Loading...
HomeMy WebLinkAbout31 Grist Mill Ln plan008FRAMING REQUIREMENTS ` STRUCTURAL: • - LALLY COLUMNS INSTALLED TIGHT TO BEAMS & PLATES CONNECTED • POINT LOAD BEARING - SOLID. BLOCKED AND CONTINUOUS • BASEMENT BEAM HAS SOLID BEARING AT POCKETS, NO WOOD SHIMS • ALL HURRICANE CLIPS; TIE DOWNS HANGERS ETC. INSTALLED & NAILED OFF COMPLETELY • ALL JACKS SHALL BE TIGHT TO STRUCTURAL HEADERS, ANY FURRING DOWN OF OPENING SHALL BE BETWEEN JACKS. • JACKS SHALL NOT BEAR ON SILL COMPONENTS, THEY ARE TO RUN CONTINUOUS FROM HEADER TO BOTTOM PLATE CRACKED OR SPLIT STRUCTURAL MEMBERS SHOULD NOT BE USED • LVLS & PSLS IN PLACE PER STRUCTURAL PLANS, TIMBERLOCKED TOGETHER + COLLAR TIES WHERE REQUIRED •. CONNECTIONS IN GENERAL ARE TIGHT & SECURE I • JOIST SPACED PER PLAN, BEARING AT ENDS • ROOF SHEATHING BROKEN BACK FROM ROOF RIDGE VENT CLEARANCE - SHEATHING TO MEET OVER RIDGE I FOOT FROM GABLE ENDS AND 1 FOOT BACK FROM INTERSECTION OF RIDGE AT CHECK WALLS/OTHER ROOFS. SHEATHING SHOULD MEET IF NO VENT. GENERAL: • BLOCKING FIRE - AS REQUIRED BY CODE - MID SPAN, ALL WALLS OVER 8 FT. - SHOWERS - 2X10 AROUND PERIMETER OF BASE • ROUGH OPENINGS - CHECK FOR CORRECT SIZE, PLUMB AND WIND • MEDICINE CABINETS - IF RECESSED ARE THEY FRAMED? • PLYWOOD BREAKS ON JOIST, STUD, OR RAFTERS (NO BLOCKING) • ' FLOOR PLYWOOD GLUED AND NAILED & CHECKED FOR SOFT SPOTS & SQUEAKS • ALL WALLS - PLUMB, SQUARE, STRAIGHT AND DIMENSIONALLY CORRECT • CABINET AND VANITY WALLS DOUBLE CHECKED FOR STRAIGHTNESS • .STRAPPING - NAILED OFF AND STRAIGHT • NAILERS - ALL MISCELLANEOUS NAILERS FOR SHEET ROCK ARE IN PLACE + PLATFORM TUB DIMENSIONS ARE VERIFIED CORRECT IF APPLICABLE • STAIRS - FINISH TREAD THICKNESS/RISE / RUN / WIDTH / HEADROOM / SPECIAL DETAILS VERIFIED • CONFIRM'/2 WALL STABILITY • PROVIDE 2X WIND BLOCKING IN RAFTER BAYS; TYPICAL • SKY LIGHTS PADDED FOR SHEET ROCK IF APPLICABLE • STUDS - TWISTED OR LOOSR(TOE NAILED) REPLACE AS NEEDED • BOTH TOP AND BOTTOM WALL PLATES TO BREAK ON STUD • DUCT CHASES HEADED OFF • JOISTS SPACED FOR PLUMBING - TOILET WASTE NEEDS 3" CLEAR • BATH VALVE WALLS HAVE 16" CLEAR BAY CENTERED FOR VALVE • SCUTTLES IN PROPER PLACE • HEADER HEIGHTS AND DROPPED CEILING HEIGHTS ARE VERIFIED CORRECT • INTERIOR PARTITIONS TIGHT TO STRAPPING INTERIOR BEARING PARTITIONS - TOP PLATE TIGHT TO JOISTS • ALL HEADERS, JACK / STUD COMBOS &CORNERS SHALL BE NAILED THROUGH BOTH SIDES • ALL HEADERS TO BE NAILED THROUGH KING STUDS • SILLS TO BE TOE NAILED TO JACKS AS WELL AS NAILED TO CRIPPLES • ALL WALL PLATES SHALLBREAKON STUD LAYOUT • EXTERIOR WALL BOTTOM PLATES TO BE SEALED TO DECK WITH CONSTRUCTION ADHESIVE •' RIGID INSULATION TO BE INSTALLED IN EXTERIOR WALL PARTITION BACKERS & IN HEADERS (2X6 WALL) IN LIEU OF PLYWOOD • FRAME