SEWAGE PLAN REVIEW CHECKLIST
Location A.M. Lot -L( Zone of Contribution: In- Out Acreage
Street: Commercial: Residential: y`
StrVileet:
2 / 'r s%t-iryQ I� - --
a"' �'\ Floor Plan: ,.-- # Bedrooms:
Owner: fr,,.)uc t Tici t,vi ZIP Installer: /� , n l
Address: /) ��:x -/i ah 1 Phone: �1 tt �1 f �x e.4v4.14 1 5e,pi
Phone:
Builder:
Address: Engineer. �,�ovA lti� k sn L
Phone: Phone: 5-6,15-4/-77 J)py
1. Required#of copies received N/A YES I NO
2. Date of soils exam and percolation test not older than 2 years -
3. 4-5 ft of naturally occurring pervious material, above water table -- -
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: -
5. Water ine 10 ft from septic components Var.: -
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic 'ank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands
Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: ,.
11. Tank/leaching minimum 10 ft from property line Var.: V
i 12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: V
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil (A,B horizons) or 5' removal
16. Proposed contours are suitable I V
17. System meets slope requirements- min. 1/8", %"preferred
/
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee V
20. Sewage is under 10,000 gpd for parcel
21. No garbage disposal
22. System r dequately sized for its intended use /
23.Minimum 6"stone or compacted below tank and dbox I
24. Manhole covers within 6"of grade, pump chamber cover to grade t/
25. Inspection port on plastic chambers/leach field
26. Electrica permit for pump chamber/Separate meter for duplexes
27. Pump syitem-2"line,weep hole,check valve, tee in dbox,pump sizeV
,�28. Septic tank/pump chamber to be factory waterproofed
29. Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for-tank/pump chamber
31. Engineer to inspect and certify soils: wall: commercial: I ✓
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature
35. Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow:
37. Check area lots for groundwater/Label groundwater in Assessor's Map gpd
Plal reviewed by: Ar/0 aQ /