Loading...
HomeMy WebLinkAboutEngineer PlanSTRIPOUT BOUNDARY TO "B" HORIZON INSTALL A 40 MIL POLY LINER TOP OF LINER, EL.=102.2 BOTT. OF LINER, EL.=98.2 c5 9833 Q_ i x 98.56 m EXISTING S.A.S. — PER RECORD AS —BUILT TO BE REMOVED (SEE NOTE 10) PROPOSED PUMP CHAMBER — 1000 GALLON EXIST. SEPTIC TANK TOP, EL.=99.70 INV. (OUT), EL.=98.35t BENCHMARK THRESHOLD EL. =107. 70 x 98,35 \99.54 x 98.64 CB 99.94 L ,07 99.62 AFAWA . • 4 , EXISTING SHED TO BE RELOCATED OR REMOVED PROPOSED S.A.S. 18' x 25' FIELD x 99 82 EXISTING a\ 'FHCOUSE(1127) 100 "'' u 99 OVv PK SET J�� %ELMIM 1 LEGEND 4C" T _ Y� x 100.98 EXISTING SPOT GRADE ;r oab -- 10 -- EXISTING CONTOUR —W EXISTING WATER SERVICE Aecwr a � �m � o� -- EXISTING GAS SERVICE NEST r an — t OVERHEAD WIRES 33 ; GROW VXKSWW no TEST PIT z OMAT MAP RDWM t---1 $ BENCHMARK Y�7 YIW/9WW n c� LOCUS a i� CINGtMT N 1 \ Ad MUST LOCUS MAP GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: —310 CMR 15.405(1)(h): 1) A 1' reduction to the required 5' separation between maximum seasonal high groundwater and bottom of S.A.S., for 4' sepataion. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. rypQp Ron # ALL ELEVATIONS BASED ON AN ASSUMED DATUM. j1� THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF VV I THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF 1_ 7 HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. n Date THERE ARE NO PRIVATE WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. ii1LL=��/L 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING OCT ?�Za CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS 100.24 IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND HEALTH DEPT. REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 00.18 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY HEALTH DEPARTMENT OR DESIGNER PRIOR TO BACKFILL. 13. CONTRACTOR SHALL OBTAIN AN ELECTRICAL PERMIT PRIOR TO BEGINNING O THE INSTALLATION. o PETER T. �, 14. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND V-MCENTEE IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY. U CIVIL`/3 No. 35109 MAP ID: 48-4 OWNER OF RECORD DEVROUDE, JOHN D & BRADLEY C TR DEVROUDE FAM IRR R E TR C/O MR & MRS JOHN P DEVROUDE 325 LONG HILL ROAD BOLTON, MA 01740-1420 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 237 WINSLOW GRAY ROAD, WEST YARMOUTH, MA Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 Engineers: Engineering Works, Inc. 12 West Crossfield Road Forestdole, MA 02644 (508) 477-5313 Surveyors: Richard J. flood PL5 12 Settlers Path Sandwich, MA 02563 (508) 246-6260 SCALE 1"=20' DRAWN P.T.M. JOB. NO. 209-23 DATE 9/20/23 CHECKED P.T.M. SHEET N0. 1 Of 3 EXISTING SEPTIC TANK & NOTE: TO PREVENT BREAKOUT, INSTALL A 40 MIL PROPOSED PUMP CHAMBER POLY LINER AS SHOWN ON SHEET 1. PROPOSED S.A.S. PROVIDE RISERS & COVERS AS DESCRIBED: TOP OF LINER, EL.