10 Gaslight Dr plan
WIND DESIGN: L = 141; W= 12.5'; L/W = 1.12 REAR W 4/14 = 0.29% NAIL SHEAR NAIL 4" O.C. EDGE RIGHT & LEFT CONT GIRT HRADER FOR WIND. (4) 8" TIMBER LOCK FRT TO SIDE HEADER. BEND (1) MSTA14 AROUND CORNER USE 10' SHEETS VERTICAL (3) EDGE ROW STAGGERED TO BOX + (1) EDGE ROW EACH PLATE STAGGERED. REAR TOP BLOCK TOP SEAM 0 ANDERSEN TW26410 OR = 2'-6"x5'-1" R.O. O ANDERSEN TW30410 OR = 3'-2"x5'-1" R.O. ® ABOVE MAX FIRE PLACE UNIT 49" V.I.F. +1 SIDE CLEAR = 58" FRAME DESIGN BASED ON ANDERSEN FOR REFERENCE ONLY G.C. TO PROVIDE SIMILAR HARVEY TRIBUTE WINDOW DOUBLE GLAZED, 2xARGON GAS, U 0.30 OR LOWER DOOR: ® ANDERSEN FRENCHWOOD OR = FWH5068 XX VERIFY A -" ASPHALT ROOF SHINGLE MATCH HOUSE. OVER ROOF ING FELT P MANUFACTURE PVC TRIM TO MATCH HOUSE 1x4,1x5 PVC CORNER BOARDS I I I I I I I I LEFT ELEVATION C1-AI C 1 IA" — 1' n" RIGHT ELEVATION SCALE 1 /4" = 1'-0" EXISTING HOUSE co O N RIGHT f10'-9" NEW OPENING REMOVE SLIDER 2'- 4" ®MiF1--- ;--- ji - IV II HEA HEA 14'-0" ADDITION ICm (2) 1 3/4x9 J" LVL HEADER 7'-2" AFF. NEW 2x4®16" O.C. GABLE. FOAM INSULATE TO R21 0o t8'-8" EXISTING EXISTING FLOOR DROPPED 6" FURR W/ NEW 2x6®24"O.C. + J" PLYWOOD. FILL VOID W/ `n FOAM INULSULATION 6.5/IN =Rt36 SEE FRAMING PLAN FO FIREPLACE CANTILEVER LEFT BLOC Lo EXIS SLAE 0 BELC I © 2'-4" 1 SIDE W TO EXI! DECK, HOUSE PLAN Wf ADDITION & NEW DECK SCALE 1 /4" = 1'-0" I I I I I I L-----------t FOUNDATION PLAN SCALE 1 /4" = 1'-0" 1 '-14 1 /2" 1 1 1 1 I I 14'-0" 1 1 i li I I I I i I I I I I I I I I I i I I I I I I I I L—J L—J L—J REAR ELEVATION SCALE 1 /4" = 1'-0" EXISTING ROOF/GIR J" STRAPPING + J" EXISTING 4x4 GIRT 2x3 CUT FOR HANC UNVENTED SOFFIT CLR VENT >=12" 24" CANTILEVER FOR 49" GAS FIREPLACE P'VC BELT TO ALIGN SHINGLE COURSES EXISTING 12" PIERS NOTE: ALL FRAMING P.T. SYP f10'-9" NEW OPENING SUN ROOM FRAME I7OR EMPIRE GAS UNIT DVP48 UNIT 48 + I" CLEAR + 7" FRM OUT TO OUT FRAME 55 i" VERIFY UNIT USED & CONSULT MANUFACTURES SPECIFICATIONS VENT OPENING FRAME HEADER (2) 2x4 W/JACK+STUD @ SIDES POST ABOVE HEADER TO RIDGE 6'-0" SHORT 2x6 2'-0" R49 ® O.H. 2X6 JOIST O.H. 22 1/2" ® 2X8 P.T. FOAM R6.5 IN=R=36 2X1.75 NET P.T. EXISTING FLOOR SHIM VERIFY - MIN J" P.T. PLY CONT P.T. NAILER JO1 ST B i I 14"-0" I I I I I I I I 1 I I I I I I I I I I I I I I I t I SECTION #1 SCALE 1 /4" = 1'-0" RECEIVED SEA' 15 ?R? HEALTH DEPT. 2x4 FOR 2x3 CROWS MOUTH 20 ADD 1 3/4x 11 J" LVL BELOW EXISTING 2x4 