HomeMy WebLinkAboutReview Checklist TOWN OF YARMOUTH
SEWAGE PLAN REVIEW CHECKLIST
Location: A.M. Lot Cf 6,?? Zone of Contribution: In Out_ Acreage
Commercial: r - Residential:
Street:4 01 i L!�0 5- '-i1 b A-,e ----
Village:
S. Y Floor Plan: 1/.J #Bedrooms:
Owner: 1 L e' piney LLG Installer:Teo 1/0.7I/S r _
Address: G 9 c- 6vwr7,e IN441--/b,. i4 yw iLikc'i"Is Phone: 'bps- 9$c/ /Phone: 4/:t- 9yj- ,s,Doc
Builder: Engineer: P�h
Coe
Address:
Phone: Phone: SD is-- 3 - /Sys
1. Required#of copies received NIA YES NO
2. Date of soils exam and percolation test not older than 2 years -
3. 4-5 ft of naturally occurring pervious material, above water table - -- -
4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: ---
5. Water line 10 ft from septic components Var.: . I -
6. Benchmark indicated and shown-NGVD if near wetlands
7. Septic tank minimum 10 ft from foundation, deck Var.:
8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.:
9. Leaching minimum 100 ft from wetlands Var.:
10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.:
11. Tank/leaching minimum 10 ft from property line Var.:
12. System meets all other setback requirements Var.: ✓
13. Uses adjustment for maximum high groundwater Var.:
L, i
14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.:
15. System not in top or subsoil(A,B horizons)or 5' removal V
I6. Proposed contours are suitable
17. System meets slope requirements-min. 1/8", '''A"preferred
18. System meets breakout requirements PVC liner: Wall:
19. Specified tee sizes are proper, gas baffle on outlet tee
20. Sewage is under 10,000 gpd for parcel ✓
21.No garbage disposal '�
22. System adequately sized for its intended use `.,
23.Minimum 6"stone or compacted below tank and dbox
24. Manhole covers within 6"of grade, pump chamber cover to grade _
25. Inspection port on plastic chambers/leach field l/
26. Electrical permit for pump chamber/Separate meter for duplexes ./` ✓
27.Pump system-2"line,weep hole,check valve, tee in dbox, pump size
28. Septic tank/pump chamber to be factorywaterproofed '/
29. Vent provided if leaching below 3 feet,under driveway/parking `�
30.Buoyancy calculations for tank/pump chamber
31.Engineer to inspect and certify soils: wall: commercial:
32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature ✓
33.H-20 loading is subject to vehicular traffic,groundwater ' %7
34.Title V Application and permit fee,installer signature t//
35. Foundation footing min. 2 feet above adjusted ground water for new house
36.Deed Restriction required max. #bedrooms: max. flow: gpd ✓
37. Check area lots for groundwater/Label groundwater in Ass ' 's Map I I
Plan reviewed by: //.. / 3 - -
-
co,o;