Loading...
HomeMy WebLinkAboutPlan_rev 10.05.23790 SFEXISTINGBUILDING19 191919540 SFPROPOSEDMITIGATIONPLANTING1920 18215 SF EXISTINGFIELD STONE WALLTO REMAINEXISTING VEG.TO REMAIN EXISTING VEG.TO REMAIN2020 2119454 SFPROPOSEDLAWNEXISTING VEG.TO REMAIN123 SFPROPOSEDBUILDING211919 19212119 20 202050' FROM TOP OFCOASTAL BANK100' FROM TOP OFCOASTAL BANKPROPERTYLINE50' FROM TOP OFCOASTAL DUNE100' FROM TOP OFCOASTAL DUNETOP OFCOASTALBANKTOP OFCOASTALDUNE1,430 SFPROPOSEDHARDSCAPEEXISTING VEG.TO REMAINEXISTING VEG.TO REMAINEXISTING VEG.TO REMAIN 2,132 SFPROPOSEDMITIGATIONPLANTING6,596 SFPROPOSEDLAWN130 SFPROPOSEDHARDSCAPE50' FROM TOP OFCOASTAL DUNE100' FROM TOP OFCOASTAL DUNE20 192120 21 201918171650'-0"BUILDING SETBACK EXISTING TREETO BE REMOVED202020202020VOID514 SFPROPOSEDBUILDING790 SFEXISTINGBUILDING1,871 SF EXISTINGBUILDINGPROPOSED FIRSTFLOOR BUILDINGFOOTPRINTSHOWN FORREFERENCEEXISTINGTREEEXISTING WOODPLANK BOARDWALKEXISTINGLAWNEXISTINGRESIDENCEEXISTINGLAWNEXISTINGLAWNEXISTINGLAWNEXISTINGLAWNEXISTINGLAWNEXISTINGGRAVEL DRIVEEXISTINGGRAVEL DRIVEEXISTINGGRAVEL DRIVEEXISTINGGRAVEL DRIVEEXISTINGLAWNEXISTINGLAWNEXISTINGVEG.EXISTINGVEG.EXISTINGVEG.EXISTINGVEG.EXISTINGVEG.EXISTINGVEG.EXISTINGPATHEXISTINGLAWNEXISTINGPATH271 SF EXISTINGFIELD STONEWALLEXISTINGLAWN50' FROM TOP OFCOASTAL BANK100' FROM TOP OFCOASTAL BANKPROPERTYLINE50' FROM TOP OFCOASTAL DUNE100' FROM TOP OFCOASTAL DUNETOP OFCOASTALBANKTOP OFCOASTALDUNE50' FROM TOP OFCOASTAL DUNE100' FROM TOP OFCOASTAL DUNE50'-0" BUILDING SETBACK EXISTINGSEPTICSYSTEMEXISTINGEDGE OFLAWNEXISTING TREETO BE REMOVEDEXISTINGGARAGEEXISTINGLAWNEXISTINGVEG.EXISTINGVEG.EXISTINGTREE7,082 SFEXISTINGLAWNmulcahydesigngroup@gmail.comMULCAHY DESIGN GROUP 2020.THIS DRAWING AND ALL INFORMATION CONTAINEDHEREON IS PROPRIETARY INFORMATION OF MULCAHYDESIGN GROUP. AND MAY NOT BE COPIED ORREPRODUCED, EITHER IN WHOLE OR IN PART, BY ANYMETHOD, WITHOUT WRITTEN PERMISSION OFMULCAHY DESIGN GROUPScale:774.272.2074Drawn By:Sheet:DescriptionDateNum.Revisions:Date:mulcahydesigngroup@gmail.comMULCAHY DESIGN GROUP 2020.THIS DRAWING AND ALL INFORMATION CONTAINEDHEREON IS PROPRIETARY INFORMATION OF MULCAHYDESIGN GROUP. AND MAY NOT BE COPIED ORREPRODUCED, EITHER IN WHOLE OR IN PART, BY ANYMETHOD, WITHOUT WRITTEN PERMISSION OFMULCAHY DESIGN GROUPScale:774.272.2074Landscape Architecture Drawn By:Sheet:DescriptionDateNum.Revisions:Date:L3.0mulcahydesigngroup.comHardscapeCoverageCalculation Plan1"=20'-0"TMNorth:0SCALE: feet2040601" = 20'EXISTING HARDSCAPE COVERAGE CALCULATIONWITHIN THE 50' -100' RESOURCE AREA PROPOSED HARDSCAPE COVERAGE CALCULATIONWITHIN THE 50' -100' RESOURCE AREA COVERAGE CALCULATION WITHIN 50-100'BUILDINGEXISTINGPROPOSED2,661 SFEXTERIOR HARDSCAPE271 SF1,427 SF1,775 SFTOTAL2,932 SF3,202 SFDELTA+270 SFMITIGATION PLANTING WITHIN 50-100'LAWN7,082 SF7,050 SF41 Uncle Roberts Rd, West Yarmouth MA Fairbanks ResidenceDIGITAL AUTOCAD BASE INFORMATION PROVIDED BY:PAUL SWEETSER PROFESSIONAL LAND SURVEYORP.O. BOX 1146 DENNISPORT MA 02639DELTA-32 SF·TOTAL INCREASE IN HARDSCAPE COVERAGE = 270 SF·TOTAL DECREASE IN LAWN = 32 SF·PROPOSED MITIGATION PLANTINGS FOR ALL HARDSCAPECOVERAGE & ALL DISTURBED AREAS = 2,765 SF·1 EXISTING TREE GREATER THAN 6" DIAMETER TO BE REMOVED.MITIGATE WITH 3 PROPOSED NATIVE DECIDUOUS TREES AT 10' HT.TOTAL05/02/23Outdoor Kitchen 10/05/231.