COLLAR TIES 20 SHIM EXISTING 2x6 EXISTING EVE AND BEAM (W/GYPSUM) REMOVED. STRIP WALL TO PLAYWOOD. INSTALL NEW LVL HEADER & GABLE FRAMING MAKING WALL FLUSH MATCH EXISTING O.H.W/PVC TRIM + MOUNDING DOOR OPENING VERIFY R.O. 95"-6 1/2-7 J" = 6'-8 J" OK EXISTING GIRT TRIM MAX 2". (2) J EACH SIDE SEE JJ+2 1 /2+J ON PLAN PROPOSED STEP & PLANTER SHOWN TO ACCENT NEED TO CLEAR OPERABLE WINDOWS. VERIFY LAYOUT BEFORE ORDERING WINDOWS ' o= PATH OF MASS9cyG THOMAS M. cn CALLERY CIVIL No. 33440 9 0 2 A90� F�/STEPS SS�ONAL ENS 09-06-22 WIND DESIGN: L = 14'; W= 12.5'; L/W = 1.12 REAR W 4/14 = 0.29% NAIL SHEAR NAIL 4" O.C. EDGE RIGHT & LEFT CONT GIRT HRADER FOR WIND. (4) 8" TIMBER LOCK FRT TO SIDE HEADER. BEND (1) MSTA14 AROUND CORNER USE 10' SHEETS VERTICAL (3) EDGE ROW STAGGERED TO BOX + (1) EDGE ROW EACH PLATE STAGGERED. REAR TOP BLOCK TOP SEAM 10 ANDERSEN TW26410 OR = 2'-6"x5'-1" R.O. O ANDERSEN TW30410 OR = 3'-2"x5'-1" R.O. ® ABOVE MAX FIRE PLACE UNIT 49" V.I.F. +1 SIDE CLEAR = 58" FRAME DESIGN BASED ON ANDERSEN FOR REFERENCE ONLY G.C. TO PROVIDE SIMILAR HARVEY TRIBUTE WINDOW DOUBLE GLAZED, 2xARGON GAS, U 0.30 OR LOWER DOOR: ® ANDERSEN FRENCHWOOD OR = FWH5068 XX VERIFY P --" "- ASPHALT ROOF SHINGLE MATCH HOUSE. OVER ROOF ING FELT P MANUFACTURE PVC TRIM TO MATCH HOUSE 1 x4,1 x5 PVC CORNER BOARDS LEFT ELEVATION RIGHT ELEVATION SCALE 1 /4" = 1'-O" EXISTING HOU RIGHT t10'-9" NEW OPENING REMOVE SLIDER 0 I SUN ! ROOM li '� il it HEA HEA 14'-0" ADDITION 1000101 (2) 1 3/4x9 J" LVL HEADER 0 7'-2" AFF. NEW 2x4016" O.C. GABLE. FOAM INSULATE TO R21 ao f8'-8" EXISTING EXISTING FLOOR DROPPED 6" FURR W/ NEW 2x6024"O.C. + " PLYWOOD. FILL VOID W/ `-) FOAM INULSULATION 6.5/IN =Rt36 SEE FRAMING PLAN FO FIREPLACE CANTILEVER LEFT BLOC EXIS SLAE 10 BELC i © 1 2'-4" SIDE W TO EXI' DECK, HOUSE PLAN Wf ADDITION & NEW DECK SCALE 1 /4" = 1'-O" I I I I I I L---------J FOUNDATION PLAN SCALE 1/4" = 1'-C" 4 1 /2" 1 1 1 1 14'-0' I I f i I i i I I i I I I I I I I I I i I L-J L-J-J REAR ELEVATION` SCALE 1 /4" = 1'-0" EXISTING ROOF/GIR J" STRAPPING + }" EXISTING 4x4 GIRT 2x3 CUT FOR HANC JNVENTED SOFFIT CLR JEN T >=12- W CANTILEVER FOR 0" GAS FIREPLACE 'VC BELT TO ALIGN SHINGLE COURSES EXISTING 12- PIERS NOTE: ALL FRAMING P.T. SYP f 10'-9" NEW OPENING SUN ROOM FRAME FOR EMPIRE GAS UNIT DVP48 UN T 48 + J" CLEAR + 7" FRM OUT TO OUT FRAME 55 J" VERIFY UNIT USED & CONSULT MANUFACTURES SPECIFICATIONS VENT OPENING