IN VESTIBULE AT BULKHEAD AND INSTALL PLYWOOD ON BULKHEAD SIDE • FRAME IN TILED SHOWER HEADERS WHERE APPLICABLE • INSTALL VERTICAL lx5 KOMA ON EITHER SIDE OF OVERHEAD GARAGE DOORS AS WELL AS ABOVE TO RECEIVE TRACKS AND OPENER SPRINGS. INCLUDE ALL RELATED BLOCKING EXTERIOR TRIM & MILLWORK: • PAINTED TRIM (IF APPLICABLE) IS BACK PRIMED INCLUDING ALL FRESH CUT EDGES • PVC TRIM JOINTS TO BE GLUED WITH BOND N FILL OR EQUAL + PVC TRIM TO BE FASTENED W/SCREWS OR HEADED NAILS, NO FINISH NAILS OR BRADS •' NAILS ARE SET FOR PAINT, FLUSH FOR NATURAL TRIM; NAILS_ SHALL NOT STAND PROUD OF TRIM • TRIM IS STRAIGHT AND TRUE, JOINTS ARE FLUSH, TRIM IS DAMAGE FREE • SOFFIT VENT NEAT AND CONTINUOUS • HOLD TRIM '/a 1NCH AWAY FROM ROOF SHINGLES 1 INCH BELOW THE DROP OF FOUNDATION • TOE KICKS AT DOORS ARE SUPPORTING SILLS • FRIEZE BOARDS, BOTTOM OF WINDOW CASINGS AND WINDOW APRONS ARE RABBETEDA" DEEP X I" HIGH FOR SIDEWALL SHINGLES, 2ND TO LAST COURSE TO GO UNDER, LAST COURSE TO BUTT TRIM + FABRICATE RABBETED LIGHT & VENT BLOCKS & TACK IN PLACE FOR FINAL INSTALL BY OTHERS • DOOR LEAD TO HAVE FOLDED - NOT CUT - CORNERS, FOLD LEAD UP, INSTALL TEMPORARY -% (STRAPPING) BOARD & TRIM LEAD ALONG TOP OF STRAPPING • INSTALL WINDOWS WITH FLEX WRAP PANS TO BE FOLDED UP AND STAPLED TO INSIDE WINDOW SILL, UNLESS OTHERWISE NOTED • INSTALL WINDOWS AND DOORS PLUMB, LEVEL. & SHIMMED TO MANUFACTURER'S SPECS PRIOR TO INSTALLATION OF EXTERIOR TRIM. • CHECK THAT ALL WINDOWS & DOORS OPERATE SMOOTHLY • CONFIRM ALL TEMPERED UNITS ARE IN CORRECT LOCATION • ENTRY DOORS OTHER THAN SLIDERSIPATIO, ARE SHIMMED UP W' FROM SUB FLOOR • BUILDING PAPER - ALL EXTERIOR TRIM SHALL HAVE TARPAPER BENEATH IT AT ALL SEAMS WHERE IT MEETS SIDING. ALL ICE & WATER, VYCOF, ETC. SHALL BE INSTALLED SO THAT BUILDING PAPER CAN BE SLIPPED UNDER IT SO OVERLAP IS CONTINUOUS FROM THE TOP DOWN. DO NOT LEAVE I&W OR VYCOR STUCK TO THE SHEATHING. • RETURN AFTER SIDING TO CUT DOWN CORNER BOARDS SITE CONDITIONS: • REMOVE ALL STAGING, TEMPORARY BRACING, CLEATS ETC. • ALL LOW SILL HEIGHT SECOND FLOOR WINDOW OPENINGS SHALL HAVE A 2X4 SAFETY RAIL NAILED OVER THE OPENING UNTIL WINDOW IS SET. • ALL HOLES IN 1 ST AND 2ND FLOORS SHALL BE COVERED OVER FOR SAFETY; BALCONIES AND STAIRWELLS SHALL HAVE TEMPORARY RAILS. + ALL MATERIAL SHALL BE KEPT IN NEAT PILES AND JOB SITE SHALL BE CLEANED EACH DAY. • ALL LUMBER PILES TO BE COVERED FOR PROTECTION • IF PROJECT IS A RENOVATION, EXISTING STRUCTURE TO BE WEATHER TIGH NIGHTLY • ALL TRASH TO BE PUT IN DUMPSTER OR ON -SITE BARRELS. MCPHEE LABOR IS PROVIDED TO EMPTY BARRELS AS NEEDED NOT TO CLEAN UP SITE BEHIND SUBCONTRACTOF..S. v N z U U uw v a Q U ¢ Nz O ,-s O n .O z KN_ � v 6� x O 0 � C `1 N � coco W X Cn (� V1 O co O Ms N O i bA 2022-07-26