HomeMy WebLinkAbout12 Ventura Way inspection reportTown of Yarmouth, MA Inspection Report Inspection: 12 Ventura Way Inspector: Debra Bruinooge Inspection Date: Sep 26, 2023 Record: Rental Certificate #BHR-23-37672 Location: 10 &12 VENTURA WAY, SOUTH YARMOUTH, MA 2664 Applicant: MICHAEL A WILLIAMS Rental Inspection Overall Result: Pass Overall Remarks: Met with owner Michael Williams as tenant was not home but we had permission to enter. Overall house was neat and organized. Please see below for specific issues. 2024 inspection will be required. Checklist: 1. Number of Bedrooms Result: Pass Remarks: #1 10.705 X 14.405 #2 11.455 X 13.025 2. Maximum Occupancy: Based on septic system capacity, number of bedrooms and bedroom square footage Result: Pass Remarks: 4 3. Basement Result: Pass Remarks: Unfinished. Many items in basement that could lead to harborage-recommend a clean out. 4. Electrical Panel Result: Fail Remarks: Electrical panel must be cleared to allow emergency access. 5. Copy of Tenant's Legal Rights have been issued to tenant. Result: Pass 105CMR 410.00 0Minimum Standards of Fitness for Human Habitation (State Sanitary Code: Chapter II) Result: Pass 410.100 Kitchen Facilities * Result: Pass 410.110 Bathroom Facilities : Sinks, Toilets, Tubs & Showers * Result: Pass 410.120 Approved Toilets * Result: Pass 410.130 Water supply Potable Water/Sanitary Drainage Result: Pass 410.140 Plumbing Connections * Result: Pass 410.150 Hot Water 110-130 °F for faucets & 110-120 °F for bathtubs a & showers Result: Pass 410.160 Heating Systems * Result: Pass 410.170 Venting * Result: Pass 410.180 Temperature Requirements Owner shall proved heat in every habitable room & every room containing a toilet, shower or bathtub from September 15th through May 31st. 64° from 11:01 pm to 6:59 am 68° from 7 am to 11:00 pm Result: Pass 410.200 Provision and Metering of Electrical or Gas * Result: Pass 410.210 Provision of Oil * Result: Skip 410.220 Natural and Mechanical Ventilation * Result: Pass 410.230 Owner's Laundering Responsibilities If owner provides bed linens, towels, pillows or mattress Result: Skip 410.235 Owner's Installation, Maintenance and Repair Responsibilities * Result: Fail Remarks: Drawers on left side of vanity do not close-repair/replace Light fixture in bathroom missing bulb cover-replace Exhaust fan in bathroom works but is missing a bulb and the plastic piece that covers it-replace bulb and covering Water tank overflow pipe appears to be leaking-a licensed professional should repair 410.240 Occupant's Installation and Maintenance Responsibilities * Result: Pass 410.250 Asbestos-containing Material * Result: Pass 410.260 Means of Egress * Result: Pass 410.270 Locks * Result: Pass 410.300 Electrical Supply & Illumination * Result: Pass 410.310 Auxiliary Emergency Lighting Systems & Exit Signs For properties with 10 or more units Result: Skip 410.320 Electrical Service Temporary Wiring, Amperage Result: Pass 410.330 Smoke Detector and Carbon Monoxide Alarms * Result: Pass 410.400 Owner/Manager Contact Information and Notice of Occupants' Legal Rights and Responsibilities Contact information and postings inside and outside of home Result: Pass 410.410 Building Identification * Result: Pass 410.420 Habitability Requirements Result: Pass 410.430 Natural Light and Obstructions * Result: Pass 410.470 Lead-based Paint Hazards in Residence * Result: Pass 410.500 Owner Responsibility to Maintain Building & Structural Elements * Result: Pass 410.510 Occupant 's Responsibility Regarding Building and Structural Elements * Result: Pass 410.520 Protective Railings and Walls * Result: Pass 410.530 Weather-tight elements * Result: Pass 410.540 Installation of Screens * Result: Fail Remarks: A) The owner shall provide and install screens for exterior openable windows so that: (1) They are in place during the period from April 1st through October 31st in each year; (2) They are no less than 16 mesh per square inch; (3) They cover that part of the window designed to be opened, except in double hung windows where half screens shall meet this requirement; and (4) They are tight fitting and prevent the entrance of pests. (B) Expandable, temporary screens shall not satisfy the requirements of 105 CMR 410.540(A). (C) The owner shall provide and install screen doors for all doorways opening directly to the outside from any dwelling unit or rooming unit where the screen doors will be permitted to slide to the side or open in an outward direction so that: (1) They are in place during the period from April 1st through October 31st in each year; (2) They are 16 mesh per square inch; (3) They are equipped with a self- closing device except where the screen is designed to open to the side; and (4) They are tight fitting and prevent the entrance of pests. 410.550 Elimination of Pests Owners & Occupants are responsible for the control & elimination of pests Result: Pass Remarks: None observed 410.560 Refuse * Result: Pass Remarks: Per lease, tenant responsible for trash and yard work. Yard requires clean up. 410.570 Maintenance of Areas in a Sanitary and Safe Condition * Result: Pass 410.630 Conditions Deemed to Endanger or Materially Impair Health and Safety One or more of the violations cited on this report may materially impair the health or safety and/or well-being of any person(s) occupying the premises Result: Pass This inspection report is signed and certified under the pains and penalties of perjury. Inspector's signature and date Result: Pass Remarks: Debra Bruinooge 09/27/2023