Loading...
HomeMy WebLinkAboutBLDSM-22-007456 . Pea,AA;/ RECEIVED of-r�. SHEET METAL PERMIT JUN 24 2022 s j j Commonwealth of Massachusetts \w 77-' Town ofYarmouth BuildingDepartment BUILDING DEPARTMENT p By __------- 1146 Route 28, South Yarmouth, MA 02664-4492 Date: 6 /al ba_ Permit#: abSt1'1 --( 7�'S(O Estimated Job Cost: $ 30) C� Permit Fee: $ Sow eU_- I 0 O ct Plans Submitted: YES/ NO Plans Reviewed: YES/ NO Business License# 1 ti(1j c) Application License# Business Information Property Owner/Job Location Information Name:I\l/e5 I-h is , c-xr JI(-CI Inc Name: Street: '.)(3 fcxcm Q.c�11i Street: 3 11 6 r e cd I Sliknci ' ,b+ City/Town: Max- bosom ) WIIA,0i 7�� City/Town: (Jul esf YD,(Yn0ur��h Telephone: ( 5 0s) .3 (0l3 7) Telephone: Photo I.D. required/Copy of Photo I.D. attached: YES/ NO Staff Initial: 1-1/M-1 unrestricted license J-2/ M-2 restricted to dwellings 3 stories or less and commercial up to 10,000 sq. ft./ 2 stories or less Residential: 1-2 family I Multi-family Condo/Townhouses Other__ Commercial: Office Retail _Industrial Educational Institutional Other Square Footage:Foota e: under 10,000 sq. ft.I over 10,000 sq. ft._Number of stories: Sheet metal work to be completed: New work L Renovation: —HVAC: Metal Watershed Roofing:_ Kitchen Exhaust System: Metal Chimney/Vents: Air Balancing:_ Provide detailed description of work to be done:n + i O e' I be, A. •MK7v( 1triei �'n -4-I've. .J�T .XcIa`1�-( (J)i i ) r,cxni t'D • t.2Y1AA ,LO0Ir, ll/14 _ mc*' )niwe/ (al9t t1 i 7, r P. • A nJ CAI -Hrve, Y,d F Iovl w e u) t l l c d o dci i it,-, LA ><-h 0 Yve, INSURANCE COVERAGE: I have a current liability insura ce policy or its equivalent which meets the requirements of M.G.L. Ch. 11 2 Yes \No If you have checked Yes, indicate the type of coverage by checking the appropriate box below: A liability insurance policy ,,f Other type of indemnity Bond OWNER'S INSURANCE WAIVER: I am aware that the licensee does not have the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application waives this requirement. ,./ Check One Only / Owner Agent of Owner or Owner's Agent Bi checking here- ,I hereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installation performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Inspections shall be called for prior to insulation installation. Duct inspection required prior to insulation installation: Yes No Progress Inspections Date: Comments: Final Inspections Date: Comments: Type of license: Master By:Title: Master-Restricted '1` Signature of Licensee City/Town: Journeyperson Permit#: Journeyperson-Restricted License Number: Check at www.mass.gov/dpl Fee: $ '1` Inspector Signature of Permit '' of Permit Approval ® . ACC REPCERTIFICATE OF LIABILITY INSURANCE DATE(MMIDDNYYY) 06/21/2022 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER NAMEC r Certificate Department PHONE 508-875-3488 FAX No): 508-875-9388 A-Costa Insurance Agency Inc (A/c,No,Ext): ( 1 Franklin Cmns ADDRESS: coi@a-costains.com INSURER(S)AFFORDING COVERAGE NAIC# Framingham MA 01702 INSURERA: PROGRESSIVE 24252 INSURED INSURER B: ACE American Insurance Company 22667 ALVES HVAC SERVICES INC INSURER C: 8 CONNOR LANE INSURER D: INSURER E: BELLINGHAM MA 02019 INSURER F: COVERAGES CERTIFICATE NUMBER: REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. IN POLICY EFF POLICY EXP SR INSD WVD TYPE OF INSURANCE ADDLSUBR POLICY NUMBER (MM/DDIYYYY) (MM/DD//YYYY) LIMITS LT I COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 DAMAGE I KENIEU CLAIMS-MADE OCCUR PREMISES(Ea occurrence) $ 50,000 _1 MED EXP(Any one person) $ 1,000 3EZ5662 1/26/2022 1/26/2023 PERSONAL&ADV INJURY $ 1,000,000 i GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 I PRO- POLICY JECT LOC PRODUCTS-COMP/OP AGG $ 1,000,000 _ OTHER: AUTOMOBILE LIABILITY Enaccident) COMBINED SINGLE LIMI I $ (Ea ac ANY AUTO BODILY INJURY(Per person) $ 20,000 ALL OWNED SCHEDULED 02101046 8(23/2021 8l23/2022 BODILY INJURY(Per accident) $ 40,000 A AUTOS X AUTOS NON-OWNED PROPERTY DAMAGE $ 100,000 HIRED AUTOS AUTOS (Per accident) $ UMBRELLA LIAB OCCUR EACH OCCURRENCE $ EXCESS LIAB CLAIMS-MADE AGGREGATE $ DED I RETENTION$ $ WORKERS COMPENSATION X STATUTE ER PER H AND EMPLOYERS'LIABILITY Y I N ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 100,000 B OFFICER/MEMBER EXCLUDED? N N/A 001046757 1/28/2022 1/28/2023 E.L.DISEASE-EA EMPLOYEE $ 100,000 (Mandatory in NH) If yes,describe under DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ 500,000 DESCRIPTION OF OPERATIONS I LOCATIONS/VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS. Town of Yarmounth AUTHORIZED REPRESENTATIVE 1146 Route 28, raiMifeb ' i South Yarmounth MA 02664 ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts ....37 - Department of Industrial Accidents =;� _ Office of Investigations �'P. 600 Washington Street IL Boston,MA 02111 wwft.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual): \\CS 1-1 1,iGIL& Je( )I L(. c. Address: 1 ,) GI 'rat,,,, Kd City/State/Zip: Kai-1 c ov 4�)t 017 S- Phone#: (,�J1�3)0 M- 6/.,2 3 A • re ou an employer?Check the a ropriate box: I Type of project(required): 1.[ l ama employer with 4. ❑ I ant a general contractor and 6. 0 New construction employees(full and/or part-time).* have hired the sub-contractors 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. 0 Remodeling ship and have no employees These sub-contractors have 8. ❑Demolition working for me in any capacity. employees and have workers' 9. 0 Building addition [No workers'comp,insurance comp. insurance.# • required.] S. ❑ We area corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.0 lumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12. Roof repairs 0 insurance required.]t c. 152,§I(4),and we have no h�'� ►t, I employees.[No workers' 13. Other + comp.insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: 'f r av PA e t;5 .1n)(i fOrrY P. Policy#or Self-ins.Lie.#:OD .0(015 9 Expiration Date: I J 2 2/02 5 Job Site Address:FA 1 G 1 cc(," 141,E City/State/Zip:U.j -)- Gl f I-mu/ 7 h Attach a copy of the workers'compensation policy declaration page(showing the policy number nd expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of , Investigations of he DIA for insurance coverage verification. I do hereby • , r 'r t • ±ins and penalties of perjury that the information provided above is true and correct. ���i� Date: • Si_ ai :ar / i%i Phon: #: ( 9 S ' 3 `- ,2 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 1 Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: C, m m a ® Q - vn - w v -I c- 0 � 5 -n ZI 4G m aAQ C? , (I) d mSm -4 asD > n mm � >< A m -1 7r- v -15 13 Is.)