Loading...
HomeMy WebLinkAboutEngineer PlanPermit valid for REPAIR OFJ TIC SVST ONLY, due to State and Loc l s ptic varian Board of Health review and appro I is required any future additions/renovatio alterations sewage facilities and/or structures/ elling. Yarmouth Health Den eat BUTTING WELLING #1 & #3 TRENTON ST 28/59 town water 98 �' if a 'a e a a. CONCRETE PAD n a n j E FIRRSTST FLC > meter LEGEND "YARMOUTH #0 ROSETTA ST 8 ApproxiiY atenllocation war 28/51.1.1 4&.-.. Existing contour ' f 1 L Existing 1,000 gol. H-10 loading eptia tank 62.00 —1 �to be pumped and removed) i Existing Leach facility COE 10' (to be pumped and removed) HOSPITAL 5 C----...--- 101.70' X Denotes existing spot grade e t 1 TRACK TO WETLANDS o C.O. Clean Out — - T Denotes existingseptic components ® Denotes proposed septic -----_�` 10' components C ;0. CONCRETE WALK 101.64' PORCH 0 me- J6191MI 0 o O KISTING 40 MIL LINER O DO 0 10 �2 DIRT DRIVEWAY , ^. CCT14AP.K T6IWETLAND ��.I11I `Q..concrete wotk- y. ......PAVED APRON ' 99 edge of povemenf TRENTON STREET I TE 4---� --o-- Existing 2' Pickett fence GENERAL NOTES LOCUS 1. 2. ADDRESS:15 TRENTON STREET, YARMOUTH, MA, ASSESSOR'S NUMBER: MAP 28 PARCEL 60. NO SCALE O O O Proposed 2,500 gal H-20 3. c1 DEVELOPER'S LOT: LOT #313 AND PART OF '2. septic tank/pump chamber 4. TOPOGRAPHIC INFORMATION WAS COMPILED F OM AN ON THE GROUND INSTRUMENT SURVEY. 5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES. 6. WETLANDS WERE LOCATED BY ENGINEERING WORKS, INC. PLAN FOR 7 TRENTON ST, DATED 2/27/21. 7. REFERENCE PLAN: PLAN BOOK 26 PAGE 103, PLAN BOOK 276 PAGE 75, PLAN BOOK 83 PAGE 45-2. "PROPOSED SEPTIC SYSTEM UPGRADE PLAN, 7 TRENTON STREET, SOUTH YARMOUTH, MA. PREPARED FOR BRENDAN McNAMARA, 230 RANCHO SANTA FEv ROAD, CA., 92024." PREPARED BY ENGINEERING WORKS, INC., SCALE 1 =20. DATED 2/27/21. "PLOT PLAN, PROPOSEDSEPTIC SYSTEM UPGRADE, PREPARED FOR MRS. OE. , �j TRENTON0' STREET, PLAN SHAYTS BYRCARMENLENE D SCALE DATED OCTOBERH6,M2006.REPARREVISE SITE OCTOBER 20, 2006. SCALE: 1 " = 1 O ' 8. 9. UTILITIES LOCATED BY DIGSAFE. THIS DESIGN PLAN IS TO BE UTILIZED FOR THIS SEPTIC REPAIR ONLY. 10. EXISTING SEPTIC COMPONENTS SHOWN PER 07-26-2021 SEPTIC INSPECTION. B M = 9 9.2 9 ' (ASSUMED) 1 1 THEX MINIMAL FLOOD HAZARD ZONE RTY LOCATED INOTED NE PROPEPANEL . . 25001 CO569JA DAIS PER FIRM 7/16 '20 4 12. ON P K NAIL SET 11 THE PROPERTY IS NOT LOCATED IN A GOR WP ZONE. . . 13. )FOR THE PROPERTY IS NOT LOCATED IN ANZONE AREA CRITICAL ENV ORNMENTAL CONCERN. 99 14. THE PROPERTY IS NOT LOCATED IN A NATURA_ HERITAGE AND ENDANGERED SPECIES PROGRAM AREA. RECEIVED OCT 10 2023 HEALTH DEPT. PROPOSED SAS -ive H-20 500 ggallon concrete chambers in a 33'x32' "L—shaped" leaching trench #7 Trenton St 28/61 town water P.K. NAIL SET 15SOIL EVALUATION TO BE PERFORMED BY SOIL EVALUATOR AT TIME OF INSTALI . VARIANCES 1.) 310CMR15.211/405.1.A— A variance is requested to allow the proposed SAS to be constructed 1' to a property line in lieu of the required 10'. 2.) 