Loading...
HomeMy WebLinkAboutEngineer Plan100.49 r\ c� a I � 100.09 m �! co a 0 100.41 100,66 J edge 100,60 t-1 CATCH E BASIN 100,74 101.08 SETUc1KET ROAD a{ 102.48 pavement 10L58 edge N 85.36' 53" E 118.53' LKINGRE-TAZINNG '___ ut pavement AINING WALL - EL. 101.4E• 101.58SPIKE0 2- - Yarmouth ealth Department OVED ---�M Na ate LOT 1 13, 206 f S. F. x x 103.31 102,66 10 3.3 8 EXISTING HOUSE(�29) T.O.F.=103.1t 7/ 102.2211 DECK 98J0 TP- T 21 S8119'53"W 104.36 � 10 4,4 0 LEGEND - - 67 - - EXISTING CONTOUR x 100.98 EXISTING SPOT GRADE ---OHW- OVERHEAD WIRES G EXISTING GAS SERVICE W EXISTING WATER SERVICE TEST PIT lii� BENCHMARK I LOCUS MAP 3 o o M 0 N RETAINING WALL TOP EL. 103.7E j100.26 BENCHMARK GARDEN BSMT. ENTRY SILL N� � EL. = 96.01 o 000 9947= 98.43 SPIKE o PETER T. McENTEE v CIVIL No. 35109 / 20' -RETAINING WALL TOP EL. 100.4E OCT 19 2023 L HEALTH DEPT. OWNER OF RECORD LOUIS JEAN ELIE LAGUERRE LOUIS MARIE MILKA 29 SETUCKET ROAD YARMOUTH PORT, MA 02675 ``EXISTING SEPTIC TANK TOP OF TANK, EL. = 97.59 INV. (OUT)= 96.24E (VERIFY) ---EXISTING S.A.S. TO BE PUMPED & REMOVED SEE NOTE 11 PROPOSED S.A.S. 2-500 GAL CHAMBERS SURROUNDED W/STONE MAP ID: 143-140 PROPOSED SEPTIC SYSTEM UPGRADE PLAN 29 SETUCKET ROAD, YARMOUTH PORT, MA GENERAL NOTES: 1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL BOARD OF HEALTH AND THE DESIGN ENGINEER. 2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW: -310 CMR 15.405(1)(a): LOCAL UPGRADE APPROVAL 1) A 5' variance, distance to property line, for a minimum setback of 5' from the property line. 3. THE SEWAGE DISPOSAL SYSTEM SHALL NOT BE BACKFILLED PRIOR TO INSPECTION AND APPROVAL BY THE BOARD OF HEALTH AND THE DESIGN ENGINEER. 4. ANY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING FROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN ENGINEER BEFORE CONSTRUCTION CONTINUES. 5. ALL ELEVATIONS BASED ON AN ASSIGNED DATUM. 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE. 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S. 9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE DIRECTED BY THE APPROVING AUTHORITIES. 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING CONSTRUCTION. 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3). 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE INSPECTED BY DESIGN ENGINEER PRIOR TO BACKFILL. 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND NOT CONSIDERED TO BE A PROPERTY LINE SURVEY. 14. THE ENGINEER IS NOT RESPONSIBLE FOR ANY UNDOCUMENTED SEPTIC SYSTEM COMPONENTS NOT SHOWN ON THE PLAN Prepared for: Cape Cod Septic Services, 350 Main St., W. Yarmouth, MA 02673 Engineering by: Surveying by: SCALE BRAWN JOB. NO. Engineering Works, Inc. Richard J. Mood PL5 1 "=20' P.T.M. 236-23 12 West Crossfield Road Forestdole, MA 02644 12 Settlers Path Sandwich, MA 02563 DATE CHECKED SHEET NO. (508) 477-5313 (508) 246-6260 9/25/23 P.T.M. 1 Of 2 PROPOSED SEPTIC TANK PROVIDE RISER & COVER OVER INLET & OUTLET MANHOLES AND SET WITHIN 6" OF FINISH GRADE T.O.F=103.1 t -F.G. EL.=100.0t F.G. EL.=98.1 f II 1 l f EXISTING 48" LIQUID 4 LEVEL ADD GAS I BAFFLE NOTES: 1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPES & INVERTS EXITING HOUSE, PRIOR TO INSTALLATION. 2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE ON A MECHANICALLY COMPACTED SIX INCH CRUSHED STONE BASE, AS SPECIFIED 310 CMR 15.221(2). 