=102.2 18' x 25' FIELD 1) INLET COVER SET TO 6" OF GRADE. BOTT. OF LINER, EL.=98.2 2 20" OUTLET COVER SET TO GRADE PROPOSED D-BOX INSTALL WATERTGHT RISER & PROPOSED S.A.S. MANHOLE COVER SHALL BE SECURED TO PREVENT UNAUTHORIZED ACCESS. COVER SET TO 6" OF GRADE INSTALL ONE INSPECTION PORT (MIN.) F,G. EL.=100.8t F.G. EL.=103.0(MIN.) to 103.4 F.G. EL.=100.5t F.G. EL: 103.4t pOVIDE ENOUGH WIRE MAINTAIN 2% GRADE MIN. OVER S.A.S. CK TO REMOVE PUMP (MIN.) \ �a _ S=1%2MIN. (MIN.) TOP EL.=99.6 4" DIAM. INSPECTION PORT, L 7'(MAx)13' x 25' LEACHING FIELD W/2-4" PERFORATED IN S.A.S., SOLID p�G ®S=1% (MIN.) 4 P F P DISTRIBUTION ABOVE S.A.S., WITH SCREW CAP 40f goCKS 4'SCH4D PVC SET TO WITHIN 3' OF GRADE. \ �� O 4� �91 4"SCH40 PVC BEND CAPPED ENDS O. 6" e � 6" EFF.DEPTH W 3 14..10' INV. EL.=101.70 END INV.=101.90 I SLOPE OF PERF. PIPE = 0.5% I ( ) FINV.=102.07 25' EFFECTIVE LENGTH�'PROPOSED INV.=98.28EFFLUENT 2 FLOATS3 D-BOXSOIL ABSORPTION SYSTEM (PROFILEADD OUTLETS (MIN.)FILTER USE OUTLET 98.7t INV.=101.83 KNOCK OUT W. EL.=94.8 EXISTIN MkBOTT. EL.=93.9/ ADJ. G.W. SEPTIC TANK 1000 GALLON MONOLITHIC G.W. EL.=97.1 1EXISTING INV.=98.35 PUMP CHAMBER (H-10 RATED) ESTABLISH VEGETATIVE COVER HOUSE(#237) EXISTING (See Pump Detail, Sheet 3) T.O.F.=100.9t (FIELD VERIFY) FINISH GRADE F-EL.=103.0 to 103.4-� NOTES: 1) PUMP CHAMBER & D-BOX SHALL BE SET LEVEL AND TRUE r„ .:-a APPROVED TO GRADE ON A MECHANICALLY COMPACTED 6" CRUSHED BREAKOUT ELEV.=102.2 "" '' " FILTER FABRIC STONE BASE, AS SPECIFIED IN 310 CMR 15.221(2). 2) INSTALL INLET & OUTLET TEES AS REQUIRED. BOTTOM ELEV.=101.20 3/4"-1 1/2" DOUBLE 3) MAX. COVER OVER SEPTIC TANK, D-BOX & S.A.S. SHALL BE 36". 4' (MIN.) ABOVE G.W. 3.5 6 3.5' WASHED STONE 4) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE INVERTS PRIOR TO CONSTRUCTION. WITH VARIANCE 4' OF NATURALLY OCCURRING 13' EFFECTIVE WIDTH /� S.A.S. LAYOUT 5) EFFLUENT FILTER SHALL BE INSTALLED ON OUTLET PERVIOUS MATERIAL SOIL ABSORPTION SYSTEM (SECTION) TEE AS MANUFACTURED BY ZABEL OR EQUAL. FILTER EST. HIGH G.W. EL: 97.1 SHALL BE INSPECTED AND CLEANED ANNUALLY. SEPTIC SYSTEM PROFILE Index Well Readings SOIL LOG (feet below surface) DESIGN CRITERIA DATE: AUGUST 2, 2023 SOIL EVALUATOR: PETER McENTEE PE(SE#1542) ao+9 zozo zoa+ z�zz NUMBER OF BEDROOMS: 2 WITNESS: BARRY LEWIS HEALTH AGENT e, F-y March W1 May ELEy. T P -1 DEPTH ELEv. T P -1 DEPTH SOIL TEXTURAL CLASS: CLASS 0„ 0„ zozs WNI ID wl Redne Pleading Zone A Zo8 2one C 2.ne Z.