Loading...
HomeMy WebLinkAboutBlower Door Test 11722 K+ E Home Services Blower Door/Duct-Blaster Testing Building Performance Institute Certified Cell : 774-704-6117 Blower Door Test Results 1st CFM50 - 1481 Cfm50 2nd CFM50 - Accuracy Level-Standard Air Change per Hour @ 50 Pa- 2.31 ACH50 Effective Leakage Area (ELA)- 81.3 sq inch Customer Information Project Date - 1-17-22 Name - Tim Chapasko Address / Email -curbside20@gmail.com City - West Yarmouth , Ma Building Information Address -589 West Yarmouth Rd. City -West Yarmouth , Ma. Year Constructed -2021 Volume -38,500 Floor Area- 1925 sq ft Building Height-20 ft Test Readings Nominal Building Pressure --50 Pa Nominal Fan - 1,490 CFM Nominal Fan Pressure - 639.1 Pa Fan Configuration - Ring B Fan Model - Model 3 110v Pressure Gauge Model - DG-1000 Baseline Readings Average Baseline - 0.1 Baseline Range - 0.1 Notes : Performed By : Kyle Alexander BPI ID # 5061748 Date : 1-17-2022 Signature : Nee a&xantPer