HomeMy WebLinkAboutInsulation affidavit 112123 AMR/BAN American Insulation Inc.
'A S LA �/eN Hanover MA 02339
IMJi./ !/ /� - --
www.americaninsulationmass.com
781 381 4000
11/21/2023
RE: 32 Woodbine Ave. West Yarmouth MA.
Dear: Building Department.
The International Building Code mandates that spray polyurethane foam be separated
from the interior of the building by a 15 minute thermal barrier or other approved
covering. DC 315 passed certified NFPA 268 and UL 1715 over a variety of open and
closed cell spray applied urethane foams that were conducted by certified testing
facilities.
DC 315 Thermal Barrier covers-88.88 sq. ft. /gal @ 18 mils wet and 12 mils dry NFPA 286
(AC377)
The space that the foam was left exposed was approximately 1,300 sq. feet and we used
14.606 gallons of DC315 paint. (Attic area)
18 WFT > 89 Sq. Ft. per One Gallon > 445 Sq. Ft. per Five Gallon
American Insulation, Inc. certifies the installations of the following work areas at the
corresponding R-Values with Natural therm HFO IBS Closed cell and Natural Therm
0.4 open cell sprayed in the corresponding areas of the project.
If there are any questions or concerns please do not hesitate to call 781 381 4000
Sincerely,
•
as 'a De Mo ra
Secretary,
American Insulation, Inc
Hanover. MA 02339 AM R/CAN
Phone: 781-381-4000 INSUTAT fN
Email: americaninsulationmass( gmail.com
www.americaninsulationmass.com
Affidavit Letter
Date: 11/21/2023
Re: 32 Woodbine Ave. West Yarmouth MA
Dear: Building Department.
American Insulation certifies the installations of the following work areas at the corresponding
R-Values with Open cell and Closed cell sprayed in place.
Also Batt insulation and Acoustical Fire Batt insulation.
Work Areas; R-Values
Exterior Walls 2x6 6"of Open cell foam R-21
Attic Roof 2x10 12"of Open cell foam R-49
Basement Ceiling 2x10 Faced Fiberglass R-30
Basement Blockers 2x10 6"of Open cell foam R-21
Stairs Wall 2x4 Unfaced Fiberglass R-15 +
Poly 4 mil.
*Natural -Therm 2.0 HFO IBS (R-Value), is formulated by multiplying the R-Value per
inch, which is 7.1 by the numbers of inches applied. (Closed cell)
*Natural - Therm light 0.4 (R-Value), is formulated by multiplying the R-Value per inch,
which is 3.7 by the numbers of inches applied. (Open cell)
If there are any questions or concerns please do not hesitate to call 781-381-4000.