— Nr =m fmaO zzxoco r00o- C0j 10 rs3 7IZ0 ZA m 0 73 7) n m r a m to -A m Z m = z r cfl p m ZC crs z co CO 3 a to M ea m cI mi '33 /.. mV) CENE SIGNATURE T' - 1 1 Job: 311 great island rd,west... ] ' fVAC Load Multizone Summary Report Date: Jun 13,2022 "" By: Filipe Souza Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM ft3 cfm Btuh/ft2 ft3 cfm Btu hlft2 2nd Floor 20538 0.27 91 2.1 20538 0.14 49 0 1st Floore 11445 0.30 58 2.1 11445 0.16 31 0 Entire House 31983 0.28 149 2.1 31983 0.15 80 0 Load and AVF Summary ROOM NAME Area Htg load Clg load Htg AVF Clg AVF ft2 Btuh Btuh cfm cfm Study Room 389 5396 1788 100 74 Bath 4 65 156 0 3 0 Bath 5 179 3062 598 57 25 Bedroom 4 615 8369 6666 155 275 Sunroom 932 9881 6033 182 249 Stairs 2 124 296 0 5 0 Room46 72 173 0 3 0 Reading Room 417 6472 4081 120 169 Stairs 3 68 1573 1242 29 51 2nd Floor 2860 35378 20408 653 843 1 Bedroom 2 127 1080 479 21 22 Bedroom 3 129 978 479 19 22 Bedroom 1 198 3047 1623 59 74 Bath 2 106 1653 1253 32 57 Bath 112 1566 1307 30 60 open Space 10 8 0 0 0 Stairs 25 19 0 0 0 Kitchen 261 3795 1590 74 72 Hall 2 57 978 0 19 0 Bath 3 32 596 381 12 17 utility 30 71 0 1 0 Hall 3 79 134 0 3 0 Hall 109 3534 608 68 28 Dining Room 321 2558 794 50 36 1st Floore 1594 20017 8514 388 388 Entire House 4454 55395 24328 1041 1231 2022-Jun-17 18:16.21 wlr !!?1 5 Right-Suite®U niv ersal 2021 21.0.08 RSU64567 Page 1 ...ownloads\Manual JslLipnick House Renovation.rup Calc=MJ8 Front Door faces: N YES MVAC Project Summary Job: 311 great island rd,west... Date: Jun 13,2022 _,—,. Entire House • By: FilipeSouza Project Information For: 311 great island rd,west Yarmouth Notes: Desi• n Information Weather: Buzzards Bay, MA, US Winter Design Conditions Summer Design Conditions Outside db 17 °F Outside db 74 °F Inside db 68 °F Inside db 75 °F Design TD 51 °F Design TD 0 °F Daily range L Relative humidity 50 % Moisture difference 34 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 55395 Btuh Structure 24328 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 55395 Btuh Use manufacturer's data n Rate/swing multiplier 0.79 Infiltration Equipment sensible load 19219 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft2) 4454 4454 Equipment latent load 1846 Btuh Volume (ft3) 31983 31983 Air changes/hour 0.28 0.15 Equipment Total Load(Sen+Lat) 21065 Btuh Equiv.AVF(cfm) 149 80 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrtatttsoft 2022-Jun-1718:16:21 -- Right-Suitee Universal 2021 21.0.08 RSU64567 Pa ACC : ...ownloads\Manual Js\Lipnick House Renovation.rup Caic=MJ8 Front Door faces: N ge 1 • !, Job: 311 great island rd,west... d Project Summary Date: Jun 13,2022 +.. Cn��r -o 1st Fl o o re • By: Filipe Souza Pro'ect Information For: 311 great island rd,west Yarmouth Notes: Desi• n Information Weather: Buzzards Bay, MA, US Winter Design Conditions Summer Design Conditions Outside db 17 °F Outside db 74 °F Inside db 68 °F Inside db 75 °F Design TD 51 °F Design TD 0 °F Daily range L Relative humidity 50 % Moisture difference 34 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20017 Btuh Structure 8514 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20017 Btuh Use manufacturer's data n Rate/swing multiplier 0.79 Infiltration Equipment sensible load 6726 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 0Structure Btuh Fireplaces 719 Btuh Ducts Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1594 1594 Equipment latent load 719 Btuh Volume (ft3) 11445 11445 Air changes/hour 0.30 0.16 Equipment Total Load (Sen+Lat) 7445 Btuh Equiv.AVF (cfm) 58 31 Req.total capacity at 0.70 SHR 0.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref 0 SEER Efficiency 80 AFUE Efficiency 0 Btuh Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 388 cfm 0. Actual air flow 388 cfm Actual air flow Air flow factor 0.019 cfm/Btuh Air flow factor 6 cfm/Btuhin H2O Static pressure 0 in H2O Static pressure Space thermostat Load sensible heat ratio 0.92 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 -i'it- wrtghtsoft Page 2 A z.; Right-Suite®Universal 2021 21.0.08 RSU64567 ACGI ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJB Front Door faces: N HVAC Project Summary Job: 311 great island rd,west... A Date: Jun 13,2022 4. c. , .,,,, H1 By: Filipe Souza Project Information For: 311 great island rd,west Yarmouth Notes: Desi• n Information Weather: Buzzards Bay, MA, US Winter Design Conditions Summer Design Conditions Outside db Outside db Inside db 68 °F Inside db 75 °F75 °F Design TD 51 °F Design TD 0 °F Daily range L Relative humidity 50 % Moisture difference 34 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 35378 Btuh Structure 15814 Btuh 0 Btuh Ducts Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower Piping 0 Btuh 0 Btuh Equipment load 35378 Btuh Use manufacturer's data Rate/swing multiplier 0.79n Infiltration Equipment sensible load 12493 Btuh Method Simplified Latent Cooling Construction quality Average Equipment Load Sizing Fireplaces 0 Structure 1127 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh 2 Heating Cooling (none) ( 2860 2860 Equipment ft ) latent load 1127 Btuh Volume (ft3) 20538 20538 Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 13620 Btuh Equiv. AVF (cfm) 91 49 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Concord Make Concord Trade CONCORD Trade CONCORD Model 80G1DF045AE12** Cond 4AC13*18P-10 AHRI ref 202181784 Coil EAH1P24A+80G1UH045AE12 Efficiency 80 AFUE AHRI ref 204826691 Heatingeinput Efficiency 12.5 EER, 15.5 SEER P 44000 Btuh Sensible cooling 13720 Btuh Heating output 36000 Btuh Latent cooling 5880 Btuh Temperature rise 50 °F Total cooling 19600 Btuh Actual air flow 653 cfm Actual air flow Air flow factor 0.018 cfm/Btuh Air flow factor64 cfm cf Static pressure 0.05 in H2O Static pressure 0.041 H2 uh Space thermostat Load sensible heat ratio 0.05 in H2O 0.93 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - 4+- wrisitstlaoft. ' • - Right-Suite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18:16:21 Page 3 ACC'', ...ownloads51anual Js\Lipnick House Renovation.rup Cale=MJ8 Front Door faces: N • Project Summary Job: 311 great island rd,west... , S HYAC Date: Jun 13,2022 2n a Floor ' By: Filipe Souza Pro'ect Information For: 311 great island rd,west Yarmouth Notes: Desi• n Information Weather: Buzzards Bay, MA, US Winter Design Conditions Summer Design Conditions Outside db 17 °F Outside db 74 °F Inside db 68 °F Inside db Design TD 51 °F Design TD 0 °F Daily range L Relative humidity 50 % Moisture difference 34 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 35378 Btuh Structure 20408 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 35378 Btuh Use manufacturer's data n Rate/swing multiplier 0.79 Infiltration Equipment sensible load 16122 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1127 Btuh Fireplaces 0 Structure Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ft2) 2860 2860 Equipment latent load 1127 Btuh Volume (ft3) 20538 20538 Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 17249 Btuh Equiv.AVF(cfm) 91 49 Req.total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Btuh Heating output 0 Btuh Latent cooling 00 Btuh Temperature rise 0 °F Total cooling 0 cfm Actual air flow 0 cfm Actual air flow 0 cfm/Btuh Air flow factor 0 cfm/Btuh Air flow factor 0 H2O Static pressure 0 in H2O Static pressure Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 1 ivF vrightsoft Page 4 Right-Suite®Universal 2021 21.0.08 RSU64567 ACC* ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N ; Es f4VAc AED Assessment Job: 311 great island rd,west... Entire House Date: Jun 13,2022 By: Filipe Souza Project Information For: 311 great island rd,west Yarmouth Design Conditions Location: Indoor: Heating Cooling Buzzards Bay, MA, US Indoor temperature (°F) 68 75 Elevation: 56 ft Design TD (°F) 51 0 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (grub) 40.7 34.0 Dry bulb(°F) 17 74 Infiltration: Daily range (°F) - 10 ( L ) Wet bulb(°F) - 69 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity I-tuly GlazingLoad 35,000-- 30,000-- 25,000-- 20,000- 15.000- 10,000- 5,000— 0 8 9 1I0 1I1 1I2 1I3 1I4 1I5 1I6 1I7 1I8 19 20 I pry Hour Po� AED Iimit Maximum hourly glazing load exceeds average by 18.2%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wrightsoft,. ^`+— - Right-Surte®Universal 202121.008 RSU64567 2022-Jun-1718:16.21 Page 1 AC ...ownloads\Manual Js\Lipnick House Renovation rup Calc=MJ8 Front Door faces: N Job: 311 great island rd,west... ,.. " AED Assessment ` k �'' HYAC Date: Jun 13,2022 4I 1st Flo o re By: Filipe Souza Project Information For: 311 great island rd,west Yarmouth Design Conditions Location: Indoor: Heating Cooling Buzzards Bay, MA, US Indoor temperature (°F) 68 75 Elevation: 56 ft Design TD (°F) 51 0 Latitude: 41°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(grub) 40.7 34.0 Dry bulb(°F) 17 74 Infiltration: Daily range(°F) - 10 ( L ) Wet bulb(°F) - 69 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity liallyGirg Load 11,00e 10,00! 9,OOe EE 5,OOe 4,00e 3,00e 2,000-- 1,000- 0 8 9 10 11 12 13 14 15 16 17 18 19 20 How of Day /Fb1Y /A y AEDimut Maximum hourly glazing load exceeds average by 21.2%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh wrightsoft` 2022-Jun-17 18:1621 .� -- Right-Suite®Universal 2021 21.0.08 RSU64567 Page 2 -,(- - ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N AED Assessment Job: 311 great island rd,west... I4 II' 5 HVAC Date: Jun 13,2022 0,01'6v c.., ,.s„A /Qn By: FifipeSouza Project Information For: 311 great island rd,west Yarmouth Design Conditions Location: Indoor: Heating Cooling Buzzards Bay, MA, US Indoor temperature (°F) 68 75 Elevation: 56 ft Design TD (°F) 51 0 Latitude: 41°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 40.7 34.0 Dry bulb(°F) 17 74 Infiltration: Daily range (°F) - 10 ( L ) Wet bulb(°F) - 69 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Gazing Lcad 24,0007 22,00 20,00 18,000- 16,000- 14,000- 12,000- 10,000- 8,000— 6,000- 4,000- 2,000- 0 I I I I I I I I I I I I 8 9 10 11 12 13 14 15 16 17 18 19 20 Har of OW /Hu* /Amp AEU Irma Maximum hourly glazing load exceeds average by 19.8%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh -pi- wrtghtsoft,. 2022-Jun-1718:16:21 Right-Suite® 2021 21.0.08 RSU64567 Page 3 ACCk ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N Job: 311 great island rd,west... AED Assessment -i ' $HVAC Date: Jun 13,2022 2nd Floor ' By: Fill eSouza Project Information For: 311 great island rd,west Yarmouth Design Conditions Location: Indoor: Heating Cooling Buzzards Bay, MA, US Indoor temperature (°F) 68 75 Elevation: 56 ft Design TD (°F) 51 0 Latitude: 41°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 40.7 34.0 Dry bulb(°F) 17 74 Infiltration: Daily range (°F) - 10 ( L ) Wet bulb(°F) 69 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity I-buly Gazing L,aad 24,00� 22,00 20,000-- 18,008- 16,008- 14,000- 12,008- 10,000- 8,000- 6,000- 4,000- 2,000- 0 1 8 9 10 11 12 13 14 1I 16 17 18 19 20 HardC y " Y a A.413 PEO limit Maximum hourly glazing load exceeds average by 19.8%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 4594 Btuh (PFG -ALP) -4- wrightsoft Right-Suttee)Universal 2021 21.0.08 RSU64567 2022-Jun-1718:16:21 Page 4 /CCk ...own load s\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N H<xf, . Right-J® Worksheet Job: 311 great island rd,west Ya... Entire House Date: Jun 13,2022 By: Filipe Souza 1 Room name Entire House 1st Floore 2 Exposed wall 559.6 ft 217.7 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 4453.5 ft' 1594.0 ft' i I i I i i Ty Construction U-value Or 1 HTM 1 Area (ft') Load 1 Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) 1 (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 1.615B-10sfc-2 0.083 n 3.92 0.00 382 303 1189 0 216 174 683 0 1D-c2ow 0.570 n 29.07 10.76 37 0 1066 395 0 0 0 0 11D0 0.390 n 19.89 0.00 42 42 835 0 42 42 835 0 15B-10sfc-22 0.083 ne 3.93 0.00 516 423 1663 0 127 98 381 0 11 1D-c2ow 0.570 ne 29.07 34.54 72 0 2103 2499 9 0 271 322 D 11 D0 0.390 ne 19.89 0.00 20 20 406 0 20 20 406 0 VJ 15B-10sfc-2 0.083 e 3.95 0.00 954 850 3362 0 351 319 1263 0 -G 1D-c2ow 0.570 e 29.07 52.71 104 0 3014 5464 32 0 930 1687 1/+J 15B-10sfc-2 0.083 se 3.93 0.00 261 218 860 0 153 110 428 0 L-G 1D-c2ow 0.570 se 29.07 44.49 43 0 1240 1898 43 0 1240 1898 VE_G15B-10sfc-2 0.083 s 3.93 0.00 1047 850 3335 0 360 336 1333 0 1D-c2ow 0.570 s 29.07 23.64 197 0 5727 4656 24 0 698 567 1/ 15B-10sfc-2 0.083 sw 3.94 0.00 293 252 992 0 242 201 789 0 1D-c2ow 0.570 sw 29.07 44.49 21 0 601 920 21 0 601 920 11 D0 0.390 sw 19.89 0.00 20 20 406 0 20 20 406 0 V+J 15B-10sfc-2 0.083 w 3.96 0.00 612 556 2200 0 45 33 128 0 G 1D-c20w 0.570 w 29.07 52.71 56 0 1638 2969 12 0 349 633 V+/ 15B-10sfc-2 0.083 nw 3.94 0.00 980 820 3228 0 471 399 1571 0 L-G 1D-c2ow 0.570 nw 29.07 34.54 160 0 4651 5527 72 0 2093 2487 C 16B-30ad 0.032 - 1.63 0.00 3556 3556 5804 0 697 697 1137 0 F 21B-28t 0.015 - 0.76 0.00 1594 1594 1219 0 1594 1594 1219 0 F 21B-28t 0.015 - 0.76 0.00 1962 1962 1501 0 0 0 0 0 I 6 c)AED excursion 0 0 Envelope loss/gain 47039 24328 16762 8514 12 a) Infiltration 8356 0 3254 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 55395 24328 20017 8514 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 55395 24328 20017 8514 15 Duct loads 0% 0% 0 0 0% 0% 0 0 Total room load 55395 24328 20017 8514 Air required(cfm) 1041 1231 388 388 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -1 wr•ico%txott 2022-Jun-1718:16:21 Right-Suite®Universal 2021 21.0.08 RSU64567 Page 1 _.ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N Right-.1® Worksheet Job: 311 great island rd,westYa... Entire House Date: Jun 13,2022 ' By: Filipe Souza 1 Room name AH1 2 Exposed wall 341.9 ft 3 Room height 9.0 ft 4 Room dimensions 5 Room area 2859.5 ft2 I I i I I i Ty Construction U-value Or I HTM Area (ft') I Load AreaI Load number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 151B-10sfc-2 0.083 n 3.92 0.00 166 129 506 0 1 D-c2ow 0.570 n 29.07 10.76 37 0 1066 395 11 DO 0.390 n 19.89 0.00 0 0 0 0 15B-10sfc-2 0.083 ne 3.93 0.00 389 326 1282 0 11 1D-c2ow 0.570 ne 29.07 34.54 63 0 1831 2176 D 11D0 0.390 ne 19.89 0.00 0 0 0 0 156-10sfc-2 0.083 e 3.95 0.00 603 531 2099 0 1D-c2ow 0.570 e 29.07 52.71 72 0 2083 3778 VJ 15B-l0sfc-2 0.083 se 3.93 0.00 108 108 432 0 -G 1D-c2ow 0.570 se 29.07 44.49 0 0 0 0 VEI 15B-10sfc-2 0.083 s 3.93 0.00 687 514 2002 0 G 1D-c2ow 0.570 s 29.07 23.64 173 0 5029 4089 15B-losfc-2 0.083 sw 3.94 0.00 51 51 203 0 1D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 D 11 D0 0.390 sw 19.89 0.00 0 0 0 0 y✓ 156-10sfc-2 0.083 w 3.96 0.00 567 523 2071 0 G 1D-c2ow 0.570 w 29.07 52.71 44 0 1289 2337 150-10sfc-2 0.083 nw 3.94 0.00 509 421 1657 0 1D-c2ow 0.570 nw 29.07 34.54 88 0 2558 3040 C 168-30ad 0.032 - 1.63 0.00 2860 2860 4667 0 F 21B-28t 0.015 - 0.76 0.00 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 1962 1962 1501 0 6 c)AED excursion 0 Envelope loss/gain 30277 15814 12 a) Infiltration 5102 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 35378 15814 Less external load 0 0 Less transfer 0 0 Redistribution 14 Subtotal 0 0 15 Duct loads 35378 15814 0% 0% 0 0 Total room load I I 35378 15814 Air required(cfm) 653 653 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrivalt_s.Kift "' Right-Suite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18:16:21 Page 2 _ L .ownloads\Manual JsIipnick House Renovation.rup Calc=MJ8 Front Door faces: N b" h. S 14VAC Right-J® Worksheet Job: 311 great island rd,west Ya... ' ems.,,ftft„.,:4 1st Floore Date: Jun 13,2022 By: Filipe Souza 1 Room name 1st Floore Bedroom 2 2 Exposed wall 217.7 ft 13.6 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 127.0 ft 5 Room area 1594.0 ft' 127.0 ft' TyConstruction U-value Or HTM Area (ft' Load Area ft' Load number I(Btuh/ft'-°F' I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) I Heat I Cool Gross N/P/S Heat I Cool Gross I N/P/S I Heat Cool I 6 1.615B-10sfc-2 0.083 n 3.92 0.00 216 174 683 0 0 0 0 0 1D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 19.89 0.00 42 42 835 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.91 0.00 127 98 381 0 0 0 0 0 11 1D-c2ow 0.570 ne 29.07 34.54 9 0 271 322 0 0 0 0 II 11 D0 0.390 ne 19.89 0.00 20 20 406 0 0 0 0 0 15B-10sfc-2 0.083 e 3.96 0.00 351 319 1263 0 36 36 143 0 1D-c2ow 0.570 e 29.07 52.71 32 0 930 1687 0 0 0 0 VI 15B-10sfc-2 0.083 se 3.89 0.00 153 110 428 0 51 39 153 0 G 1D-c2ow 0.570 se 29.07 44.49 43 0 1240 1898 12 0 339 519 Vt15B-10sfc-2 0.083 s 3.97 0.00 360 336 1333 0 36 36 143 0 -G 1D-c2ow 0.570 s 29.07 23.64 24 0 698 567 0 0 0 0 1 15B-10sfc-2 0.083 sw 3.93 0.00 242 201 789 0 0 0 0 0 Inc 1D-c2ow 0.570 sw 29.07 44.49 21 0 601 920 0 0 0 0 D 11 D0 0.390 sw 19.89 0.00 20 20 406 0 0 0 0 0 V)/ 15B-10sfc-2 0.083 w 3.89 0.00 45 33 128 0 0 0 0 0 � G 1D-c2ow 0.570 w 29.07 52.71 12 0 349 633 0 0 0 0 15B-10sfc-2 0.083 nw 3.94 0.00 471 399 1571 0 0 0 0 0 1D-c2ow 0.570 nw 29.07 34.54 72 0 2093 2487 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 697 697 1137 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 1594 1594 1219 0 127 127 97 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 -40 Envelope loss/gain 16762 8514 877 479 12 a) Infiltration 3254 0 204 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 20017 8514 1080 479 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20017 8514 1080 479 15 Duct loads 0% 0% 0 0 -0% 0% 0 0 Total room load I I I 20088I 85143881 I I 1080 4791 Air required(cfm) 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 i wrihta�®st Page 3 Right-Suite®Universal 2021 21.0.08 RSU64567 ...ownloads\Manual Js\Lipnick House Renovation.nip Calc=MJ8 Front Door faces: N • S;tv. .,,. Right-J® Worksheet Job: 311 great island rd,west Ya... Date: Jun 13,2022 1st Floore By: Filipe Souza 1 Room name Bedroom 3 Bedroom 1 2 Exposed wall 10.6 ft 33.7 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 129.0 ft 1.0 x 197.5 ft 5 Room area 129.0 ft' 197.5 ft' i I I I i I Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') I Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross 1 N/P/S Heat Cool Gross 1 N/P/S Heat Cool 6 15B-10sfc-2 0.083 n 3.92 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 n 19.89 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.91 0.00 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11D0 0.390 ne 19.89 0.00 0 0 0 0 0 0 0 0 V+J 15B-10sfc-2 0.083 e 3.96 0.00 9 9 36 0 45 45 179 0 l-G 1 D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 se 3.89 0.00 51 39 153 0 0 0 0 0 1D-c2ow 0.570 se 29.07 44.49 12 0 339 519 0 0 0 0 158-10sfc-2 0.083 s 3.97 0.00 36 36 143 0 99 75 293 0 1D-c2ow 0.570 s 29.07 23.64 0 0 0 0 24 0 698 567 T 2V)/ 15B-10sfc-2 0.083 sw 3.93 0.00 0 0 0 0 38 27 103 0 I! G 1D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 12 0 339 519 D 11 D0 0.390 sw 19.89 0.00 0 0 0 0 0 0 0 0 V 15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 45 33 128 0 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 12 0 349 633 Vr 15B-10sfc-2 0.083 nw 3.94 0.00 0 0 0 0 76 76 304 0 1D-c2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 30 30 49 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 129 129 99 0 198 198 151 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -40 96 Envelope loss/gain 819 479 2544 1623 12 a) Infiltration 159 0 503 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 978 479 3047 1623 Less external load 0 0 0 0 Less transfer Redistribution 0 0 0 0 0 14 Subtotal 978 479 0 0 3047 1623 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load 978 479 3047 1623 Air required(cfm) I 19I 22 I 59 74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ..,� Right-Suite®U niv ersal 2021 21.0.08 RSU64567 2022-Jun-17 18.16:21 Page 4 _.ownloads1Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N Right-J® Worksheet Job: 311 great island rd,west Ya... {`, x Date: Jun 13,2022 S t F� 0 re By: Filipe Souza 1 Room name Bath 2 Bath 2 Exposed wall 12.7 ft 9.8 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 105.5 ft 1.0 x 112.0 ft 5 Room area 105.5 ft' 112.0 ft' I I Ty Construction U-value Or I HTM I Area (ft') I Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat I Cool 1 Gross I N/P/S Heat Cool 6 V+J 15B-10sfc-2 0.083 n 3.92 0.00 0 0 0 0 0 0 0 0 ;LAC 1 D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 11 D0 0.390 n 19.89 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.91 0.00 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11 D0 0.390 ne 19.89 0.00 0 0 0 0 0 0 0 0 VIJ 15B-10sfc-2 0.083 e 3.96 0.00 0 0 0 0 0 0 0 0 G 1D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 Vt15B-l0sfc-2 0.083 se 3.89 0.00 0 0 0 0 0 0 0 0 G 1 D-c2ow 0.570 se 29.07 44.49 0 0 0 0 0 0 0 0 VN 15B-10sfc-2 0.083 s 3.97 0.00 0 0 0 0 0 0 0 0 C, 1D-c2ow 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 V}! 15B-10sfc-2 0.083 sw 3.93 0.00 25 25 101 0 0 0 0 0 I^�; 1 D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 0 0 0 0 D 11 D0 0.390 sw 19.89 0.00 0 0 0 0 0 0 0 0 V)1 15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 0 0 0 0 -� 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 V)J 15B-10sfc-2 0.083 nw 3.94 0.00 89 58 225 0 89 57 219 0 C 1D-c2ow 0.570 nw 29.07 34.54 31 0 891 1059 32 0 930 1105 C 16B-30ad 0.032 - 1.63 0.00 101 101 164 0 112 112 183 0 F 21B-28t 0.015 - 0.76 0.00 106 106 81 0 112 112 86 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 193 202 Envelope loss/gain 1463 1253 1418 1307 12 a) Infiltration 190 0 148 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1653 1253 1566 1307 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1653 1253 1566 1307 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 Total room load I 16531 12531 1566 1307 Air required(cfm) 32 57 30 60 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - d-- wr i01-11 1"1 2022-Jun-17 18:16:21 Right-Suite®Universal 2021 21.0.08 RSU64567 Page 5 ._ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N Right-J® Worksheet Job: 311 great island rd,westYa... 