HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot , // 0 Zone of Contribution: In__-- Out Acreage
Street: j Commercial: Residential: i----'
Village: Floor Plan: ,
f } /� #Bedrooms:
Owner: S:x= n' // /r, ! ,`' �`t,i Installer: ( /q, L L7 `k,o/'i--
Address: it j.,,1 - I„ Phone:
. / ) .;y J,.,� 5 z s 7� z Phone: ? -,,,.
Builder: Engineer: i
i 1
Address: ' � � ��= ��1�
Phone: Phone: _ i 7 }: 5-3,
1. Required#of copies received N'A YES NO
2. Date of soils exam and percolation test not older than 2 years ' -
3. 4-5 ft of naturally occurring pervious material,above water table -- L./4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: L --_-_
5. Water line 10 ft from septic components Var.: I -
6. Benchmark indicated and shown-NGVD if near wetlands I /.
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I --
9. Leaching minimum 100 ft from wetlands
Var.: I
10. Leaching minimum 150 ft from drinking rvell/25 ft irrigation well Var.: _i"
11. Tank/leaching minimum 10 ft from property line Var.: ;
12. System meets all other setback requirements Var.:
13. Uses adjustment for maximum high groundwater Var.: ✓.
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: �� I_____
15. System not in top or subsoil (A,B horizons)or 5' removal
16. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '''A"preferred (i
18. System meets breakout requirements PVC liner: Wall: ,'',7
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel
21.No garbage disposal `/
22. System adequately sized for its intended use `'
23.Minimum 6"stone or compacted below tank and dbox ✓
24. Manhole covers within 6"of grade, pump chamber cover to grade I
25. Inspection port on plastic chambers/leach field
26. Electrical permit for pump chamber/Separate meter for duplexes rj
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 1,/
28. Septic tank/pump chamber to be factory waterproofed 1.
29. Vent provided if leaching below 3 feet,under driveway/parking
30.Buoyancy calculations for tank/pump chamber • I V
31. Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,,
33.H-20 loading is subject to vehicular traffic,groundwater
34.Title V Application and permit fee, installer signature`----
35.Foundation footing min. 2 feet above adjusted ground water for new house
36. Deed Restriction required max. #bedrooms: max. flow:
37. Check area lots for groundwater/Label groundwater in Assessor's Mapgpd
Plan reviewed by: j >, (rcool