FRAME HEADER (2) 2x4 W/JACK+STUD 0 SIDES POST ABOVE HEADER TO RIDGE 6'-0" SHORT 2x6 2'- 0" R49 0 O.H. 2X6 JOIST O.H. 22 1 /2" (A)2X8 P.T. ----- _ FOAM R6.5 IN=R=36 2X1.75 NET P.T. EXISTING FLOOR SHIM VERIFY - MIN J" P.T. PLY CONT P.T. NAILER JOIST B I I I I I I I I I I I I I I I I I I I 1 I I I L-J L-J R 1— y u 2x4 FOR 2x3 CROWS MOUTH 20 ADD 1 3/4x 11 J" LVL BELOW EXISTING 2x4 COLLAR TIES 20 SHIM EXISTING 2x6 EXISTING EVE AND BEAM (W/GYPSUM) REMOVED. STRIP WALL TO PLAYWOOD. INSTALL NEW LVL HEADER & GABLE FRAMING MAKING WALL FLUSH MATCH EXISTING O.H.W/PVC TRIM + MOUNDING DOOR OPENING VERIFY R.O. 95"-6 1/2-7 J" = 6'-8 J" OK EXISTING GIRT TRIM MAX 2". (2) J EACH SIDE SEE JJ+2 1 /2+J ON PLAN PROPOSED STEP & PLANTER SHOWN TO ACCENT NEED TO CLEAR OPERABLE WINDOWS. VERIFY LAYOUT BEFORE ORDERING WINDOWS HL �. SECTION #1 SCALE 1 /4" = 1'-0" R �t P�jN OF 1�qSS REVIEWED FOR BUILDING ZONINGAND CODE COi „ o� tiG ANCE. ERRORS OR OMMISSIONS DO NOT RELIEVE THGALLE i: TM. N GALLERY APPLICANT FROM THE RESPONSIBILITY OF "AS BUILT" o CIVIL COMPLIANCE. No. 33440 DATE: _ Ago 9�(3/STEP�����Q FSS/ONAL ENG BUILDING FFICIAL 09-06-22 n E cr- z�Q� fi� ryLL-� O QJ=N Q C) U) LLI O 00 f— F-3: :�iO z o' }- Lo U LLJ d- _J U M Ln O_ � —0 ~- Q � W � z � f— Q U � W W Q � W o � IH: 2022\KEVIN \GASLIGHT 31 %J- Z--3- a(oi�f-'` ) LOCATION MAP MAP 22 PCL. 189 f r� i i 2 /21 /ZZ DATE I FILE=23515.CtVGj MAP 22 PCL. 184 0 PROPOSED ,. ADDITION �fl PROPOSED ADDITION SEPTIC TANK < -N `N MAP 22 moo' PCL. 190 oIIN Is, �Q 5r0 �r. lb so r � 'Aa � o � -9 �+ . O LOT 7 8,800t S.F. (0.20f AC.) ZONING DISTRICT: R-25 REQUIRED 25,000 S.F. EXISTING PROPOSED MIN. LOT AREA 8,800f S.F. j 8,800t S.F. MIN. LOT FRONTAGE 150' 88.00' 88.00' FRONT SETBACK 30' 39.6't 1 39.6'f SIDE SETBACK 15, 6.6'f 6.6'f REAR SETBACK 20' 11.9'f 11.9't BUILDING COVERAGE 19.4t% 20.8±7 OWNER OF RECORD: JOANNA C. MURRAY 595 E BROADWAY UNIT #3 BOSTON, MA 02127 REFERENCES: CERTIFICATE #221090 LAND COURT PLAN # 1 1435--A ASSESSORS MAP 22 PARCEL 183 FLOOD HAZARD ZONE. X THE SEPTIC SYSTEM SHOWN IS AN APPROXIMATE LOCATION BASED ON BOARD OF HEALTH RECORDS. � 1 ; ��° SITE P LA N 1 , I� 45 RAINBOW ROAD 1 MAP 22 PCL. 192 WEST YAR M O UTH , MA MAP 22 PCL. 191 \ PREPARED FOR: J OAN NA M U R RAY SCALE: 1 " = 20' FEBRUARY 21, 2023 GRAPHIC SCALE IN FEET 20' 10' 0' 20' 40' DEMAREST LAND SURVEYING 338 MAYFAI R ROAD SOUTH DENNIS, MA 02660 508--364-9049 /3tD°4-23-/2fOS