1$t F1 re Date: Jun 13,2022 By: Filipe Souza 1 Room name open Space Stairs 2 Exposed wall 0 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 5.0 x 2.0 ft 5.0 x 5.0 ft 5 Room area 10.0 ft' 25.0 ft' i i i I I i Ty Construction U-value Or I HTM I Area (ft') Load Area (ft ) I Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) 1 (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 15B-10sfc-2 0.083 n 3.92 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 11 D0 0.390 n 19.89 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.91 0.00 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11 D0 0.390 ne 19.89 0.00 0 0 0 0 0 0 0 0 t_ 15B-10sfc-2 0.083 e 3.96 0.00 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 V✓ 15B-10sfc-2 0.083 se 3.89 0.00 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 se 29.07 44.49 0 0 0 0 0 0 0 0 t_G15B-10sfc-2 0.083 s 3.97 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 V� 15B-l0sfc-2 0.083 sw 3.93 0.00 0 0 0 0 0 0 0 0 I! G 1D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 0 0 0 0 D 11 D0 0.390 sw 19.89 0.00 0 0 0 0 0 0 0 0 1/L_G 15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 nw 3.94 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 0 0 0 0 0 0 0 0 F 21 B-28t 0.015 - 0.76 0.00 10 10 8 0 25 25 19 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 0 Envelope loss/gain 8 0 19 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 8 0 19 0 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 8 0 19 0 -0% 0% 0 0 -0% 0% 0 0 I I Total room load Air required(cfm) 0 0 I 10 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t- Rig ht-Suite®Universal2021 21.0.08 RSU64567 2022-Jun-17 18:16:21 Page 6 ...ownloads\Manual JslLipnick House Renovation.rup Calc=MJ8 Front Door faces: N '"V g 14VAC Right-J® Worksheet Job: 311 great island rd,westYa... A,.m.4,a".,.ti.,..;.F ., 1 S t Flo o re Date: Jun 13,2022 By: Filipe Souza • 1 Room name Kitchen Hall 2 2 Exposed wall 43.4 ft 18.3 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 261.0 ft 1.0 x 57.0 ft 5 Room area 261.0 ft' 57.0 ft' I ' I Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') I Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool I Gross I N/P/S Heat I Cool I Gross 1 N/P/S Heat Cool 6 15B-losfc-2 0.083 n 3.92 0.00 135 • 114 449 0 0 0 0 0 1D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 1100 0.390 n 19.89 0.00 21 21 418 0 0 0 0 0 15B-l0sfc-2 0.083 ne 3.91 0.00 0 0 0 0 0 0 0 0 11 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11D0 0.390 ne 19.89 0.00 0 0 0 0 0 0 0 0 Vr15B-10sfc-2 0.083 e 3.96 0.00 126 94 366 0 0 0 0 0 �G 1D-c2ow 0.570 e 29.07 52.71 32 0 930 1687 0 0 0 0 IN 15B-losfc-2 0.083 se 3.89 0.00 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 se 29.07 44.49 0 0 0 0 0 0 0 0 Ut1 15B-losfc-2 0.083 s 3.97 0.00 54 54 215 0 0 0 0 0 L-( 1D-c2ow 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 V 15B-10sfc-2 0.083 sw 3.93 0.00 0 0 0 0 76 76 304 0 1D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 0 0 0 0 11 D0 0.390 sw 19.89 0.00 0 0 0 0 0 0 0 0 Vr15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 0 0 0 0 C, 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 Vi! 15B-10sfc-2 0.083 nw 3.94 0.00 76 76 304 0 89 89 355 0 C, 1D-c2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 162 162 265 0 1 1 1 0 F 21B-28t 0.015 - 0.76 0.00 261 261 200 0 57 57 44 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 97 0 Envelope loss/gain 3147 1590I 704 0 12 a) Infiltration 648 0 274 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 3795 1590 978 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3795 1590 978 0 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 I Total room load I I I 3795I 159072I I I 9178 9 I o I Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -f4t- wr.i,gr.tzort- 2022-Jun-17 18:16:21 -*- Right-Suite®U niv ersal 2021 21.0.08 RSU64567 Page 7 ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N `'# £S VAC Right-J® Worksheet Job: 311 great island rd,westYa... ��� Date: Jun 13,2022 By: Filipe Souza 1 Room name Bath 3 utility 2 Exposed wall 5.6 ft 0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 32.0 ft 1.0 x 29.5 ft 5 Room area 32.0 ft' ' 29.5 ft I 1 I t I Ty Construction U-value Or I HTM Area (ft') Load I Area (ft') ILoad number (Btuh/ft'-°F) (Btuh/ft') I or perimeter (ft) (Btuh or perimeter (ft) (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 1. 15B-10sfc-2 0.083 n 3.92 0.00 0 0 0 0 0 0 0 0 �DG, 1 D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 11D0 0.390 n 19.89 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.91 0.00 0 0 0 0 0 0 0 0 11 1 D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11 D0 0.390 ne 19.89 0.00 0 0 0 0 0 0 0 0 1N 15B-10sfc-2 0.083 e 3.96 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 VJ 15B-10sfc-2 0.083 se 3.89 0.00 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 se 29.07 44.49 0 0 0 0 0 0 0 0 VE 15B-10sfc-2 0.083 s 3.97 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 sw 3.93 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 0 0 0 0 11 D0 0.390 sw 19.89 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 V 15B-10sfc-2 0.083 nw 3.94 0.00 51 42 163 0 0 0 0 0 L- G 1D-c2ow 0.570 nw 29.07 34.54 9 0 271 322 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 32 32 52 0 30 30 48 0 F 218-28t 0.015 - 0.76 0.00 32 32 24 0 30 30 23 0 F 21 B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 59 0 Envelope loss/gain 511 381 71 0 12 a) Infiltration 4 b) Room ventilation 80 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 596 381 71 0 Less external load Less transfer 0 0 0 0 Redistribution 0 0 14 Subtotal 0 0 0 0 15 Duct loads 596 381 71 0 -0% 0% 0 0 -0% 0% 0 0 Total room load I I 592 3871 I 71 0 Air required(cfm) 1 0I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ v.w s'Igtits.c34t 4C Right-Suite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18:16:21 Page 8 ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces N V S}rvac Right-J® Worksheet Job: 311 great island rd,west Ya.,. Date: Jun 13,2022 , R4a 1st Floore By: Filipe Souza • 1 Room name Hall 3 Hall 2 Exposed wall 0 ft 36.4 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 79.0 ft 1.0 x 108.5 ft 5 Room area 79.0 ft' 108.5 ft' 1 I I 1 I i Ty Construction U-value Or I HTM I Area (ft') I Load I Area (ft') I Load number (Btuh/ft'-'F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) I I I Cool I Gross I N/P/S I Heat I Cool I Gross Heat N/P/S I Heat Cool 6 V� 15B-l0sfc-2 0.083 n 3.92 0.00 0 0 0 0 81 60 234 0 1 D-c2ow 0.570 n 0.00 0.00 0 0 0 0 0 0 0 0 D 11 D0 0.390 n 19.89 0.00 0 0 0 0 21 21 