Loading...
HomeMy WebLinkAboutEngineer PlanTOF=12.9'+- PROVIDE EXTENSION RISER FINISHED GRADE OVER INLET COVER TO WITHIN F.G. OVER @ FOUNDATION - 12.5'± 6" OF F.G. & MIDDLE TO F.G. TANK EL.= 12.1'± DISCONNECT EL.=10,83'� V MIN. ACCESS OF 2) COVER (TYP. JUNCTION Box PROPOSED 4" 21" 21" 30' SCHEDULE 40 PVC 2" DROP MIN. MIN. SLOPE @ 1%n 6" 3" 3" DROP MAX. 3" 9" 5, `- o 14" r )NNECTIOI L *10.3'± 9 75' 48" LIQUID DEPTH '.SHGW @ EL.=6.27'± 1000 GALS. 500 GALS. `-PROVIDE 30'0 FINISH GRADE OVER D-BOX = 13.1'± EXTENSION RISER OVER OUTLET COVER TO F.G. REMOVABLE WATERTIGHT RISER TO WITHIN 6" OF FINISHED GRADE 5" DIA. OUTLET(S) 9" MIN. 36"MAX. 2" PVC FORCE MAIN 9" MIN. TO DISTRIBUTION BOX 36"MAX. PROVIDE WATER -TIGHT SEAL (TYP. BOTH INVERTS) 4" PVC 2" PVC TE _ TO S SOUT 9.50 DIMENSION AS PER ACME-SHOREY TANK ITEM NO. 1 1.60' STPC1530 10. 2' offset to fnd EL.-5.16'-� 22" ZABEL FILTER MODEL # A1801-4x22 6" CRUSHED STONE (GAS BAFFLE ON BOTTOM) OVER MECHANICALLY COMPACTED BASE PROPOSED 1000/500 ''-10 T` ": ' `�OMPX PTIC TANK / PUMP CHAMBER 5'-8" *CONTRACTOR TO VERIFY EXISTINtLENGTH 10'-6" WIDTH 5'-8" DEPTH : ALL TEES TO BE LINED UP ELEVATION PRIOR TO ANY WORK & DIRECTLY UNDER CENTER NOTIFY ENGINEER IF DIFFERENT. NOT TO SCALE OF RISER OPENINGS . r r r J:(� r U.P4145/4 p`)�, ,'!, ,. Go�`G� r j Q o / cos r / A z Z G� a L.P. U cq /tea s / J. lb / M r i r / r / i U,P00 MAP 22 LOT 193 10,817± S.F. x12.7 S� HC- oa x 12.5 s PROP.1,000/500-GAL. 2-COMPARTMENT SEPTIC TANK / PUMP CHAMBER - EXISTING DWELLING REMOVE UNSUITABLE MATERIAL DOWN TO "C-2" SOIL & REPLACE w/ CLEAN COARSE SAND PER 310 CMR 255(3) PROPOSED DISTRIBUTION BOX s a� #76 EXISTING III, ! 2-BEDROOM I �a DWELLING j I , a (FULL BASEMENT) I 12-,� !, 1 o i 11 (SLAB) �1� TOF=12.9'±� I Ir x12.5 I II -HC-2 = # i I N i 0 to 6) O � ECK . 6" 12" MIN. 11.43' 6" CRUSHED STONE OVER MECHANICALLY COMPACTED BASE 5 OUTLET DISTRIBUTION BOX TO BE INSTALLED ON A LEVEL STABLE BASE. FIRST TWO FEET OF OUTLET PIPES TO BE LAID LEVEL. CROSS SECTION VIEW NOT TO SCALE INSTALL 1-1/4" PVC TO HOUSE. JOINTS TO BE MADE WATERTIGHT. WIRE PUMP AND FLOATS TO SIMPLEX CONTROL PANEL No. 1-CC2 NEMA-1 MFG. HOOVER INSTRUMENTS NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED CONNECTORS SUPPORTED BY 1-1/4" PVC CONDUIT, JOINTS TO BE MADE WATERTIGHT- 4" SCHEDULE 40 PVC MIN SLOPE 1% I 11.30' 36" MIN. FINISH GRADE OVER CHAMBERS = 13.1' - 13.0 SLOPE @ 2% MIN. OVER SYSTEM 3/4" TO 1-1/2" DOUBLE WASHED STONE TO CROWN OF PIPE