Loading...
HomeMy WebLinkAboutReview Checklist TOWN OF YARt%IOUTH SEWAGE PLAN REVIEW CHECKLIST Location: A.M. Lot 9-30/ Zone of Contribution: In Out Acreage L Commercial: Residential:Street: / Su�4T �P}� ---- Village: S. y. Floor Plan: #Bedrooms: 3 Owners (.5- (t/c-. 0,oc a+6I InstaIler: > (,- Address: /5 ;c,K•f+,,,,,,sr I Phone: z Phone: S?Z�- 7 sac, /- 3 5)- �v/ Builder: Engineer: c / Address: g �n>/`1 y��� ��CIIV Phone: Phone: c - <-/i - s-jl7 N/A YES NO 1. Required#of copies received 2. Date of soils exam and percolation test not older than 2 years -- 3. 4-5 ft of naturally occurring pervious material, above water table - - 4. Foundation 2 ft above high point of road H.P.: Fnd: Var.: - 5. Water line 10 ft from septic components Var.: I - 6. Benchmark indicated and shown-NGVD if near wetlands t` 7. Septic tank minimum 10 ft from foundation, deck' Var.: '` 8. Leaching minimum 20 ft full, 15 ft crawl, 10 ft slab Var.: I ` -- 9. Leaching minimum 100 ft from wetlands Var.: I �` 10. Leaching minimum 150 ft from drinking we11/25 ft irrigation well Var.: 11. Tank/leaching minimum 10 ft from property line Var.: 1' 12. System meets all other setback requirements Var.: 13. Uses adjustment for maximum high groundwater Var.: I I 14. Leaching set 4-5 ft above adj. water or bottom of test hole Var.: ✓� 15. System not in top or subsoil (A,B horizons)or 5' removal 16. Proposed contours are suitable 17. System meets slope requirements- min. 1/8", %"preferred 18. System meets breakout requirements 19. Specified tee sizes are proper, gas baffle on outlet tee PVC liner: (./ Wall: 20. Sewage is under 10,000 gpd for parcel 21. No garbage disposal 22. System adequately sized for its intended use 23. Minimum 6"stone or compacted below tank and dbox I ' 24. Manhole covers within 6"of grade, pump chamber cover to grade 25. Inspection port on plastic chambers/leach field 26. Electrical permit for pump chamber/Se arate meter for du lexes 27. Pump system-2"line,weep hole,check valve, tee in dbox, pump size 28. Septic tank/pump chamber to be factory waterproofed 29. Vent provided if leaching below 3 feet,under driveway/parkin 30. Buoyancy calculations forlank/pump chamber 31. Engineer to inspect and certif y soils: wall: commercial: 32. Engineer/Registered Sanitarian and Land Surveyor stamps/signature 33.H-20 loading is subject to vehicular traffic,groundwater 34.Title V Application and permit fee, installer signature 35. Foundation footing min. 2 feet above adjusted ground water for new house 36. Deed Restriction required max. #bedrooms: max. flow: 37. Check area lots for groundwater/Label groundwater in Assessor's Map gpd / Plan reviewed by: It 7 /.23 -- - - !!! c o:0,