Loading...
HomeMy WebLinkAboutEngineer Plan34' ..................... LEACH AREA DETAIL (LOW PROFILE FLOWDIFFUSORS) LN LOCATION MAP LOT 111 (10,258 SF) ASSESSORS MAP:34 PARCEL:29 LAND COURT CASE 14113 40 MIL POLY LINER 124' x T DEEP TOP OF LINER = 103.3 BOTTOM ELEVATION =100.3 LOW AREA TO RETAIN STORM WATER RUN-OFF 102 i 101 i KEY: EXISTING CONTOUR: - - - - PROPOSED CONTOUR: ------------- EXISTING SPOT ELEVATION: 25.5 PROPOSED SPOT ELEVATION: 5.5 TEST HOLE: _+ UTILITY POLE: -� FENCE LINE: - HYDRANT: RETAINING WALL: M21-36 SEPTIC SYSTEM DESIGN FLOW ESTIMATE: 3 BEDROOMS AT 110 GAL / DAY = 330 GAL / DAY SEPTIC TANK: 330 GAL / DAY x 2 DAYS = 660 GAL USE 1500 GALLON SEPTIC TANK lo LEACHING AREA: USE 4 LOW PROFILE FLOWDIFFUSORS WITH 4' OF STONE AROUND SIDES AND VAT ENDS 34' x 12' x 6" EFF. DEPTH) SIDE AREA: (34' + 12') x 2 x 6/12 = 46 SF (0.74) = 34 GAL/DAY BOTTOM AREA: 34' x 12' = 408 SF (0.74) = 302 GAL/DAY CAPACITY = 336 GAL/DAY "101 101 - _ _ 101.3 �63BA59�' Vie.'` �3s. a - ees NIt Ire ` -102 b)o ro .;0 rnp �o 21' P�J(, �QO QP� ,� CK W OE 10, a 13' CD 103 0 \ c(o m 103--- ' 104 - - \ 104 sNEo / j 19.81' I BENCHMARK AT SURVEYOR'S NAIL ELEVATION =101.83 ova -0_ 00 SEPTIC SYSTEM SECTION A QUICPRESSURE DISCONNECT IS O BE IT PROVIDGH E FOR ER OR TANK. FUTURE ACCESS TO PUMP. 2" PEASTONE OR FILTER FABRIC 103.71 PUMP CHAMBER COVER TO BE AT GRADE. 314" -1 1/2" DOUBLE ALL OTHER COVERS TO BE WITHIN 6" OF GRADE. WASHED STONE TOP OF INSPECTION PORT TO BE WITHIN W OF GRADE INSPECTION PORT FOUNDATION ELEV: 103.3 TEE AT " 104 3' MAX. 1/4" per ft 101.92 1/8" per ft INLET �� COVER ELEV. (1' MIN) A 100.5 103.3 100.75 ELEV. 00.46 103.16 y�0 ELEV. ELEV. 102.8 102.3 ELEV. ELEV. ELEV. " a D-BOX H 1 � ELEV. 2 1500 GAL 95.96 1000 GAL (6" OF STONE UNDER) ELEV. SEPTIC TANK GAS ELEV. PUMP CHAMBER 34' x 12' -3 100.3 Z STING PPE BAFFLE 4 LOW PROFILE FLOWDIFFUSORS ((6" OF STONE UNDER OR & WITH MYERS SRM-4 PUMP. PUMP ALARM 1/4" DRAIN HOLE ELEV.=101.21 MECHANICALLY COMPACTED) ZABEL PACKAGE TO BE INSTALLED IN DWELLING WITH 4' OF STONE AROUND SIDES 5' TEE SIZES: FILTER POWERED BY A CIRCUIT SEPARATE FROM CHECK AND VAT ENDS INLET: 6" UP,13" DOWN THE PUMP POWER. (DISTANCE BETWEEN VALVE (34' x 12' x 6" EFF. DEPTH) OUTLET: 6" UP, 14" DOWN ON/OFF SWITCH TO E 41 (DISTANCE BETWEEN ON SWITCH ADJUSTED GROUND WATER ELEVATION = 97.3� AND ALARM TO BE 12") TH-1 101.7 TEST HOLE LOGS O/AHORIZON ELEV. LAUNDRY DINING ENGINEER: THOMAS McLELLAN, P.E. OAMg• 10YR Y SAND 101.0 FAMILY AREA = WITNESS: PHIL RENAUD ROOM � B HORIZON m BED O DATE: 9-22-21 LOAMY SAND ROOM a PERCOLATION RATE: < 2 MIN/IN24" 10YR 5/8 99.7 BATH KITCHEN C HORIZON MEDIUM SAND 2.5Y 7/4 PE�RC AT 42" s USGS GROUND WATER ADJUSTMENT: DECK WELL: MIW-29, ZONE: A, ADJUSTMENT: 2.1' 78" OBSERVED 95.2 ADJUSTED GROUND WATER ELEV.