TOP OF SAS = 12.13' BREAKOUT EL = 1 1.80' ►� O ff-oc�cce�;" it 3.0' I- - - 6.0' (TYP)----------_ 30.0' Z0.30' GROUND WATER ELEV= LC-6 CHAMBERS TYPICAL CHAMBER PROFILE NOTE: PUMP MUST BE EQUIPPED WITH A HIGH LEVEL ALARM LOCATED IN THE BUILDING SERVED WHICH IS POWERED BY A ' t CIRCUIT SEPARATE FROM THE CIRCUIT TO THE PUMP. �..i HOISTING CABLE 7 x 19 STAINLESS STEEL 1/8" DIA. / 1,760 LB. STRENGTHI QCV f. 2" SCH. 40 TEE w/ CLEAN -OUT CAP 2" BALL VALVE w/ UNIONS SCH. 80 PVC ; GEORGE FISHER CO. MODEL NO. 560 i ~-2" SCH. 40 TO D-BOX I 'r� ! 1/4" WEEP HOLE IN DISCHARGE PIPE ` i / I,_PUMP ON / 2" BALL CHECK VALVE SCH. 80 PVC 100 / PUMP P.S.I. FLOWMATIC MODEL No. 2085 (2) WIDE ANGLE CONTROL FLOATS C) o (BARNES 073618) o 2" SCH. 40 PVC DISCHARGE PIPE 1: PUMP ON/OFF 120 ACTIVATION BARNES SE411 PUMP 0.4 H.P., 2: ALARM ACTIVATION 115 V, 2" DISCHARGE PASSING 1-1/2" SOLIDS OR EQUAL 1000/500 GALLON SEPTIC' T' PUMP CHAMBER DETAIL NOT TO SCALE Benchmark Deck Comer Elev. = 12.89' N.A.V.D. 88 EXISTING GARAGE (3 30 0' =_-- Nor i TPA 0 _. / TP 4 i x_ 11x3'- 11x3' 13 i - PROPOSED 4" SCH. 40 PVC VENT; 5) EXACT LOCATION PER OWNER 12 (4 \ PROPOSED FOUR (4) LC-6 LEACHING CHAMBERS w/ STONE i MAP 23 LOT 16 1, -32.2' i -10 SHED MAP 22 - - LOT 194 v TIP 2 Tfi PROP. 40 MIL. IMPERVIOUS,' GEOMEMBRANE LINER; TOP EL.=11.8; BOT. EL.=6.8' MAP 23 EXISTING CESSPOOL TO BE LOT 2 PUMPED; FILLED wl SAND & 8- ABANDONED TYPOF2) i-7 SITE PLAN SCALE: 1" = 10' 6.27' (adj.) 5.00' MIN. REQ'D 4.03' MIN. PROP. NOT TO SCALE PROP. VENT WITH CHARCOAL FILTER TO ABOVE GRADE 1. UNLESS OTHERWISE NOTED, ALL SYSTEM COMPONENTS AND CONSTRUCTION 40 M" �C" hABRA^' ' '"IR Tom`~ ' ' ` `J a 11 8' {MIN) METHODS SHALL BE IN ACCORDANCE WITH TITLE 5 OF THE STATE ENVIRONMENTAL CODE AND ANY APPLICABLE LOCAL RULES. 2" OF 118" TO 1/2" DOUBLE WASHED r STONE OR GEOTEXTILE FILTER FABRIC 2. ANY CHANGES TO THIS PLAN MUST BE APPROVED BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. PLACE RISER ON ALL 3. 4" SCHEDULE 40 PVC PIPE WITH WATER TIGHT JOINTS SHALL BE USED IN DISPOSAL PIPED INLETS TO SYSTEM UNLESS OTHERWISE NOTED. WITHIN 6" OF F.G. _� 4. TO PREVENT BREAKOUT, THE PROPOSED FINISHED GRADE SHALL NOT BE LESS THAN ELEVATION = 11.80' FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE SAS. UNLESS A 40 MIL GEOMEMBRANE LINER IS PLACE AT LEAST FIVE FEET FROM S.A.S. AND THE TOP OF O THE LINER IS NOT LESS THAN THE BREAKOUT ELEVATION. c o 5. SLOPE ALL SOLID PIPE AT 1.0% MINIMUM. 