3) INSTALL INLET & OUTLET TEES AS REQUIRED. 4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL. DESIGN CRITERIA PROPOSED D-BOX INSTALL RISER & COVER SET TO 6" OF GRADE F.G. EL.=98.4t L= 3' S=1% (MIN.) 4"SCH40 PVC INV.=96.20-J PROPOSED INV.=96.24f D BOX (VERIFY) 3 OUTLETS H-10 NOTE: TO PREVENT BREAKOUT, THE PROPOSED FINISH GRADE SHALL NOT BE < EL. 96.3 FOR A DISTANCE OF 15' AROUND THE PERIMETER OF THE S.A.S. PROPOSED S.A.S. INSTALL RISER & COVER OVER ONE CHAMBER AND SET TO 3" OF F.G. TO SERVE AS INSPECTION PORT r F.G. EL.=98.5f MAINTAIN 2% SLOPE OVER S.A.S. 2" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE 0s $ s (On :,PROVED FB-tR FABRIC) a aaa aa-3/4- TO 1-1/2" DOUBLE 4 8' 1 3' 1 WASHED STONE INV.=96.03 EFFECTIVE WIDTH = 10. INV.=95.80 2-500 GALLON LEACHING CHAMBERS WITH STONE AROUND AND BETWEEN CHAMBERS AS SHOWN INSTALL H-20 RATED BETWEEN C L = 17'(MAX.) S-1% (MIN.) 4"SCH40 PVC 2' EFF. DEPTH TOP CONC. ELEV.= 96.9f BREAKOUT ELEV.= 96.30 INV. ELEV.= 95.80 BOTTOM ELEV.= 93.80- 4' OF NATURALLY OCCURRING PERVIOUS MATERIAL 5' ABOVE GROUNDWATER NO GROUNDWATER, EL.=88.7 - 66a as � a aBBa aa ease f9aaaa ^}� 4'(ENDS) 8.5' EFFECTIVE LENGTH = 29.0' SEPTIC SYSTEM PROFILE NUMBER OF BEDROOMS: 3 BEDROOMS SOIL TEXTURAL CLASS: CLASS I (LOADING RATE=0.74 GPD/SF) DESIGN PERCOLATION RATE: <2 MIN/IN LEACHING SYSTEM SECTION 3/4" TO 1-1/2" DOUBLE WASHED STONE 3" LAYER OF 1/8" TO 1/2" DOUBLE WASHED STONE APPROVED FILTER FABRIC; SOIL LOG DATE: SEPTEMBER 13, 2023 SOIL EVALUATOR: PETER McENTEE SE-1542 WITNESS: BARRY LEWIS HEALTH AGENT ELEV. TP - 1 DEPTH ELEV. TP - 2 DEPTH 99.7 0" 99.7 A 0" DAILY FLOW: 330 GPD FILL FILL DESIGN FLOW: 349.6 GPD 98.5 15" 98.5 A LOAMY SAND B LOAMY SAND GARBAGE GRINDER: NO -not allowed with design LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF 98.2 10YR 4/2 18„ 98 2 10YR 4/2 B C .74 GPD/SF LOAMY SAND LOAMY SAND 10YR 5/8 10YR 5/8 EXISTING SEPTIC TANK: 1000 GALLON CAPACITY 96.2 C1 42" 96.2 PROPOSED D-BOX: 1 INLET, 3 OUTLET (MIN.), H-20 RATED MED. SAND MED. SAND USE 2-500 GALLON LEACHING CHAMBERS IN SERIES WITH 2.5Y 6/4 2.5Y 6/4 STONE AROUND AND BETWEEN CHAMBERS (10.8' x 29.0') 93.0 80" 93.0 C2 SIDEWALL AREA: 2(10.8' + 29.0') X 2 = 159.2 SF BOTTOM AREA: 10.8' x 29.0' = 313.2 SF F-M SAND 2.5Y 6/6 F-M SAND 2.5Y 6/6 TOTAL AREA: .............................................................. 472.4 SF 88.7 132" 88.7 PERC RATE <2 MIN/IN. "C" HORIZON DESIGN FLOW PROVIDED: 0.74 GPD/SF(472.4 SF) = 349.6 GPD NO GROUNDWATER ENCOUNTERED 15" 18" 42" 80" 132" PROPOSED S.A.S. 2-500 GAL CHAMBERS SURROUNDED W/STONE S.A.S. LAYOUT � t-1t-1t_1t_1t_1t-1r_1t_1t-1t-1t-f ' � t-ft=ft-ft-ftTtt-ft-ft-ff=It=ff_f t_1t_tt_1t_tt-lt-lt_ft_1f_tt-1t_t 102" 4" KNOCKOUT 20" DIA. COVER 4" KNOCKOUT 0 / 4" KNOCKOUT 4" KNOCKOUT 500 GALLON CAPACITY, H-20 LOADING CHAMBERS 1 1 1 1 J 37" 58" PROPOSED SEPTIC SYSTEM UPGRADE PLAN 29 SETUCKET ROAD, YARMOUTH PORT, MA Prepared for: Cape Cod Septic Services, 350 Main St., W. Yarmouth, MA 02673 Engineering by: Surveying by: SCALE DRAWN JOB. NO. Engineering Works, Inc. Richard J. Hood PL5 N.T.S. P.T.M. 236-23 12 West Crossfield Road 12 Settlers Path DATE CHECKED SHEET NO. Forestdole, MA 02644 Sandwich, MA 02563 25 23 P.T.M. 2 Of 2 (508) 477-5313 (508) 246-6260 9 /