= 97.3 120-1 GROUNDWATER 1 91.7 EXISTING FLOOR PLAN REMOVE T OF EXISTING DWELLING 18' 2.5' _ NEW LAUNDR -BED �Y FAMILY AADIN -ROOM z ! ROOM , BED m D QROOM n aBATH KITCHEN � NEW BED NEW ROOM DECK DK. 18, EXISTING AND PROPOSED FLOOR PLAN I BUOYANCY CALCULATION :1500 GALLON SEPTIC TANK 10.5' x 5.6T x (97.3 - 96.25) x 62.4 LB/CF = 3,901 LB WEIGHT OF TANK = 11,480 LB BUOYANCY CALCULATION: 1000 GALLON PUMP CHAMBER 8.5' x 4.83' x (97.3 - 95.96) x 62.4 LB/CF = 4,978 LB WEIGHT OF TANK = 8,240 LB NOTE: DESIGN ENGINEER TO INSPECT AND CERTIFY CONSTRUCTION OF PROPOSED SEPTIC SYSTEM. CERTIFICATION TO INCLUDE INSPECTION OF FINAL GRADING SO AS TO PREVENT STORM WATER RUN-OFF TO FLOW TOWARDS ABUTTING PROPERTIES. EXISTING GRADE AT LOT LINE =101.3 PROPOSED GRADES NOTES: 1. VERTICAL DATUM: ASSUMED 2. MUNICAPAL WATER IS AVAILABLE. 3. SCHEDULE 40 - 4" PVC PIPE TO BE USED THROUGHOUT SEPTIC SYSTEM. 4. ALL PRECAST UNITS SUBJECT TO TRAFFIC LOADS TO CONFORM WITH AASHTO H-20 SPECIFICATIONS. 5. PIPE PITCH = 1/4" PER FOOT (UNLESS NOTED OTHERWISE). 6. FIRST 2' OF PIPE OUT OF D-BOX TO BE SET LEVEL. 7. THE SEPTIC SYSTEM HAS NOT BEEN DESIGNED TO ACCOMODATE THE USE OF A GARBAGE DISPOSAL. 8. ALL CONSTRUCTION DETAILS ARE TO BE IN CONFORMANCE WITH THE STATE OF MASS. ENVIRONMENTAL CODE (TITLE FIVE) AND LOCAL HEALTH REGULATIONS. 9. CONTRACTOR TO VERIFY LOCATIONS OF ALL UTILITIES PRIOR TO CONSTRUCTION. 10. GROUND COVER OVER ALL SEPTIC SYSTEM COMPONENTS NOT TO EXCEED T WITHOUT VARIANCE. 11. FIELD SURVEY PROVIDED BY TERRY A. WARNER, P.L.S., HARWICH, MA. 12. THIS PLAN REQUIRES THE REVIEW AND APPROVAL OF ONE OR MORE TOWN DEPARTMENTS AND IS SUBJECT TO CHANGE UNTIL SUCH TIME. THIS PLAN HAS BEEN PREPARED FOR THE SOLE PURPOSE OF CONSTRUCTION OF A NEW SEPTIC SYSTEM AND DOES NOT NECESSARILY REPRESENT A FULL DETAILED PROPERTY SURVEY. 13. EXISTING CESS POOLS ARE TO BE PUMPED AND REMOVED. 14. D-BOX TO BE WATER TESTED TO ENSURE LEVELNESS AND EQUAL FLOW. 15. AN ELECTRIC PERMIT FOR THE PUMP PACKAGE IS TO BE OBTAINED PRIOR TO CONSTRUCTION. 16. SEPTIC TANK AND PUMP CHAMBER ARE TO BE WATER PROOFED BY MANUFACTURER WITH IPANEX CONCRETE ADDITIVE OR CONSEAL 55. A 6" EZ WRAP IS ALSO REQUIRED FOR BOTH TANKS. 17. ALL UNSUITABLE SOIL, (A & B HORIZON, APPROX. 2' DEEP) WITHIN 5' OF PROPOSED LEACH AREA IS TO BE REMOVED AND REPLACED WITH CLEAN MEDIUM SAND. -) SITE PLAN THO':.43 J. tiN R"aLELLAN C.? CIVIL y No. 30471 T�O DRAINAGE I,(� SWALE DETAIL THOMAS J. McLELLAN, P.E. / LOCATION: 9 MMLARD RD., S. YARMOUTH, MA PREPARED FOR: DON & KATHY MOMSON DATE: 10-21-21 SCALE: V = 20' REVISED: 11-11-21(DRAINAGE SWALE DETAIL) BASS RIVER ENGINEERING P.O. BOX 1163, EAST DENNIS, MA 02641 508-364-9048 �. V' 413) ,�TZ-� t-E-6►.--� l�ao sa2l Data L. anw­ DEC 2 0 2021 HEALTH DIE PT