HomeMy WebLinkAboutEngineer PlanE�LANE
PK SET
96,64
97 37
jUpIT97,64
OLD CESSPOOL LOCATION - /
TO BE REMOVED IF ENCOUNTERED
(SEE NOTE 11)
NOTE: BUILDING LOCATION AND VERTICAL DATUM TAKEN FROM PLOT PLAN —
PROPOSED SEPTIC SYSTEM UPGRADE, PREPARED FOR MR. KEVIN HINES/
FLORENCE GEISELMAN TRUST AT 11 JUPITOR LANE, YARMOUTH, MA, BY
CARMEN E. SHAY, P.O. BOX 627, E FALMOUTH, MA, DATED NOV. 7, 2005
EXISTING SEPTIC
INV. (OUT)= 96.44
PROPOSED S.A.S.
5 HI CAP H2O INFILTRATORS
SURROUNDED W/STONE
MAP ID: 50- 84
LEGEND
— —100— —
EXISTING CONTOUR
x 100.12
EXISTING SPOT GRADE
--O.H.W.—
OVERHEAD WIRES
--UGW---
UNDERGROUND WIRES
W
EXISTING WATER SERVICE
G
EXISTING GAS SERVICE
®
TEST PIT
BENCHMARK
7 VENU3 RD I I 8 VENUS RD
( a
1 [142 LONG POND DR f o
LOCUS i 16 JUPITER IN
1 VENUS RD
138 LONG POND OR
_._ JUPiter
16 JUPITER LN
j 7 JUPITER LN
.� SJUPITERLN
OCT 3 0 2023
T. T. LOCUS MAP
NOT TO SCALE
1. ALL CHANGES TO THIS PLAN MUST BE APPROVED BY THE LOCAL
BOARD OF HEALTH AND THE DESIGN ENGINEER.
2. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS
OF THE STATE ENVIRONMENTAL CODE, TITLE V, AND ANY APPLICABLE
LOCAL RULES AND REGULATIONS, EXCEPT AS REQUESTED BELOW:
—310 CMR 15.405(1)(b): LOCAL UPGRADE APPROVAL
1) A 1' variance to the 3' maximum cover requirement, for up to
4' f SAS h It b H 20 d t d
o max. cover. . . S a e — an ven e .
Yarmouth Health De ) A 3' variance, S.A.S. to bulkhead wall, for A 17' setback.
Fartment
OVI 3. T EINSPECT INSPECTION SEWAGE DISPOSAL
APPROVAL BY TSHALL
HE NOT
BOARD OFHEALTHAND THE
Y
�k) ESIGN ENGINEER.
Nam NY CONDITIONS ENCOUNTERED DURING CONSTRUCTION DIFFERING
Date ROM THOSE SHOWN HEREON SHALL BE REPORTED TO THE DESIGN
NGINEER BEFORE CONSTRUCTION CONTINUES.
5. ALL ELEVATIONS BASED ON ASSUMED DATUM.
TANK 6. THE DESIGN ENGINEER IS NOT RESPONSIBLE FOR THE FAILURE OF
THE CONTRACTOR OR OWNER TO NOTIFY THE LOCAL BOARD OF
HEALTH FOR PROPER INSPECTIONS DURING CONSTRUCTION.
EXISTING S.A.S. 7. WATER SUPPLY PROVIDED BY TOWN WATER SERVICE.
(PER TITLE 5 INSPECTION REPORT) 8. THERE ARE NO WELLS WITHIN 100' OF THE PROPOSED S.A.S.
TO BE REMOVED WITHPROPOSED
9. ALL AREAS CLEARED FOR CONSTRUCTION SHALL BE RESTORED AS
(S OF THE PROPOSED S.A.S. AGREED UPON BY OWNER AND CONTRACTOR OR AS OTHERWISE
(SEE NOTE 11) DIRECTED BY THE APPROVING AUTHORITIES.
