HomeMy WebLinkAbout2023 Sign off Transmittal - Breezeway into a year round room TOWN OF YARMOUTH
HEALTH DEPARTMENT
�• '� PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET
To he completed by Applicant:
Building Site Location: 5 1 % Q,>r
Proposed Improvement: c\ivoAAlt F x / CA. c
S "mot y / cfA( 40 e a d(AAA—CI
Applicant: t<Q, }i 1d / Tel. No.:fo 0` 7 `f O 7 Zv
Address: \(.9C) � Uvvi r� (c- Date Filed: 2- /e le"`Z;
**/fyou would like e-mail notification of sign off,please provide e-mail address:
Owner Name: (,d S La
y
Owner Address: ►�ti✓tt 4. / 51 Owner Tel. No.: 3 a--4t1`} )S-
RESIDENTIAL AND/OR COMMERCIAL BUILDING
HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements
For Septage Disposal and other Public Health Activities.
Please submit three (3) copies of plans, to include:
(1.) Site Plan showing existing buildings, water line location,
and septic system location;
(2.) Floor plan labeling ALL rooms within building
(all existing and proposed) —
Note: Floor plans not required for decks, sheds, windows, roofing;
(3.) If necessary, Title 5 application signed by licensed installer
with fee.
REVIEWED BY: ✓ DATE: 7'A.
PLEASE NOTE
COMMENTS/CONDITIONS:
NEW (3)
2x12 SPF
EXISTING
2x6
ADD 2x3
NOTCH FOR 2x4
• RIDGE
AND HANGER
• PLATE
R6.5/IN
FOAM TOTAL Rt49
REMOVE
EXISTING CEILING
HANGER FOR 2x3
SHORE ROOF & REMOVE WALL
NEW 2x6 CONTINUOUS HEADER
NEW 2x4 WALL R6.5/IN FOAM
INSULATION R=f22
PAD SLAB FLUSH W/ EXISTING HOUSE
ALLOW FOR RADIANT HEAT
SECTION
Scale: 1/4" =1'- 0"
EXISTING ELEVATION
Scale: 1/4" =1'- 0"
EQUAL
w
t12'-18"
(.M
Sm
NEW (3) 2X12 RIDGE
OUTSWING DOOR REQUIRES
3'-0"x3'-0" MIN PLATFORM
W/ 1 J" MAX STEP FROM
TOP OF THRESHOLD. OTHER
STEPS 8" RISER MAX 9" TREAD MIN
11'-38" (2) 2x6 HEADER CONT. V.I.F.
REMOVE EXISTING DOOR/TRIM
NEW 2/8xi 20 MIN DOOR t6
FROM CORNER. MOVE/REPLACE
STAIRS AS REQUIRED. SEE DOOR
NOTES. P&M WALL W/5/8" TYPE
X GYPSUM (MATCHING EXISTING)
INSULATE FRAMING
,
1" 2'-10" 2'-21„ 1 2'-2 " 1 2'-2 " 8
2 I 1'-1' $�� 4 5„
F $
rJJ JJJ JJ J J JJX
t11'-10"
FRONT WALL
Scale: 1/2" = V- 0"
NEW WINDOWS:
NEW DOORS:
FRONT ANDERSEN (3) TW2042
A
2/8x6/8
9 LIGHT EXTERIOR OUTSWING
R.0.2'-2 A x 4'-5" TEMPERED
B
2/6x6/8
12 LIGHT INTERIOR POCKET
REAR ANDERSEN (2) TW2442
USE FULL
SLAT 2/6 FRAME
R.0.2'-6 i x 4'-5" TEMPERED
C
2/8x6/8
9 LIGHT EXTERIOR OUTSWING
D
2/8x6/8
6 PANEL 20 MINUTE EXTERIOR
NOTES;
1) EXTERIOR DOORS A & C BORED FOR
DEAD BOLT AND LATCH. FULLY WEATHER
STRIPPED. STANDARD THRESHOLD
2) DOOR B POCKET DOOR LATCH VERIFY W/
GENERAL CONTRACTOR
3) DOOR D SINGLE BORE FOR PASSAGE
LATCH. FULLY WEATHER STRIPPED. LOW
PROFILE (ADA) THRESHOLD)
NEW ELEVATION
Scale: 1/4" = F- 0"
NOTES
1) SHORE ROOF AT FRONT WALL AND
REMOVE WALL TO TOP OF NEW HEADER.
2) TOP OF HEADER 0 6-10 J" + 7
FROM TOP OF NEW FLOOR.
2A) NEW HEADER (2) 2x6 SPF
3) NEW FLOOR; COVER SLAB W/6 MILL
POLYETHYLENE FURR EXISTING SLAB W/
2x P.T. SLEEPERS SHIMMED TO MATCH
EXISTING HOUSE. USE J" PLYWOOD
SUBFLOOR.
3A) OPTIONAL FILL FURRED BAYS W/
LOSE FILL INSULATION OR FITTED RIGID
BOARD INSULATION.
4) REAR WALL SAME AS 1-2A ABOVE.
[REC,EIVED
td U 9 2023
HEALTH DEPT.
ZH OF MASS9cyG
THOMAS M. N
CALLERY
CIVIL C/)
No. 33440
CG/si f-
/ONPL EN
REVIEWED
By Thomas M. Callery, P.E. at 9:55 am, Feb 07, 2023
Q
y O
U N
0 h
0 n- O
01) f
Ln
U Q
QLL-o� I
O
�z=�0
Z> o 0:� cD
Owo<
UY I -
Q
Z
0 _
F-- I---
W
U z0
0 }- j
� Q �
Q
z
ry >- [y _
LLJ = -D !--
�Q~0
0 U 00 Cn
W r
-1 N
Q O
U N
V
L0
m N
U
d
O
r
m
z
Q
a:
0
to