418 0 15B-l0sfc-2 0.083 ne 3.91 0.00 0 0 0 0 127 98 381 0 11 1 D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 9 0 271 322 I D 11 D0 0.390 ne 19.89 0.00 0 0 0 0 20 20 406 0 l -G 150-10sfc-2 0.083 e 3.96 0.00 0 0 0 0 18 18 72 0 1 D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 V+J 15B-10sfc-2 0.083 se 3.89 0.00 0 0 0 0 0 0 0 0 � G 1 D-c2ow 0.570 se 29.07 44.49 0 0 0 0 0 0 0 0 Vr_G15B-losfo-2 0.083 s 3.97 0.00 0 0 0 0 0 0 0 0 1D-c20w 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 y! 15B-l0sfo-2 0.083 sw 3.93 0.00 0 0 0 0 102 72 281 0 1D-c2ow 0.570 sw 29.07 44.49 0 0 0 0 9 0 262 400 11 D0 0.390 sw 19.89 0.00 0 0 0 0 20 20 406 0 V)t 15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 0 0 0 0 C, 1 D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 Vl/ 15B-10sfc-2 0.083 nw 3.94 0.00 0 0 0 0 0 0 0 0 I-G 1D-c2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 45 45 74 0 109 109 177 0 F 21B-28t 0.015 - 0.76 0.00 79 79 60 0 109 109 83 0 F 218-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion 0 -115 Envelope loss/gain 134 0 2991 608 12 a) Infiltration 0 0 543 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 134 0 3534 608 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 134 0 3534 608 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 I Total room load I I I 134I l 0I I I 3534 608 Air required(cfm) 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 _ r}t w.�+pir+tsart Page 9 Right-Suite8 U niv ersal 2021 21.0.08 RSU64567 '( ' ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N ttif.S}#\'fit Right-J® Worksheet Job: 311 great island rd,west Ya... S Flo ore Date: Jun 13,2022 By: Filipe Souza 1 Room name Dining Room 2 Exposed wall 33 6 ft 3 Room height 9-0 ft heat/cool 4 Room dimensions 1.0 x 321.0 ft 5 Room area 321.0 ft' i I i Ty Construction U-value Or HTM Area (ft') Load I Area Load number (Btuh/ft'-°F; (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ 15B-10sfc-2 0.083 n 3.92 0.00 0 0 0 0 -p 1 D-c2ow 0.570 n 0.00 0.00 0 0 0 0 11 D0 0.390 n 19.89 0.00 0 0 0 0 15B-10sfo 2 0.083 ne 3.91 0.00 0 0 0 0 11 1D-c2ow 0-570 ne 29.07 34.54 0 0 0 0 D 11 DO 0.390 ne 19-89 0.00 0 0 0 0 V+/ 15B-10sfc-2 0.083 e 3.96 0.00 117 117 466 0 G 1D-c2ow 0.570 e 29.07 52.71 0 0 0 0 15B-10sfc-2 0.083 se 3.89 0.00 51 32 121 0 1 D-c2ow 0.570 se 29.07 44.49 19 0 562 860 15B-10sfc-2 0.083 s 3.97 0.00 135 135 538 0 1 D-c2ow 0.570 s 29.07 23.64 0 0 0 0 15B-10sfc-2 0.083 sw 3.93 0.00 0 0 0 0 1 D-c2ow 0.570 sw 29.07 44-49 0 0 0 0 11D0 0.390 sw 19.89 0.00 0 0 0 0 15B-10sfc-2 0.083 w 3.89 0.00 0 0 0 0 1 D-c2ow 0.570 w 29.07 52.71 0 0 0 0 V)!L- 15B-10sfc-2 0.083 nw 3.94 0.00 0 0 0 0 G 1 D-c2ow 0-570 nw 29.07 34.54 0 0 0 0 C 168-30ad 0.032 - 1.63 0.00 76 76 124 0 F 210-28t 0.015 - 0.76 0.00 321 321 246 0 F 218-28t 0-015 - 0.00 0.00 0 0 0 0 6 c)AED excursion -66 Envelope loss/gain 2057 794 12 a) Infiltration b) Room ventilation 502 0 0 0 13 Internal gains: Occupants @ 230 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 2558 794 Less external load Less transfer 0 0 Redistribution 0 0 14 Subtotal 0 0 15 Duct loads 2558 794 -0% 0% 0 0 Total room load Air required(cfm) I 25581 7941 I I 50 36 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4'4, w.-+Stt-Irmort- Right-Suite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18.16:21 Page 10 ..ownloads\Manual Js\Lipnick House Renovation-rup Calc=MJ8 Front Door faces: N S HMAC Right-J® Worksheet Job: 311 great island rd,westYa... .. a�•'„ , A H 1 Date: Jun 13,2022 By: Filipe Souza 1 Room name AH1 2nd Floor 2 Exposed wall 341.9 ft 341.9 ft 3 Room height 9.0 ft 9.0 ft 4 Room dimensions 5 Room area 2859.5 ft' 2859.5 ft' I I Ty Construction ' U-value I Or I HTM I Area (ft') I Load I Area (ft') I Load number (Btuh/ft'-°F (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat I Cool I Gross I N/P/S Heat I Cool 6 6 156-10sfc-2 0.083 n 3.91 0.00 166 129 506 0 166 129 506 0 1D-c2ow 0.570 n 29.07 10.76 37 0 1066 395 37 0 1066 395 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.94 0.00 389 326 1282 0 389 326 1282 0 11 1D-c2ow 0.570 ne 29.07 34.54 63 0 1831 2176 63 0 1831 2176 11�� 11D0 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 1y 15B-10sfc-2 0.083 e 3.95 0.00 603 531 2099 0 603 531 2099 0 I--C 1D-c2ow 0.570 e 29.07 52.71 72 0 2083 3778 72 0 2083 3778 Val 15B-10sfc-2 0.083 se 3.98 0.00 108 108 432 0 108 108 432 0 �G 1D-c2ow 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 VL-G 15B-10sfc-2 0.083 s 3.90 0.00 687 514 2002 0 687 514 2002 0 1D-c20w 0.570 s 29.07 23.64 173 0 5029 4089 173 0 5029 4089 VU 15B-10sfc-2 0.083 sw 3.98 0.00 51 51 203 0 51 51 203 0 II-c_ 1D-c2ow 0.570 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11 D0 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 w 3.96 0.00 567 523 2071 0 567 523 2071 0 1D-c2ow 0.570 w 29.07 52.71 44 0 1289 2337 44 0 1289 2337 V/1 15B-10sfc-2 0.083 nw 3.93 0.00 509 421 1657 0 509 421 1657 0 G 1D-c20w 0.570 nw 29.07 34.54 88 0 2558 3040 88 0 2558 3040 C 16B-30ad 0.032 - 1.63 0.00 2860 2860 4667 0 2860 2860 4667 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21 B-28t 0.015 - 0.76 0.00 1962 1962 1501 0 1962 1962 1501 0 6 c)AED excursion 0 4594 Envelope loss/gain 30277 15814 30277 20408 12 a) Infiltration 5102 0 5102 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 35378 15814 35378 20408 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 0 0 Redistribution 35378 15814 35378 20408 14 Subtotal 15 Duct loads 0% 0% 0 0 0% 0% 0 I Total room load I I I 353786531 15653I I I 35653378 I 204084381 Air required(cfm) l Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 s{.► wr igr.tott Page 11 Right-Suite®Universa12021 21.0.08 RSU64567 ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N .• ,V ; , , Right-J® Worksheet Job: 311 great island rd,west Ya... 2nd Floor Date: Jun 13,2022 By: Filipe Souza 1 Room name 2nd Floor Study Room 2 Exposed wall 341.9 ft 60.2 ft 3 Room height 9.0 ft 9.0 ft heat/cool 4 Room dimensions 1.0 x 388.5 ft 5 Room area 2859.5 ft' 388.5 ft' i II Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V� 15B-l0sfc-2 0.083 n 3.91 0.00 166 129 506 0 0 0 0 0 1 D-c2ow 0.570 n 29.07 10.76 37 0 1066 395 0 0 0 0 D 11 DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 158-10sfc-2 0.083 ne 3.94 0.00 389 326 1282 0 217 188 741 0 11 1D-c2ow 0.570 ne 29.07 34.54 63 0 1831 2176 29 0 843 1002 D 11 D0 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 Vr! 15B-10sfc-2 0.083 e 3.95 0.00 603 531 2099 0 45 45 179 0 -C 1 D-c2ow 0.570 e 29.07 52.71 72 0 2083 3778 0 0 0 0 VI! 15B-10sfc-2 0.083 se 3.98 0.00 108 108 432 0 13 13 51 0 L G 1D-c2ow 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 VE 15B-10sfc-2 0.083 s 3.90 0.00 687 514 2002 0 0 0 0 0 I-� 1D-c2ow 0.570 s 29.07 23.64 173 0 5029 4089 0 0 0 0 15B-10sfc-22 0.083 sw 3.98 0.00 51 51 203 0 51 51 203 0 1D-c2ow 0.570 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11 D0 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 w 3.96 0.00 567 523 2071 0 0 0 0 0 1D-c2ow 0.570 w 29.07 52.71 44 0 1289 2337 0 0 0 0 VU 15B-10sfc-2 0.083 nw 3.93 0.00 509 421 1657 0 217 189 746 0 L-� 1D-c2ow 0.570 nw 29.07 34.54 88 0 2558 3040 28 0 804 956 C 16B-30ad 0.032 - 1.63 0.00 2860 2860 4667 0 389 389 634 0 F 21 B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 1962 1962 1501 0 389 389 297 0 6 c)AED excursion 4594 -169 Envelope loss/gain 30277 20408 4498 1788 12 a) Infiltration b) Room ventilation 5102 0 898 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 Appliances/other0 0 0 0 0 Subtotal(lines 6 to 13) 35378 20408 5396 1788 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 0% 0% 353788 20408 5396 1788 0 -0% 0% 0 0 Total room load I Air required(cfm) 35378 20408 5396 1788 653 843 100 74 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .