HomeMy WebLinkAboutDuct Leakage test BLDSM-22-05715 -00�7 RECEIVED JUN 28 2022 4Ci �� BUILDING DEPARTMENT By: TARGET INSPECTIONS SUMMARY OF TOTAL DUCT LEAKAGE TESTING RESULTS FOR: Ryan Fletcher Site Located at: , ..6 Pine Street Yarmouth Port, MA Project Number: 112E Duct Test Report Version: 1.0 target inspections Steven Grevelis P.O. Box 444 West Dennis, MA 02670 Phone: (888) 280-2108 Email: steve@targetinspections.com www.targetinspections.com Certified HERS Rater (RIN —4958795), BBRS Approved Third Party Tester (Documents Available on Request), & Microbial Professional Enclosures: - Summary of Results - Calibration Data PASS Based on testing of the total duct systems, the observed total duct leakage at the time of testing of the system was at or below the allowable limit (4 cfm per 100 sq ft) as set forth in IECC 2018 with tested results of 2.72 cfm per 100 sq ft. Target inspections Summary of Tesyinq Results t neright 201012011 Page 1of5 TAR(FT INSPFrTiANS Testing Conditions June 3rd, 2022 Wind — N 8 MPH Weather—Cloudy Outdoor Temperature — 62° F Outdoor Relative Humidity—84% i Barometric Pressure —29.70" Target Inspections Summary of Testing Results Copyright 2010:2C Page 2 of 5 TARGET INSPECTIONS Total Duct Leakage Test Test Date: 06/03/2022 Technician: Steven Grevelis Test File: 112E Fletcher 16 Pine St Yarmouth Port Duct Building Address: 16 Pine Street Yarmouth Port, MA Equipment Used Retrotec— DU-200 Duct Blaster w/ DM32 Manometer Serial Numbers: FT9010674/404468 DM32 Factory Calibration Date: 10-23-2020 DM32 Next Factory Calibration Date by: 10-23-2025 Field Calibration of DU-200 Performed: 03-23-2022 Tubing Integrity Testing Performed on Site The home has 1 system outside of conditioned space that was tested: Test Results In accordance with IECC 2018 the maximum allowable total duct leakage is 4 cfm per 100 sq ft at+/- 25 pa in the rough or final stage. Currently MA Stretch Code Towns must meet the same requirements. Square footage of conditioned space is 1,059 square feet: - Maximum allowable leakage of 4 cfm per 100 sq ft=42.36 cfm: (4 cfm x 1,059 sq ft/ 100 sq ft = 42.36 cfm) System #1—Servicing the entire conditioned space- - Tested total duct leakage was 28.76 cfm @ -25 pa Total duct leakage was 28.76 cfm = 2.72 cfm per 100 sq ft cfm = cubic feet per minute pa = pascals sq ft=square feet Target inspections Summary of Testing Results Cone+rsrht 2010'2011 Page 3 of 5 TARGET INSPECTIONS Conclusion Based on testing of the total duct systems,the observed total duct leakage at the time of testing of the system was at or below the allowable limits (4 cfm per 100 sq ft) as set forth in IECC 2018 with tested results of 2.72 cfm per 100 sq ft.The total duct leakage was 28.76 cfm = 2.72 cfm per 100 sq ft. The system as installed meets the recommended guidelines and no further sealing is required. Note 1: Square footage provided by Ryan Fletcher. retro -1 gipxI-Sb.+. tO.M • x yy -264 ll".I,M _ r toR 28, 6 (.4 PHOTO SUMMARY PHOTO SUMMARY Setup of the tested system. Manometer reading of the tested system. Target Inspections Summary of Testino Resutts Cnoyrinht 2010'2011 Page 4 of 5 1 Q�� TARGET INSPECTIONS This inspection report is solely based on the conditions within the defined area at the time of inspection only and makes no express or implied warrant or guarantee as to future changes in condition or conditions outside of the described job scope. Sincerely, 2 Steven G revel is Certified HERS Rater(RIN—4958795), &Certified Microbial Professional Target Inspections Summary of Tesbno Results Comvnaht 2010 2011 Page 5 of 5