Loading...
HomeMy WebLinkAboutLVL SPECS 103122 ®BoiseCascadeE DUCTS Triple 1-3/4" x 9-1/2" VERSA-LAM® 2.0 3100 SP PASSED FB01 (Flush Beam) BC CALC®Member Report Dry 11 span I No cant. Build 8435 October 31, 2022 16:22:46 Job name: File name: Address: 22 Old Saga Drive supporting Description: City, State, Zip: Yarmouth , MA p 2nd fl bedrooms Specifier: Customer: Designer: William Campbell Code reports: ESR-1040 Company: l l l 1 1 1 1 1 1 1 1 1 1 1 1 111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 0l 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 B1 15-00-00 x Total Horizontal Product Length=15-00-00 B2 Reaction Summary (Down / Uplift) (Ibs) Bearing Live Dead B1, 3-1/2" Snow Wind Roof Live 2700/0 1008/0 B2, 3-1/2" 2700/0 1008/0 Load Summary Live Dead Snow Wind Roof Tributary Live Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125% 0 Self-Weight Unf. Lin. (lb/ft) L 00-00-00 15-00-00 Top 14 1 Bedrooms Unf.Area (lb/ft2) L 00-00-00 15-00-00 Top 30 10 12-00-00 12-00-00 Controls Summary Value %Allowable Duration Case Location Pos. Moment 13069 ft-lbs 62.4% 100% 1 07-06-00 End Shear 3173 lbs 33.5% 100% 1 01-01-00 Total Load Deflection L/263 (0.663") 91.2% n\a Live Load Deflection L/361 (0.483") 99.6% 1 07-06-00 ° n1a 2 07-06-00 Max Defl. 0.663" 66.3% n\a Span/Depth 18.4 1 07-06 00 LxW %Allow %Allow Bearing Supports Dim. (LxW) Value Support Member Material B1 Wall/Plate 3-1/2"x 5-1/4" 3708 lbs n\a B2 Wall/Plate 3-1/2"x 5-1/4" 3708 lbs n\a 26.9% Unspecified 26.9% Unspecified Notes Design meets Code minimum (L/240)Total load deflection criteria. Design meets Code minimum (L/360) Live load deflection criteria. Design meets arbitrary(1") Maximum Total load deflection criteria. Design based on Dry Service Condition. BC CALL®analysis is based on IBC 2015. Calculations assume member is fully braced. Connection Dia ram: Full Len th of Member b d a e Page 1 of 2 ®BoiseCascadeENGREED OPRODUCTS Triple 1-3/4" x 9-1/2" VERSA-LAM®2.0 3100 SP PASSED FB01 (Flush Beam) BC CALC®Member Report Build 8435 Dry I 1 span I No cant. October 31, 2022 16:22:46 Job name: File name: Address: 22 Old Saga Drive Description: supporting City, State,Zip: Yarmouth , MA 2nd fl bedrooms Specifier: fier: Designer: William Campbell Code reports: ESR-1040 Company: Connection Diagram: Full Length of Member a minimum= 1-1/2" c=3-1/4" b minimum=4" d= 12" e minimum= 1" Calculated Side Load=0.0 lb/ft Install screws from both sides,staggering screws by half of the spacing to avoid splitting. Connectors are: SDS 1/4 x 4-1/2 Disclosure Use of the Boise Cascade Software is subject to the terms of the End User License Agreement(EULA). Completeness and accuracy of input must be reviewed and verified by a qualified engineer or other appropriate expert to assure its adequacy,prior to anyone relying on such output as evidence of suitability for a particular application.The output here is based on building code-accepted design properties and analysis methods. Installation of Boise Cascade engineered wood products must be in accordance with current Installation Guide and applicable building codes.To obtain Installation Guide or ask questions,please call(800)232-0788 before installation. BC CALC®,BC FRAMER®,AJSTM, ALLJOIST® BC RIM BOARDTM,BCI®, BOISE GLULAMTM BC FloorValue®, Page 2 of 2 VERSA-LAW:),VERSA-RIM PLUS®,