STRIPOUT 10. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
SEE NOTE 11 THE LOCATION OF ALL UNDERGROUND UTILITIES, PRIOR TO BEGINNING
M4ssgc CONSTRUCTION.
y� yG 11. WHERE REQUIRED, CONTRACTOR SHALL REMOVE ALL UNSUITABLE SOILS
o PETER T. �, IN THE AREA BENEATH AND FOR 5' ON ALL SIDES OF THE S.A.S. AND
McENTEE REPLACE WITH CLEAN SAND AS SPECIFIED IN 310 CMR 255(3).
CIVIL "' 12. AREAS REQUIRING STRIPOUT OF UNSUITABLE MATERIALS SHALL BE
No. 35109 INSPECTED BY HEALTH DEPARTMENT PRIOR TO BACKFILL.
£v silt' 13. THIS PLAN IS TO BE USED FOR SEPTIC SYSTEM PURPOSES ONLY AND
_ i (' -r.� td3 IS NOT TO BE CONSIDERED A PROPERTY LINE SURVEY.
(4i2cl z>
PLAN REVISION 10/21 /23
SHOW CORRECT AS -BUILT INFORMATION
CURRENT OWNER OF RECORD
SHERNETT ALTHEA WILLIAMS MCDONALD
& JEFTHER J MCDONALD
11 JUPITER LANE
SOUTH YARMOUTH, MA 02664
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
11 JUPITER LANE. SOUTH YARMOUTH. MA
Prepared for: Cape Cod Septic Services, 350
Main St, W.
Yarmouth,
MA 02673
Engineering by:
SCALE
DRAWN
JOB. NO.
Engineering Works, Inc.
1"=20'
P.T.M.
235-23
12 West Crossfield Road, Forestdale, MA 02644
DATE
CHECKED
SHEET NO.
(508) 477-5313
10/11/23
P.T.M.
1 Of 2
COVERSSEPTIC TANK
INSTALL RISERS & OVER INLET
E
OUTLET
• OF FINISH
T.O.F.=100.0±
..
EXISTING
PROPOSED D-BOX
INSTALL RISER & WATERTIGHT
COVER SET TO 6" OF GRADE
L = 12'
S=1% (MIN.)
4"SCH40 PVC
F.G. EL.=99.6t
L = 4'
® S=1% (MIN.)
4"SCH40 PVC
tj t4 Al 61 I 11" LFF.
DEPTH
ADD INV.=96.00
EXISTING GAS BAFFLE INV.=96.17 PROPOSED
INV.=95.92 3.5'
INV.=96.44 D-BOX
EXISTING PLASTIC 1500 GALLON SEPTIC TANK (VERIFY)
NOTES:
1) CONTRACTOR SHALL VERIFY ALL EXISTING PIPE
INVERTS, PRIOR TO INSTALLATION.
2) D-BOX SHALL BE SET LEVEL AND TRUE TO GRADE
ON A MECHANICALLY COMPACTED STABLE BASE OR
SIX INCH AGGREGATE BASE, AS SPECIFIED IN 310
CMR 15.221(2).
3) INSTALL INLET & OUTLET TEES AS REQUIRED.
4) A GAS BAFFLE SHALL BE INSTALLED ON OUTLET TEE
AS MANUFACTURED BY TUF-TITE, ZABEL OR EQUAL.
DESIGN CRITERIA
NOTE: TO PREVENT BREAKOUT, THE PROPOSED
FINISH GRADE SHALL NOT BE < EL.=96.3
FOR A DISTANCE OF 15' AROUND THE
PERIMETER OF THE S.A.S.
PROPOSED S.A.S.
INSTALL INSPECTION PORT (MIN.) INSTALL
WITH ACCESS SET TO 3" OF GRADE VENT
F.G. EL.=99.6t Z�
INSPECTION
PORT
5 UNITS AT 6.25'/UNIT = 31.3' 13.5'
EFFECTIVE LENGTH = 37.3'
USE 1 ROW OF 5-HI CAPACITY H-20 INFILTRATOR CHAMBERS IN
SERIES SURROUNDED W/STONE TO FOR A 10.0' x 37.3' S.A.S.
