Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot , // 0 Zone of Contribution: In__-- Out Acreage Street: j Commercial: Residential: i----' Village: Floor Plan: , f } /� #Bedrooms: Owner: S:x= n' // /r, ! ,`' �`t,i Installer: ( /q, L L7 `k,o/'i-- Address: it j.,,1 - I„ Phone: . / ) .;y J,.,� 5 z s 7� z Phone: ? -,,,. Builder: Engineer: i i 1 Address: ' � � ��= ��1� Phone: Phone: _ i 7 }: 5-3, 1. Required#of copies received N'A YES NO 2. Date of soils exam and percolation test not older than 2 years ' - 3. 4-5 ft of naturally occurring pervious material,above water table -- L./4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: L --_-_ 5. Water line 10 ft from septic components Var.: I - 6. Benchmark indicated and shown-NGVD if near wetlands I /. 7. Septic tank minimum 10 ft from foundation, deck Var.: 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I -- 9. Leaching minimum 100 ft from wetlands Var.: I 10. Leaching minimum 150 ft from drinking rvell/25 ft irrigation well Var.: _i" 11. Tank/leaching minimum 10 ft from property line Var.: ; 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: ✓. 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: �� I_____ 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", '''A"preferred (i 18. System meets breakout requirements PVC liner: Wall: ,'',7 19. Specified tee sizes are proper, gas baffle on outlet tee 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal `/ 22. System adequately sized for its intended use `' 23.Minimum 6"stone or compacted below tank and dbox ✓ 24. Manhole covers within 6"of grade, pump chamber cover to grade I 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Separate meter for duplexes rj 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 1,/ 28. Septic tank/pump chamber to be factory waterproofed 1. 29. Vent provided if leaching below 3 feet,under driveway/parking 30.Buoyancy calculations for tank/pump chamber • I V 31. Engineer to inspect and certify soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,, 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature`---- 35.Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: 37. Check area lots for groundwater/Label groundwater in Assessor's Mapgpd Plan reviewed by: j >, (rcool L