Loading...
HomeMy WebLinkAbout2023 Sign off Transmittal - Breezeway into a year round room TOWN OF YARMOUTH HEALTH DEPARTMENT �• '� PERMIT APPLICATION SIGN OFF TRANSMITTAL SHEET To he completed by Applicant: Building Site Location: 5 1 % Q,>r Proposed Improvement: c\ivoAAlt F x / CA. c S "mot y / cfA( 40 e a d(AAA—CI Applicant: t<Q, }i 1d / Tel. No.:fo 0` 7 `f O 7 Zv Address: \(.9C) � Uvvi r� (c- Date Filed: 2- /e le"`Z; **/fyou would like e-mail notification of sign off,please provide e-mail address: Owner Name: (,d S La y Owner Address: ►�ti✓tt 4. / 51 Owner Tel. No.: 3 a--4t1`} )S- RESIDENTIAL AND/OR COMMERCIAL BUILDING HEALTH DEPARTMENT: Determines Compliance to State and Town Regulations; i.e., Requirements For Septage Disposal and other Public Health Activities. Please submit three (3) copies of plans, to include: (1.) Site Plan showing existing buildings, water line location, and septic system location; (2.) Floor plan labeling ALL rooms within building (all existing and proposed) — Note: Floor plans not required for decks, sheds, windows, roofing; (3.) If necessary, Title 5 application signed by licensed installer with fee. REVIEWED BY: ✓ DATE: 7'A. PLEASE NOTE COMMENTS/CONDITIONS: NEW (3) 2x12 SPF EXISTING 2x6 ADD 2x3 NOTCH FOR 2x4 • RIDGE AND HANGER • PLATE R6.5/IN FOAM TOTAL Rt49 REMOVE EXISTING CEILING HANGER FOR 2x3 SHORE ROOF & REMOVE WALL NEW 2x6 CONTINUOUS HEADER NEW 2x4 WALL R6.5/IN FOAM INSULATION R=f22 PAD SLAB FLUSH W/ EXISTING HOUSE ALLOW FOR RADIANT HEAT SECTION Scale: 1/4" =1'- 0" EXISTING ELEVATION Scale: 1/4" =1'- 0" EQUAL w t12'-18" (.M Sm NEW (3) 2X12 RIDGE OUTSWING DOOR REQUIRES 3'-0"x3'-0" MIN PLATFORM W/ 1 J" MAX STEP FROM TOP OF THRESHOLD. OTHER STEPS 8" RISER MAX 9" TREAD MIN 11'-38" (2) 2x6 HEADER CONT. V.I.F. REMOVE EXISTING DOOR/TRIM NEW 2/8xi 20 MIN DOOR t6 FROM CORNER. MOVE/REPLACE STAIRS AS REQUIRED. SEE DOOR NOTES. P&M WALL W/5/8" TYPE X GYPSUM (MATCHING EXISTING) INSULATE FRAMING , 1" 2'-10" 2'-21„ 1 2'-2 " 1 2'-2 " 8 2 I 1'-1' $�� 4 5„ F $ rJJ JJJ JJ J J JJX t11'-10" FRONT WALL Scale: 1/2" = V- 0" NEW WINDOWS: NEW DOORS: FRONT ANDERSEN (3) TW2042 A 2/8x6/8 9 LIGHT EXTERIOR OUTSWING R.0.2'-2 A x 4'-5" TEMPERED B 2/6x6/8 12 LIGHT INTERIOR POCKET REAR ANDERSEN (2) TW2442 USE FULL SLAT 2/6 FRAME R.0.2'-6 i x 4'-5" TEMPERED C 2/8x6/8 9 LIGHT EXTERIOR OUTSWING D 2/8x6/8 6 PANEL 20 MINUTE EXTERIOR NOTES; 1) EXTERIOR DOORS A & C BORED FOR DEAD BOLT AND LATCH. FULLY WEATHER STRIPPED. STANDARD THRESHOLD 2) DOOR B POCKET DOOR LATCH VERIFY W/ GENERAL CONTRACTOR 3) DOOR D SINGLE BORE FOR PASSAGE LATCH. FULLY WEATHER STRIPPED. LOW PROFILE (ADA) THRESHOLD) NEW ELEVATION Scale: 1/4" = F- 0" NOTES 1) SHORE ROOF AT FRONT WALL AND REMOVE WALL TO TOP OF NEW HEADER. 2) TOP OF HEADER 0 6-10 J" + 7 FROM TOP OF NEW FLOOR. 2A) NEW HEADER (2) 2x6 SPF 3) NEW FLOOR; COVER SLAB W/6 MILL POLYETHYLENE FURR EXISTING SLAB W/ 2x P.T. SLEEPERS SHIMMED TO MATCH EXISTING HOUSE. USE J" PLYWOOD SUBFLOOR. 3A) OPTIONAL FILL FURRED BAYS W/ LOSE FILL INSULATION OR FITTED RIGID BOARD INSULATION. 4) REAR WALL SAME AS 1-2A ABOVE. [REC,EIVED td U 9 2023 HEALTH DEPT. ZH OF MASS9cyG THOMAS M. N CALLERY CIVIL C/) No. 33440 CG/si f- /ONPL EN REVIEWED By Thomas M. Callery, P.E. at 9:55 am, Feb 07, 2023 Q y O U N 0 h 0 n- O 01) f Ln U Q QLL-o� I O �z=�0 Z> o 0:� cD Owo< UY I - Q Z 0 _ F-- I--- W U z0 0 }- j � Q � Q z ry >- [y _ LLJ = -D !-- �Q~0 0 U 00 Cn W r -1 N Q O U N V L0 m N U d O r m z Q a: 0 to