-#'4' MY/w' f7ti0YY Right-Suite®U niv ersal 2021 21.0.08 RSU64567 2022-Jun-1718:16:21 Page 12 ...own loads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N f•,,,, Right-J® Worksheet Job: 311 great island rd,west Ya... 2 n d Floor Date: Jun 13,2022 By: Filipe Souza 1 Room name Bath 4 Bath 5 2 Exposed wall 0 ft 35.4 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 13.0 x 5.0 ft 1.0 x 179.0 ft 5 Room area 65.0 ft' 179.0 ft' i Ty Construction U-value Or HTM Area (ft') Load Area (ft') Load number (Btuh/ft�'F) I (Btuh/ft') or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) Heat Cool Gross I N/P/S Heat I Cool Gross N/P/S Heat Cool 6 15B-losfc-2 0.083 n 3.91 0-00 0 0 0 0 166 129 506 0 1 D-c2ow 0-570 n 29.07 10.76 0 0 0 0 37 0 1066 395 11 D0 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 v✓ 15B-10sfc-2 0.083 ne 3.94 0.00 0 0 0 0 0 0 0 0 11 �-- G 1 D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11D0 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 VJ 15B-10sfc-2 0.083 e 3.95 0.00 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 VJ 15B-10sfc-2 0.083 se 3.98 0.00 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 V�! 15B-10sfc-2 0.083 s 3.90 0.00 0 0 0 0 0 0 0 0 �-G 1 D-c2ow 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 sw 3.98 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11 D0 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 V}J 158-10sfc-2 0.083 w 3.96 0.00 0 0 0 0 153 153 610 0 l G 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 VJ 15B-10sfc-2 0.083 nw 3.93 0.00 0 0 0 0 0 0 0 0 -G 1 D-c2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 65 65 106 0 179 179 292 0 F 21 B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 65 65 50 0 78 78 60 0 6 c)AED excursion 0 203 Envelope loss/gain 156 0 2533 598 12 a) Infiltration 0 0 528 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 156 0 3062 598 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 156 0 3062 598 14 Subtotal -0% 0% 0 0 -0% 0% 0 0 15 Duct loads Total room load 57 25 I 1561 DI 3062 5981 Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 �'� W�l+�liyroTt Page 13 Right-Su ite®Universal 2021 21.0.08 RSU64567 ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N • • ,, 1 AC Right-J® Worksheet Job: 311 great island rd,west Ya... 2n d Floor Date: Jun 13,2022 By: Filipe Souza 1 Room name Bedroom 4 Sunroom 2 Exposed wall 72.3 ft 96.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 615.0 ft 1.0 x 932.0 ft 5 Room area 615.0 ft' 932.0 ft' i i i Ty Construction U-value Or HTM I Area (ft') Load Area (ft') Load number (Btuh/ft'-°F) (Btuh/ft') or perimeter (ft) I (Btuh) i or perimeter (ft) I (Btuh) Heat Cool Gross I N/P/S Heat Cool Gross N/P/S Heat Cool 6 VIJ 15B-10sfc-2 0.083 n 3.91 0.00 0 0 0 0 0 0 0 0 IL-G_p 1 D-c2ow 0.570 n 29.07 10.76 0 0 0 0 0 0 0 0 11 D0 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 156-10sfc-2 0.083 ne 3.94 0.00 0 0 0 0 0 0 0 0 1 1 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 D 11 D0 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 e 3.95 0.00 261 213 837 0 297 273 1083 0 1D-c2ow 0.570 e 29.07 52.71 48 0 1395 2530 24 0 688 1247 VJ 15B-10sfc-2 0.083 se 3.98 0.00 0 0 0 0 0 0 0 0 -G 1D-c2ow 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 s 3.90 0.00 234 186 729 0 297 209 811 0 1D-c2ow 0.570 s 29.07 23.64 48 0 1395 1135 88 0 2558 2080 15B-10sfc-2 0.083 sw 3.98 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 D0 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 w 3.96 0.00 144 100 386 0 270 270 1076 0 1D-c2ow 0.570 w 29.07 52.71 44 0 1289 2337 0 0 0 0 Vr 15B-10sfc-2 0.083 nw 3.93 0.00 13 13 51 0 0 0 0 0 C 1D-c2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 615 615 1004 0 932 932 1521 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 267 267 204 0 932 932 713 0 6 c)AED excursion 665 2705 Envelope loss/gain 7289 6666 8450 6033 12 a) Infiltration b) Room ventilation 1080 0 1431 0 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 Appliances/other 0 0 0 Subtotal(lines 6 to 13) 8369 6666 9881 6033 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 8369 6666 9881 6033 -0% 0% 0 0 -0% 0% 0 0 Total room load Air required(cfm) I 8369 6666 I 9881 I 6033 155 275I 182 249 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI•itW t;p?t Right-Suite®U niv ersal 2021 21.0.08 RSU64567 2022-Jun-1718.16:21 Page 14 _.own loads1Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N `. 5 HVAC Right-J® Worksheet Job: 311 great island rd,west Ya... 2nd Floor Date: Jun 13,2022 By: Filipe Souza 1 Room name Stairs 2 Room46 2 Exposed wall O ft O ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 123.5 ft 1.0 x 72.0 ft 5 Room area 123.5 ft' 72.0 ft' ' ' ' T Construction U-value Or HTM Area ft' Load Area ft') Load y number (Btuh/ft'-'F I (Btuh/ft') I or perimeter (ft) I (Btuh) I or perimeter (ft) I (Btuh) I IHeat I Cool Gross N/P/S Heat I Cool Gross I N/P/S Heat I Cool 6 V. 15B-10sfc-2 0.083 n 3.91 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 n 29.07 10.76 0 0 0 0 0 0 0 0 11 D0 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 v� 15B-10sfc-2 0.083 ne 3.94 0.00 0 0 0 0 0 0 0 0 11 �-G 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 0 0 0 0 II D 11D0 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 VL__G 156-10sfc-2 0.083 e 3.95 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 e 29.07 52.71 0 0 0 0 0 0 0 0 V+J 15B-10sfc-2 0.083 se 3.98 0.00 0 0 0 0 0 0 0 0 t C 1 D-c2ow 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 1/ C 15B-losfc-2 0.083 s 3.90 0.00 0 0 0 0 0 0 0 0 1 D-c2ow 0.570 s 29.07 23.64 0 0 0 0 0 0 0 0 V 156-10sfc-2 0.083 sw 3.98 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 sw 0.00 0.00 0 0 0 0 0 0 0 0 D 11 D0 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 vf1 15B-10sfc-2 0.083 w 3.96 0.00 0 0 0 0 0 0 0 0 �G 1 D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 V)! 15B-10sfc-2 0.083 nw 3.93 0.00 0 0 0 0 0 0 0 0 C 1 Dc2ow 0.570 nw 29.07 34.54 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 124 124 202 0 72 72 118 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 124 124 94 0 72 72 55 0 6 c)AED excursion 0 0 Envelope loss/gain 296 0 173 0 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 296 0 173 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 296 0 173 0 15 Duct loads -0% 0% 0 0 -0% 0% 0 0 I I TotalAirreq roomuired loa(cfmd ) I I I 295I o0f I I 1731 01 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2022-Jun-17 18:16:21 �i.