SOIL ABSORPTION SYSTEM (PROFILE)
KTS
BREAKOUT ELEV.=96.33
BOTTOM ELEV.=95.00
4' OF NATURALLY
OCCURRING PERVIOUS SOIL'
5' MIN. ABOVE MAX. G.W.
2" LAYER OF
1/8"-1/2" DOUBLE
WASHED STONE
3/4"-1 1/2" DOUBLE
WASHED STONE
IMPERVIOUS LAYER AT EL.=90.2 -_�-
BOTTOM OF TEST HOLE, EL.=87.5
SOIL ABSORPTION SYSTEM (SECTION)
SEPTIC SYSTEM PROFILE KTS
NUMBER OF BEDROOMS: 3 BEDROOMS
SOIL TEXTURAL CLASS: CLASS I
DESIGN PERCOLATION RATE: <5 MIN./INCH
DAILY FLOW: 330 GPD
DESIGN FLOW: 330 GPD
GARBAGE GRINDER: NO - NOT PERMITTED FOR GARBAGE GRINDER
EXISTING SEPTIC TANK: 1500 GALLON CAPACITY (PLASTIC TANK)
LEACHING AREA REQUIRED: (330 GPD) = 445.9 SF
.74 GPD/SF
DISTRIBUTION BOX: 1 INLET, 4 OUTLETS (H-20)
USE 1 ROW OF 5 HIGH CAPACITY H-20 INFILTRATOR UNITS W/STONE
AS SHOWN, FOR AN S.A.S. HAVING THE DIMENSIONS: 37.3' x 10.0'
SIDEWALL AREA: 2(10.0'+37.3') x 0.92' = 87.0 SF
BOTTOM AREA: 37.3' x 10.0' = 373.0 SF
TOTAL AREA: 460.0 SF
DESIGN FLOW PROVIDED: 0.74(460.0 SF) = 340.4 GPD
SOIL LOG
DATE: OCTOBER 31, 2005
SOIL EVALUATOR: CARMEN SHAY IRS CSE
HAELTH AGENT: AMY VON HONE IRS HEALTH AGENT
ELEV. TP DEPTH
99.0 A LOAMY SAND 0
10YR 3/2
98.2 1 p"
B LOAMY SAND
10YR 5/6
96.3 32"
Cl PERC
M-F SAND [136"/54"
2.5Y 7/3
90.2
C2 SILT LOAM
2.5Y 6/2
89.2
C3
MED. SAND
2.5Y 7/4
106"
118"
87.5 138"
NO GROUNDWATER ENCOUNTERED
PERC RATE 2 MIN/IN. ("Cl- HORIZON
GARAGE
icni.-)iiivu ,
HOUSE& 11)
T.O.F.=100.0f
4o
Co
35. 7'
N ' o
�--37.3'--_ _---'
PROPOSED S.A.S.
5 HI CAP H2O INFILTRATORS
SURROUNDED W/STONE
S.A.S. LAYOUT
000000
000000
000.0.0
0000000
00000000II
28"—^
II00000000II
h- — 28"--i
Closed End Plate Open End Plate
HIGH CAPACITY H-20 INFILTRATOR CHAMBER
INFILTRATOR CHAMBERS
N.T.S.
PROPOSED SEPTIC SYSTEM UPGRADE PLAN
11 JUPITER LANE, SOUTH YARMOUTH, MA
Prepared for: Cape Cod Septic Services, 350 Main St, W. Yarmouth, MA 02673
Engineering by: SCALE DRAWN JOB. NO.
Engineering Works, Inc. N.T.S. P.T.M. 235-23
12 West Crossfield Road, Forestdole, MA 02644 DATE CHECKED SHEET NO.
(508) 477-5313 10/11/23 P.T.M. 2 Of 2