Loading...
HomeMy WebLinkAboutLVL SPECS 122922 S Bels Cascade'�T5 Double 1-3/4" x 18" VERSA-LAM® LVL 2.1E 3100 SP ENGINEERERB01 (Roof Flush Beam) BC CALL®Member Report Dry 11 span I No cant. December 29, 2022 Os Build 8435 Job name: 11 Danbury Street File name: Address: 11 Danbury Street Description: City, State,Zip: South Yarmouth, MA Specifier: Customer: Ferullo Designer: Kevin Lonkart Code reports: ESR-1040 Company: Mid Cape Home Centers 0 12 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 22-00-00 k B1 B2 Total Horizontal Product Length=22-00-00 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead Snow Wind Roof Live B1, 3-1/2" 2016/0 3630/0 82, 3-1/2" 2016/0 3630/0 Load Summary Live Dead Snow Wind Roofv Tributary Lie Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self-Weight Unf. Lin. (lb/ft) L 00-00-00 22-00-00 Top 18 00-00-00 1 Roof Unf.Area(Ib/ft2) L 00-00-00 22-00-00 Top 15 30 11-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 29771 ft-lbs 55.5% 115% 4 11-00-00 End Shear 4726 lbs 34.3% 115% 4 01-09-08 Total Load Deflection L/346 (0.748") 52.1% n\a 4 11-00-00 Live Load Deflection L/537 (0.481") 44.7% n\a 5 11-00-00 Max Defl. 0.748" 74.8% n\a 4 11-00-00 Span/Depth 14.4 %Allow %Allow Bearing Supports Dim.(LxW) Value Support Member Material B1 Wall/Plate 3-1/2"x 3-1/2" 5646 lbs n\a 61.4% Unspecified B2 Wall/Plate 3-1/2"x 3-1/2" 5646 lbs n\a 61.4% Unspecified Cautions For roof members with slope (1/4)/12 or less final design must ensure that ponding instability will not occur. For roof members with slope (1/2)/12 or less final design must account for Rain-on-Snow surcharge load. Notes Design meets Code minimum (L/180)Total load deflection criteria. Design meets Code minimum(L/240) Live load deflection criteria. Design meets arbitrary(1")Maximum Total load deflection criteria. Design based on Dry Service Condition. BC CALC®analysis is based on IBC 2009. Calculations assume member is fully braced. ®Ica Double 1-3/4" x 18" VERSA-LAM® LVL 2.1E 3100 SP PASSED ENGINEERE D WOOD PRODUCTS RB01 (Roof Flush Beam) BC CALC®Member Report Dry I 1 span I No cant. December 29, 2022 09:31:13 Build 8435 Job name: 11 Danbury Street File name: Address: 11 Danbury Street Description: City, State,Zip: South Yarmouth, MA Specifier: Customer: Ferullo Designer: Kevin Lonkart Code reports: ESR-1040 Company: Mid Cape Home Centers Connection Diagram: F ull Length of Member rib .,r d —pim- a c • • I_— •• • -IN- e L.,_ a minimum = 1-3/4" c= 14-1/2" b minimum =6" d =24" e minimum = 1" Calculated Side Load =0.0 lb/ft All FastenMaster screws may be installed from one side of multiply Versa-Lam beams. Connectors are: FMFL312 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement(EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call(800)232-0788 before installation. BC CALC®, BC FRAMER®,AJSTM, ALLJOIST®, BC RIM BOARDTM, BCI®, BOISE GLULAMTM,BC FloorValue®, VERSA-LAM®,VERSA-RIM PLUS®, Page 2 of 2