Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot i 2/ji; Zone of Contribution: In_ Out_ Acreage Commercial: Residential: <�' Street: �:) i - ____ Village: Floor Plan: ✓ #Bedrooms: 3 Owner: �),' t,�t, r` .'�4 /��k j �. Installer 0,2 K_.y i, `v .v, ^, farm;/I ('/, Address: 13 i).?.i.e;fvn ,, , ,A.)(4•-‘11'.1</'.: r Phone: 7- )z/ - 5 l j - c h�a Phone: SZ% s 3 j ,.4 v Builder: Address: Engineer: 1,;1c;( 5. i, e-r,,.: , U t, Phone: Phone: s .- _j3 _,c, i v ) 1. Required#of copies received N/A YES I NO 2. Date of soils exam and percolation test not older than 2 years - " 3. 4-5 ft of naturally occurring pervious material; above w at table },�i^ Lr ''` t1 }� 1) _ i....... 4. Foundation 2 ft above highpoint of road g H.P.: Fnd: Var.: ---- 5. Water line 10 ft from septic components Var.: - 6. Benchmark indicated and shown-NGVD if near wetlands V� 7. Septic tank minimum 10 ft from foundation, deck Var.: v 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: 9. Leaching minimum 100 ft from wetlands Var.: I '' 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: v 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", %"preferred 18. System meets breakout requirements PVC liner: Wall: 19. Specified tee sizes are proper, gas baffle on outlet tee v 20. Sewage is under 10,000 gpd for parcel ` 21.No garbage disposal °` 22. System adequately sized for its intended use 23.Minimum 6"stone or compacted below tank and dbox I 24. Manhole covers within 6"of grade, pump chamber cover to grade v 25. Inspection port on plastic chambers/leach field v 26. Electrical permit for pump chamber/Separate meter for duplexes 27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed ✓ 29. Vent provided if leaching below 3 feet,under driveway/parking v 30. Buoyancy calculations for lank/pump chamber L' 31. Engineer to inspect and certify soils: wall: commercial: ✓vs 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature `✓ 35. Foundation footing min. 2 feet above adjusted ground water for new house y „ 36.Deed Restriction required max. #bedrooms: max. flow: gpd I 37. Check area lots for groundwater/Label groundwater in Assessor's Map I ,.i Plan reviewed by: - - ao;o;