HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH 7
(„( 2
SEWAGE PLAN REVIEW CHECKLIS'e"
Location: A.M. 1 7 Lot 7O 7 Zone of Contribution: In ut_ Acreage G� 7k)
Commercial: Residential:
Street: 60 0 r s , 4,fr- 7(,
Village: "V'�• 'AV- Floor Plan: ✓ #Bedroom : 2
Owner: Jg / / t9 Installer: 7
Address: b Phone:
��
Phone: ��77�i - 0) ae)
Builder: Vil/(A-12 Engineer:
Address: Phone: -36 2_ - J ?
Phone: 60l4- fz. 1N'-cz' - f / 1
_ Coo L/a. , 55 4_,
N/A YES NOS
1.Required#of copies received
2. Date of soils exam and percolation test not older than 2 years
3. 4-5 ft of naturally occurring pervious material,above water table ` -
4.Foundation 2 ft above high point of road H.P.: .Fnd: Var.:
5. Water line 10 ft from septic compopents "', Var.: �.,-/
6.Benchmark indicated and shown-CNGVD if near wetlands L.-./
7. Septic tank minimum 10 ft from foundation, deck Var.: i/
8.Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9.Leaching minimum 100 ft from wetlands Var.: L-----
10.Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: .`-----
11.Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.:
13.Uses adjustment for maximum high groundwater Var.: t.
14.Leaching set 4-5 ft above adj.water or botto test hole `Var.: /-1
15. System not in top or subsoil(A,B horizons) 5'removal
16.Proposed contours are suitable
17. System meets slope requirements-min. 1/8", ' "preferred
18. System meets breakout requirements PVC liner: Wall: (... --)-
19. Specified tee sizes are proper, gas baffle on outlet tee
• 20. Sewage is under 10,000 gpd for parcel i/--
21.No garbage disposal
22.System adequately sized for its intended use
23.Minimum 6"stone or compacted below tank and dbox t�
24.Manhole covers within 6"of grade,pump chamber cover to grade (... '
25.Inspection port on plastic chambers/leach field t� .
26.Electrical permit for pump chamber/Separate meter for duplexes ,../
27.Pump system-2" line,weep hole,check valve,tee in dbox,pump size k./
28. Septic tank/pump chamber to be factory waterproofed
29.Vent provided if leaching below 3 feet,under driveway/parking
30. Buoyancy calculations for tank/pump chamber ``
31. Engineer to inspect and certify soils: wall`/) (�commercial:
32.Engineer/Registered Sanitarian and Land Surveyor stamps/signature ,...-"
33. H-20 loading is subject to vehicular traffic, groundwater
34.Title V Application and permit fee, installer signature �-
35.Foundation footing min. 2 feet above adjusted ground water for new house C-y7"--)
36. Deed Restriction required max. #bedrooms: \ max. flow: ,t 0 gpdi.7
37.Check area lots for groundwater/Label groundwater in Assessor's Map
Plan reviewed by: ('- --r6t---
6/03/03