6. THIS SYSTEM IS NOT DESIGNED FOR A GARBAGE DISPOSAL. CD o o 7. LOCAL BOARD OF HEALTH AND DESIGN ENGINEER TO BE NOTIFIED PRIOR TO BACK 00 00 FILLING WHEN SYSTEM IS NEARLY COMPLETE AND READY FOR INSPECTION. SYSTEM IS oO = cz�)o ; NOT TO BE BACK FILLED WITHOUT FIRST OBTAINING APPROVAL FROM BOARD OF HEALTH -- AND DESIGN ENGINEER. --5.0' 3.0' 3 0` 3.0' (min.) 8. ELEVATIONS BASED ON N.A.V.D. 88 DATUM. SEE BENCHMARK LOCATION AND ELEVATION (TYP) SHOWN ON PLAN. 9. CONTRACTOR SHALL VERIFY ALL UTILITY LOCATIONS PRIOR TO CONSTRUCTION 9.0' THROUGH DIG -SAFE AT LEAST 72 HOURS PRIOR TO COMMENCING WORK ON SITE AT CHAMBER END VIEW 1-888-DIG-SAFE AND ANY OTHER APPLICABLE AGENCIES. REPORT ANY DISCREPANCIES LINER TO BE INSTALLED PER PLAN TO THE DESIGN ENGINEER. 40 MIL GEOMEMBRANE LINER, 10- ALL JOINTS WHERE PIPE ENTERS AND EXITS CONC. STRUCTURES SHALL BE MADE WATERTIGHT. BOTTOM ELEV. = 6.6 (MAX.) 11. NO DETERMINATION HAS BEEN MADE AS TO COMPLIANCE WITH DEEDED OR ZONING _ REGULATIONS. OWNER/APPLICANT IS TO OBTAIN SUCH DETERMINATION FROM �f TEST i!"" I T DAT R APPROPRIATE AUTHORITY. - I I 12. ALL SEPTIC SYSTEM COMPONENTS SHALL WITHSTAND H-10 LOADING UNLESS LOCATED l�= =--1-) INSPECTOR: Barry Lewis (BOH) UNDER MORE THAN 3 FEET OF COVER OR LOCATED UNDER PAVEMENT, DRIVES, OR jL EVALUATOR: Michael Pimentel, EIT, CSE TRAVELED WAYS IN WHICH CASE THEY SHALL WITHSTAND H-20 LOADING. a f C.S.E. APPROVAL DATE: Oct. 27, 1999 13. DOUBLE WASHED CRUSHED STONE SHALL BE FREE OF ALL DIRT, DUST AND FINES. { j I DATE: August 24, 2023 14 WHERE REQUIRED CONTRACTOR SHALL REMOVE ALL LOAM, SUBSOIL AND UNSUITABLE �. TEST PIT #: 1 & 2 MATERIAL IN AREA BENEATH AND FOR 5 FT. ON ALL SIDES OF LEACHING FACILITY. -- - _ REPLACE ALL UNSUITABLE MATERIAL WITH CLEAN COARSE SAND FREE FROM CLAY, ELEV TOP = 9.20' FINES OR OTHER UNSUITABLE MATERIAL IN ACCORDANCE WITH 310 CMR 15.255(3). < � - ELEV WATER = 6.27t 15. CONTRACTOR SHALL NOTIFY DESIGN ENGINEER OF ANY DISCREPANCIES FOUND IN PERC RATE -_ SITE CONDITIONS FROM THOSE SHOWN PRIOR TO CONTINUATION OF WORK. LOCUS !r'� 16. PROPOSED SAS IS LOCATED WITHIN: DEPTH OF PERC = f` ASSESSOR'S MAP 22 LOT 193 TEXTURAL CLASS: I OWNER OF RECORD: BERNICE STURNIOLO, TRUSTEE ADDRESS: 7 RHODES STREET SAUGUS MA 01906 NOTES: 1 1.) MAGNETIC MARKING TAPE SHALL BE PLACED ALONG THE TOP EDGE OF EACH SEPTIC SYSTEM COMPONFNT. LOCUS PLAN 2.) CONTRACTOR SHALL VERIFY SOIL CONDITIONS IN THE LOCATION OF THE PROPOSED LEACHING FACILITY TO ENSURE SCALE.