HomeMy WebLinkAbout31 Grist Mill Ln plan008FRAMING REQUIREMENTS `
STRUCTURAL:
• - LALLY COLUMNS INSTALLED TIGHT TO BEAMS & PLATES CONNECTED
• POINT LOAD BEARING - SOLID. BLOCKED AND CONTINUOUS
• BASEMENT BEAM HAS SOLID BEARING AT POCKETS, NO WOOD SHIMS
• ALL HURRICANE CLIPS; TIE DOWNS HANGERS ETC. INSTALLED & NAILED
OFF COMPLETELY
• ALL JACKS SHALL BE TIGHT TO STRUCTURAL HEADERS, ANY FURRING
DOWN OF OPENING SHALL BE BETWEEN JACKS.
• JACKS SHALL NOT BEAR ON SILL COMPONENTS, THEY ARE TO RUN
CONTINUOUS FROM HEADER TO BOTTOM PLATE
CRACKED OR SPLIT STRUCTURAL MEMBERS SHOULD NOT BE USED
• LVLS & PSLS IN PLACE PER STRUCTURAL PLANS, TIMBERLOCKED TOGETHER
+ COLLAR TIES WHERE REQUIRED
•. CONNECTIONS IN GENERAL ARE TIGHT & SECURE I
• JOIST SPACED PER PLAN, BEARING AT ENDS
• ROOF SHEATHING BROKEN BACK FROM ROOF RIDGE VENT CLEARANCE -
SHEATHING TO MEET OVER RIDGE I FOOT FROM GABLE ENDS AND 1 FOOT
BACK FROM INTERSECTION OF RIDGE AT CHECK WALLS/OTHER ROOFS.
SHEATHING SHOULD MEET IF NO VENT.
GENERAL:
• BLOCKING
FIRE - AS REQUIRED BY CODE
- MID SPAN, ALL WALLS OVER 8 FT.
- SHOWERS - 2X10 AROUND PERIMETER OF BASE
• ROUGH OPENINGS - CHECK FOR CORRECT SIZE, PLUMB AND WIND
• MEDICINE CABINETS - IF RECESSED ARE THEY FRAMED?
• PLYWOOD BREAKS ON JOIST, STUD, OR RAFTERS (NO BLOCKING)
• ' FLOOR PLYWOOD GLUED AND NAILED & CHECKED FOR SOFT SPOTS &
SQUEAKS
• ALL WALLS - PLUMB, SQUARE, STRAIGHT AND DIMENSIONALLY CORRECT
• CABINET AND VANITY WALLS DOUBLE CHECKED FOR STRAIGHTNESS
• .STRAPPING - NAILED OFF AND STRAIGHT
• NAILERS - ALL MISCELLANEOUS NAILERS FOR SHEET ROCK ARE IN PLACE
+ PLATFORM TUB DIMENSIONS ARE VERIFIED CORRECT IF APPLICABLE
• STAIRS - FINISH TREAD THICKNESS/RISE / RUN / WIDTH / HEADROOM /
SPECIAL DETAILS VERIFIED
• CONFIRM'/2 WALL STABILITY
• PROVIDE 2X WIND BLOCKING IN RAFTER BAYS; TYPICAL
• SKY LIGHTS PADDED FOR SHEET ROCK IF APPLICABLE
• STUDS - TWISTED OR LOOSR(TOE NAILED) REPLACE AS NEEDED
• BOTH TOP AND BOTTOM WALL PLATES TO BREAK ON STUD
• DUCT CHASES HEADED OFF
• JOISTS SPACED FOR PLUMBING - TOILET WASTE NEEDS 3" CLEAR
• BATH VALVE WALLS HAVE 16" CLEAR BAY CENTERED FOR VALVE
• SCUTTLES IN PROPER PLACE
• HEADER HEIGHTS AND DROPPED CEILING HEIGHTS ARE VERIFIED CORRECT
• INTERIOR PARTITIONS TIGHT TO STRAPPING
INTERIOR BEARING PARTITIONS - TOP PLATE TIGHT TO JOISTS
• ALL HEADERS, JACK / STUD COMBOS &CORNERS SHALL BE NAILED
THROUGH BOTH SIDES
• ALL HEADERS TO BE NAILED THROUGH KING STUDS
• SILLS TO BE TOE NAILED TO JACKS AS WELL AS NAILED TO CRIPPLES
• ALL WALL PLATES SHALLBREAKON STUD LAYOUT
• EXTERIOR WALL BOTTOM PLATES TO BE SEALED TO DECK WITH
CONSTRUCTION ADHESIVE
•' RIGID INSULATION TO BE INSTALLED IN EXTERIOR WALL PARTITION
BACKERS & IN HEADERS (2X6 WALL) IN LIEU OF PLYWOOD
• FRAME IN VESTIBULE AT BULKHEAD AND INSTALL PLYWOOD ON BULKHEAD
SIDE
• FRAME IN TILED SHOWER HEADERS WHERE APPLICABLE
• INSTALL VERTICAL lx5 KOMA ON EITHER SIDE OF OVERHEAD GARAGE
DOORS AS WELL AS ABOVE TO RECEIVE TRACKS AND OPENER SPRINGS.