-D 2.E C WN, DESIGN PERCOLATION RATE: <2 MIN/IN 99 6 A/E 99 6 A/E Barnstable 231 AIW231 �a 26.7 1.3 1.7 2.6 3.5 3.9 *ea-23, LOAMY SAND LOAMY SAND Samstable247 aw247R 'b 26.1 2.8 4.2 5.6 7.0 m OB°'"-2`7 DAILY FLOW: 220 GPD 10YR 4/2 10YR 4/2 98.8 98.8 Bourne198 BHW198 33.3 c olk-196 Brewster 21 BMW21R tb 11.0 2.4 3.6 -20 DESIGN FLOW: 220 GPD 1 0„ 1011 B B Chatham 138 CGW138R 2 27.9 25 3.8 5.1 63 0Ca-, 3E GARBAGE GRINDER: NO STRIPOUT TO LOAMY SAND pERC LOAMY SAND pERC "B" HORIZON 10YR 5 8 10YR 5 8 / / Mashpeez9 Miw29 ob 9.t 23 3A 4s 57 to sandw:chz53 SDW252R Rl 1.6 .o ,. .. LEACHING AREA REQUIRED: (220 GPD) = 297.3 SF 12'/3D" 12 /30 49.0 sandwich253 sDW253R 0 49.0 3.5 5.3 7.1 4 -40 5.3 71 esr4-253 96.8 34" 97.0 311, Weh8eet17 WNW17R ob 12.1 2.1 27 4.1 �1N,ae9 .74 GPD/SF C C ,�,+c +"f r� s EXISTING SEPTIC TANK: 1000 GALLON CAPACITY Month PROPOSED PUMP CHAMBER: 1000 GALLON CAPACITY, H-10 PROPOSED SEPTIC SYSTEM UPGRADE PLAN PROPOSED D-BOX: 1 INLET, 3 OUTLET (MIN.), H-10 MED. SAND MED, SAND 2.5Y 6/4 2.5Y 6/4 INSTALL AN 13' X 25' LEACH FIELD 237 WINSLOW GRAY ROAD, WEST YARMOUTH, MA SIDEWALL AREA: NOT APPLICABLE 97.1 ADJ. G.W. 97.1 ADJ. G.W. - Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 BOTTOM AREA: 13' x 35' = 325 S.F. 94.8 STG. G.W. - 57" 94.8 STG. G.W. - 57" T T Engineers: Surveyors: SCALE DRAWN JOB. NO. 93.3 76" 94.6 60' TOTAL AREA: .................................... 325 S.F. STANDING G.W. AT EL.=94.8, INDEX WELL MIW-29, ZONE A Engineering Works, Inc. Richard J. Hood PL5 N.T.S. P.T. A. 209-23 LEACHING CAPACITY = 0.74 GPD/SF x 325 SF = 240.5 GPD WATER LEVEL=9.1 (AUGUST 2023), ADJUSTMENT=2.3 ESTIMATED HIGH G.W., EL.=97.1 12 West Crossfield Road Forestdole, MA 02644 12 Settlers Path Sandwich, MA 02563 DATE CHE�KED SHEET N0. PERC RATE <2 MIN/IN. ("B" HORIZON) 1 (508) 477-5313 (508) 246-6260 9/20/23 P.T.M. 2 Of 3 NEMA 4 JUNCTION BOX CORROSION RESISTANT & LIQUID -TIGHT CABLE CONNECTORS SUPPORTED PROVIDE WATERTIGHT CONCRETE RISER WITH BY 1-1/4" PVC CONDUIT. JOINTS TO BE MADE SECURED FRAME & COVER TO GRADE WATERTIGHT. USE SJE RHOMBUS-JB PLUGGER OR EQUAL. PROVIDE ENOUGH WIRE SLACK TO REMOVE PUMP INSTALL 1' PVC CONDUIT TO HOUSE FOR WIRING HOISTING CABLE 709 STAINLESS STEEL WITH WATERTIGHT JOINTS. WIRE HIGH WATER ALARM 1/8" DIAMETER. f 1,760 L.B. STRENGTH. FLOAT TO SJE RHOMBUS TANK ALERT XT ALARM PANEL PROVIDE ENOUGH WIRE ON CIRCUIT SEPARATE FROM CIRCUIT TO THE PUMP. A ME-SHOREY NorEs: R1B47CiDtat7tli'8FY06uCh� SLACK TO REMOVE PUMP INV.(IN)=98.28 2" BALL VALVE (FIELD ADJUST FOR 20 GPM RATE) (INSTALL QUICK DISCONNECT FOR EASY REMOVAL) 1.)SEAM SEALED WITH FLEXIBLE 2"SCH. 40 DISCHARGE (THROUGH RISER -SEE PROFILE) BUTYL RUBBER SEALANT. ALARM ON EL: 95.80 2" 90' ELBOW W/ 1/4" WEEP HOLE PUMP ON EL: 95.30 FOR SELF -DRAINING FORCE MAIN BOTTOM OF PUMP OFF EL: 94.97 18 1'2» 2" SWING CHECK VALVE B.. PUMP CHAMBER 1 8" 2" SCH. 40 PVC DISCHARGE PIPE (1)021"CONCRETE COVER ELEV.