- 1" = 1000' CONSISTENCY WITH TEST PIT DATA SHOWN ON THIS PLAN. REPORT TO ENGINEER AND LOCAL BOARD OF HEALTH IF SOILS ARE NOT CONSISTENT WITH TEST PIT DATA. DESIGN DATA 3.) PROPERTY IS NOT LOCATED WITHIN A DEP APPROVED ZONE IL 4.) SWING TIES SHOWN ON THIS PLAN ARE PROVIDED ONLY AS A NUMBER OF BEDROOMS (EXISTING) 2 COURTESY FOR THE INSTALLER. INSTALLER SHALL VERIFY SWING NUMBER OF BEDROOMS (DESIGN) 2 TIE MEASUREMENTS IN THE FIELD PRIOR TO INSTALLING THE SYSTEM. CONTRACTOR SHALL NOTIFY ENGINEER IF DESIGN FLOW 110 GAUDAY/BEDROOM MEASUREMENTS APPEAR TO BE INCORRECT. TOTAL DESIGN FLOW 220 GAUDAY 5.) ELECTRIC LINES FROM PUMP CHAMBER TO CONTROL PANEL AT THE BUILDING SHALL BE INSTALLED BY THE CONTRACTOR. DESIGN FLOW x 200% = 440 GAUDAY ELECTRIC LINES TO BE ROUTED FROM PUMP CHAMBER TO USE PROPOSED 1000/500 GALLON SEPTIC TANK / PUMP CHAMBER BUILDING WITH THE LEAST AMOUNT OF DISTURBANCE TO THE PROPERTY AS POSSIBLE. 6.) INSTALLER TO PROVIDE ADEQUATE DEWATERING OPERATIONS IF NECESSARY AND OBTAIN APPROVAL FROM TOWN AS REQUIRED. Yarmouth Health Department ROVED Na �� Date MAP 23 LOT 3 SWING -TIES DESCRIPTION HC-1 HC-2 SEPTIC TANK COVER IN (1) 16.6' 22.0' SEPTIC TANK COVER OUT (2) 13.3' 28.1' CORNER OF STONE (3) 20.6' 35.6' CORNER OF STONE (4) 29.6' 42.0' CORNER OF STONE (5) 41.9' 32.0' CORNER OF STONE (6) 36.2' 1 23.1' Wild Fill AdjtLSted a�35.2" 54" 9.20' 4.70' Standing @ 76" __ 7" I ? 8T Medium Sand C 2.5Y 616 120" -0.80' TEST PIT DATA FEMA FLOOD ZONE X (<500) COMMUNITY PANEL # 25001 CO588J 17. DEED REFERENCE: L.C.C. #183376 18, PLAN REFERENCE: L.C. PLAN NO. 11435-A 19. ALL DISTURBED AREAS SHALL BE RESTORED TO ORIGINAL CONDITION. 20. PROPERTY LINE INFORMATION IS ONLY APPROXIMATE. THIS PLAN IS TO BE USED ONLY FOR SEPTIC SYSTEM UPGRADE. JC ENGINEERING WILL NOT ASSUME ANY LIABILITY FOR USES OF THIS PLAN OTHER THAN ITS INTENDED PURPOSE. 21. OWNER / APPLICANT / CONTRACTOR SHALL BE RESPONSIBLE TO OBTAIN ANY AND ALL REQUIRED PERMITS AND APPROVALS FOR THIS PROJECT. 22. IN ACCORDANCE WITH 310 CMR 15.401-15.406, THE FOLLOWING LOCAL UPGRADE APPROVAL IS REQUESTED FROM 310 CMR 15.212(1): 1.) A 0.97' WAIVER (5.00' - 4.03) FOR THE SEPARATION BETWEEN THE SAS AND ESHGW. 