310CMR15.211/405.1.B— A variance is requested to allow the proposed SAS to be constructed 10' to to the existing cellar wall in lieu of the required 20'. PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR T.L.H. EXCAVATION AT #5 TRENTON STREET YARMOUTH, MA PREPARED BY: A Per f'ec t En viror7men t L L C dba Geo—Cape Environmental Consultants 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 Tel: 774-238-1813 Email: aperfectenvironment®gmail.com SCALE: 1 "=10' DRAWN BY: TWH I DATE: 5 OCT 2023 DATUM: ASSUMED FILE: 5TRENTON 6BR I SHEET 1 OF 3 20" DIAMETER 04" PVC COUPLING SECURED COVER TO FINISHED GRADE (' 0'-2 1 /2" GAP (CAST IN BAFFLE) ' t LIFT OUT WLET INVERT TOD" ELEV.- 95.30' 660 GALS PUMP DETAIL Not to Scale ELEV.-98't OLI LET P&M ELEV.-95.30' �/'8- WEEP HOLE MM CHECK VALVE (FREEZE PROTECTION) 2' SWING CHECK VALVE-P.Y.C. HIGH WATER ALARM ELEV.-93.06' PUMP ON ELEV.-92.89' PUMP OFF ELEV.-92.W FLOOR PUMP CHAMBER ELEV.-91.30' PUMP MOTES & SPECIFICATIONS N 1. PROVIDE 1 LIBERTY MODEL LE 41A 4/10 hp, 115 VOLT, SINGLE PHASE SUBMERSIBLE PUMP CAPABLE OF DISCHARGE O O O CAPACITY OF 125 GPM AT 5 FEET TDH, OR EQUAL. PUMP SHALL BE CAPABLE OF PASSING A MINIMUM SOLID SIZE OF 2" DIAMETER OR EQUAL. 2. USE LIBERTY SIMPLEX ELECTRIC CONTROL PANEL OUTDOOR MOUNTED W/VISIBLE ALARM OR EQUAL 3. PUMP SHALL BE INSTALLED IN STRICT COMPLIANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALARM SHALL CONSIST OF AUDIBLE SIGNAL & RED WARNING LIGHT TO BE INSTALLED IN BUILDING AND POWERED BY SEPARATE CIRCUIT FROM CIRCUITS TO PUMP. 5. DOSE VOLUME=4 DOSES PER DAY= 660 GAL/4 DOSES=165 GAL./DOSE 6. ELECTRICAL PERMIT REQUIRED FOR ALARM & POWER TO PUMP. 7. ALL OUTDOOR CONNECTIONS TO BE SEALED WITHIN NEMA 4 ENCLOSURES 8. THE FORCE MAIN SHALL BE 3" DIA. SCH 40 PVC WITH THRUST BLOCKS INSTALLED, AS NECESSARY. 9. INSTALL STAINLESS STEEL SLIDE RAIL SYSTEM AND SIMPLEX DISCHARGE PIPING OR PULL CHAIN OR EQUAL. ALL OUTLET PIPES FROM THE DISTRIBUTION BOX SHALL BE SET LEVEL FOR AT LEAST 2 FT. PLAN —SECTION t2" —'1 ,- CONCRETE COVER 3 - 5" OUTLET KNOCKOUTS — OUTLET t 12" INLET b" g" 3" 3" CROSS SECTION 3 HOLE H-20 DISTRIBUTION BOX NOT TO SCALE 129 ,3 L SAS LAYOUT- PLAN VIEW %. l ,.. KNOCKOUTS 7'-211 5'-9" INV IN RECE�VE� CCT 10 2023 HEp,LTH oepT• (3) 08" OUTLET KNOCKOUTS 5'-0" LIQUID LEVEL 5'-6" INV OUT i A. *NOTE: ALL PIPES ARE TO BE 4" SCHEDULE 40 P.V.C. Existing Dwelling First Floo = Septic tank cover must be within 6' of finished grade WALLAR S = 0.02' ft 11' Ex. Invert Elev, I P=95.55' Existing Invert elevations shall The verified prior to installation work Manhole covers must be secured at finished grade Instnil Zobd 'AfB�. effluent Cee er '. eq. 6" OF 3/4"-11/2" STONE PROPOSED 1,500/1000 GAL. H-20 SEPTIC TANK/PUMP CHAMBER (SEE TANK DETAIL FOR TYPE & DIMENSIONS) SYSTEM PROFILE Not to Scale 3 HOLE H-20 DiST. BOx D-Box cover shall be within 6" of finished grade Finished grade over system=2% slope away Provide 2" SCH 40 PVC tee on inlet 12" min 36" mo III av p< LEVEL FOR 2' S=0.01' =95.80' P=95.1 6" OF 3/4"-11 /2" STONE One chamber cover shall be within 6" of finished grade rmmarmMJt=®` m m� m r CM CONSTRUCTION NOTES 3/4"-1 Double— Stone H 20 1 . Contractor is responsible for Digso#e notification LEACHING CHAMBERS and protection of all underground utilities and pipes. 