grinder exists in the structure, it is to be removed If the septic system is
V1%' nat designed to accommodate a garbage grinder.
• 0 11) The installer Is responsible for care of excavation around all utilities on the property
SEPTIC SYSTEM DESIGN CAi1.CULATI�NS �F,or and protecting the structural Integrity of all structures during the installlation process
of the septic system.
t 32)This plan only represents that a septic system can be installed on the property
BEDROOMS AT D GAVDAYjSDRM = 2ZOGAIjDAY meeting Title V requirements.
13) The property owner shall review design criteria to approve the total number of
SEPTIC TANK: bedrooms and design flow. Installation of the septic system as proposed and receipt
2-Z0 GALjDAY/BDRM l(2 DAYS = -i D GAMONS of payment for the design shah be deemed approval of the design criteria by the
.» property owner or agent of.
USE GALLON SEPTIC TANK( 14jTne validity of this plan shall expire with the expiration of the town installlatian perm
(GARBAGE GRINDER IS PROHIBITED) issued for this plan or the validity of this plan shall expire on the expiration of the
Certificate of Compliance issued for the installation of the proposed system on this
SOIL ABSORPTION SYSTEM:
F1 J W i Plan. �
t om' t ►, - U'V■s
SIDIEWALL
BOTTOM 1
SEPTIC SYSTEM SECTION
BEN§HMARK
TOP OF FOUNDATION
Ems•...
O , `71-/ ." 11�
IE BASE OR CXWAPACTV.D BASE
�/ — SEPTIC
f �
%j
v I . c.� __45—
1 i- - I —
3D "X A"5
WATER TEST FOR LEVELNESS
SITE AND SEWAGE PLAN
wcanoN:
IPREPARED:
-\ E "f'pill\/�
t `I
f !i� &�
SALE, _'
DATE: