Loading...
HomeMy WebLinkAboutWell Completion Report Massachusetts Department of Environmental Protection Bureau of Resource Protection Well Completion Reports Well Driller Please specify work performed: Address at well location: New well Street Number: Street Name: 29 INDUSTRAIL PARK RD Please specify well type: Building Lot#: Assessors Map#: Domestic �.__.__..... € 74 Assessor's Lot#: ZIP Code: Number Of Wells: 12 02673 City/Town: Well Location YARMOUTH In public right-of-way: GPS Yes C No ' North: West: 41.67897 70.25159 Subdivision/Property/Description: Mailing Address: click here if same as wet location address Property Owner: Street Number: Street Name: LOU STERGIS 8 STONEFIELD DRIVE City/Town: State: Engineering Firm: SANDWICH MASSACHUSETTS ZIP Code: 02537 Board of health permit obtained: C Yes a Not Required Permit Number: Date Issued: DEC 0 8 2023 HEALTH DEPT. ;uawaaeld (;unoo)1 (le6) 10 Po4WW I sa4a;e81 JeWM ;461eM Z lepoleW ;4610M 1 Iel�a;eV o1 WOJd H3Vd 89111d I1VJS 21V'1f1NNV (wd6)A;!Oede3 dwnd leu!WON (4)41daa aNe;ul dwnd Jamodesio —uogdpasaa iamodasJoH uogdiJosaa dwnd 8soo1.13 dwnd asooy3- (3181flIVAV dl)dINfld 1N3NVIN213d r Zl r 0£ 1 ii (wd6)PIMA of wad i113M MCI,_j S3n1OZ ONI JV31}2131VM 41 Z1,0'0 3� lu!Od IIaM Iaa1S SSaIU!e;g 0£1 LZ ,a e10 aZIS VMS adl(1 _ 01 wad uaar3S ON_j N33LIOS _ 1 seA J 1..._-------4] ,E- 04 olnpay3S fr aPUO1431Au!AAlOd ! I L! a 01 eoysanua Je;ewegj ssauilo!y1 adi j. oil WOJd 0 :01 1. :wad 4punoi6 enoge 6u!se3 s!A ONISV3 (IN.)saA y ;ueweoueyu3 8.1nppeJ auol. adA1 Teas aoepns popeNowpag of 4ldaa 0£ 41de4 IIaM lewol GINJ saA a.) paloa/ulsl0 aN J seA.� padolana4 NOl1VW2IOJNl 113M 1VNOI11aaV uo!iippy Ssoi MOIS iSed 1 4i S3A saA sa J J J 1 J J t aP°3 asoo43 i sd143 6ulu!e;g poi; a;eJ pup mots we;s pup; Mite, ;o uo!l!ppe I luawwoo apoO (;{)01 (U)wad et3X3 ;sn2!ans!A �0 sso� JO;se;wix3 ul da0 1 1 AOO1OHIJ1)I3Oa038 001113M uoll!pPV ss01 11 91 -- 1 i ON S3A !I . - J J 1 1 mots J ised J 1 ..... } 1' . umwg 1=.S asieo3 Oi Mind 0£ [ Ol! uomppy ssol { al S3A ;'f__ I mOIS 1Sed 11: [ 9I !i Pev Ol 1 ._ 0 J J II J .J ! • uma . PueS wm ! pm;bO' a;eill!JP wa4s 1!! uOgippe JO SSO1 MOIS JO;se;ea;x3 i pup u!dcu ;uawwoO MOO epOO (;l)01 (8)wad E AOO10I-W1 N3OMf18a3AO 001113M —il3apa8 asooy3— aa6nd ilootpa8 uepingaan0 aOH1301 ONI II8C1 WJOd IIaM leaauao - Java IIaM (/eJeuee)spoded uoneldwo0 geM r :1: k 1 weJ6ad JallPa IIaM—uo4oa;ad eotnosaa;o neaing uol;oa;ad le;uewuot!Au3;o;uewuedeo suasnyaesselry Massachusetts Department of Environmental Protection coils i, Bureau of Resource Protection—Well Driller Program Well Completion Reports(General) Choose Material + Choose Material + ( i —Choose One— J WELL TEST DATA Time Pumped 7 Pumping Level(ft Time To Recover Recovery(ft Date Method Yield(gpm)`(HH:MM) BGS) (HH:MM) BGS) 11/27/2023 I ;Constant Rate Pump 21 12 11 01:00 [13 0:01 111 WATER LEVEL Date Static Depth BGS(ft) Flowing Rate(gpm) Measured I 11/27/2023 '11 ! 12 COMMENTS WELL DRILLERS STATEMENT This well was drilled or altered under my direct supervision,according to the applicable rules and regulations,and this report is complete and accurate to the best of my knowledge. WILLIAM Supervising Driller DESMOND, Monitoring[M] DrillerURQUHART Registration# 299 Signature THOMAS,E DESMOND WELL Firm DRILLING,INC. Rig Permit# 024 Date Job Complete 11/27/2023 I NOTE:Well Completion Reports must be filed by the registered well driller within 30 days of well completion. ENVIROTECH LABORATORIES,INC. MA CERT. NO.:M-MA 063 8 Jan Sebastian Drive Unit 12 Sandwich,MA 02563 (508)888-6460 1-800-339-6460 FAX(508)888-6446 Client Name: Desmond Well Drilling Location: Address: PO Box 2783 29 Industrial Park Rd Orleans, MA Yarmouth,MA 02653 Lab Number: DW-235023 Collected By: Desmond Well Drilling Date Received: 11/27/23 Sample Type: New Well Well Specs: Static 11'Depth 30' Location Source Date Collected Time Collected Comments A 11/27/23 13:30 Well ti Analysis Requested Units Recommended Limits Analysis Result Method Date Analyzed Analyzed By Total Coliform CFU/100mL 0 0 SM9222B 11/27/2023 KF @ 15:45 pH _. pH units 6.5-8.5 5.61 SM 4500-H-B 11/27/2023 KF Specific Conductances umhos/cm 500 134 EPA 120.1 11/27/2023 KF Nitrite-N mg/L 1.00 <0.006 EPA 300.0 11/28/2023 KF Nitrate-N mg/L 10.0 0.14 EPA 300.0 11/28/2023 KF Sodium mg/L 20.0 18 EPA 200.7 11/29/2023 KB Total Iron mg/L 0.3 0.094 EPA 200.7 11/29/2023 KB Manganese mg/L 0.05 .0.020 EPA 200.7 11/29/2023 KB Comments: Low pH indicates high corrosive characteristics. All samples were analyzed within the established guidelines of US EPA approved methods with all requirements met, unless otherwise noted at the end of a given sample's analytical results. We certify that the following results are true and accurate to the best of our knowledge. Water meets EPA standards and is suitable for drinking for parameters tested. fr, Date 12/5/2023 Ronald J.Saari Laboratory Director BRL=Below Reportable Limits *See Attached Page 1 of 1 ❑Certification is not available for this analyze for potable water samples.. Massachusetts Department of Environmental Protection Bureau of Resource Protection Well Completion Reports Well Driller Please specify work performed: Address at well location: New Well Street Number: Street Name: 21 ARLINGTON ST Please specify well type: Building Lot#: Assessor's Map#: Irrigation 1 28 Assessor's Lot#: ZIP Code: Number Of Wells: 17 02673 City/Town: Well Location YARMOUTH In public right-of-way: GPS ( Yes f No North: West: 41.64951 70.27369 Subdivision/Property/Description: Mailing Address: r click here if same as well location address Property Owner: Street Number: Street Name: WAYNE KURKER 1 WILLOW ST City/Town: State: Engineering Firm: BARNSTABLE MASSACHUSETTS ZIP Code: 02601 Board of health permit obtained: r Yes r;Not Required Permit Number. Date Issued: 1 0l. (wd6)A;!oede0 dwnd leu!WON 9Z (il)Uldap aa!elui dwnd algisiewgns, amodasJoH • • uo!lduosa0 dwnd peads luelsuo0 aim Z (318ViIVAV al)and 113NVIIY213d Z1 i o£]j 1 1 (wd6)PIMA oil w0Jd ll3M Aa0 J S3NIOZ OMIId38.831VM LII--4 t.._._._..Z10'0 Fr w!od IIaM Reis ssalulels 1 `! .... LZ Ja;awela OZ!S lo13 adAi 01 Woad Ua0J3S ON J N33e1OS aA _j 4 op OInPOIPS t_ 9PUOIt1 IAu!ANod j LZ� 0 eo4soApa Ja;ewela s301.34 3141 aiAl l 01 wad k,puna6 anoge 6u!se3 s!j ONISVO oN v so),J luawaouequl am;oeJ4 euol adA1 leas aoe4.ins ploapa8 al 41daa OE LlInn0 IIaM lelol °Ii J saA. pa;oa;u!s!0 aN..1 se),.1 padolana] NOI1VW21OdNI 113M 1VNOl1WOOV I uo!l!ppy ssol MoIS lead ; ON SBA " -- y0 ra epo0 asoo saA J saA I ,.) J -1 1 J ,.1 ll L._.... sd 40 6u!ule;S ping am pup mole well;IIpP a6ael PO ;o uoimppe �o;se;e�yc3 ul daa' wewwoo ° O (14)01 (N)woid ;sna algisiA e„x3 Jo ssol AOOIOHl1I NNO021038 901113M uomppy ssol ON S3A !!'mole j;sed ((�^^-��uma8 I 3 s asieo0 o1 auld 0£1 9Z uo!l!pPtl ssol (4 S3A ill , Mole j lsed J , , i . uma8( . puss au!d SZ) L0Z uo!yppy ssoo _........_...___._.._._..__._--- jl c SBA6 !!r_ i mole J 3sed. L 't•.................................umw8 IF asi5OO of au. OZi !! 0 P!nl;O' °lei IIPP' was uo!;!ppe JO ssol. Jpc' Mole Jo;se;E3 llup u!dap ;uewwoO JqoO apoO (gbl (g)wa j l 1 A0010H1l1 N302U18213A0 901113M -NocuPe9 es0040-1 4a6ny >loa ee uapJngJano 0OH131A1 0NIl1R10 WJOd IIaM Ieaaues - Java IIaM (/eieueS)spoda2/uo/;a/dwoO lleM Ell wea6ad JeII!a0 IIaM-uo!;oaload eanosej jo neon uolloa;ad le;uewua!Au3;o;uewpedea suesngoesseW Massachusetts Department of Environmental Protection La ' Bureau of Resource Protection—Well Driller Program Well Completion Reports(General) ANNULAR SEAL/FILTER PACK Water Batches Method Of From To Material 1 Weight Material 2 Weight (gal) (count) Placement 11 I :Choose Material ,_J ..._...__._._..i .Choose Material W Ei ___.____.11„ . . ...._... E. 1-Choose One— ,ji WELL TEST DATA Time Pumped 'Pumping Level(ft Time To Recover Recovery(ft Date Method Yield(gpm) (HH:MM) BGS) (HH:MM) BGS) 11/27/20231 1 Constant Rate Pump f 112.__.__._._ €(01^:00 . ..... 13.. .... ____ 0:01 u 1 �.._.____._...1 WATER LEVEL Date Static Depth BGS(ft) I Flowing Rate(gpm) Measured i [11/27/2023 i 11 i 12 COMMENTS WELL DRILLERS STATEMENT This well was drilled or altered under my direct supervision,according to the applicable rules and regulations,and this report is complete and accurate to the best of my knowledge. WILLIAM Supervising Driller DESMOND, Monitoring[M] DrillerURQUHART Registration# 299 Signature THOMAS,E DESMOND WELL Date Job Complete Firm DRILLING,INC. Rig Permit# 024 11/29/2023 NOTE:Well Completion Reports must be filed by the registered well driller within 30 days of well completion. ENVIROTECH LABORATORIES,INC. MA CERT. NO.:M-IPL4 063 8 Jan Sebastian Drive Unit 12 Sandwich,MA 02563 (508)888-6460 1-800-339-6460 FAX(508)888-6446 Client Name: Desmond Well Drilling Location: Address: PO Box 2783 21 Arlington Street Orleans, MA Yarmouth,MA 02653 Lab Number: DW-235036 Collected By: Desmond Well Drilling Date Received: 11/28/23 Sample Type: Irrigation Well Specs: Location Source Date Collected Time Collected Comments A 11/28/23 13:00 irrigation Analysis Requested Units Recommended Limits Analysis Result Method Date Analyzed Analyzed By Total Coliform CFU/100mL 0 0 SM92228 11/28/2023 KF @ 15:15 pH pH units 6.5-8.5 7.44 SM 4500-H-B 11/28/2023 KF Specific Conductancen umhos/cm 500 267 EPA 120.1 11/28/2023 KF Nitrite-N mg/L 1.00 <0.006 EPA 300.0 11/29/2023 KF Nitrate-N mg/L 10.0 <0.01 EPA 300.0 11/29/2023 KF Sodium mg/L 20.0 29 EPA 200.7 11/29/2023 KB Total Iron mg/L 0.3 2.29 EPA 200.7 11/29/2023 KB Manganese mg/L 0.05 0.246 EPA 200.7 11/29/2023 KB Comments: Sodium level is not a health hazard. Iron Level is not a health hazard,but may cause taste and staining problems. Over a lifetime,the EPA recommends that people drink water with manganese levels less than 0.3 mg/L and over the short term,EPA recommends that people limit their consumption of water with levels over 1.0 mg/L All samples were analyzed within the established guidelines of US EPA approved methods with all requirements met, unless otherwise noted at the end of a given sample's analytical results. We certify that the following results are true and accurate to the best of our knowledge. Watermeets EPA standards and is suitable for drinking for parameters tested. Date 12/5/2023 Ronald J.Saari Laboratory Director BRL=Below Reportable Limits *See Attached Page 1 of 1 °Certification is not available for this analyte for potable water samples..