2. The septic tank and distribution box shall be set level on 6„of 3/4"-1 1 /2" stone. CROSS-SECTION 3. Bockfill should be clean sand or gravel with no stones over 3" in size. 4. This system is subject to inspection during installation by Geo—Cope Environmental Consultants. 5. The contractor shall install this system in accordance with Title 5 of the Massachusetts Environmental Code and local Board of Health Rules and Regulations. 6. if, during installation the contractor encounters any soil conditions or site conditions that are different from those shown on the soil log or in the design, the installer shall halt installation and immediately notify Geo—Cape Environmental Consultants. 7. No vehicle or heavy machinery shall drive over the septic system unless noted as H-20 septic components. 8. All piping shall be 4" diameter SCH 40 PVC unless otherwise specified. 9. No wells are located within 150' of proposed SAS. 10. Provide one 2,500 gallon H-20 low profile septic tank/pump chamber, one DB-3 H-20 distribution box, and five 500—goilon H-20 precost chambers by Acme—Shorey Precast or equal. 11. Existing SAS shall be pumped and removed. All leochate impacted soil shall be removed and replaced with fill meeting 310CMR15.255(3). 12. The designer is not responsible for undocumented septic components. 13. Soil evaluation to be performed by soil evaluator at time of installation. 13 Existing Grade = 99't )ne chamber cover shall be within 6" of —finished qrade i a liftiiw 3/4"-1 " Double —Washed Stone H-20 LEACHING CHAMBERS Min. 2"-1/8"-1/2" Double -Washed Stone or geo-textile (filter cloth Too of SAS=95.42':: 24" 50' Leash Facility Elev.=93.50' 5' Min. (5' Provided) "Adjusted GW Elev=88.50' GW elevation taken from monitoring well at 7 Trenton St by E� i9 neerin Works, Inc. Min. 2"-1/8"-1/2" Double —Washed Stone or geo—textile filter cloth SAS LAYOUT A 1 Top of SAS Scale: 1 "=20' 0 CORNER DWELLING TO CORNER TANK/SAS O Invert Elev. A-1 = 17'—B" B-1 = 38'-3" A-2 = 23'-8" B-2 = 27'-6" 24" A-3 = 30'-6" B-3 = 27'-0" 2 01 Bottom of Leach Facility Elev. RECEIVE6 — 58 —2' B-4 = 20'-0" B-5 = 20'-0" C-4 = 56'-11" 4' C-5 = 27'-11" OCT 10 2023 5' Min. EXISTING DWELLING O ? HEALTH DEPT.. F GW Elev. C � B O Design Calculations Number of Bedrooms: 6 Equivalent to 660 Gal./Day Garbage Disposal: Not allowed with this design Septic Tank Capacity Required: 660 gpd x 200% = 1,320 gpd. Septic Tank Capacity Provided: Proposed 2,500 gallon H-20 septic tank/ pump chamber Leaching Capacity Required: 660 gpd / LTAR= 891 SF Req'd Area LTAR for Class I soil at <5 min./inch = 0.74 gal/sq. ft. Proposed Leaching Structure: One 33'x32' "L"—shaped trench Bottom Leaching Area Provided = 636 sq.Ft. Sidewall Leaching Area Provided = 260 sq. ft. Total Leaching Area Provided = 896 sq. ft. > 891 sq. ft req'd. Leachina Capacity Provided =896 sq. ft X 0.74 gal/sq.ft.=663 gpd O O O 0 PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR T.L.N. EXCAVATION AT #5 TRENTON STREET YARMOUTH, MA PREPARED BY: A Per Fec t Environment L L C dbo Geo—Cape Environmental Consultants 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 Tel: 774-238-1813 Email: aperfectenvironment®gmoil.com SCALE: 1 "=10' DRAWN BY: TWH DATE: 5 OCT 2023 DATUM: ASSUMED FILE: 5TRENTON 5BF SHEET 2 OF 3