Loading...
HomeMy WebLinkAboutEngineer PlanSITE PLAN SCALE: 1" = 20' B.M. = 31.31' (ASSUMED) ON TOP N� CORNER OF DECK ,P(K w. lom x 26b0' Wo et \ # MAP \ONn 27.761 es.+s• x \ �29........... de Rio �. ���......o\� o� gtq\ LOT 26 A:t 10,007t sq .f t. 7% aw \ 28.ee' O r� 0 29 28b8• x *f�9,p 0 \ -O RECEIVED in �a P 3 0 2023 1n HEALTH DEP�j T. Date of Soil Evaluation: November 29, 2023 Evaluation Performed By. Glen E. Harrington, R.S. Wltness:Borry Lewis, Asst. Health Agent, Yarmouth BOH Percolation Rate: t2 mpi (Cl Layer) Test Hole No. 1 DEPTH SOILS ELEV. 0 14" FILL 26.83 Imy sand 20" 10YR4/2 26.33 B Imy sand 10YR5/8 50" 23.83 c1 mM-c8mee zs e/a Adjusted GW - Redox 2r,......\..... . GENERAL NOTES 1. ADDRESS: 83 LUMBERJACK TRAIL, YARMOUTH 2. ASSESSOR'S NUMBER: MAP 74 PARCEL 33 3. DEVELOPER'S LOT: LOT #26 4. TOPOGRAPHIC INFORMATIDN WAS COMPILED FROM AN ON THE GROUND INSTRUMENT SURVEY. 5. TOWN WATER IS PROVIDED TO THE SITE & SURROUNDING PROPERTIES. 6. NO WETLANDS ARE LOCATED WITHIN 200 FEET OF THE PROPOSED SAS. 7. REFERENCE PLAN: PLAN BOOK 318 PAGE 20 REFERENCE PLAN: SEPTIC SYSTEM REPAIR PLAN LOCATED AT 83 LUMBERJACK TRAIL, WEST YARMOUTH, MA PREPARED FOR BLUEWATER SEPTIC," SEPTEMBER 23, 2010, SCALE: 1"=20', BY DARREN M. MEYER, R.S., 2 SHEETS. 8. UTILITIES LOCATED BY DIGSAFE. LOCATIONS ARE APPROXIMATE. 9. THIS DESIGN PLAN IS TO BE UTILIZED FOR THIS SEPTIC REPAIR ONLY. 10, EXISTING SEPTIC COMPONENTS LOCATED IN THE FIELD AND PER AS-BUILTS ON FILE. 11, THE DESIGNER HAS NOT BEEN CONTRACTED TO SUPERVISE THE INSTALLATION. G12. THE PROPERTY IS LOCATED WITHIN A DEP ZONE II. A 13. THE PROPERTY IS LOCATED WITHIN A DEP NATURAL RESOURCE AREA/ 'L.. NITROGEN SENSITIVE AREA. PAVED DRIVE` x \ .PROPOSED SAS e� 25'-001- X 13'-0"W X 24"D leaching trench using 2 H-20 500-gal chambers with 4' of stone all around. Health Department .2103 Date OUTLET PIPES FROM THE DISTRIBUTION BOX SHALL BE SET LEVEL FOR AT LEAST 2 FT. PLAN —SECTION 3 - 5" OUTLET KNOCKOUTS i SITE NO SCALE ALL 12" --I , CONCRETE COVER OUTLET � 12" INLET CROSS—SECTION 3 HOLE H-20 DISTRIBUTION BOX NOT TO SCALE LEGEND Test Hole Location $ Fire Hydrant —w— F -1 L_J (O1 r -----� L__ J Approximate location water line Existing contour Existing septic tank (to remain) 1984 leach pit to be pumped &removed Approximate location gas line 2010 leach field to be pumped &removed (See Construction Note #12) 6 ft. stockade fence New septic components PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR CAPEWIDE CONSTRUCTION, INC. AT #83 LUMBJERJACK TRAIL YARMOUTH, MA PREPARED BY: A PERFECT ENVIRONMENT LL dba GEO—CAPE ENVIRONMENTAL CONSULTANTS 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 No Weeping or Standing GW SCAL�'�'P"L^ZO' DRAWN BY: GEHRS DATE: 8 NOV 2023 DATUM: ASSUMED FILE: 83 Lumberjack SHEET 1 OF 2 Existing Dwelling 10, One chamber cover shall be within 6" of finished grade C3 C3 C3 G C3 7 G G 13 C G 5' Existin Grade Septic tank covers must be within 6" of finished grade EXISTING 1,000 GAL. SEPTIC TANK H-10 SYSTEM PROFILE Not to Scale PROPOSED 3 HOLE H-20 DIST. BOX Finished D-Box cover shall be within 