50xO' INSPECTOR: Barry Lewis (BOH) EVALUATOR: Michael Pimentel, EIT, CSE 50 C.S.E. APPROVAL DATE: Oct. 27, 1999 50 DATE: August 24, 2023 50 INSTALL (4) LC-6 LEACHING CHAMBERS W/ STONE TEST PIT #: 3 & 4 O I W SIDEWALL CAPACITY ELEV TOP = 11.30' ~- ELEV WATER = 6.20'* + (LENGTH + WIDTH) (2 SIDES) (1 HIGH) (0.74 GPD/S.F.) = GAUDAY (30.0' + 9.0') (2) (1') (0.74 GPD/ S.F.) = 57.7 GAUDAY GAS PERC RATE - < 2 min./inch -- BOTTOM CAPACITY DEPTH OF PERC = 54" - 72" (LENGTH x WIDTH) (0.74 GPD/S.F.) = GAUDAY (30.0' x 9.0') (0.74 GPD/S.F.) = 199.8 GAUDAY TEXTURAL CLASS: TOTALS: Oil 11 30' TOTAL NUMBER OF CHAMBERS 4 TOTAL LEACHING AREA 348.0 SQ.FT. 6" TOTAL LEACHING CAPACITY 257.5 GAL./DAY B 24" DOSING & STORAGE REQUIREMENTS C-1 DESIGN FLOW: 220 GPD DOSING REQUIRED: 4 CYCLES / DAY 54" 220 GPD / 4 = 55 GALS/CYCLE Perc 61.2' DISTANCE REQUIRED BETWEEN PUMP 72 ON AND PUMP OFF FLOATS: 55 GALS/CYCLE - 125 GAUFT = 0.44 FT/CYCLE C-2 (USE 0.50' TO PROVIDE FOR BACKFLOW) STORAGE REQUIRED ABOVE WORKING LEVEL- 220 GAL. STORAGE PROVIDED ABOVE WORKING LEVEL: 313 GAL. BUOYANCY CALCULATIONS 120" 10.80' 9.30' 6.80' 620' 5.30' ?.80, PROP. 1,000 / 500 GAL. 2-COMPART. H-10 SEPTIC TANK/PUMP CHAMBER 1.30' HIGH GROUNDWATER EL.= 6.27' TOP OF SEPTIC TANK EL. = 10.83' BOTTOM OF SEPTIC TANK EL. = 5.16' WATER DISPLACED = (6.27' - 5.16') x 10.5' x 5.67' = 66 C.F. 'BASED ON THE CAPE COD WEIGHT OF DISPLACED WATER = 66 C.F. x 62.4 LB/C.F. = 4,118 LBS COMMISSION METHOD WEIGHT OF 1,000 / 500 GAL. 2-COMPARTMENT H-10 TANK = 13,000 LBS INDEX WELL: MIW-29 SOIL COVER = (12.1' - 10.83') x 10.5' x 5.67' = 76 C.F. WATER -LEVEL RANGE ZONE- B WATER DEPTH READING: 9.OT WEIGHT OF SOIL ABOVE TANK = 76 C.F. x 110 LB/C.F. = 8,360 LBS WATER DEPTH READING DATE: AUG. 2023 13,000 + 8,360 = 21,360 LBS > 4,118 LBS; THEREFORE ACCEPTABLE WATER -LEVEL ADJUSTMENT: 3.4' (40.8") Fill Loamy Sand 10Yr 5/6 Fine Sandy Loam 2.5Y 6/6 (TP's 3 & 4) Adjusted c�a 61.2" - Medium Sand 2.5Y 6/6 „Standing@102" _� 0 t-. EXISTING SPOT GRADE EXISTING CONTOUR PROPOSED CONTOUR PROPOSED SPOT GRAI EXISTING OVER -HEAD EXISTING WATER LINE EXISTING GAS LINE PROP. 2" SOLID SCHEDULE 40 PVC FORCE MAIN TEST PIT LOCATION PROP. 1000/500 GAL. H-10 SEPTIC TANK/PUMP CHAMBER PROPOSED 4" SOLID SCHEDULE 40 PVC PIPE PROPOSED DISTRIBUTION BOX PROPOSED LC-6 LEACHING CHAMBER REV. DATE BY APP'D. DESCRIPTION PROPOSED SEPTIC SYSTEM UPGRADE 4PtiOF MAssPREPARED FOR: JOHN L. ��, ROBERT B. OUR CO., INC. CHURCHILL JR. CI to NO. 066 LOCATED AT 17, 76 PINE CONE DRIVE WEST YARMOUTH, MA 02673 SCALE: 1 INCH = 10 FT. DATE: SEPTEMBER 16, 2023 OF 0 5 10 20 40 FEET JpHN L. PREPARED PREPARED BY: c"" CIVIL JR" H JC ENGINEERING, INC. "° 4.4 2854 CRANBERRY HIGHWAY EAST WAREHAM, MA 02538 508.273.0377 j Drawn By: MCP Designed By: MCP Checked By: JLC JOB No. 7249