= 93.97 ADDITIONAL 3/16" VENT HOLE (MIN.) ABOVE PUMP FLANGE PROVIDE 2 FLOATS: 4" (TO PREVENT PREMATURE PUMP BURNOUT) FLOAT NO.1: PUMP ON/OFF-SJ RHOMBUS (PROVIDED WITH PUMP) I t (1)030'ACCESS OPENING FLOAT NO.2: ALARM ACTIVATION FLOAT -PROVIDED WITH ALARM PANEL (ON SEPARATE CIRCUIT FROM PUMP SPECIFIED) LIBERTY LE40 SERIES PUMP .4 H.P. 115 V WITH 2" DISCHARGE, OR EQUAL I i i t 3'-5' PUMP AND ACCESSORIES AVAILABLE AT: CAPE COD WINWATER WORKS CO., HYANNIS, MA. (508) 862-0166 NOTE: APPROVED ALTERNATE MAY BE SUBSTITUTED. I I PUMP DETAIL J (3) 04" INLET (3) 04' OUTLET 'POLYLOK III BOOTS' 'POLYLOK III BOOTS' DOSING & STORAGE REQUIREMENTS A ME- HOREY NOTES. 1.) COMPLIES TO CODE 310 CMR 15212 DESIGN FLOW: 220 GPD - 121n- 8'-3• 5'-5'-------{ a� DOSING REQUIRED: 4 CYCLES/DAY (SAND)17,n 220 - 4 = 55.0 GALLONS/CYCLE I AVAILABLERISEfWt I 17 DISTANCE REQUIRED BETWEEN PUMP ON AND PUMP OFF FLOATS: ---_�, Incki I' - ,I �----121r2in -� I 55.0 GAL/CYCLE 250 GAL/FT = 0.25 FT/CYCLE (USE 4") It�"-'I $'817inta-10- ]0- STORAGE REQUIRED ABOVE WORKING LEVEL: 220 GALLONS PROVIDED: --12in-.IT :�-_j INVIN 4'-4"STORAGE INVOUTINV.(IN) EL: 98.28 - PUMP ON EL: 95.30 = 2.98' �:,1 �__-__-1 1 ,5„ STORAGE PROVIDED = 2.98 x 250 GAL/FT = 745.0 GALLONS VA IL BLERI (9)04"INV OUT 1 W,170U ' WL . 170 Lbs I POLYLOK SEAL' 1 (w I,) I p'-'3" 0'-4" I POLYLOK SEAL � �•-13In--{ I It)13K' INV IN I __-_. ,� i' 17in (INNER) (INNER) PUMP CHAMBER SHALL BE WATER PROOFED NAME: PUMP CHAMBER,1000 Gallon,MONO H-10 ITEM# PCIOM30 BUOYANCY CALCULATIONS 1000 GALLON MONOLITHIC PUMP CHAMBER L pin Concrete Minimum Strength. 4,000p.s.i.at28days Steel Relntorcrnent:ASTM A815, Grade 80 TOP 2,200 Lbs $ DATE:9-24-2017 Ch 2 P 22 Sht2 of 2 �- Design Loading: standard unds - AASHTO - H10 gn BOTTOM 6,000 Lbs BOTTOM OF UNIT EL.= 93.97 13in HIGH GROUNDWATER EL.=97.1 BUOYANCY FORCE PER FOOT OF DEPTH: ,eln rl 0 1 I is in PROPOSED SEPTIC SYSTEM UPGRADE PLAN ' x 5.4' x 1' x 62.4 lbs. Cu.ft. = 2796.8 lbs. /0 en f MAX. DISPLACEMENT = 97.1 - 93.97 = 3.18' sin 8O ( 1 2.37 WINSLOW GRAY ROAD, WEST YARIVIOUTH MA MAX. UPLIFT PRESSURE = 3.13' x 2796.8 Ibs/ft = 8753.9 Ibs. un IN _% L. IHvo� t_----------�- WEIGHT OF UNIT EMPTY = 8,250 Ibs. 12in Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673 WEIGHT OF 1' OF COVER = 8.3' x 5.4' x 110 PCF = 4930.2 Ibs. ._ t7in--- Engineers: Surveyors: SCALE DRAWN JOB. NO. WEIGHT = 8250 Ibs. + 4930 Ibs. = 13,180 Ibs. NAME: DISTRIBUTIONBOX,3OUTLETS H-10ITEM#DB3 Engineering Works, Inc. Richard J. riood PL5 N.T.S. P.I.M. 209-23 13,180 Ibs. > 8754 Ibs. O.K. 12 West Crossfie0 Road Forestdole, MA 02644 12 Settlers Path Sandwich, MA 02563 co -ores r.•st,�-9I a uee Ps . a128 days TOP so Lbs CH DATE:11.21-2019 DATE CHECKED SHEET NO. cna P 1.1 srn2or2 eorronn 210 Los (508) 477-5313 (508) 246-6260 9/20/23 P.T.M. 3 Of 3