Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YAR1 1OUTH • SEWAGE PLAN REVIEW CHECKLIST Location: A.M. - Loti'tj� 0(;'t Zone of Contribution: In Out_ Acreage 40 Commercial: Residential: v Street: .j e) 1 . -f,,, ( r� -- Village: Floor Plan: #Bedrooms: j Owner. o ' i r / /� 4�t�j Installer: �' // v � r,1�1 C'C*n�t ti(j Address: SL' ,�,z;'/ z 1,,,';,,2 Phone: 3 Phone: pc }c-3 _ / L '�, S )�� Builder: Address: Engineer: /9 ( (A jt /ic Phone: Phone: ;- _--s 7-2 i- )0, 1. Required#of copies received N.A7 I NO 2. Date of soils exam and percolation test not older than 2 years 3. 4-5 ft of naturally occurring pervious material,above water table J - - - 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: --- 5. Water line 10 ft from septic components Var.: - 6. Benchmark indicated and shown-NGVD if near wetlands 7. Septic sank minimum 10 ft from foundation, deck Var.: t/ 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I 9. Leaching minimum 100 ft from wetlands Var.: I ,/ 10. Leaching minimum 150 ft from drinking well/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 12. System meets all other setback requirements Var.: ` i 13. Uses adjustment for maximum high groundwater Var.: 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: 11/4/ I 15. System not in top or subsoil (A,B horizons)or 5' removal `� 16. Proposed contours are suitable 17. System meets slope requirements-min. 1/8", 1/4"preferred `� 18. System meets breakout requirements PVC liner: Wall: I .V 19. Specified tee sizes are proper, gas baffle on outlet teeV: 20. Sewage is under 10,000 gpd for parcel 21.No garbage disposal 22. System adequately sized for its intended use 23:Minimum 6"stone or compacted below tank and dbox I 24. Manhole covers within 6"of grade, pump chamber cover to grade '/ 25.Inspection port on plastic chambers/leach field 1,./ 1 26. Electrical permit for pump chamber/Separate meter for duplexes ',, 27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parking 30. Buoyancy calculations for tank/pump chamber y/ 1 31.Engineer to inspect and certify :/ soils: ,A all: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic, groundwater 34.Title V Application and permit fee, installer signature f 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: 37. Check area lots for groundwater/Label groundwater in Assessor's Map gpd ��,,) v I Plan reviewed by: ' J' 1': v1)