6" of finished grade /FT . ' ' Level for 2' S=0.01' 3/4"-1'c" Double - Washed Stone One chamber cover shall be 12' wn. �Win• 2"of 1/6"-tt/2" �ouble-Washed Stone within 6" of finished race 36' MAX or geo-texttile f er coth 6" OF 3/4"-11/2" STONE 6" OF 3/4"-11/2" STONE H - 2 0 5' min. (5.6' provided) LEACHING CHAMBERS 3/4'-1%" Double -Washed Stone LEACHING CHAMBERS CROSS—SECTION Min. 2'-1/6'-1/2' Double —Washed Stone or geo—textile filter cloth Min. Facility Elev. Hole Elev./GW Elev. CONSTRUCTION NOTES 1. Contractor is responsible for Digsafe notification and protection of all underground utilities and pipes. 2. The septic tank and distribution box shall be set level on 6" of 3/4"-11/2" stone. ,w 3. Backfill should be clean sand or gravel with noI�C% 4. stones over 3" in size. This is to inspection during installation f system subject by Geo—Cape Environmental Consultants. <.A �' G 5. The contractor shall install this system in accordance S �Q with Title 5 of the Massachusetts Environmental Code local Board Health Rules Regulations. O and of and 'o 6. If, during installation the contractor encounters any k soil conditions or site conditions that are different from those shown on the soil log or in the design, �ZkAOFMgS yQi9 the installer shall halt installation and immediately notify o�' G N S Geo—Cape Environmental Consultants. I �� 7. No vehicle or heavy machinery shall drive over the R r septic system unless noted as H-20 septic components. 0. 70 8. Install Tuf—Tite as baffle or equal on septic tank outlet 9 q P tee. 9cc S �/STEY`� 9. All piping shall be SCH 40 PVC. 9N1TAR�Pa 10. No wells are located within 100' of proposed SAS. 11. Provide 1 H-20 DB-3 distribution box and 2 H-20 500—gallon chambers by Wiggin Precast or equal. 12. Existing SAS shall be pumped and removed within 5' of proposed SAS. All leachote contaminated material shall be removed and replaced with fill meeting specifications of 310 CMR 15.255(3). 13. Provide magnetic marking tape over components one —foot below grade to facilitate re —location of components. 7.67' Desian Calculations Number of Bedrooms: 3 Existing Garbage Disposal: Not allowed with this design Design Flow: 3 Bedrooms x 110 gal/bedroom =330 gpd Application Rate for Class I soil, <2 min./inch = 0.74 gal/sq. ft. Septic Tank Required: 330 gpd x 200% = 660 gpd. USE Existing 1,000—GAL Leaching Capacity Required: 330 gpd x 0.74 gal/SF = 446 SF Proposed Leaching Structure: 1-25'x13'x2' Leaching Trench Bottom Leaching Area Provided = 325 Sq.Ft. Side Leaching Area Provided = 152 sq. ft. Total Leaching Area Provided = 477 sq. ft. Leaching Capacity Provided =477 sq. ft X 0.74 gal/sq.ft.=353 gpd.>330 gpd. required. SEPTIC LAYOUT SCALE: 1"=20' A-1= 10'-2" B-1=35'-2" A-2= 27'-9" B-2=13'-4" PROPOSED SEPTIC SYSTEM REPAIR PREPARED FOR CAPEWIDE CONSTRUCTION, INC. AT #83 LUMBJERJACK TRAIL YARMOUTH, MA PREPARED BY: A PERFECT ENVIRONMENT L dba GEO—CAPE ENVIRONMENTAL CONSULTANTS 100 Independence Drive, Suite 7-623 Hyannis, MA 02601 SCALCVill"70' DRAWN BY: GEHRS DATE: 8 NOV 2023 DATUM: ASSUMED FILE: 83 Lumberjack SHEET 2 OF 2