INCLUDE ALL RELATED BLOCKING
EXTERIOR TRIM & MILLWORK:
• PAINTED TRIM (IF APPLICABLE) IS BACK PRIMED INCLUDING ALL FRESH CUT
EDGES
• PVC TRIM JOINTS TO BE GLUED WITH BOND N FILL OR EQUAL
+ PVC TRIM TO BE FASTENED W/SCREWS OR HEADED NAILS, NO FINISH NAILS
OR BRADS
•' NAILS ARE SET FOR PAINT, FLUSH FOR NATURAL TRIM; NAILS_ SHALL NOT
STAND PROUD OF TRIM
• TRIM IS STRAIGHT AND TRUE, JOINTS ARE FLUSH, TRIM IS DAMAGE FREE
• SOFFIT VENT NEAT AND CONTINUOUS
• HOLD TRIM '/a 1NCH AWAY FROM ROOF SHINGLES 1 INCH BELOW THE DROP
OF FOUNDATION
• TOE KICKS AT DOORS ARE SUPPORTING SILLS
• FRIEZE BOARDS, BOTTOM OF WINDOW CASINGS AND WINDOW APRONS ARE
RABBETEDA" DEEP X I" HIGH FOR SIDEWALL SHINGLES, 2ND TO LAST
COURSE TO GO UNDER, LAST COURSE TO BUTT TRIM
+ FABRICATE RABBETED LIGHT & VENT BLOCKS & TACK IN PLACE FOR FINAL
INSTALL BY OTHERS
• DOOR LEAD TO HAVE FOLDED - NOT CUT - CORNERS, FOLD LEAD UP, INSTALL
TEMPORARY -% (STRAPPING) BOARD & TRIM LEAD ALONG TOP OF STRAPPING
• INSTALL WINDOWS WITH FLEX WRAP PANS TO BE FOLDED UP AND STAPLED
TO INSIDE WINDOW SILL, UNLESS OTHERWISE NOTED
• INSTALL WINDOWS AND DOORS PLUMB, LEVEL. & SHIMMED TO
MANUFACTURER'S SPECS PRIOR TO INSTALLATION OF EXTERIOR TRIM.
• CHECK THAT ALL WINDOWS & DOORS OPERATE SMOOTHLY
• CONFIRM ALL TEMPERED UNITS ARE IN CORRECT LOCATION
• ENTRY DOORS OTHER THAN SLIDERSIPATIO, ARE SHIMMED UP W' FROM SUB
FLOOR
• BUILDING PAPER - ALL EXTERIOR TRIM SHALL HAVE TARPAPER BENEATH IT
AT ALL SEAMS WHERE IT MEETS SIDING. ALL ICE & WATER, VYCOF, ETC.
SHALL BE INSTALLED SO THAT BUILDING PAPER CAN BE SLIPPED UNDER IT
SO OVERLAP IS CONTINUOUS FROM THE TOP DOWN. DO NOT LEAVE I&W OR
VYCOR STUCK TO THE SHEATHING.
• RETURN AFTER SIDING TO CUT DOWN CORNER BOARDS
SITE CONDITIONS:
• REMOVE ALL STAGING, TEMPORARY BRACING, CLEATS ETC.
• ALL LOW SILL HEIGHT SECOND FLOOR WINDOW OPENINGS SHALL HAVE A
2X4 SAFETY RAIL NAILED OVER THE OPENING UNTIL WINDOW IS SET.
• ALL HOLES IN 1 ST AND 2ND FLOORS SHALL BE COVERED OVER FOR SAFETY;
BALCONIES AND STAIRWELLS SHALL HAVE TEMPORARY RAILS.
+ ALL MATERIAL SHALL BE KEPT IN NEAT PILES AND JOB SITE SHALL BE
CLEANED EACH DAY.
• ALL LUMBER PILES TO BE COVERED FOR PROTECTION
• IF PROJECT IS A RENOVATION, EXISTING STRUCTURE TO BE WEATHER TIGH
NIGHTLY
• ALL TRASH TO BE PUT IN DUMPSTER OR ON -SITE BARRELS. MCPHEE LABOR
IS PROVIDED TO EMPTY BARRELS AS NEEDED NOT TO CLEAN UP SITE BEHIND
SUBCONTRACTOF..S.
v
N
z
U
U
uw v
a Q
U ¢
Nz
O
,-s
O
n
.O
z KN_
� v
6�
x
O
0 �
C `1
N �
coco
W X
Cn
(�
V1
O
co
O
Ms
N
O
i
bA 2022-07-26