HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location A.M. Lot 6r,0/,,2 Zone of Contribution: In Out Acreage Commercial: Residential: �Ains C ------- Street: Village: tJ esk ye s � 4- Floor Plan: #Bedrooms: , r )Owner: 4.Po , Lri u+"e, 6ci 5 vl i-2.r- Installer: t ; r Address: Phone: Phone: 5-,= ) %f f �� 0 Builder: Engineer: C et, �r , Address: , rPt y c'''�r��� Phone: Phone: 77 y_ ,„93g i; i3 1. Requi ed#of copies received N/A YES NO 2. Date o soils exam and percolation test not older than 2 years 3. 4-5 ft i f naturally occurring .ervious material, above water table - - - 4. Found.tion 2 ft above high .oint of road 5. Water inc 10 ft from septic components Var.: End: Var.: 6. Benc ark indicated and shown-NGVD if near wetlands " 7. Septic ank minimum 10 ft from foundation, deck Var.: 8. Leachi. g minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leac • • minimum 100 ft from wetlands Var.: 10. Leachi g minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/1-.ching minimum 10 ft from property line Var.: 1 12. System meets all other setback requirements Var.: 13. Uses a.rustment for maximum high groundwater Var.: 14. Leac ' a set 4-5 ft above ad". water or bottom of test hole Var.: 15. System of in top or subsoil (A,B horizons)or 5' removal _ 16. Propos-. contours are suitableI 17. System eets slope requirements- min. 1/8", 'A"preferred 18. System eets breakout requirements PVC liner: Wall: I 1111� 19. Specifies tee sizes are proper, gas baffle on outlet tee 20. Sewage s under 10,000 gpd for parcel V 21. No garb„ge disposal • �/ 22. System .de uately sized for its intended use 23. Minimu . 6"stone or compacted below tank and dbox t/ 24. Manhol:covers within 6"of grade, pump chamber cover to grade ✓ `.7 25. Inspecti.n port on plastic chambers/leach field 26. Electrica permit for pump chamber/Separate meter for duplexes 27. Pump sy"tem-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic to i 'um. chamber to be factory waterproofedLZ- 29. Vent pro• 'ded if leaching below 3 feet,under driveway/parking / 30. Buoyanc calculations for tank/pump chamber 31. Engineer to ins.ect and certify soils: wall: commercial: V • 32. Engineer►'egistered Sanitarian and Land Surveyor stamps/signature I L j 33.H-201oa•ing is subject to vehicular traffic, groundwater 34.Title V A.plication and permit fee, installer signature 35. Foundati.n footing min. 2 feet above adjusted ground water for new house 36. Deed Res 'ction re.uired max. #bedrooms: max. flow: gpd ✓ 37. Check ar : lots for _ oundwater/Label groundwater in-Assor's Map , Pia reviewed by: f U_`,V-a-3 V