HomeMy WebLinkAbout5067 99 Buck Island Rd Applicationog-V
z �
� c
ZONING BOARD OF APPEALS HEARING APPLICATION (Appeal Informal '
Appeal#: Hearing Date: �Y/A7.3 Fee
Applicant is the (check one): Owner x Tenant Prospective Buyer Other Interested Party
-'� f '�i
REC
Applicant (full names, including d/bla): Y Colby, DPW ''�7�' ""-`
Town of Yarmouth (Jeffrey
Address: 74 Town Brook Road, MA 02673
Phone: 508-398-2231
Email: jcolby@yarmouth.ma.us
This application relates to the property located at:
99 Buck Island Road, Yarmouth, MA 02
Shown on the Assessor's Map as:
Map # 48
Parcel #: 1
• Zoning District: MU
Property located on un-constructed (paper) street? Provide nearest cross street name or other identifying location:
NA
Project Summary (this information is used for the Legal Notice in the newspaper): Applicant seeks permission to
(e.g., add a 10' by 15' deck to the front of our house). construction of new water Resource Recovery Facility (WRRF)
behind water Dept. Building. WRRF includes Headworks Bldg, Process Bldg./Gallery W Disinfection Bldg,
Solids Handling Bldg., and Vehicle Storage Bldg (addition to Water Dept. Building).
RELIEF REQUESTED: The applicant seeks the following relief from the Zoning Board of Appeals:
Requesting relief of maximum building height for one proposed structure. Building height of Headworks
Building is 401-8" to top of parapet (36'-411 to top of roof).
_REVERSE BUILDING INSPECTOR OR ZONING ADMINISTRATOR DECISION (include a copy of this
decision with this application). What is the decision date?:
The reason for reversal and the ruling you request the Board to make:
_SPECIAL PERMIT under Yarmouth Zoning By-law Section:
and/or for a use authorized upon Special Permit in the "Use Regulation Schedule" §202.5:
x VARIANCE from the Yarmouth Zoning By-law. Specify all sections of the by-law from which relief is requested,
and, as to each section, specify the relief sought:
Section & Relief
Section & Relief sought:
Section & Relief sought:
203.4 - Max Buidling Height 351, Proposed 401-811 to top of parapet
ADDITIONAL INFORMATION (which you feel should be included in your application):
This height of the Headworks Building is driven by hydraulic gradeline considerations that
require the "start" of the plant be at a certain elevation that will permit gravity flow to
downstream portions. / 0-� L-5 f_ W�'ilf�s,?r 624� _ !9,�-O-�OCZJra Xr7_44ZACI
$ 0
ZONING BOARD OF APPEALS HEARING APPLICATION (Property Information)
Name & Address of Current Property Owner (if other than applicant) as listed on the Deed:
Title Deed Reference (provide a copy of most recent Deed):
• Book & Page #: 220721 / 7061
• or Certificate #:
• Land Court Lot #:
• Plan #:
Use Classification:
• Existing: F8 Public Utili
§202.5 #
• Proposed: F8 Public Utilit
§202.5 #
Is the property vacant?: Yes x No
If yes, how long has property been vacant?
Lot Information
• Size/Area: 151.56 AC
• Plan Book & Page: 220721 / 7061
• Lot #: 4 8 / 1
Is this property within the Aquifer Protection Overlay District (APD)? Yes No x
Have you completed a formal commercial site plan review (if needed)? Yes x No
Which other Boards and/or Town Departments are/have/will review this project? What is the status of review?
DPW (Engineering), Building, Community Planning and Development,
Conservation, Fire, and Health
Is this a repetitive petition (re -application)? Yes— No x
If required, do you have Planning Board Approval? Yes x No
Has this property been the subject of prior relief from the Zoning Board of Appeals? Yes No x
If yes, provide the date(s), Appeal number(s), decision(s), and other pertinent information with this application.
Building Commissioner Comments:
Applicant / Attorney 1 Agent Signature:
Property Owner Signature:
Address:
Phone
Building Commissioner Signature:
PC
Date: �� 3