► wrlgFttamort Page 15 Rig ht-Suite®Universal 2021 21.0.08 RSU64567 eC 1. ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N s ti ,C. 2n d Floor Right-.1® Worksheet Job: 311 great island rd,westYa... Date: Jun 13,2022 By: Filipe Souza 1 Room name Reading Room Stairs 3 2 Exposed wall 66 0 ft 12.0 ft 3 Room height 9.0 ft heat/cool 9.0 ft heat/cool 4 Room dimensions 1.0 x 416.5 ft 1.0 x 68.0 ft 5 Room area 4165 ft' 68.0 ft' I I I I Load Ty Construction U-value Or HTM I Area (ft') I Load Area (ft') I number (Bt uh/f t'-°F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V)J 15B-tOsfc-2 0.083 n 3.91 0.00 0 0 0 0 0 0 0 0 L-pG 1 D-c2ow 0.570 n 29.07 10.76 0 0 0 0 0 0 0 0 11DO 0.390 n 0.00 0.00 0 0 0 0 0 0 0 0 15B-10sfc-2 0.083 ne 3.94 0.00 64 64 254 0 108 74 288 0 1 1 1D-c2ow 0.570 ne 29.07 34.54 0 0 0 0 34 0 988 1174 D 11D0 0.390 ne 0.00 0.00 0 0 0 0 0 0 0 0 1/ 15B-10sfc-2 0.083 e 3.95 0.00 0 0 0 0 0 0 0 0 I G 1D-c2ow 0.570 e 29.07 5271 0 0 0 0 0 0 0 0 V 15B-10sfc-2 0.083 se 3.98 0.00 96 96 381 0 0 0 0 0 l-G 1D-c2ow 0.570 se 0.00 0.00 0 0 0 0 0 0 0 0 VW 15B-10sfc-2 0.083 s 3.90 0.00 155 118 462 0 0 0 0 0 1 D-c2ow 0.570 s 29.07 23.64 37 0 1076 875 0 0 0 0 V 15B-10sfc-2 0.083 sw 3.98 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 sw 0.00 0.00 0 0 0 0 0 0 0 0 11 DO 0.390 sw 0.00 0.00 0 0 0 0 0 0 0 0 11L_G 15B-10sfc-2 0.083 w 3.96 0.00 0 0 0 0 0 0 0 0 1D-c2ow 0.570 w 29.07 52.71 0 0 0 0 0 0 0 0 Vv 15B-10sfc-2 0.083 nw 3.93 0.00 280 220 860 0 0 0 0 0 I-( 1D-c2ow 0.570 nw 29.07 34.54 60 0 1754 2084 0 0 0 0 C 16B-30ad 0.032 - 1.63 0.00 417 417 680 0 68 68 111 0 F 21B-28t 0.015 - 0.00 0.00 0 0 0 0 0 0 0 0 F 21B-28t 0.015 - 0.76 0.00 28 28 21 0 9 9 7 0 6 c)AED excursion 1122 67 Envelope loss/gain 5487 4081 1394 1242 12 a) Infiltration b) Room ventilation 980 0 180 0 0 0 13 Internal gains: Occupants© 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 6472 4081 1573 1242 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 6472 4081 1573 1242 0/ 0% 0 0 -0% 0% 0 0 I I Total ro Air re("rot uiredomload(cfm) I I I 64202I 4088�1I I I 1573 1251 I 1. Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - .- wrts,...tscstt 4567 e sal ownloads\Manual Js\Lipnick House Renovation rup rCalco MJ81 Fo.0.0nt DooRSUsfaces- N 2022-Jun-17 18:16:21 \ Page 16 Level 2 I Stairs 3 Study Room Reading Room Bath 41 I 'Stairs 2 (}( ® Room46 Bath 5 Ij Sunroom Bedroom 4 . I Job#: 311 great island rd,west Yarmouth Scale: 1 : 148 Performed by Filipe Souza for: Page 1 RightSuite®Universal 2021 311 great island rd,west Yarmouth 21.0.08 RSU64567 2022-Jun-17 18:16:37 Js\Lipnick House Renovation.rup N *Oel 11 71 Level I l Hatt' ./...-11 BatikKitchen uti Bail Stairs —1 . n Space Bath j \7 Hag9c� Dining Room !J' Bedroot 3 Hat N i Bedrnot 2 ... ......../ Bedroom 1 j ti /f I Job#: 311 great island rd,west Yarmouth Performed by Filipe Souza for: Scale: 1 : 148 Page 2 311 great island rd,west Yarmouth Right-suite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18:16:38 ...JslLipnick House Renovation.rup N fri •N Basement ! r * i 41.1. I Job#: 311 great island rd,west Yarmouth Scale: 1 : 148 Performed by Filipe Souza for: Page 3 Rig htSuite®Universal 2021 311 great island rd,west Yarmouth 21.0.08 RSU64567 2022-Jun-17 18:16:38 Js\Lipnick House Renovation.rup 7„4 Attic ccv CSi cal Job#: 311 great island rd,west Yarmouth Performed by Filipe Souza for: Scale: 1 : 148 Page 4 311 great island rd,west Yarmouth RightSuite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18:16:38 JslLipnick House Renovation.rup Duct System SummaryJob: 311 great island rd,west... QCDate: Jun 13,2022 w #pi*c , 1st Fl o o re By: Filipe Souza Project Information For: 311 great island rd,west Yarmouth Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest friction rate 0 in/100ft 0 in/100ft Actual air flow 388 cfm 388 cfm Total effective length (TEL) 375 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath c 1307 30 60 0 0 Ox 0 ShMt 7.0 175.0 st1 Bath 2 c 1253 32 57 0 0 Ox 0 ShMt 7.0 140.0 st2 Bath 3 c 381 12 17 0 0 Ox 0 ShMt 18.0 175.0 st1 Bedroom 1 c 1623 59 74 0 0 Ox 0 ShMt 34.0 150.0 st2 Bedroom 2 c 479 21 22 0 0 Ox 0 ShMt 16.0 160.0 st2 Bedroom 3 c 479 19 22 0 0 Ox 0 ShMt 14.0 165.0 st1 Dining Room h 794 50 36 0 0 Ox 0 ShMt 36.0 265.0 st1 Hall h 608 68 28 0 0 Ox 0 ShMt 26.0 165.0 st1 Hall 2 h 0 19 0 0 0 Ox 0 ShMt 21.0 105.0 st2 Hall 3 h 0 3 0 0 0 Ox 0 ShMt 5.0 175.0 st1 Kitchen h 1590 74 72 0 0 Ox 0 ShMt 42.0 230.0 st1 Stairs h 0 0 0 0 0 Ox 0 ShMt 20.0 220.0 st1 open Space h 0 0 0 0 0 Ox 0 ShMt 17.0 220.0 st1 utility h 0 1 0 0 0 Ox 0 ShMt 18.0 230.0 st1 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 257 235 0 0 0 0 x 0 ShtMetl st2 Peak AVF 131 153 0 0 0 0 x 0 ShtMetl y� 2022-Jun-17 18.16.24 r" ., , . Right-Suitee Universal 2021 21.0.08 RSU64567 Page 1 ..ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox 0 388 388 74.0 0 0 0 Ox 0 ShMt wrightsoft Right-Suite®Universal 2021 21.0.08 RSU64567 2022-Jun-1718:16:24 ..ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJ8 Front Door faces: N Page 2 . Duct System Summary Job: 311 great island rd,west... - ‘',''''N,,... , 5 HVAC 1 Summary Date: Jun 13,2022 AH1 By: Filipe Souza st•r� f,rc�„+.�v Project Information For: 311 great island rd,west Yarmouth Heating Cooling External static pressure 0.05 in H2O 0.05 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.05 in H2O 0.05 in H2O Supply/return available pressure 0.037/0.013 in H2O 0.037/0.013 in H2O Lowest friction rate 0.017 in/100ft 0.017 in/100ft Actual air flow 653 cfm 653 cfm Total effective length (TEL) 296 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk Bath 4 h 156 3 0 0.017 4.0 Ox 0 ShMt 52.8 165.0 st4 Bath 5 h 3062 57 25 0.018 7.0 Ox 0 ShMt 25.9 175.0 st4 Bedroom 4 c 3333 77 138 0.022 9.0 Ox 0 ShMt 16.3 150.0 st3 Bedroom 4-A c 3333 77 138 0.022 9.0 Ox 0 ShMt 10.3 160.0 st3 Reading Room c 2040 60 84 0.022 8.0 Ox 0 ShMt 18.8 150.0 st4 Reading Room-A c 2040 60 84 0.021 8.0 Ox 0 ShMt 13.9 160.0 st4 Room46 h 173 3 0 0.018 4.0 Ox 0 ShMt 47.1 165.0 st3 Stairs 2 h 296 5 0 0.018 4.0 Ox 0 ShMt 36.8 175.0 st4 Stairs 3 c 1242 29 51 0.022 6.0 Ox 0 ShMt 32.8 140.0 st4 Study Room h 5396 100 74 0.022 8.0 Ox 0 ShMt 67.8 105.0 st4 Sunroom c 3016 91 125 0.017 10.0 Ox 0 ShMt 80.1 140.0 st3 Sunroom-A c 3016 91 125 0.020 9.0 Ox 0 ShMt 79.1 105.0 st3 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 340 525 0.017 376 16.0 0 x 0 ShtMetl st4 Peak AVF 313 318 0.017 345 13.0 0 x 0 ShtMetl 2022-Jun-17 18.16:24 ., . wrightsof" Right-Suite Universal 2021 21.0.08 RSU64567 Page 3 /CCA ...ownloads\Manual Js\Lipnick House Renovation.rup Calc=MJB Front Door faces: N Return Branch Detail Table . Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb4 Ox 0 653 843 76.0 0.017 428 19.0 Ox 0 ShMt ,� , wrightsoft - Right-Suite®Universal 2021 21.0.08 RSU64567 2022-Jun-17 18:16:24 � C Page 4 ...ownloads\Manual JslLipnick House Renovation.rup Calc=MJ8 Front Door faces: N