Loading...
HomeMy WebLinkAboutsite planFGFND ii SYSTEM PROFILE PROVIDE MIN. 20" DIAM. WATERTIGHT (NOT TO SCALE) ACCESS COVERS TO WITHIN 6" OF FIN. GRADE \ TOP FOUND. EL 12.1 10.5'J MINIMUM J5' OF COVER OVER PRECAST 2% SLOPE REQUIRE NOTE: 2" MIN. WALL PRECAST H-to THICKNESS REQUIRED RISERS (TYP.) 2'0 4"OSCH40 PVC PIPES LEVEL 1 ST 2' *9.0' a 8.45' TEE 1500 GAL H-10 0. T E y: 8.20 ' SEPTIC TANK WATERTEST D'BOX 4' LIQ. LEVEL *8.O ',-° oO°0-e'-0 SLAB EL 7.1 ACME OR EQUAL GAS BAFFLE :.: �?0000000' ?, FOR LEVELNESS V.I.F. REPLACE EXISTING D BOX IF ,.. - ':, .......:•.:...:.,.... ;: ..<•. REQUIRED MATCH J°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°°° EXISTING GRADES 0°0°°°°°°°°°°°°°0°O°°°0°°°O°O°O°O°O°O°O°O°O°O 6" CRUSHED STONE OR MECHANICAL COMPACTION. (15.221 [21) SYSTEM DESIGN: (5 % SLOPE) (1 % SLOPE) GARBAGE DISPOSER IS NOT ALLOWED EXISTING FOUNDATION 11 SEPTIC TANK 17' D' BOX EXISTING EXISTING 4 BEDROOM DWELLING PROPOSED 4 BEDROOM DWELLING *THE INSTALLER SHALL VERIFY THE LOCATIONS OF ALL UTILITIES AND ALL BUILDING SEWER OUTLETS AND ELEVATIONS DESIGN FLOW: 4 BEDROOMS 0 110 GPD = 440 GPD PRIOR TO INSTALLING ANY PORTION OF SEPTIC SYSTEM USE A 440 GPD DESIGN FLOW SEPTIC TANK: 440 GPD (2) = 880 USE A 1500 GAL. SEPTIC TANK USE EXISTING 4 BEDROOM LEACHING FIELD INSTALLED 4-16-2013 S TREE IVER R APPROVED DATE BOARD OF HEALTH MA ,�• x ox 3.60 �� w °$ 0 O� ROOF LOT AR DRYWELL 26,384 S. (TYP.) PROP. RETAINING WALL 10- (DESIGN BY OTHERS) [9] N AP ROX HSE 00 PORCH 0 L C. PE GIS , MA G a PROPOSED DWELLING 0 1 1 R ER ST S O AP 34 PARCEL 293 vr,� ECG OTTMAR DANNER CM DB 7583 PG 27 � 1' 19" � m i •� pro /�j/� N83, 3 I y r�( PROPOED SLAB 1 Q.1 x 3 d,. O 3 PROPOS 3 o RAVEL DRIV Lo d M '� 61 en o V Z o � 00 PPROX. SE LO . RAID ER GIS APPIN GARDE a a M P 34 P RCEL 294 N ti85 $2 USTIN I UIER TRS MAP 34 PARCEL 29 B 31 PG 136 JOSEPH GILMORE CERT 225924 #150 SOU T STRE S.F JDCE #23-22 D OVER SYSTEM 9.O' USE EXISTING SAS SEE 2013 PLANS 00000000000°0°0°o°o°c o°o°o°o°o°o°o°o°o°o°< o°0°0°0°0°0°0°0°0°0°< o000000°0°0°0°0000 01, 00000000000Mo0o0o0c EXISTING LEACHING FACILITY �0 (0' 7 EA / 8 / 0 RIVER S PARCEL 291 / CULLOUGH 22475 � C NOTES 1. DATUM IS NAVD88 2. MUNICIPAL WATER IS EXISTING 3. MINIMUM PIPE PITCH TO BE 1/8" PER FOOT. 4. DESIGN LOADING FOR ALL PROPOSED PRECAST UNITS TO BE AASHO H-10 5. PIPE JOINTS TO BE MADE WATERTIGHT. 6. CONSTRUCTION DETAILS TO BE IN ACCORDANCE WITH 10 CMR 15.000 (TITLE 5.) 7. THIS PLAN IS FOR PROPOSED WORK ONLY AND NOT TO BE USED FOR LOT LINE STAKING OR ANY OTHER PURPOSE. 8. PIPE FOR SEPTIC SYSTEM TO SCH. 40-4" PVC. 9. COMPONENTS NOT TO BE BACKFILLED OR CONCEALED WITHOUT INSPECTION BY BOARD OF HEALTH AND PERMISSION OBTAINED FROM BOARD OF HEALTH. 10. CONTRACTOR SHALL BE RESPONSIBLE FOR CALLING DIGSAFE (1-888-344-7233) AND VERIFYING THE LOCUS MAP LOCATION OF ALL UNDERGROUND & OVERHEAD U11LIlIES PRIOR TO COMMENCEMENT OF WORK. SCALE 1 "=2000'f 11. FLOOD RESISTANT FOUNDATION DESIGN BY OTHERS. ASSESSORS MAP 34 PARCEL 292.1 12. GUTTERS AND DOWNSPOUTS TO BE DIRECTED TO DRYWELLS OR ROOF DRIP LINES TO STONE TRENCHES. LOCUS IS WITHIN FEMA FLOOD ZONE AE (EL 11) AS SHOWN ON COMMUNITY PANEL #25001CO589J 13. EXISTING SEPTIC LOCATION PER TIE -CARD ON FILE DATED 7 16 2014 WITH TOWN. PROPOSED DWELLING IS WITHIN AE (EL 11) DESIGN FLOOD ELEVATION 12.0 ZONING SUMMARY ZONING DISTRICT: RS-40 RESIDENTIAL DISTRICT REQUIRED: EXISTING: PROPOSED: MIN. LOT SIZE 40,000 S.F. 26,384 S.F. 26,384 S.F. MIN. LOT FRONTAGE 150' 123.6' 123.6' MIN. FRONT SETBACK 30' 91.6' 51.5' MIN. SIDE SETBACK 20' 48.6' 31.0' MIN. REAR SETBACK 20' 39.4' 42.5' MAX. BUILDING COVERAGE 25% 6.4% 10.8% MAX. BUILDING HEIGHT 35' %0E, ' 7"1 T E rr �71 L A- N OF #179 RIVER STREET SOUTH YARMOUTH, MA_ PREPED FOR JOSEPH DATE: OCTOBER 3, 2023 Scale: 1 "= 20' o Fs0 10 20 30 40 50 FEET off 508-362-4541 D fl n <� '; r:, �` fax 508-362-9880 , t t c e e i e �i i �A`� NO �.>�� f down ap ng n e a #7 Fs�='T /�' �slka .� Civil engineers ,,.., land surveyors z,7 y 939 Main Street ( Rte 6A) YARMOUTHPORT MA 02675 DATE DANIEL A. OJALA, P.E., L.S. DRAFTED BY: CJF CHECKED BY: